• Title/Summary/Keyword: observed structural behavior

Search Result 523, Processing Time 0.033 seconds

Rheological Characteristics of Germinated Corn Starch (발아 옥수수 전분의 리올로지 특성)

  • Yang, Young-Kook;Lee, Shin-Young;Choi, Kook-Chi
    • Applied Biological Chemistry
    • /
    • v.29 no.4
    • /
    • pp.339-345
    • /
    • 1986
  • Rheological characteristics of starch isolated from germinated corn were investigated and compared with those of nongerminated corn starch. Flow behavior of both starches were Bingham psudoplastic. Consistency index and yield stress of germinated starch solution were lower than those of nongerminated starch solution, while flow behavior index was nearly similar. Concentration dependency of both starch solutions were similar to each other but lower temperature dependency of germinated starch solution was observed. Time dependent characteristics of both starches showed thixotropic behavior, but due to germination, germinated starch showed higher structural decay under shear than nongerminated starch and its elastic properties was weaker.

  • PDF

The Characteristics of Fatigue Cracks Emanating from Small Hole Defects Located Opposite Position of the Shaft Cross Section (축단면 내 대칭위치에 존재하는 원공결함에서 발생하는 피로균열 거동)

  • Song, Sam-Hong;An, Il-Hyeok;Lee, Jeong-Mu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.84-91
    • /
    • 2002
  • The shaft with the circular cross section have symmetric structural combination parts to keep the rotating balance. Hence the crack usually emanate from symmetric combination parts due to the stress concentration of these parts. In this study to estimate the fatigue behavior of symmetric cracks, the fatigue test was performed by using rotary bending tester and the specimen with symmetric defects in circular cross section. From the facts the characteristics of crack initiation and propagation on the symmetric surface cracks in circular cross section was examined. Also we observed the internal crack using oxidation coloring and investigated the fatigue behavior using the relationship between surface crack and internal crack. As a result of fatigue lift of symmetric cracks was reduced to 35% compared to single crack’s. We examined the characteristics of fatigue behavior in element with symmetric cracks using internal crack propagation rate and maximum stress intensity factor range obtained from approximation method.

Behavioral Characteristics of Fatigue Cracks in Small Hole Defects Located on Opposite Sides of the Shaft Cross Section

  • Sam-Hong;Il-Hyuk;Jeong-Moo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.4
    • /
    • pp.36-42
    • /
    • 2004
  • The shaft with the circular cross section has symmetric structural combination parts to keep the rotating balance. Hence the crack usually initiates from symmetric combination parts due to the stress concentration of these parts. In this study to estimate the fatigue behavior of symmetric cracks, the fatigue test was performed by using a rotary bending tester and the specimen with symmetric defects in circular cross section. The characteristics of crack initiation and propagation on the symmetric surface cracks in circular cross section were examined. We also observed the internal crack using the oxidation coloring method and investigated the fatigue behavior using the relationship between the surface crack and the internal crack. As a result, the fatigue life of symmetric cracks was reduced by 35% compared to that of a single crack. We examined the characteristics of fatigue behavior of elements with symmetric cracks using internal crack propagation rate and maximum stress intensity factor range that were obtained from an approximation method.

Observation of Unusual Structural Phase Transition in $VO_2$ Thin Film on GaN Substrate

  • Yang, Hyeong-U;Son, Jeong-In;Cha, Seung-Nam;Kim, Jong-Min;Gang, Dae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.573-573
    • /
    • 2012
  • High quality $VO_2$ thin films were successfully grown on GaN substrate by optimizing oxygen partial pressure during the growth using RF sputtering technique. The $VO_2$ thin film grown on GaN substrate exhibited an unusual metal insulator transition behavior, which was known to be observed only either in doped sample or under uniaxial stress. Raman spectra also confirmed that metal insulator transition occurred from monoclinic M1 to rutile R phase via monoclinic M2 phase with increasing temperature. We believe that large lattice mismatch between $VO_2$ and GaN substrate may cause M2 phase to be thermodynamically stable. Optical transmittance and its electrical switching behavior were carefully investigated to elucidate the underlying physics of its metal insulator transition behavior. This study may lead to a unique opportunity to better understand the growth mechanism of M2 phase dominant $VO_2$ thin films.

