• Title/Summary/Keyword: nuclear physics

Search Result 1,116, Processing Time 0.029 seconds

The Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography

  • Park, Cheol-Soo;Cho, Jae-Hwan;Lee, Hae-Kag;Dong, Kyung-Rae;Chung, Woon-Kwan;Seok, Jong-Min;Han, Man-Seok;Lee, Sun-Yeob;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.138-144
    • /
    • 2012
  • 3-dimensional magnetic resonance cholangiopancreatography (MRCP) images reconstructed using the maximum intensity projection technique were analyzed qualitatively in patients diagnosed with pancreatobiliary diseases to determine their diagnostic utility. Single shot fast spin echo (SSFSE), fast spin echo (FSE) and 3-dimensional reconstructive images were acquired from 20 patients diagnosed histologically with pancreatobiliary diseases using a 3.0T MR scanner. According to qualitative analysis, the fast spin echo images and 3-dimensional reconstructed images of the hepatic duct, gall bladder and common bile duct had a higher signal to noise ratio (SNR) than the single shot fast spin echo images. Fast spin echo images and 3-dimensional reconstructed images did not show any differences. The contrast to noise ratio of the hepatic duct, gallbladder and common bile duct on the fast spin echo images and 3-dimensional reconstructed images was higher than that of the single shot fast spin echo images. The fast spin echo images and 3-dimensional reconstructed images showed similar quality.

Nanostructure of Optical Materials Doped with Rare-Earths: X-Ray Absorption Spectroscopy of Dy-Doped Ge-As-S Glass (희토류 첨가 광소재의 나노구조 : Dy 첨가 Ge-As-S 유리의 X-선 흡수 스펙트럼 분석)

  • Choi, Yong-Gyu;Song, Jay-Hyok;Shin, Yong-Beom;Chernov, Vladimir A.;Heo, Jong
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.3 s.286
    • /
    • pp.177-184
    • /
    • 2006
  • Dy $L_3$-edge XANES and EXAFS spectra of chalcogenide Ge-As-S glass doped with ca. 0.2 wt% dysprosium have been investigated along with some reference Dy-containing crystals. Amplitude of the white-line peak in XANES spectrum of the glass sample turns out to be stronger than that of other reference crystals, i.e., $DY_2S_3,\;Dy_2O_3\;and\;DyBr_3$. It has been verified from the Dy $L_3$-edge EXAFS spectra that a central Dy atom is surrounded by $6.7{\pm}0.5$ sulfur atoms in its first coordination shell in the Ge-As-S glass, which is relatively smaller than 7.5 of the $Dy_2S_3$ crystal. Averaged Dy-S inter-atomic-distance of the glass ($2.78{\pm}0.01{\AA}$) also turns out to be somewhat shorter than that of the $Dy_2S_3$ crystal ($2.82{\pm}0.01{\AA}$). Such nanostructural changes occurring at Dy atoms imply there being stronger covalency of Dy-S chemical bonds in the Ge-As-S glass than in the crystal counterpart. The enhanced covalency in the nanostructural environment of $Dy^{3+}$ ions inside the glass would then be responsible for optical characteristics of the $4f{\leftrightarrow}4f$ transitions of the dopants, i.e., increase of oscillator strengths and spontaneous radiative transition probabilities.

