• 제목/요약/키워드: occupants

검색결과 504건 처리시간 0.022초

QFD를 적용한 아파트 거주후평가에 관한 연구 (A Study of POE on Apartment with QFD Application)

  • 서경화;박영원;심우갑
    • 품질경영학회지
    • /
    • 제29권4호
    • /
    • pp.161-169
    • /
    • 2001
  • Recently, the quality of residential space is emphasized much more than ever. This is caused by various changes of social environment. Those users, i.e. the occupants, seemed very sensitive to any changes of their environment. Therefore many producers (construction companies) need to be concentrated on the occupant's needs, and try to apply those needs to their design of products(apartments). This study aims to design the POE(Post Occupancy Evaluation) categorization methodology with QFD application. Therefore QFD performed to produce much tailored occupant's needs as a transformation of technically processed value. For this purpose, categories were experimented for a pilot project of POE. As a result, it showed a possibility and need of accuracy and maturity for the design of POE in its categorization.

  • PDF

수음실 내 구조체의 진동량 계측을 통한 바닥충격음레벨 예측 (Prediction of Floor Impact Sound by Measuring the Vibration Acceleration Level on the Interior Structures of Receiving Room in Apartment Buildings)

  • 김명준;김흥식;김하근
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.3-9
    • /
    • 2003
  • In an apartment building, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation. it is nesessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to investigate the applicability of the theory of sound radiation. We measured the vibration acceleration levels on the interior structures and predicted the sound pressure level of the room by using them. The result show that the predicted value, in general, were in good agreement with the measured values within 5∼10% in error rate.

국부정면충돌 시험방법에 관한 실험적 연구 (Experimental Study on the Small Overlap Frontal Crash Test Method)

  • 김대업;우창기
    • 한국생산제조학회지
    • /
    • 제26권2호
    • /
    • pp.205-213
    • /
    • 2017
  • In order to improve occupant protection in frontal crash, the IIHS introduced a small overlap frontal crash test in 2012. When the front corner of a car collides with another car or object, such as utility pole the test replicated the sequence of events. Because occupants move simultaneously forward and toward the side of the vehicle this test is challenging for some airbag and safety belt designs. In the small overlap frontal test, a car travels at 64 km/h toward a rigid barrier. A hybrid III dummy is positioned in the driver seat. 25% of the total width of the car strikes the barrier on the driver side. After review of small overlap frontal test protocol and overall rating, six run-throughs were performed according to the original test method.

EXODUS, SIMULEX를 활용한 피난모델 분석에 관한 연구 (A Study on the Egress Model Analysis using EXODUS, SIMULEX)

  • 서동구;황은경;황금숙;조정훈;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.33-36
    • /
    • 2008
  • Recently with the increasing economics, many hish-rise and complicated building with new architecture features are constructed in Korea. These higher and bigger building have many difficulties of fire safety concerns, especially evacuation plan. In this paper, aims to present logical basis for forecasting egress behavior of occupants and systematized Egress-Prediction Model by analysing expectable decisive factors among influential factors each step until completing egress from perception of fire cues.

  • PDF

TLC와 컬러화상처리를 이용한 자동차 실내 환기유동의 온도장 측정 (Temperature Field Measurement of Ventilation Flow in a Vehicle Interior)

  • 윤정환;이상준;김기원
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.120-128
    • /
    • 1997
  • The variations of the temperature field in a passenger compartment were measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. This temperature measurement technique was proved to be useful for analyzing the ventilation flow. The flow field in the passenger compartment was visualized using a particle streak method with pulsed laser light sheet. The temperature field and flow field in the passenger copartment were affected significantly by the ventilation mode. The panel-vent mode heating had shorter elapse time to reach a uniform temperature than the foot-vent mode under the same ventilation condition and nonuniformity inside the passenger compartment could be minimized effectively by using the bilevel heating mode. The temperature increase rate in the rear passenger compartment was iower than the front compartment, especially in the vicinity of the rear seat occupants' knee level.

  • PDF

자동차 에어백용 원단의 수명예측 (Lifetime Prediction of Automotive Airbag Fabrics)

  • 구현진;조항원;장갑식
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권4호
    • /
    • pp.319-329
    • /
    • 2009
  • The airbag module is an inflatable restraint system that inflates within 0.05 seconds automatically in a collision to protect the occupants. The airbag fabrics used in the module are required to have the good resilience and strength and also to have retained at least 80% of mechanical properties after using longer than 10 years. In this study, we develop an accelerated test method in order to predict the lifetimes of airbag. In this test, we select temperature and humidity as environmental stresses by analyzing the failure mechanisms of coated and uncoated nylon 66 fabrics. It is found that the degradation of airbag fabrics is effectively accelerated under the combined conditions of high temperature and humidity. Analyzing the results of the accelerated test, the lifetimes of airbag fabrics are predicted to be longer than 10 years.

  • PDF

동적 LED 조명 시스템의 개발에 대한 연구 (Research on Development of a dynamic LED lighting system)

  • 최종대;김효인;윤근영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.168-173
    • /
    • 2011
  • Recently, from a saving energy and environmental lighting sources point of view, using LED lighting have been increased rapidly. The colors of light was applied to the control of dimmers that is composed of red, green, blue, and white(RGBW) to improve the quality of visual environment. Moreover this study has been processed to develop adjustable dynamic LED lighting system on SPD and definitize the various spectral power distribution and color temperature of light through the control of the four dimmers. It is possible to combine up to $432^4$ kinds of light. Measurement of illuminance of range on working surface was as 7~l,831 lux. Application of visual environment for occupants can be expected according to control of lighting performance.

  • PDF

주거 건물의 설계 및 시공단계를 고려한 실내공기질 평가 프로그램 개발에 관한 연구 (Development of Home Indoor Air Quality evaluation program considering planning and construction stage)

  • 최동희;강동화;김선숙;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.51-56
    • /
    • 2005
  • The objective of this study is to develop Home Indoor Air Quality evaluation prorgram considering planning and construction stage for architects, engineers and occupants to estimate and improve the IAQ of a home. In this study, the IAQ modeling technique was discussed to determine the appropriate modeling of housing unit in Korea. The program algorithm was developed based on the selected model reflecting planning and construction stage. This program can be applied to estimate the IAQ of a home and encourage appropriate action in advance.

  • PDF

공조취출방식에 따른 공기의 나이 및 환기효율 비교 (Comparison of age of air and air change effectiveness between supply diffuser types)

  • 조동우
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

보행하중을 받는 건축물 바닥판의 진동해석 (Vibration Analysis of Building Floor Subjected to Walking Loads)

  • 김기철;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.414-421
    • /
    • 2001
  • Recently, the damping effect of building structures are greatly reduced because the use of non-structures members as like curtain wall are decreased and large open space are in need for the service of buildings. Assembly and office buildings with a lower natural frequency have a higher possibility of experiencing excessive vibration induced by human activities as like jumping, running and walking. These excessive vibration make the occupants uncomfortable and the serviceability deterioration. The common method of application of walking loads for the vibration analysis of structures subjected to walking loads is to inflict a series unit walking load and a periodic function at a node. But this method could not consider the moving effect of walking. In this study, natural frequency and damping ratio of plate structure are evaluated by heel drop tests. And new application of equivalent walking loads are introduced for vibration analysis of real slab system subjected to walking loads. The response obtained from the numerical analysis are compared well to the results measured by experimental tests. It is possible to efficiently analyze the vibration of floor which is subjected to walking loads by applying equivalent walking loads.

  • PDF