• Title/Summary/Keyword: objective measurements

Search Result 1,124, Processing Time 0.025 seconds

Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis

  • Dong Wook Kim;Chong Hyun Suh;Kyung Won Kim;Junhee Pyo;Chan Park;Seung Chai Jung
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.880-893
    • /
    • 2019
  • Objective: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. Materials and Methods: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. Results: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3-3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7-11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82-0.90) and 0.93 (95% CI, 0.89-0.95), respectively, suggesting good to excellent reliability. Conclusion: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.

Factors affecting smile esthetics in adults with different types of anterior overjet malocclusion

  • Cheng, Hsin-Chung;Cheng, Pei-Chin
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.31-38
    • /
    • 2017
  • Objective: This study aimed to quantitatively assess the relationship of smile esthetic variables with various types of malocclusion, and identify the cephalometric factors affecting smile measurements. Methods: This retrospective study included 106 patients who were treated with retention at the orthodontic department of Taipei Medical University Hospital. Hard-tissue variables were measured using lateral cephalographic tracings, and nine smile esthetic variables were measured using facial photographs. The patients were divided into three groups according to their overjet (< 0, 0-4, and > 4 mm). An analysis of variance was conducted to compare the pretreatment cephalometric variables and smile esthetic variables among the three groups. Multiple linear regression analysis was performed to identify the cephalometric factors affecting the smile measurements in each group. Results: Except the upper midline and buccal corridor ratio, all of the smile measurements differed significantly among the three groups before orthodontic treatment. Some of the smile characteristics were correlated with the cephalometric measurements in different types of malocclusion. The overjet was the major factor influencing the smile pattern in all three types of malocclusion. Conclusions: Smile characteristics differ between different types of malocclusion; the smile may be influenced by skeletal pattern, dental procumbency, or facial type. These findings indicate that establishment of an optimal horizontal anterior teeth relationship is the key to improving the smile characteristics in different types of malocclusion.

Differences in electric potential of meridian system(5) - Comparing electrical potentials of patients with shoulder lesions - (견비통 환자의 침 치료 전후 12경맥 전위측정 연구(5))

  • Nam, Bong-hyun;Choi, Hwan-soo
    • Journal of Acupuncture Research
    • /
    • v.19 no.6
    • /
    • pp.12-23
    • /
    • 2002
  • Objective : Assuming That the Characteristic of Meridian System Has been Similar to This of Electric Potentials in Human Body And that Measurements of Electric Potential at Well(井穴) and Sea(合穴) Points in Branches of the Twelve Meridians(WSBTM) Will Be Representative of Measurements of the Twelve Meridians, to Measure the Electric Potentials of 21 Patients with Shoulder Lesions, And Aching of Shoulder and Arm(肩臂痛)(ASA), to Be Differences in Electric Potentials of Patients Between Before And After Acupuncture Treatment, And Then to Find out the Characteristic of Meridian System in Patients with Shoulder Lesions. Methods : Electric Potentials of Well And Sea Points in the Meridians in Twenty one Patients with ASA Diagnosed by Both x-ray And Self View on Pain at Shoulder And Arm were Repeatedly Measured by Physiograph(PowerLab) at Before And after Acupuncture Treatment, Respectively. Measurements of Those Electrical Potentials Were Analyzed by Factor Analysis. Results : The Electric Potentials of WSBTM At the Left Side Before Acupuncture Treatment Were Divided Into Five Factors, But Those After Acupuncture Treatment Were Done Into Four Factors. On The Other Hand Those At the Right Side Before Acupuncture Treatment Were Divided Into Four Factors, The Number of Factors After Acupuncture Treatment Was Five. Conclusions : In Conclusions, The Number of Factors Before Acupuncture Treatment Are Different from Those After Acupuncture Treatment. In the Results The Effect of Acupuncture Treatment May be Reflected in Measurements of Electric Potential at WSBTM.