  • PDF

The Relationships between Emotion Display Rule and Nurse's Job Attitudes;Mediation Effects of Negative Emotion Suppress and Inauthenticity (정서표현규범과 간호사의 직무태도의 관계;부정정서억제와 가식의 매개효과)

  • Park, Jung-Ae;Han, Tae-Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.2
    • /
    • pp.213-224
    • /
    • 2006
  • Purpose: This study examined Korean nurses' job attitude (i.e., satisfaction and burnout) regarding the extent to which organization's emotion display rule influences on job attitudes through emotion-related variables (i.e., negative emotion suppress behavior and inauthenticity), thereby examining mediation effects of negative emotion suppress behavior and inauthenticity. Method: Using a survey to nurses working in various general hospitals in Korea, structural equation modeling was adopted. Result: Emotion display rule affected outcome variables but these effects were mostly observed via the two mediators, negative emotion suppress and inauthenticity, which largely supports the research model. Conclusion: Individuals who perceived stronger emotional display rule suppressed more their negative emotion, and also perceived more inauthenticity. In turn, negative emotion suppress behavior only affected job burnout positively. Inauthenticity showed a negative effect on job satisfaction while it had a positive effect on burnout. The study provided directions for future research and practical implications to help nurses' effective job performance.

  • PDF

Effect of introducing RC infill on seismic performance of damaged RC frames

  • Turk, Ahmet Murat;Ersoy, Ugur;Ozcebe, Guney
    • Structural Engineering and Mechanics
    • /
    • v.23 no.5
    • /
    • pp.469-486
    • /
    • 2006
  • The main objective of this study was to investigate the seismic behavior of damaged reinforced concrete frames rehabilitated by introducing cast in place reinforced concrete infills. Four bare and five infilled frames were constructed and tested. Each specimen consisted of two (twin) 1/3-scale, one-bay and two-story reinforced concrete frames. Test specimens were tested under reversed-cyclic lateral loading until considerable damage occurred. RC infills were then introduced to the damaged specimens. One bare specimen was infilled without being subjected to any damage. All infilled frames were then tested under reversed-cyclic lateral loading until failure. While some of the test frames were detailed properly according to the current Turkish seismic code, others were built with the common deficiencies observed in existing residential buildings. The variables investigated were the effects of the damage level and deficiencies in the bare frame on the seismic behavior of the infilled frame. The deficiencies in the frame were; low concrete strength, inadequate confinement at member ends, 90 degree hooks in column and beam ties and inadequate length of lapped splices in column longitudinal bars made above the floor levels. Test results revealed that both the lateral strength and lateral stiffness increased significantly with the introduction of reinforced concrete infills even when the frame had the deficiencies mentioned above. The deficiency which affected the behavior of infilled frames most adversely was the presence of lap splices in column longitudinal reinforcement.

Simulation of the behaviour of RC columns strengthen with CFRP under rapid loading

  • Esfandiari, Soheil;Esfandiari, Javad
    • Advances in concrete construction
    • /
    • v.4 no.4
    • /
    • pp.319-332
    • /
    • 2016
  • In most cases strengthening reinforced concrete columns exposed to high strain rate is to be expected especially within weak designed structures. A special type of loading is instantaneous loading. Rapid loading can be observed in structural columns exposed to axial loads (e.g., caused by the weight of the upper floors during a vertical earthquake and loads caused by damage and collapse of upper floors and pillars of bridges).Subsequently, this study examines the behavior of reinforced concrete columns under rapid loading so as to understand patterns of failure mechanism, failure capacity and strain rate using finite element code. And examines the behavior of reinforced concrete columns at different support conditions and various loading rate, where the concrete columns were reinforced using various counts of FRP (Fiber Reinforcement Polymer) layers with different lengths. The results were compared against other experimental outcomes and the CEB-FIP formula code for considering the dynamic strength increasing factor for concrete materials. This study reveals that the finite element behavior and failure mode, where the results show that the bearing capacity increased with increasing the loading rate. CFRP layers increased the bearing capacity by 20% and also increased the strain capacity by 50% through confining the concrete.

