• Title/Summary/Keyword: number system

Search Result 20,619, Processing Time 0.041 seconds

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

Effects of Number of Heating Walls on Heat Transfer in the Rough Square Channel with Twisted Tape (테이프가 있는 거친 사각채널에서 가열벽면의 수가 열전달에 미치는 효과)

  • Ahn, S.W.;Kim, M.H.;Bae, S.T.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.17-22
    • /
    • 2006
  • Surface modifications like rib-roughening and displaced insert devices like the twisted tape are commonly used in applications such as compact heat exchangers and cooling systems. In this paper, regionally averaged heat transfer distributions in square channels with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. Regionally averaged Nusselt number and channel averaged Nusselt number in turbulent air flows are presented for Reynold numbers from 8,900 to 29,000. We have obtained the following conclusions from the experimental study: 1) The local Nusselt number in the two-sided heated case is higher than that in the four-sided heated condition. 2) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 3) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer coefficient.

  • PDF

Implementation of Number Portability for SMS on the network of VoIP (인터넷전화에서의 SMS 번호이동 서비스 구현)

  • Jeong, Moon-Soo;Hong, Wan-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.631-636
    • /
    • 2010
  • The network configuration of SMS number moving service is a very important factor to improve the user convenience to Internet Telephone. To provide the service, The SMSC system is required the the function of DB process and management of the subscriber, In case of SMSG system to interconnects with the other network and SMSC, the function of the call processing of subscriber who has changed his number by interconnecting with NPDB(Number Portability DB) is required. This paper had studied the way to consist the efficient network by the number moving technique.

A Study on Uniform of ISDN/PSTN Subscriber Telephone Number for the Service Improvement (서비스개선을 위한 ISDN/PSTN 가입자번호 통일화에 관한 연구)

  • 박광채
    • Information and Communications Magazine
    • /
    • v.11 no.2
    • /
    • pp.113-122
    • /
    • 1994
  • In this paper, We analyze and inspect the problem of our country PSTN subscriber telephone number and suggest the ISDN/PSTN subsciber numbering plan in the future. Expecially, when you eastablish plan to change present telephone number system to ISDN telephone number system, public goverment and public office which has many calls have to be given a same number that many people want and being easy rememberance thoughout the country. Therefore we think that it is saving hours and reduce lost calls. As concrete action of convert plan it must be made consistent numbering plan when the numbering reorganization is carried out in Korea before T-time. If a partial is not carried out, it should be given when the telephone number is newly-organized or the big buliding and goverment and public office eastablich RSS individually. At that time chaos will be minimized.

  • PDF

Comparison of particle size distribution and particle number concentration measured by APS 3321 and Dust Monitor 1.108 (APS 3321과 Dust Monitor 1.108을 이용한 입자 크기분포 및 수농도 측정결과 비교)

  • Lim, Kyoung-Soo;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 2009
  • The size distribution and number concentration of atmospheric aerosol were measured and compared using APS 3321 and Dust Monitor 1.108. The particle size distribution and number concentration measured by two devices were also compared at a particle generation system of standard PSL and fly ash. The number concentration of atmospheric aerosol measured by APS was higher than that by Dust Monitor in particle size range of less than $3.0{\mu}m$, but there was good accordance between them in particle size range of over $3.0{\mu}m$. In the particle generation system of PSL and fly ash, different measurement results were shown because the particle concentration was higher than that of atmospheric aerosol. The number concentration measured by Dust Monitor was higher than that by APS in most particle size ranges. However, the peak concentration of PSL particles measured by Dust Monitor was lower than that by APS. The difference of the collection efficiency in a scrubber by APS and Dust Monitor measurement was less than 10%, but in the particle size of $1.5{\mu}m$, it was over 20%.

  • PDF

The Effect of Rotation of Discharge Hole on the Discharge Coefficient and Pressure Coefficient (송출공의 회전이 송출계수와 압력계수에 미치는 영향)

  • Ha, Kyoung-Pyo;Ku, Nam-Hee;Kauh, S.Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.948-955
    • /
    • 2003
  • Pressure coefficient in rotating discharge hole was measured to gain insight into the influence of rotation to the discharge characteristics of rotating discharge hole. Pressure measurements were done by the telemetry system that had been developed by the authors. The telemetry system measures static pressure using piezoresistive pressure sensors. Pressure coefficients in rotating discharge hole were measured in longitudinal direction and circumferential direction with various rotating speed and 3 pressure ratios. From the results, the pressure coefficient, and therefore the discharge coefficient, is known to decrease with the increase of Ro number owing to the increase of flow approaching angle to the discharge hole inlet. However, there exists critical Ro number where the decrease rate of discharge coefficient with the increase of Ro number changes abruptly; flow separation occurs from the discharge hole exit at this critical Ro number. Critical Ro number increases with the increase of length-to-diameter ratio, but the increase is small where the length-to-diameter ratio is higher than 3. The decrease rate of discharge coefficient with the increase of Ro number depends on the pressure recovery at the discharge hole, and the rate is different from each length-to-diameter ratio; it has tendency that the short discharge hole shows higher decrease rate of discharge coefficient.

