• Title/Summary/Keyword: number of placed implants

Search Result 49, Processing Time 0.02 seconds

EFFECT OF ANCHORAGE SYSTEMS AND PALATAL COVERAGE OF DENTURE BASE ON LOAD TRANSFER WITH MAXILLARY IMPLANT-SUPPORTING OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS (상악 임플란트 overdenture에서 anchorage system과 의치상 구개피개가 하중전달에 미치는 영향)

  • Je, Hong-Ji;Jeon, Young-Chan;Jeong, Chang-Mo;Lim, Jang-Seop;Hwang, Jai-Sug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.397-411
    • /
    • 2004
  • Purpose: The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-supported overdenture. Material and methods: Maxillary implant -supported overdentures in which 4 implants were placed in the anterior region of edentulous maxilla were fabricated, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional photoelastic stress analysis. Two photoelastic overdenture models were fabricated in each anchorage system to compare with the palatal coverage extent of denture base, as a result we got eight models : Hader bar using clips(type 1), cantilevered Hader bar using clips(type 2), Hader bar using clip and ERA attachments(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4). Result: 1. In all experimental models, the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. In every experimental models with or without palatal coverage of denture base, maximum fringe orders on the distal ipsilateral implant supporting bone in an ascending order is as follows; type 3, type 1, type 4, and type 2. 3. Each implants showed compressive stresses in all experimental models with palatal coverage of denture base, but in the case of those without palatal coverage of denture base, tensile stresses were observed in the distal contralateral implant supporting bone. 4. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant supporting bone on loaded side. 5. The type of anchorage system affected in load transfer more than palatal coverage extent of the denture base. Conclusion: To the results mentioned above, in the case of patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant, and poor bone quality, selecting a resilient type attachment or minimizing the distal cantilevered bar is considered to be an appropriate method to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

The distribution of Xive implant patients and the type of implant site and survival rate in mandible (하악에 식립된 Xive implant 환자의 분포 및 식립부 유형과 생존율)

  • Jang, In-Kwon;Jung, Ui-Won;Kim, Chang-Sung;Shim, Joon-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.437-448
    • /
    • 2005
  • This study is an analysis of distribution of patients who installed Xive implant in Yonsei University Hospital and types of implant site for about 2 years recall check and cumulative survival rate. 41 implant were used in this study. It shows the conclusion below. 1. Patients at the age of 40s and 50s were 60% of all implant cases and average number of implant was 2.4(man), and 1.9(woman). All cases were operated on mandible, 3 implants on anterior region and 38 implants on posterior region. 2. The major cause of tooth loss is dental caries(48.8%), followed by periodontal disease. 3. Most distribution of bone qaulity for mandibular implant site was type II(65.8%) and bone quantity was type B(75.6%). 4. The majority of implants were those of 11, 13mm in length(95%) and regular diameter in width (64%). 5. The 41(19 persons) Xive implants that were placed in the mandibular anterior and posterior region were all survival and showed a 100% 2 year cumulative survival rate. The results provided us with basic data on patient type, implant distribution, bone condition, and survival rate. We wish that our results coupled with other research data helps assist in the further study for better implant success rates, etc.

Esthetic removable partial denture with implants and resin clasp: Case report (임플란트와 레진 클래스프를 이용한 심미 가철성 국소의치 증례)

  • Kim, Su-Min;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.58-65
    • /
    • 2015
  • For the rehabilitation of fully edentulous patients, implant-supported removable partial dentures can be considered as one of the treatment options with complete dentures or implant-supported overdentures. If removable partial dentures are used in combination with a small number of implants placed in strategically important positions, it can offer additional stability, retention and support through implants and reduce a burden of surgical procedures compared with fixed implant-supported prostheses with extensive implant placement. Moreover, the economical benefit can be expected as well. The purpose of this case report is to present a treatment in which an implant-supported removable partial denture was fabricated considering residual alveolar bone status and demands after teeth loss in a patient who had been using a distal extension removable partial denture for a long period of time. In anterior area, fixed prostheses were fabricated with implant placement and in posterior area, short implants provide only support for the removable partial denture. In addition, denture base and clasp were made of thermoplastic acrylic resin. Finally, functionally and aesthetically satisfying treatment results can be achieved.

