• Title/Summary/Keyword: occupants

Search Result 501, Processing Time 0.025 seconds

Tendency Analysis of Indoor Natural Ventilation by PST(Particle Streak Tracking) System (PST(Particle Streak Tracking)시스템을 통한 실내자연환기 경향분석)

  • Lee, Keon-Ho;Kim, Hyeon-Soo;Jang, Dae-Hee;Son, Young-Joo
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.9-15
    • /
    • 2007
  • Ventilation of buildings provide occupants with comfort and plays a very informant role in supplying indoor ventilation requirement. Also, natural ventilation is more comfortable than forced ventilation taking account of mental comfort. Especially factors, airflow velocity and direction etc., should be reflected in establishment of comfortable indoor environment because indoor airflow can directly affect comfort of occupants. However, a device which enables indoor air movement to be analyzed has not existed until now. Hence, it has mostly depended on simulation results of fluid analysis but the results often differ far from reality. PST(Particle-Streak-Tracking) System, an alternative to improve this problem, is currently applied to natural ventilation in building, air conditioning, and airflow analysis in the inside of a plane etc. This study closely examine the property and strength and weakness of PST that is first introduced into KICT and then evaluate applicable possibility.

A Study on Determination of Poiling Period of Daylight Responsive Dimming Systems (광센서 조광제어시스템의 폴링주기 결정에 관한 연구)

  • Hwang, Min-Gu;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.213-216
    • /
    • 2005
  • Recently, energy depleting problem have risen seriously. Many studies of daylight responsive dimming system for saving of lighting energy in office buildings have been done actively. Most of studies are focused on the accuracy. However if the variation of dimming levels is changed too often, occupants would feel uncomfortable. First, illuminance changes which occupants couldn't detect are studied through analyzing foreign studies. Second, workplan illuminance from daylight in each sky condition is measured. Because the dimming level In daylight responsive dimming system is dependent on the workplan illuminance from daylight. In conclusion, the most appropriate polling periods to daylight responsive dimming system for occupant's visual comfort was determined.

  • PDF

Dynamic Relationship between Social Integration and Social Capital in the Residential Redevelopment Districts Based on the System Thinking Perspectives (시스템사고로 본 주택 재개발 지역의 사회 통합과 사회적 자본과의 동태적 관계)

  • Kim, Byung-Suk
    • Korean System Dynamics Review
    • /
    • v.11 no.4
    • /
    • pp.61-76
    • /
    • 2010
  • The purpose of this paper is to review relationship between social integration and social capital in the residential redevelopment districts based on the system thinking perspective using causal loop analysis. The results are as follows. First, social exclusion phenomena brings about relative deprivation for rental housing occupants feeling left out and close by area residents. This acts as a motive triggering antisocial activities for the rental housing occupants. Second, rental housing and housing for installment should be mix-developed to improve social exclusion phenomenon issues. Third, increase of creating work program in the relationship between residential redevelopment districts and social capital boosts employments, individual earnings, and local area investments. The conclusion provides some research implications and future research direction.

  • PDF

Economic Study on Heating load by Balcony Remodeling in use of Energy Simulation Program (에너지 시뮬레이션을 이용한 발코니 개조에 따른 난방부하 경제성 고찰)

  • Kim, Sung-Woo;Park, Sang-Hyun;Lim, Jung-Hee;Kim, Byung-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.801-806
    • /
    • 2006
  • Balcony space effects indoor thermal environment. When balcony is extended, problems would be made such as noise, dew condensation, over heating energy, and etc. Extend of balcony increase heating load about 47%. occupants must consider remodeling for their balcony. This paper compare extended balcony with unextended balcony on heating load in use of energy simulation program. According to increase heating load, we expected that building heating cost would be increased by extend balcony. To consider extend balcony, occupants must be funished with better date between healing cost increasing and floor area increasing.

  • PDF

Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS) (개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가)

  • 최익순;정광섭;박영철;한화택;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

Proposing a simple procedure for predicting the acoustical conditions in occupied classrooms from the measured unoccupied values (공석 시 측정값을 활용한 만석 시 강의실의 음향상태 예측법)

  • Ahn, Jae-Young;Choi, Young-Ji
    • Journal of Industrial Technology
    • /
    • v.41 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • This work proposes a simple method to use the added absorption per person values to predict the expected values of the acoustical conditions in occupied classrooms. This method is based on the effects of the values of added absorption per person on the unoccupied total absorption values of the classrooms and on other room acoustical parameters. The total sound absorption in an unoccupied classroom can be calculated from measured reverberation times in the classroom. The expected occupied absorption can be calculated using equation which was obtained in a previous study (Choi, 2017) by fitting a linear regression line to a plot of total occupied absorption versus the corresponding unoccupied total absorption values measured in 12 university classrooms. The ratios of occupied-to-unoccupied sound absorption are used to predict increments in the values of acoustical parameters that result when occupants are added to the rooms.

