• 제목/요약/키워드: oddball paradigm

검색결과 17건 처리시간 0.021초

Detection and Analysis of Event-Related Potential P300 in EEG by 4-Stimulus Oddball Paradigm

  • Jang, Yun-Seok;Ryu, Soo-Ah;Park, Kyu-Chil
    • Journal of information and communication convergence engineering
    • /
    • 제8권2호
    • /
    • pp.234-237
    • /
    • 2010
  • P300 component of the event-related potential(ERP) has been studied for theoretical, empirical, and clinical applications. Nowadays the 1-, 2-, and 3-stimulus oddball paradigms are used for eliciting P300 component of EEG in the auditory stimulus experiments. In this paper, we used a method to add one more stimulus to the 3-stimulus auditory paradigm. The adding stimulus has not the same volume but the same tone of the target stimulus. The 4-stimulus oddball paradigm to use two targets is used to elicit the P300 event-related potentials. In 4-stimulus oddball paradigm, an infrequent non-target (p=0.10) is presented in addition to two infrequent targets (p=0.10) and a frequent standard (p=0.70). Two target stimuli elicited a P300 component with a parietal maximum distribution. The amplitude of the P300 in target 2 was larger than that in target 1 and the latency of the P300 in target 2 was longer than that in target 1. The P300 component due to target 2 stimuli was larger than that due to target 1 stimuli. The experimental results approve that the 4-stimulus oddball paradigm can elicit P300 component clearly. The results are compared with the results of the traditional oddball paradigm.

Analysis of P300 Related Target Choice in Oddball Paradigm

  • Jang, Yun-Seok;Ryu, Soo-Ah;Park, Kyu-Chil
    • Journal of information and communication convergence engineering
    • /
    • 제9권2호
    • /
    • pp.125-128
    • /
    • 2011
  • P300 component of the event-related brain potential (ERP) reflects fundamental cognitive processes. The P300 components have been employed in a wide variety of theoretical, empirical, and clinical applications. In oddball paradigm for eliciting P300, we need standard stimuli and target stimuli. Firstly, designated stimuli are presented to subjects. Nextly, a chosen target stimulus is presented. In this paper, we elicited the P300 components with experiment that the subjects select a chosen target stimulus. Therefore, we measured the P300 components to be related choice of the target stimuli. The experimental results and the P300 components to be analyzed were presented.

Harmony Matters in Alarm Design: Investigating the Impact of Consonance on Alarm System

  • Ilgang Mukko Lee;Yunsun Alice Hong;Juhyun Jay Lee;Kwanghee Han
    • International Journal of Advanced Culture Technology
    • /
    • 제11권4호
    • /
    • pp.406-416
    • /
    • 2023
  • Alarm system performance is a critical aspect of safety. While existing research has extensively examined the influence of acoustic attributes on alarm performance, consonance's impact remains largely uncharted territory. This study bridges this research gap by investigating the effect of consonance on alarm systems. We extend our investigation to encompass not only the sound characteristics of the alarm but also the acoustic qualities of the surrounding environment, recognizing their potential impact on alarm efficacy. Prior studies consistently link consonance to annoyance levels, resulting in a negative user experience. Thus, we explore the relationship between consonance and alarm system performance, with a particular focus on modulating annoyance as an explanatory factor. Utilizing an oddball paradigm, we categorized standard and oddball sounds into consonant and dissonant types, creating four sound combinations. Participants were asked to respond to the irregularly presented oddball sounds while ignoring the constantly presented standard sounds. Our results reveal significant differences between groups, with the Standard Consonant/Oddball Dissonant (SC/OD) group displaying notably slower response times than the Standard Dissonant/Oddball Consonant (SD/OC) group. This reaction time variation aligns with differences in annoyance levels, as the SC/OD group reports higher annoyance, suggesting that reaction time discrepancies may be linked to increased arousal due to heightened annoyance.

조현형 인격 성향을 가진 대학생의 P300 국소화 분석 (Analysis of source localization of P300 in college students with schizotypal traits)