Histomorphometric analysis of microcrack healing after the installation of mini-implants

  • Shin, Soobin;Park, Pan-Soo;Baek, Seung-Hak;Yang, Il-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.62-68
    • /
    • 2015
  • Purpose: The goal of this study was to investigate the histomorphometric characteristics of the healing process of microcracks in the cortical bone after the installation of mini-implants (MIs). Methods: Self-drilling MIs were inserted into the tibial diaphysis of twelve adult male New Zealand rabbits. Four MIs per rabbit were placed randomly. The animals were divided into four groups according to the length of the healing period: group A was sacrificed immediately, group B was sacrificed after one week, group C was sacrificed after two weeks, and group D was sacrificed after four weeks. Cortical bone thickness was measured using micro-computed tomography, and histomorphometric analyses of the cumulative length of the microcracks (CLCr) and the total number of microcracks (NCr) were performed using hematoxylin and eosin staining. Results: The microcracks were radially and concentrically aligned in the peri-MI bone. The CLCr decreased significantly one week after the surgery, mainly due to healing of the concentrically aligned microcracks. The CLCr showed another significant decrease from two weeks after the surgery to four weeks after the surgery, mainly reflecting healing of the radially aligned microcracks. A statistically significant decrease in the NCr occurred as the microcracks healed from zero weeks to two weeks. However, no significant difference in the NCr was found between groups C and D. Conclusions: In order to improve the primary stability of MIs, delayed loading and a healing period of a certain length are recommended to ensure the optimal healing of microcracks and bone remodeling.

CLINICAL INVESTIGATION ON THE FEASIBILITY OF OUTFRACTURE OSTEOTOMY SINUS GRAFT TECHNIQUE (Outfracture osteotomy sinus graft technique의 유용성에 관한 임상적 고찰)

  • Song, Seung-Il;Jeong, Hye-Rin;Kim, Hyung-Mo;Lee, Jeong-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.367-371
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the feasibility of the outfracture osteotomy sinus graft technique with the evaluation of 5-year survival rate of the implants placed in the atrophic edentulous posterior maxillary area. Materials and methods: One hundred and thirteen cases of 96 patients who visited our center from Aug 2004 to July 2009 and were diagnosed as atrophic edentulous maxillary alveolar ridge, were selected and underwent augmentation sinus surgery with outfracture osteotomy technique. Feasibility of the outfracture osteotomy technique was investigated with clinical and radiographic evaluation to assess the survival rate of the total dental implants in augmentation sinus surgery of this new kind. Total fixture number available in follow-up period was 179, in which the lost 10 patients were excluded out of 96 patients. Results: Five-year cumulative survival rate was 97.2% with 5 failures of total 179 fixtures. The average follow-up period was 29 and a half months, with the minimum and maximum follow-up periods of 4 months 21 days and 59 months 14 days, respectively. Conclusion: Traditional infracture technique is a popular method for an augmentation sinus surgery. The authors modified this classical method by outfracturing and readapting the bony window after sinus graft, with excellent treatment results evidenced by high survival rate of 97.2% (174 out of 179 fixtures), which proves the feasibility of the newly-designed outfracture osteotomy sinus graft technique.

The use of implant-assisted removable partial denture in the partially edentulous maxilla with a few unilateral remaining teeth and implant overdenture in the mandible: A case report (상악 편측 소수 잔존치에서 임플란트 융합 국소의치와 하악 임플란트 피개의치의 수복 증례)

  • Yun, Yina;Kim, Hyun-Ah;Park, Sangwon;Park, Chan;Jang, Woohyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.515-522
    • /
    • 2021
  • Successful cases of the implant-assisted removable partial denture and implant overdentures are reported in which a few implants are additionally placed to secure the maintenance, support, and stability of the denture when there are a few residual teeth. When the lateral force applied to the tooth abutment and implant surveyed crown is minimized, the horizontal and rotational movement of the denture is significantly reduced which is an effective method that can improve the address in patients who complain of reduced retention and stability of their dentures. In this case, a small number of implants were placed to fabricate an implant-assisted removable partial denture with implant surveyed crown in the maxilla and implant overdenture with Locator® attachment in the mandible to improve the retention, stability, and support of the dentures. The patient was satisfied with both functional and aesthetic aspects after the final dentures were delivered.

Immediate loading on mandibular edentulous patient with SFI Bar$^{(R)}$ overdenture

  • Kim, Ha-Young;Kim, Jin-Young-Ryan;Qadeer, Sarah;Jeong, Chang-Mo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.47-50
    • /
    • 2011
  • Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar$^{(R)}$ (Cendres et Me$\'{e}$taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

Effect of Low-Intensity Pulsed Ultrasound on Bone Healing around Titanium Implant in Tibia of Diabetes Mellitus Induced Rats (당뇨유도 백서 경골에 티타늄 임플란트 매식 시 저출력 초음파 적용이 골치유에 미치는 영향)