On the Radial Velocity Offset for [OIII] Emission Line of LINER Galaxies

  • Bae, Hyun-Jin;Woo, Jong-Hak;Yagi, Masafumi;Yoon, Suk-Jin;Yoshida, Michitoshi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.33.2-33.2
    • /
    • 2012
  • Low-ionization nuclear emission-line region (LINER) galaxies constitute a major fraction of low-luminosity AGN population in the local Universe. In contrast to Seyfert galaxies, it is theoretically expected that LINERs would not have an outflow due to their low Eddington ratio. Using Keck/LRIS spectroscopy on a nearby LINER galaxy SDSS J091628.05+420818.7, we find a significant radial velocity offset for [OIII]${\lambda}$5007 emission line as - 50 km $s^{-1}$ blueshifted compared to systemic velocity of the galaxy, while other emission lines exhibit no or little offset. The observed [OIII] velocity offset possibly indicates an outflow of gas in the LINER galaxy, and it is probable that we only detected the [OIII] velocity offset because [OIII] ionization region is closer to the accretion disk, hence, more affected by an outflow. We further investigate the [OIII] velocity offset of -4000 SDSS AGN-host galaxies to compare the strength of AGN outflow. We find that a number of both LINER and Seyfert galaxies show [OIII] velocity offset, but the fraction of LINER galaxies with velocity offset is smaller than that of Seyfert galaxies. The preliminary results imply the presence of gas outflow in LINER galaxies, although outflow strength is probably weaker compared to Seyfert galaxies.

  • PDF

The KSTAR Vacuum Pumping and Fueling System Upgrade

  • Lim, J.Y.;Chung, K.H.;Cho, S.Y.;Lee, S.K.;Shin, Y.H.;Hong, S.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.39-39
    • /
    • 1999
  • The KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak is a nuclear fusion experimental device for a long pulse/steady-state plasma operation, adopting fully superconducting magnets. In accordance with completion of the basic design of the torus vacuum vessel and the enclosing cryostat, the vacuum pumping and gas fueling basic design has been developed to fulfil the physics requirements. The ultra-high vacuum pumping and sophisticated gas fueling system of the machine is essential to achieve such roles for optimized plasma performance and operation. Recently the vacuum exhaust system using dedicated pumping ports for the vacuum vessel and cryostat has been modified to meet more reliable and successful performance of the KSTAR[Fig. 1].In order to achieve the required base pressure of 5 x 10-9 torr, the total impurity load to the vessel internal is limited to ~5 x 10-5 torr-1/x, while the cryostat base pressure is kept as ~5 x 105 torr to mitigate the thermal load applied to the superconducting magnets. Each KSTAR fueling system will be separately capable of fueling gas at a rate of 50 torr-1/x, consistent with the given pumping throughput. In order to initiate a plasma discharge in KSTAR, the vacuum vessel is filled to a gas pressure of few 10-6 to few 10-4 torr, and additional gas injection is required to maintain and increase the plasma density during the course of the discharge period.

  • PDF

The black hole mass-stellar velocity relation of the present-day active galaxies

  • Woo, Jong-Hak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.79-79
    • /
    • 2010
  • To investigate whether the present-day active galaxies follow the same black hole mass vs. stellar velocity dispersion (MBH-$\sigma*$) relation as quiescent galaxies, we measured the velocity dispersions of a sample of local Seyfert 1 galaxies, for which black hole masses were measured via reverberation mapping. We measured stellar velocity dispersions from high S/N optical spectra centered on the Ca II triplet region (${\sim}8500^{\circ}A$), obtained at the Keck, Palomar, and Lick Observatories. For two objects, in which the Ca II triplet region was contaminated by nuclear emission, we used high-quality H-band spectra obtained with the OH-Suppressing Infrared Imaging Spectrograph and laser-guide star adaptive optics at the Keck-II Telescope. Combining our new measurements with data from the literature, we assemble a sample of 24 active galaxies with stellar velocity dispersions and reverberation MBH in the range of black hole mass 106< MBH /$M{\odot}$ < 109,toobtainthefirstreverberationmappingconstraintsontheslopeandintrinsicscatteroftheMBH- $\sigma*$ relation of active galaxies. Assuming a constant virial coefficient f for the reverberation MBH, we find a slope ${\beta}=3.55{\pm}0.60$ and the intrinsic scatter ${\sigma}int=0.43{\pm}0.08$ dex in the relation log (MBH/M${\odot}$)=$\alpha+\beta$ log(${\sigma}*$/200 km s-1), which are consistent with those found for quiescent galaxies. We derive an updated value of the virial coefficient f by finding the value which places the reverberation masses in best agreement with the MBH - $\sigma*$ relation of quiescent galaxies; using the quiescent MBH - $\sigma*$ relation determined by Gultekin et al. we find log f=0.72+0.09 (or $0.71{\pm}0.10$) with an intrinsic scatter of $0.44{\pm}0.07$ (or 0.46+0.07) dex. No correlations between f and parameters connected to the physics of accretion (such as the Eddington ratio or line-shape measurements) are found. The uncertainty of the virial coefficient remains one of the main sources of the uncertainty in black hole mass determination using reverberation mapping, and therefore also in single-epoch spectroscopic estimates of black hole masses in active galaxies.

