• Title/Summary/Keyword: odor pollutants

Search Result 69, Processing Time 0.03 seconds

A Study on the Atmospheric Dispersion of Odor Emitted from Banwol/Sihwa Industrial Complex in Ansan Area (반월, 시화공단 악취물질의 안산지역 확산 연구)

  • Song, Dong-Woong;Song, Chang-Keun;Kim, Cheol-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.5
    • /
    • pp.323-340
    • /
    • 2003
  • There have been persistent civil appeals in Ansan area against the odor and aerosols emitted from nearby Banwol/Sihwa industrial complex. A fundamental solution for the good air quality has not been addressed yet in spite of the continuous counterplan to reduce odor emission. A systematic and scientific study is needed to examine the reason for the odor episode and to predict the impact coverage of odor pollution. An approach by computational simulation is considered to be adequate to investigate the transportation and the dispersion processes of air pollutants blown by sea breeze toward the coastal city, Ansan. This study has employed various dispersion models to simulate the transportation and the dispersion processes of odor pollutants by a local circulation between land/sea breeze using the data set of emission rates of odorous species from the Banwol/Sihwa industrial complex.

Assessment of Odor Issues and Technologies in Wonju Traditional Market

  • Benish ZAHRA;Young-Jin SO
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.7 no.4
    • /
    • pp.21-28
    • /
    • 2024
  • This study investigates the sources and characteristics of odor pollutants, focusing on total volatile organic compounds (TVOCs), hydrogen sulfide, and ammonia in traditional markets. The objective is to assess the impact of these odors on market environments and evaluate the effectiveness of new odor-reducing techniques. Research design, data, and methodology: Conducted in Wonju Traditional Market, the research employed a longitudinal design to analyze odor concentrations over time through continuous monitoring at five strategically established points. Measurements were taken continuously for five minutes at one-minute intervals using the AOMS-1000 odor-measuring equipment. The study also applied a sewage odor-reducing substance spraying device designed to minimize unpleasant odors. Data was collected in the summer of 2022 and again in the summer of 2023, allowing for a comparative analysis of odor levels before and after implementing the odor-reducing technique. Results: Findings revealed significant concentrations of TVOCs, hydrogen sulfide, and ammonia, with a notable reduction in pollutants following the introduction of the odor-reducing device. Conclusions: This study highlights the importance of effective odor management in traditional markets. It recommends the adoption of advanced technologies such as biofilters, electrostatic precipitators, and photocatalytic purification systems to better control odor emissions. Implementing these solutions can significantly enhance the shopping experience for consumers.

Evaluation on Odor Removal Performance of Bacteria-Based Odor Reduction Kit for Revetment Blocks (호안블록용 박테리아 기반 악취저감 키트의 악취제거 성능평가)

  • Keun-Hyoek Yang;Ju-Hyun Mun;Ki-Tae Jeong;Hyun-Sub Yoon;Jae-Il Sim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.2
    • /
    • pp.229-238
    • /
    • 2024
  • This study evaluated the odor removal performance of a bacteria-based odor reduction kit. The bacteria used were Rhodobacter capsulatus, Paracoccus limosus, and Brevibacterium hankyongi, which can remove ammonia (NH3), hydrogen sulfide (H2S), total nitrogen (T-P), and total phosphorus (T-N), which are odor pollutants. The materials used were bacteria and porous aggregates (expanded vermiculite, zeolite beads, activated carbon), and the combination of the materials varied depending on the removal mechanism. Materials with a physical adsorption mechanism (zeolite beads and activated carbon) gradually slowed down the concentration reduction rate of odor pollutants (NH3, H2S, T-P, and T-N), and had no further effect on reducing the concentration of odor pollutants after 60 hours. Expanded vermiculite, in which bacteria that remove odors through a bio-adsorption mechanism were immobilized, had a continuous decrease in concentration, and the concentration of odor pollutants reached 0 ppm after 108 hours. As a result, the odor removal performance of materials with physical adsorption mechanisms in actual river water did not meet the odor emission standard required by the Ministry of Environment, while the expanded vermiculite immobilized with bacteria satisfied the odor emission permissible standard and achieved water quality grade 1.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