Effect of Number of Rough Walls on Heat Transfer in the Square Channel with a Uniform Heat Flux (일정 열유속을 가진 사각채널에서 거친 벽면의 수가 열전달에 미치는 효과)

  • Bae, S.T.;Kim, M.H.;Lee, D.H.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.30-35
    • /
    • 2005
  • Repeated ribs are used on heat exchanger surfaces to promote turbulence and to enhance convective heat transfer. Applications include fuel rods of gas-cooled nuclear reactors, inside cavities of turbine blades, and internal surfaces pipes used in heat exchangers. Despite the great number of literature papers, only few experimental data concerns detailed distributions of friction factors and heat transfer coefficients in square channels varying the number of rough walls. This issue was tackled by investigating effects of different number of ribbed walls on heat transfer and friction characteristics in square channel. The rough wall had a $45^{\circ}$ inclined square rib. Uniform heat flux was maintained on the whole inner heat transfer channel area. The heat transfer coefficient and friction factor values increased with increasing the number of rough walls.

  • PDF

Numerical analysis of heat transfer and friction factors in a duct having circular perforated baffles (원형 다공배플이 있는 덕트에서의 열전달과 마찰계수에 관한 수치해석)

  • Oh, S.K.;Ahn, S.W.;Ary, Bachtiar Krishna Putra;Bae, S.T.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.44-50
    • /
    • 2012
  • The present numerical study was performed to determine how the two perforated baffles( Inclined angle=$5^{\circ}$; perforation diameter=2cm) placed at a rectangular duct affect heat transfer and associated friction factors. The parametric effects of perforated baffles(3, 6 and 12 holes) and flow Reynolds number ranging from 28,900 to 61,000 on the heated target surface are explored. As for the investigation of heat transfer behaviours on the local Nusselt number with two baffles placed at $x/D_h=0.8$ and $x/D_h=0.8$ of the edge baffles, it is evident that the average Nusselt number increases with increasing number of holes, but the friction factor decreases with an increase in the hole number placed at baffles. The numerical results by commercial code CFX 10.0 are confirmed with the experimental data.

Three-Dimensional Numerical Study on the Vortex Flow in a Horizontal Channels with High Viscous Fluid (수평채널 내 고 점성유체의 볼텍스 유동에 관한 3차원 수치해석(1))

  • Piao, Ri-Long;Kim, Jeong-Soo;Bae, Dae-Seok
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.79-86
    • /
    • 2014
  • Mixed convective vortex flow in the three-dimensional rectangular channel filled with high viscous fluid(Pr=909) is investigated computationally under various operating conditions. The Reynolds number is varied from 0 to $5{\times}10^{-1}$, the Rayleigh number from $10^3$ to $5{\times}10^4$. The three-dimensional governing equations are discretized using the finite volume method. The effects of Reynolds number and Rayleigh number are presented and discussed. From a parametric study, it is found that vortex flow pattern of mixed convection in rectangular channels can be classified into three flow patterns basically, but the new vortex flow structures containing wave rolls are found, which are affected by Rayleigh number and Reynolds number. From this results, we can draw a flow regime map to delineate various vortex flow patterns in the high viscosity fluid mixed convective flow.

Evaluation of Efficiency of Outpatient Clinic in a General Hospital using Data Envelopment Analysis (DEA) (일 종합병원 외래간호단위의 효율성 평가 -자료포락분석법(Data Envelopment Analysis)의 적용)

  • Im, Hye-Bin;Lim, Ji-Young
    • Journal of Home Health Care Nursing
    • /
    • v.19 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • Purpose: The aim of this study is to evaluate the efficiency of the outpatient clinics in a hospital, using DEA. Methods: Data were collected using an activity-based costing system, medical information system, and annual reports of customer satisfaction management team of a general hospital in a city. The input variables were the number of doctors, the number of nurses, and the number of staffs. The output variables were the number of treatment times, the number of outpatient clinic patients, the total profits from outpatient clinic, the patient's satisfaction score, and the number of re-visit appointments. EMS Window version 3.1 was used to measure the efficiency score and benchmarking analysis. Results: The average efficiency score of 24 outpatient clinics was about 82.01%. Thirteen outpatient clinics had 100% efficiency score among them. The lowest efficiency score was 57.56%. Conclusion: According to these results, we found that, generally, outpatient clinics were operated very efficiently. However, some outpatient clinics had low efficiency and they needed specialized outcome improvement strategies. To increase the efficiency of inefficient outpatient clinics, we will recommend using results of DEA, as a benchmark point of the most efficient outpatient clinics.

  • PDF