A numerical investigation of the tensile behavior of the thread-fixed one-side bolted T-stubs at high temperature

  • You, Yang;Liu, Le;Jin, Xiao;Wang, Peijun;Liu, Fangzhou
    • Steel and Composite Structures
    • /
    • v.45 no.4
    • /
    • pp.605-619
    • /
    • 2022
  • The tensile behavior of the Thread-fixed One-side Bolt (TOB) at high temperatures was studied using the Finite Element Modeling (FEM) to explore the structural responses that could not be measured in tests. The accuracy of the FEM was verified using the test results from the failure mode, load-displacement curve as well as yielding load. Three typical failure modes of TOB connected T-stubs were observed, which were the Flange Yielding (FY), the Bolt Failure (BF) and the Coupling Failure mode (CF). The influence of the flange thickness tb and the temperature θ on the tensile behavior of the T-stub were discussed. The initial stiffness and the yielding load decreased with the increase of the temperature. The T-stubs almost lost their resistance when the temperature exceeded 700℃. The failure modes of T-stubs were mainly decided by the flange thickness, which relates to the anchorage of the hole threads and the bending resistance of flange. The failure mode could also be changed by the high temperature. Design equations in EN 1993-1-8 were modified and verified by the FEM results. The results showed that these equations could predict the failure mode and the yielding load at different temperatures with satisfactory accuracy.

Measurement of Structural Properties of PLA Filament as a Supplier of 3D Printer (3D 프린터에 공급되는 PLA 필라멘트의 물성치 측정)

  • Choi, Won;Woo, Jae-Hyeong;Jeon, Jeong-bae;Yoon, Seong-soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.141-152
    • /
    • 2015
  • Most of agricultural structures are consisted of complex components and exposed to various boundary conditions. There have been no ways to express those structures exactly for model experiment. As an alternative, 3D printer can produce any type of solid model. However, there are limited informations related to structural experiments using 3D printer. The object of this study gives the basic informations to structural engineers who try to use 3D printer for model experiment. When PLA was used as a supplier for 3D printer, the outcomes showed less heat deformation to compare with ABS. To test the material properties, two kinds of experiments (three-point flexibility test and compression test) were executed using universal testing machine. In three-point flexibility test, plastic hinge and its deformation were developed as observed in material such as steel. The behavior was in a linear elastic state, and elastic bending modulus and yield force were evaluated. In the compression test using unbraced columns with hinge-hinge boundary condition, the constant yield forces were observed regardless of different lengths in all columns with same section size, whereas the compressive elastic modulus was increased as the length of column was increased. The suggested results can be used for model experiments of various agricultural structures consisted of single material.

Thermo-mechanical analysis of reinforced concrete slab using different fire models

  • Suljevic, Samir;Medic, Senad;Hrasnica, Mustafa
    • Coupled systems mechanics
    • /
    • v.9 no.2
    • /
    • pp.163-182
    • /
    • 2020
  • Coupled thermo-mechanical analysis of reinforced concrete slab at elevated temperatures from a fire accounting for nonlinear thermal parameters is carried out. The main focus of the paper is put on a one-way continuous reinforced concrete slab exposed to fire from the single (bottom) side as the most typical working condition under fire loading. Although contemporary techniques alongside the fire protection measures are in constant development, in most cases it is not possible to avoid the material deterioration particularly nearby the exposed surface from a fire. Thereby the structural fire resistance of reinforced concrete slabs is mostly influenced by a relative distance between reinforcement and the exposed surface. A parametric study with variable concrete cover ranging from 15 mm to 35 mm is performed. As the first part of a one-way coupled thermo-mechanical analysis, transient nonlinear heat transfer analysis is performed by applying the net heat flux on the exposed surface. The solution of proposed heat analysis is obtained at certain time steps of interest by α-method using the explicit Euler time-integration scheme. Spatial discretization is done by the finite element method using a 1D 2-noded truss element with the temperature nodal values as unknowns. The obtained results in terms of temperature field inside the element are compared with available numerical and experimental results. A high level of agreement can be observed, implying the proposed model capable of describing the temperature field during a fire. Accompanying thermal analysis, mechanical analysis is performed in two ways. Firstly, using the guidelines given in Eurocode 2 - Part 1-2 resulting in the fire resistance rating for the aforementioned concrete cover values. The second way is a fully numerical coupled analysis carried out in general-purpose finite element software DIANA FEA. Both approaches indicate structural fire behavior similar to those observed in large-scale fire tests.