  • Seo, Young-Kyo;Kim, Uk-Kyu;Park, Sang-Jun;Lee, Soo-Woon;Kim, Yong-Deok;Hwang, Dae-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.3
    • /
    • pp.163-172
    • /
    • 2012
  • Purpose: Diabetes mellitus (DM) has been shown to alter the properties of the bone and impair bone healing around a titanium implant. The aim of this study is to investigate whether the low-intensity pulsed ultrasound (LIPUS), which has been known to stimulate the bone healing, improve the osseointegration of the titanium implant in tibia of DM-induced rats. Methods: 16 rats were received streptozotocin (60 mg/kg) for inducing diabetes. A total number of 32 titanium implants were placed bilaterally into both tibiae of these rats. The right tibia of each rat received LIPUS application (10 min/day) during 7 days post-operation, while the left side received no treatment. The study was carried on for six weeks and the rats were sacrificed at 1, 2, 4, and 6 weaks postoperatively (4 rats for each week) for histomorphometric and histologic analysis. Bone-implant contact and bone area were measured. Comparisons between the groups were made using statistical analysis on histomorphometric analysis. Results: The histomorphometry parameters showed that the bone-implant contact and the bone area values have decreased in the late osseointegration periods (4, 6 weeks) compared to the early osseointegration periods (1, 2 weeks) in both two groups. The bone-implant contact values of the LIPUS group were somewhat higher than those of controls at 1, 2 weeks, but the difference was not statistically significant. The bone area values of the LIPUS group were also higher than those of controls at 1, 2 weeks, but the difference was not statistically significant as well. Conclusion: Results of this study indicate that LIPUS may have positive effects on early osseointegration but could not improve the long term stability of dental implants.

EFFECT OF ANCHORAGE SYSTEMS ON LOAD TRANSFER WITH MANDIBULAR IMPLANT OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS (하악 임플란트 overdenture에서 anchorage system이 하중전달에 미치는 영향)

  • Kim Jin-Yeol;Jeon Young-Chan;Jeong Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.507-524
    • /
    • 2002
  • Load transfer of implant overdenture varies depending on anchorage systems that are the design of the superstructure and substructure and the choice of attachment. Overload by using improper anchorage system not only will cause fracture of the framework or screw but also may cause failure of osseointegration. Choosing anchorage system in making prosthesis, therefore, can be considered to be one of the most important factors that affect long-term success of implant treatment. In this study, in order to determine the effect of anchorage systems on load transfer in mandibular implant overdenture in which 4 implants were placed in the interforaminal region, patterns of stress distribution in implant supporting bone in case of unilateral vertical loading on mandibular left first molar were compared each other according to various types of anchorage system using three-dimensional photoelastic stress analysis. The five photoelastic overdenture models utilizing Hader bar without cantilever using clips(type 1), cantilevered Hader bar using clips(type 2), cantilevered Hader bar with milled surface using clips(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4), and Hader bar using clip and ERA attachments(type 5), and one cantilevered fixed-detachable prosthesis(type 6) model as control were fabricated. The following conclusions were drawn within the limitations of this study, 1. In all experimental models. the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. Maximum fringe orders on ipsilateral distal implant supporting bone in a ascending order is as follows: type 5, type 1, type 4, type 2 and type 3, and type 6. 3. Regardless of anchorage systems. more or less stresses were generated on the residual ridge under distal extension base of all overdenture models. To summarize the above mentioned results, in case of the patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant and unfavorable antero-posterior spread. selecting resilient type attachment or minimizing distal cantilever bar is considered to be appropriate methods to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

Clinical outcomes of implant supported fixed-hybrid prostheses in the fully edentulous arches (완전무치악 환자에서 고정성 임플란트 하이브리드 수복물의 임상성적)

  • Huh, Yoon-Hyuk;Yi, Yang-Jin;Kwon, Min-Jung;Kim, Young-Kyun;Cha, Min-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.183-189
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate clinical outcomes of implant supported fixed-hybrid prostheses (FHP) in the fully edentulous arches. Materials and methods: Patients in this retrospective study were restored with fixed-hybrid prostheses supported by 4 to 6 implants and functioned more than 1 year of loading. Outcome measures were marginal bone change of implant related with sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients, tilting of posterior implant by Mann- Whitney U test and cantilever length of superstructure by regression analysis, and complication rates. Significance level was set P<.05. Results: A total number of 84 implants (16 restorations) placed in 16 patients were observed for 28 months and mean marginal bone loss was $0.53{\pm}0.39mm$. There were no differences of marginal bone loss according to sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients (P>.05), and cantilever length was not significantly related with a marginal bone loss of implant next to cantilever (P>.05). Complication was shown in 11 patients and veneer fracture and dislodging of artificial teeth were most prevalent. Conclusion: Within the limitations of this study, although marginal bone loss of FHP was very little, complication rates were high. Irrespective of tilting of most posterior implants, marginal bone loss of most posterior implants next to cantilever was less than those of the other implants positioned anteriorly. Cantilever length (<17 mm) did not affect a marginal bone loss of most posterior implants.