Health Effects from Odor Pollution in Sihwa Industrial Complex (경기도 시화공단 지역주민의 악취오염과 관련된 건강영향 평가)

  • Cho, Soo-Hun;Kim, Sun-Mean;Kim, Young-Su;Kim, Jae-Yong;Choi, Seong-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.4
    • /
    • pp.473-481
    • /
    • 1999
  • Objectives: In recent days, the problem of odor pollution in community near Sihwa Industrial complex, Kynuggi Province is becoming of significant public concern. We have investigated the health effects of the Sihwa residents from odor pollution comparing with other less polluted areas. Methods: The Ansan and Kuri Cities were selected as control areas. The parents of the elementary and middle school students in these three areas were surveyed with structured questionnaire twice, Nov 1997 and Jure 1998 each. As a exposure index, the ambient air concentrations of five major air pollutants(particulates, $O_3,\;SO_2,\;NO_2$, CO) and subjective odor perception were used. We have focused health outcomes such as the prevalence of nonspecific irritant symptoms, respiratory disease among family members and the score of qualify of life(QOL). Results: Although the mean concentrations of major air pollutants except particulates were similar or lower in Sihwa than other areas, the odor perception rate and the monthly odor perception days were significantly higher. It suggested that odor producing chemical compounds are the major source of environmental pollution problem. There were higher prevalence rates of nonspecific irritant symptoms and respiratory disease among family members in Sihwa than other control areas. The QOL score was also lower in Sihwa. The odor perception proved to be a most important factor in reporting adverse health effects and lowering the QOL score. Conclusion: The residents living near Sihwa industrial complex were suffering from more adverse health symptoms and poorer QOL status than control areas. And it may be due to environmental odor pollution from industrial complex. Therefore, further research will be needed for monitoring of the responsible chemicals emitted from industries.

  • PDF

Removal Technologies of Odor and Volatile Organic Compounds from Industrial Processes (산업체 VOC/악취 저감기술)

  • Choo, Soo-Tae;Nam, Chang Mo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.3
    • /
    • pp.289-297
    • /
    • 2004
  • Emissions of volatile organic compounds and odors from various industrial processes not only pollute surrounding life environments, but also lead to the deterioration of the working environments, causing various industrial health and business problems. These pollutants are usually stimulating, irritating, malodorous and sometimes carcinogenic, Which should be reduced in the pollutants formation, stage, but the practical processes do not allow This paper describes the major sources of VOC and odors, and their sampling/analysis methods. Furthermore, various removal technologies for these pollutants are suggested, which particularly include the characteristics of the catalytic and scrubber/carbon filter combined process, and even process design technologies.

  • PDF

A Comparative Study for Odor Control Regulations (악취관리제도의 국가간 비교연구)

  • 양성봉;김석만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.79-87
    • /
    • 2000
  • This study analyzed the regulations concerning odor management or control in Korea, Japan, and developed countries such as USA and Germany. The Korean restriction standards and measurement methods for offensive odor substances are very similar to the Japanese standards and methods promulgated in 1976. Japan promulgated the odor control act and the specific measurement methods of the offensive odor substances in 1973. In Japan, currently, the local governments can establish their own odor restriction areas and proclaim their own standards suitable for their situations. Also, Japan has more strict regulations and more offensive odor substances to be monitored than Korea. The restriction standards of odor in German is quite similar to the permissible limits and standards of air pollutants at emission sources in Korea. Many states in USA are adopting their own restriction standards and measurement methods, e.q., the ambient air pollution standards, organic functionstest methods by dilation, and establishment and addition of air pollution control equipment at emission sources. Finally, this study analyzed the problems of the regulations, standards, and measurement methods concerning the Korean offensive odor management. Since the direct organic fuctions measurement(DOFMM) method is depending upon the personal sensitives of odor substances, the measurement odor value can be equivocal. That is, the odor measurement value by an examines can differ from that by the other examines. Also, there can be conflicts with the measured odor values depending upon the applied measurement methods, e.q., the DOFMM, the dilation method, and the instrumental analysis method.