  • 장경미;김보미;나은찬;안은지;김명선
    • 인지과학
    • /
    • 제28권1호
    • /
    • pp.1-26
    • /
    • 2017
  • 본 연구는 청각 oddball 방안, 사건관련전위와 sLORETA를 사용하여 조현형 인격 성향을 가지는 대학생의 P300 신호원을 조사하였다. 또한 P300 신호원의 전류밀도와 조현병 증상간의 관계를 조사하였다. Schizotypal personality questionnaire(SPQ)의 점수에 근거하여 조현형 인격성향군(n=37)과 정상통제군(n=42)을 선정하였다. P300은 자주 제시되는 표준 자극(1000Hz)과 드물게 제시되는 목표 자극(1500Hz)으로 구성되는 청각 oddball 과제를 사용하여 측정하였으며, 참여자들은 목표 자극이 몇 번 제시되었는지 횟수를 세어 실험 후 보고하는 것이 요구되었다. 행동분석 결과, Oddball 과제의 정확률에서는 두 집단 간 유의한 차이가 관찰되지 않았다. 사건관련전위를 분석한 결과, 조현형 인격성향군이 정상통제군에 비해 유의하게 감소된 P300 진폭을 보였다. P300의 신호원을 추정하기 위하여 sLORETA를 사용하여 분석한 결과, 두 집단 모두에서 좌우반구 전두엽, 두정엽, 측두엽, 후두엽에 분포되어 관찰되었다. 두 집단의 P300 신호원의 전류밀도를 비교한 결과, 조현형 인격성향군이 정상통제군에 비해 좌반구 상측두회와 우반구 중측두회에서 감소된 활성화를 보인 반면 좌반구 하전두회와 우반구 상전두회에서는 활성화 증가를 보였다. 이에 덧붙여, 조현형 인격성향군에서 우반구 상전두회의 전류밀도와 SPQ의 와해 점수 사이에 부적 상관이 관찰되었다. 이러한 결과는 P300 신호 원인 전두 및 측두 영역의 이상을 조현병 환자뿐만 아니라 경미한 증상을 가지고 있는 조현형 인격성향군도 가지고 있음을 시사한다. 이에 덧붙여 본 연구 결과는 조현병 고위험군의 선별에 사용되는 SPQ의 경우 총점보다는 와해 점수가 고위험군의 선별에 더 유용하게 사용될 수 있음을 시사한다.

美(미)醜(추) 콘텐츠 시청 시 발생하는 뇌파 신호 분석 (An Analysis of EEG Signal Generated from Watching Aesthetic and Non-aesthetic Content)

  • 김용우;강동균;강행봉
    • 한국멀티미디어학회논문지
    • /
    • 제21권1호
    • /
    • pp.1-9
    • /
    • 2018
  • Much research has been conducted to judge aesthetic value for a single type of stimuli, but research to determine aesthetic value when two kinds of stimuli are presented at the same time is not explored in depth. In this paper, we measure the difference between the presentation of visual stimuli like general image and the presentation of signboard image including text stimuli using EEG. In the experiment, two oddball tasks were performed for general images and signboard images, and EEG changes according to the aesthetic value of the images were measured. As a result, the change of ERP in signboard image was larger than that of general image. We confirmed that more visual information was received and processed when two stimuli were presented at the same time.

정신분열병 환자에서 40Hz 뇌 사건관련전위에 관한 연구 : 분석 방법론적 측면 (The Analysis of 40Hz Event-Related Potentials in Schizophrenia)

  • 윤탁;박해정;강도형;김명선;김재진;권준수
    • 생물정신의학
    • /
    • 제8권2호
    • /
    • pp.251-257
    • /
    • 2001
  • Backgrounds : Gamma band oscillatory activity is considered to be related to cognitive functions and illustrates that the concept of event-related oscillations bridges the gap between single neurons and neural assemblies. An event-related gamma oscillation is the time-locked responses of specific frequency, and can be identified by computing the amplitude frequency characteristics of the averaged event-related potentials(ERPs) after stimulation. Objectives : We purposed to present experimental paradigm to investigate ${\gamma}$-band oscillation activities from the recording of ERPs by using auditory oddball paradigm and investigate the difference of ${\gamma}$-band activity between schizophrenia and normal controls. Methods : The ERPs resulting from auditory stimuli with oddball paradigm in a group of schizophrenics(n=11), and also a group of age-, sex-, and handedness matched normal controls, were recorded by 128 channel EEG. The ${\gamma}$-band oscillatory activities were calculated by using time-frequency wavelet decomposition of the signal between 20 and 80Hz. The ${\gamma}$-band oscillatory activities of both groups were compared by t-test. Results : The ${\gamma}$-band oscillatory of the leads Fz, Cz, and Pz of both groups were represented well in the time-frequency maps. Significant increases of the ${\gamma}$-band activity in normal controls compared with schizophrenics were observed around 160 msec, 350 msec, and 800 msec after stimulation. Conclusions : Our results suggested that the increment in ${\gamma}$-band oscillatory activity during cognitive operations and decreased ${\gamma}$-band activity in schizophrenics may be associated with the cognitive dysfunctions and the pathophysiology of the schizophrenia.

  • PDF

사상관련전위 P300 요소를 이용한 알츠하이머형 치매의 탐지와 분석 (Alzheimer Disease detection and analysis using P300 componenet of ERP in Alzheimer type Dementia)

  • 박은혜;이영혁;임재환;김종우;황의완;김현택
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2002년도 추계학술대회 논문집
    • /
    • pp.148-152
    • /
    • 2002
  • This study is to develop the Alzheimers disease (AD) detection and analysis system using event-related potential (ERP) of AD patients. We recorded ERP in an auditory oddball paradigm in mild AD (n=25), severe AD (n=12), age-matched normal aged controls (n=17), and young controls (n=7). The amplitude and latency of target P300 components were compared among 4 groups. The relationship between P300 measures and neuro psychological test (K-DRS) scores were evaluated by correlations. The latency of P300 was prolonged in AD and the effects were correlated with the severity of dementia. The P300 amplitude was not affected significantly in AD. Theres no difference between normal aged group and young group. These results suggest that the P300 component is specifically affected by Alzheimer type dementia.