  • PDF

Investigation of the effects of temporomandibular joint arthrocentesis on blood volume of the retinal structures

  • Keskinruzgar, Aydin;Cankal, Dilek Aynur;Koparal, Mahmut;Simsek, Ali;Karadag, Ayse Sevgi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Objective: Arthrocentesis is a minimally invasive surgical procedure that is used to alleviate the symptoms of temporomandibular joint (TMJ) disorders. The aim of this study was to investigate the effect of arthrocentesis on the blood supply to the retinal structures. Materials and Methods: Arthrocentesis was performed on 20 patients with TMJ disorders, and choroidal thickness (CT) in patients was measured to evaluate retinal blood circulation. The blood volume of the retinal structures was evaluated ipsilaterally before and after arthrocentesis, and these measurements were then compared with measurements obtained from the contralateral side. Results: Before arthrocentesis, there were no differences in retinal blood volumes between the ipsilateral and contralateral sides (P = 0.96). When ipsilateral CT measurements taken before and after arthrocentesis were compared, retinal blood supply was found to have significantly decreased after arthrocentesis (P = 0.04). When contralateral CT measurements taken before and after arthrocentesis were compared, retinal blood supply was also found to have decreased after arthrocentesis, but not significantly (P = 0.19). Conclusion: The solution of local anesthesia with epinephrine applied before the arthrocentesis procedure was found to reduce the blood volume of the retinal structures. To the best of our knowledge, this is the first study that has investigated the blood volume of the retinal structures following arthrocentesis.

Long-term stability of maxillary and mandibular arch dimensions when using rapid palatal expansion and edgewise mechanotherapy in growing patients

  • Kim, Ki Beom;Doyle, Renee E.;Araujo, Eustaquio A.;Behrents, Rolf G.;Oliver, Donald R.;Thiesen, Guilherme
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.89-96
    • /
    • 2019
  • Objective: The purpose of this study was to assess the long-term stability of rapid palatal expansion (RPE) followed by full fixed edgewise appliances. Methods: This study included 67 patients treated using Haas-type RPE and non-extraction edgewise appliance therapy at a single orthodontic practice. Serial dental casts were obtained at three different time points: pretreatment ($T_1$), after expansion and fixed appliance therapy ($T_2$), and at long-term recall ($T_3$). The mean duration of the $T_1-T_2$ and $T_2-T_3$ periods was $4.8{\pm}3.5years$ and $11.0{\pm}5.4years$, respectively. The dental casts were digitized, and the computed measurements were compared with untreated reference data. Results: The majority of treatment-related increases in the maxillary and mandibular arch measurements were statistically significant (p < 0.05) and greater than expected for the untreated controls. Although many measurements decreased postretention ($T_2-T_3$), the net gains persisted for all of the measurements evaluated. Conclusions: The use of RPE therapy followed by full fixed edgewise appliances is an effective method for increasing maxillary and mandibular arch width dimensions in growing patients.

Comparison of Predicted Acoustics with the Measured Acoustic Properties of a Multi-Purpose Hall

  • Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.3E
    • /
    • pp.95-100
    • /
    • 2006
  • The present study presents the design procedures and the acoustic properties of the main hall of Ansan Cultural Arts Center in Korea which has opened in 2004. The acoustic design values are compared with the measured acoustic properties of the completed multi-purpose hall. Acoustic design criteria were suggested in the design stage through the 3-dimentional computer simulations. The acoustic parameters including SPL, RT, C80, $D_{50}$M, RASTI were measured in the hall after completed. Acoustic measurements were carried out in the 40 measurement points using MLS sound source signal in 4 different sound source points. The results show the even distribution of sound levels within the 2.0dB of difference among all seats. The reverberation time of 1.66sec was measured which is similar to the objective value of 1.65 sec in empty states. It was also found that average C80 values lie in the objective extents of C80 from -1 to 3dB and average D50 value of 54 was measured. Thus, it is concluded that the hall can be used as a multi-purpose hall with a suitable acoustic conditions.