  • PDF

Dynamics of a Globular Protein and Its Hydration Water Studied by Neutron Scattering and MD Simulations

  • Kim, Chan-Soo;Chu, Xiang-Qiang;Lagi, Marco;Chen, Sow-Hsin;Lee, Kwang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.21-21
    • /
    • 2011
  • A series of Quasi-Elastic Neutron Scattering (QENS) experiments helps us to understand the single-particle (hydrogen atom) dynamics of a globular protein and its hydration water and strong coupling between them. We also performed Molecular Dynamics (MD) simulations on a realistic model of the hydrated hen-egg Lysozyme powder having two proteins in the periodic box. We found the existence of a Fragile-to-Strong dynamic Crossover (FSC) phenomenon in hydration water around a protein occurring at TL=$225{\pm}5K$ by analyzing Intermediate Scattering Function (ISF). On lowering of the temperature toward FSC, the structure of hydration water makes a transition from predominantly the High Density Liquid (HDL) form, a more fluid state, to predominantly the Low Density Liquid (LDL) form, a less fluid state, derived from the existence of a liquid?liquid critical point at an elevated pressure. We showed experimentally and confirmed theoretically that this sudden switch in the mobility of the hydration water around a protein triggers the dynamic transition (so-called glass transition) of the protein, at a temperature TD=220 K. Mean Square Displacement (MSD) is the important factor to show that the FSC is the key to the strong coupling between a protein and its hydration water by suggesting TL${\fallingdotseq}$TD. MD simulations with TIP4P force field for water were performed to understand hydration level dependency of the FSC temperature. We added water molecules to increase hydration level of the protein hydration water, from 0.30, 0.45, 0.60 and 1.00 (1.00 is the bulk water). These confirm the existence of the FSC and the hydration level dependence of the FSC temperature: FSC temperature is decreased upon increasing hydration level. We compared the hydration water around Lysozyme, B-DNA and RNA. Similarity among those suggests that the FSC and this coupling be universal for globular proteins, biopolymers.

  • PDF

On the Nature of LINERs: A Clue from Keck/LRIS Observations

  • Bae, Hyun-Jin;Yagi, Masafumi;Woo, Jong-Hak;Yoshida, Michitoshi;Yoon, Suk-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.61.2-61.2
    • /
    • 2011
  • Low-ionization nuclear emission-line regions (LINERs) have been generally regarded to be powered by active galactic nuclei (AGNs), yet still a number of alternative explanations on the origin of LINER emission are suggested; for example, planetary nebulae nuclei of massive stars, supernovae shocks from death of massive stars, and old stellar populations. Interestingly, a majority of recent star formation early-type galaxies (ETGs) in local universe presents such LINER emission lines. Given that situation, revealing the true nature of LINERs is a crucial step to constrain the evolution path to quiescent ETGs. To resolve the issue, we use Keck/LRIS to obtain spatially resolved spectra on a carefully selected ETG. The ETG SDSS J091628.05+420818.7 at redshift z ~ 0.024 shows modest LINER emission line features without any detection of 21 cm radio continuum nor X-ray emission. We perform a stellar continuum subtraction and measure emission line strengths and their uncertainties for each spectrum from five apertures along the slit with size of 1 arcsecond (~0.5 kpc). We find that extended spatial distributions of four emission lines $H{\alpha}$, $H{\beta}$, [OIII]${\lambda}5007$, and [NII]${\lambda}6583$, and they can be explained by central emission blurring effect. We conclude that the emissions seem to be centrally concentrated, indicating the AGN-nature of LINERs.