  • PDF

Emission Characteristics of Odor Compounds in a Charcoal Production Kiln (숯가마 배가스 중 악취물질의 배출특성)

  • Park, Seong-Kyu;Choi, Sang-Jin;Hwang, Ui-Hyun;Lee, Jeong-Joo;Kim, Daekuen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.319-326
    • /
    • 2014
  • Exhaust gas emitted as a result of the incomplete combustion of biomass in charcoal kilns includes odor compounds as well as other air pollutants such as particulate matters, sulfur and nitrogen oxides, and carbon monoxide. A number of offensive odor compounds affect quality of life. In this study, odor emissions were investigated from biomass burning in a pilot-scale charcoal kiln and a commercial-scale kiln. Complex odor from emission source reached up to 10,000 dilutions to threshold during the study period. Combustion fume was found to contain reduced sulfur compounds, aldehydes, and volatile organic compounds. Hydrogen sulfide and methyl mercaptan were the major odorants which highly contributed to the offensive odor.

Dispersion of Air Pollutants Dispersion and Odorous Materials in Cheon-an Second Industrial Complex (하절기 천안 제 2산업단지의 대기오염확산 및 악취물질에 관한 연구)

  • Chung, Jin-Do;Hong, Jeng-Hee;Kim, Su-Young;Kim, Jung-Tae;Choi, So-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1316-1322
    • /
    • 2006
  • The purpose of this study is to analyze the pattern distribution of the odorous compounds and air pollutants from the inventory sources in the Cheon-an second industrial complex. Twelve analysis including specified odor materials and air pollutants were concurrently measured during the month of August, 2005 to evalaute odor emission characterization in m3;or treatment facilities. Also, Concentration of air pollutants has been calculated by ISCST3 in ISC3 models. A Korean air diffusion modeling software, Air Master, was developed on a basis of diffusion theories adopted in U.S. EPA's ISC3 model to assess the air quality impact from the stacks. This investigation will be executed how large the complex pollutant sources such as industrial complex contribute to atmospheric environment and air quality of the surrounding the area as predicting by comparing and analyzing results of odorous compounds and air pollutants diffusion concentration model.

Study on the Characteristics of Odor Emitted from Swine Facilities (양돈시설에서 발생하는 악취특성에 관한 연구)

  • Kim, Jae Hyuck;Yoo, Kyung Seun;Oh, Je Beom;Jung, Ju Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.439-444
    • /
    • 2012
  • We studied the characteristics of odor emitted from 40 swine facilities across the country under various conditions like rearing densities, management style, ventilation system and swine manure handling characteristics, based on the olfactory and analytical evaluation. Odor concentrations (D/T) measured from swine facilities were respectively an average 4,055 D/T at liquid manure storage tanks on aeration, an average 913 D/T at slurry manure storage, an average 506 D/T at finishing swine facilities and an average 201 D/T at composting facilities. The higher rearing densities and slurry accumulation volume in finishing swine house, the more odor concentration (D/T) was increased. But The odor concentration (D/T) in finishing swine house did not show significant difference according to application of microbial additives. 9 odor compounds ($NH_3$, $H_2S$, MM, DMS, DMDS, PA, n-BA, n-VA, i-VA) were detected at swine facilities and the main odor compounds were volatile sulfur compounds such as $H_2S$, MM and volatile fatty acids compounds such as n-BA, n-VA, i-VA. 97.5% of swine farms surveyed in this study is located within 300 m of residential area and it is easy to bring odor complaints.