Methods for Government Housing Regulation of Residential Mortgage Loan related to Remodeling (리모델링 주택담보대출 규제의 효과적 운영방안)

  • Lee, Ji-Hyung;Lee, Min-Joo;Cho, Kyu-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.182-183
    • /
    • 2019
  • The amount of multi-aged housing more than 15 years since the completion has increased, and the real estate market caused by apartment remodeling has also increased. The domestic mortgage loan regulation on relocation expense caused by remodeling apply to same limit as that for mortgage loan newly-built apartment. The excessive government housing regulation could be an obstacle for the occupants residential stability of remodeling apartment. To suggest methods for government housing regulation of residential mortgage loan related to remodeling, examples for mortgage loan regulation and mortgage products were studied and compared. It is pointed out that regulation on occupants relocation expense caused by remodeling has to be relaxed and mortgage product development are needed to boost remodeling project.

  • PDF

A Study on Fire and Evacuation in the Public Relations Room of Waste Treatment Facilities (폐기물 처리시설 홍보실내 화재 및 피난에 관한 연구)

  • Lee, Jae-Young;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.17-22
    • /
    • 2021
  • The public relations room of the waste disposal facility is a space that can be visited by a large number of unevaluated personnel. Therefore, it is essential to design against fire, and research on fire and evacuation is essential. In this study, in order to evaluate the safety of the occupants in the event of fire and evacuation based on the life safety standards of occupants, the increase in risk due to heat, visible distance, and toxic gases on a plane 1.8m from the floor, which is the limit of breathing of the evacuee, over time. It was analyzed by location. As a result, the RSET of the P-01 exit was 93.0 seconds and the ASET was 272.6 seconds, the RSET of the P-02 exit was 45.8 seconds, the ASET was 147.7 seconds, the RSET of the P-03 exit was 106 seconds, and the ASET was 182.9 seconds.

Analysis on the Characteristics of Energy Use Behaviors and Energy Saving Consciousness of Multi-family Housing Residents (공동주택 거주자의 에너지 사용행태 및 에너지 절약의식 분석)

  • Lee, Youn-Jae;Lee, Hyun-Soo;Park, So-Yun
    • Journal of the Korean housing association
    • /
    • v.22 no.6
    • /
    • pp.31-42
    • /
    • 2011
  • The purpose of the study was to investigate the characteristics of energy use behaviors and energy saving consciousness of multi-family housing residents. The energy referred to in this study includes electric energy, heating energy and water usage. This study was conducted from a survey carried out in Seoul and Gyeonggi-do. The results of the study are as follows: First, among the survey questions, the only positive energy saving behaviors shown by the occupants was turning off the lights and the television, and in the use of kitchen appliances; it could therefore be concluded that, in general, energy saving attitude and consciousness were not sufficient to reduce energy consumption. Second, the results showed high mean scores for the behaviors which were easy to control, such as turning off lights and televisions, and low mean scores for the behaviors which required extra effort to completely cut off electricity energy such as pulling out the plugs of electronic appliances. Third, it was found that the occupants generally showed the tendency to save heating energy. However, in cases where the occupants were required to continuously and directly experience indoor temperatures, they expressed passive attitudes toward saving energy. Fourth, they showed wasteful attitudes toward water usage by leaving the tap running when taking showers and washing their faces. Fifth, while they showed a strong energy saving consciousness, they also showed a passive attitude about putting this into practice; there was therefore some gap between attitude and behavior. Lastly, among the socio-demographic factors, age and family lifecycle were very important factors affecting energy use and energy saving consciousness.

Estimating occupied university classroom acoustical parameters from unoccupied values (대학 강의실의 공석 시 측정값을 이용한 만석 시 음향지표의 예측)

  • Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.343-348
    • /
    • 2018
  • This paper proposes a simple procedure for estimating the acoustical parameter values in an occupied classroom from measurements in the unoccupied classroom. The total sound absorption in an unoccupied classroom can be calculated from measured reverberation times in the room. The expected occupied absorption can be calculated using equation that was obtained in a previous study (Choi, 2016) by fitting a linear regression line to a plot of total occupied absorption versus the corresponding unoccupied total absorption values measured in 12 university classrooms. The ratios of occupied-to-unoccupied sound absorption are used to predict increments in the values of acoustical parameters when occupants are added to the rooms. Occupied values of acoustical parameters can be estimated from unoccupied values and the change in total room absorption due to adding occupants.