  • PDF

Label-free Noninvasive Characterization of Osteoclast Differentiation Using Raman Spectroscopy Coupled with Multivariate Analysis

  • Jung, Gyeong Bok;Kang, In Soon;Lee, Young Ju;Kim, Dohyun;Park, Hun-Kuk;Lee, Gi-Ja;Kim, Chaekyun
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.412-420
    • /
    • 2017
  • Multinucleated bone resorptive osteoclasts differentiate from bone marrow-derived monocyte/macrophage precursor cells. During osteoclast differentiation, mononuclear pre-osteoclasts change their morphology and biochemical characteristics. In this study, Raman spectroscopy with multivariate techniques such as Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA) were used to extract biochemical information related to various cellular events during osteoclastogenesis. This technique allowed for label-free and noninvasive monitoring of differentiating cells, and clearly discriminated four different time points during osteoclast differentiation. The Raman band intensity showed significant time-dependent changes that increased up to day 4. The results of Raman spectroscopy agreed with results from atomic force microscopy (AFM) and tartrate-resistant acid phosphatase (TRAP) staining, a conventional biological assay. Under AFM, normal spindle-like mononuclear pre-osteoclasts became round and smaller at day 2 after treatment with a receptor activator of nuclear $factor-{\kappa}B$ ligand and they formed multinucleated giant cells at day 4. Thus, Raman spectroscopy, in combination with PCA-LDA, may be useful for noninvasive label-free quality assessment of cell status during osteoclast differentiation, enabling more efficient optimization of the bioprocesses.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Study on the Small Fields Dosimetry for High Energy Photon-based Radiation Therapy (고에너지 광자선을 이용한 방사선 치료 시 소조사면에서의 흡수선량평가에 관한 연구)

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.290-297
    • /
    • 2009
  • In case of radiation treatment using small field high-energy photon beams, an accurate dosimetry is a challenging task because of dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons, and non-uniformity between the detector and the phantom materials. In this study, the absorbed dose in the phantom was measured by using an ion chamber and a diode detector widely used in clinics. $GAFCHROMIC^{(R)}$ EBT films composed of water equivalent materials was also evaluated as a small field detector and compared with ionchamber and diode detectors. The output factors at 10 cm depth of a solid phantom located 100 cm from the 6 MV linear accelerator (Varian, 6 EX) source were measured for 6 field sizes ($5{\times}5\;cm^2$, $2{\times}2\;cm^2$, $1.5{\times}1.5\;cm^2$, $1{\times}1\;cm^2$, $0.7{\times}0.7\;cm^2$ and $0.5{\times}0.5\;cm^2$). As a result, from $5{\times}5\;cm^2$ to $1.5{\times}1.5\;cm^2$ field sizes, absorbed doses from three detectors were accurately identified within 1%. Wheres, the ion chamber underestimated dose compared to other detectors in the field sizes less than $1{\times}1\;cm^2$. In order to correct the observed underestimation, a convolution method was employed to eliminate the volume averaging effect of an ion chamber. Finally, in $1{\times}1\;cm^2$ field the absorbed dose with a diode detector was about 3% higher than that with the EBT film while the dose with the ion chamber after volume correction was 1% lower. For $0.5{\times}0.5\;cm^2$ field, the dose with the diode detector was 1% larger than that with the EBT film while dose with volume corrected ionization chamber was 7% lower. In conclusion, the possibility of $GAFCHROMIC^{(R)}$ EBT film as an small field dosimeter was tested and further investigation will be proceed using Monte Calro simulation.

  • PDF