  • PDF

다채널 청각 사건관련전위 P300 결정에서 전부위장력측정법과 전통적방법의 비교 (Comparison of Global Field Power Measurement and Conventional Method in Multi-channel Auditory Event Related Potential P300 Determination)

  • 전양환;한상익
    • 생물정신의학
    • /
    • 제7권2호
    • /
    • pp.180-185
    • /
    • 2000
  • Objective : The present study was designed to compare Global Field Power Measurement and conventional method in P300 determination. Method : The subjects were composed of patients(N=20) with schizophrenia by DSM-IV and normal controls(N=20). The auditory event related potential P300 was measured by "oddball paradigm". P300 components were determined by Global Field Power Measurement and conventional method at 5 electrodes(Fz, Cz, Pz, $T_3$, $T_4$). Results : P300 amplitudes of patients were smaller than those of controls across all electrodes and in both methods, but there was no differential power in P300 determination between two methods. Asymmetry of auditory event-related potential P300 was not shown between patients with schizophrenia and normal controls. Conclusion : It is implicated that it depends on clinical situations and research purposes what method of P300 determination will be more appropriate for patients with schizophernia.

  • PDF

시각적 MMN(vMMN)의 분석을 통한 한국어 글말의 무의식적인 인지과정 연구 (Automatic cognitive processing of korean written language as indexed by visual MMN(vMMN))

  • 이성은
    • 한국정보과학회 언어공학연구회:학술대회논문집(한글 및 한국어 정보처리)
    • /
    • 한국정보과학회언어공학연구회 2009년도 제21회 한글 및 한국어 정보처리 학술대회
    • /
    • pp.67-72
    • /
    • 2009
  • ERP의 일종인 MMN(Mismatch Negativity)은 언어의 청각 인지정보 처리과정(central auditory processing)을 규명하는 데 유용한 수단으로 이용되어 왔다. 그런데, 최근의 연구들은 이러한 MMN이 청각 자극뿐만 아니라 시각 자극에 의해서도 검출될 수 있음을 밝혀냈다. 본 연구는 이러한 시각적 MMN을 이용하여 뇌에서 이루어지는 한국어 화자의 무의식적인 한국어 문자 정보처리과정을 규명하려고 시도하였다. 본 연구에서는 한국어의 글말 최소쌍 '므'/'모'와 '므'/'무', 이에 대응되는 비언어자극 '+ㅡ'/'+ㅗ'와 '+ㅡ'/'+ㅜ'(+표시의 아래에 모음을 붙여서 만든 인공문자, 그림1 참고)를 수동적(passive) Oddball paradigm으로 제시하고 언어 자극에 대한 EEG를 비언어자극과 비교 하에 측정, 분석하였다. 본 연구의 결과, 언어자극과 비언어자극 모두에서 시각적 MMN이 검출되었다. 하지만, 언어자극의 시각적 MMN이 비언어자극의 시각적 MMN보다 높게 나타남을 확인하였다. 이는 한국어 모국어화자들이 무의식적인 인지과정에서 언어자극이 갖는 물리적인 시각 정보뿐만 아니라 한국어 문자의 언어적 정보도 함께 처리하고 있음을 보여주는 것이다. 본 연구의 결과들은 한국어 글말의 무의식적인 인지처리과정을 밝혀주는 한편, 한국어 문자가 인지과학에서 갖는 중요한 지위를 보여줄 수 있을 것으로 기대된다.

  • PDF

강박증 환자에서의 Mismatch Negativity 이상에 관한 연구 (Abnormal Mismatch Negativity in Patients with Obsessive-Compulsive Disorder)

  • 장준환;신경순;손준희;권준수
    • 대한불안의학회지
    • /
    • 제6권1호
    • /
    • pp.31-36
    • /
    • 2010
  • Objective : Mismatch negativity (MMN) provides an electrophysiological index of an involuntary attention switching process. This study investigated MMN anomalies and their relationship to clinical variables in patients with obsessive-compulsive disorder (OCD). Methods : Study participants were 29 OCD patients and 24 normal controls. We used a 128-channel EEG to measure MMN during a passive oddball paradigm. Then we assessed the correlations between MMN amplitudes and clinical measures. Results : The OCD patients exhibited significantly greater MMN amplitude compared to the controls. Also, the right frontal lobe MMN amplitudes correlated significantly to the OCD patients' Yale-Brown Obsessive Compulsive Scale total scores (r=-0.520, p=0.005). Conclusion : These results suggest that MMN anomalies in OCD patients reflect a monitoring circuit dysfunction, raising the possibility that the OCD's pathophysiology includes glutamatergic dysfunction.