A Study on Analysis of the Physical Properties of Domestic and Foreign Sensible Worsted Fabrics - Comparison between subjective and objective hand assessments of the fabric - (국내.외 감성 소모직물의 물성분석에 관한 연구(I) - 주관적 태 평가와 객관적 태 평가 비교 -)

  • Park, Kyung-Soon;Kim, Seung-Jin
    • Science of Emotion and Sensibility
    • /
    • v.10 no.3
    • /
    • pp.299-306
    • /
    • 2007
  • The purpose of this study is to analyze physical properties of foreign famous worsted fabrics to realize improvements in qualities of the domestic men's worsted fabrics and to make an comparison between foreign worsted fabrics and domestic ones. For this purpose, this study carries out both objective and subjective fabric hand measurements using KES-FB system and Blind field test, to evaluate physical properties of worsted fabrics and finally is aiming to make an comparison between the results from the two measurements for enhancing the quality of the domestic worsted fabrics using the 14 specimens of 7 types as worsted fabrics manufactured in Italy, UK and Korea.

  • PDF

A Study on Hydrophone Array Design Optimization for Cavitation Tunnel Noise Measurements (캐비테이션 터널 시험용 청음기배열 최적 설계기법)

  • Park, Cheolsoo;Seol, Hanshin;Kim, Gundo;Park, Youngha
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.237-246
    • /
    • 2013
  • This paper proposes a hydrophone array design optimization technique for cavitation tunnel noise measurements. The optimization technique comprises of design parameters, an objective function and an optimization algorithm. The design parameters are defined for circular, spiral and multi-spiral arrays. The objective function is defined so as to consider the mainlobe beamwidth and the maximum sidelobe level simultaneously. A global optimization scheme is applied to the array design using very fast simulated reannealing (VFSR). After applying the optimization technique to arrays respectively, the peak sidelobe level and the mainlobe beamwidth of optimum arrays are analyzed. Finally the array patterns considering multiple reflections in the cavitation tunnel are evaluated to validate the proposed method.

Injury and inflammation detection by the application of microcurrent through the skin

  • Hui, Timothy;Petrofsky, Jerrold
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Objective: To determine the efficacy and reliability of measuring direct current microcurrent applied through the skin to determine injury in the underlying tissues. Design: Case control study. Methods: First, microcurrent was measured as decreased blood flow induced hypoxia in healthy subjects. Next, reliability was assessed by measuring over ten days with set variations in pressure and distance between the electrodes. Finally, measurements over sprained ankle were compared to measurements over comparable uninjured areas on the same injured subject. Results: For the blood flow test phase, microcurrent significantly decreased an average of 17% after 5 minutes (p<0.05), remained decreased for 30 seconds, and returned to non-occlusive levels after 2 minutes of normal circulation. The results indicate that the microcurrent decrease was not due to blood flow, and most likely from hypoxic cellular damage. For the reliability phase, the coefficients of variation averaged 10.3% for the shoulder, 14.8% for the low back, and 29.1% for the knee. Changing distance 2.5 cm between the electrodes resulted in insignificant changes. Changes in pressure had some significant effect after an increase in force of 2.6 N, affirming the need for consistent pressure for measurement. For the injury test phase, a significant 69% decrease occurred comparing injured areas to the same area on the uninjured side, and a significant 74% occurred comparing injured and non-injured areas on the same limb. Conclusions: Microcurrent through the skin shows promise as an objective method of assessing a soft tissue injury by detecting damage likely due to hypoxia.

  • PDF

A DNN-Based Personalized HRTF Estimation Method for 3D Immersive Audio

  • Son, Ji Su;Choi, Seung Ho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.161-167
    • /
    • 2021
  • This paper proposes a new personalized HRTF estimation method which is based on a deep neural network (DNN) model and improved elevation reproduction using a notch filter. In the previous study, a DNN model was proposed that estimates the magnitude of HRTF by using anthropometric measurements [1]. However, since this method uses zero-phase without estimating the phase, it causes the internalization (i.e., the inside-the-head localization) of sound when listening the spatial sound. We devise a method to estimate both the magnitude and phase of HRTF based on the DNN model. Personalized HRIR was estimated using the anthropometric measurements including detailed data of the head, torso, shoulders and ears as inputs for the DNN model. After that, the estimated HRIR was filtered with an appropriate notch filter to improve elevation reproduction. In order to evaluate the performance, both of the objective and subjective evaluations are conducted. For the objective evaluation, the root mean square error (RMSE) and the log spectral distance (LSD) between the reference HRTF and the estimated HRTF are measured. For subjective evaluation, the MUSHRA test and preference test are conducted. As a result, the proposed method can make listeners experience more immersive audio than the previous methods.