• 제목/요약/키워드: nuclear magnetic resonance imaging

검색결과 124건 처리시간 0.026초

동물에서 자기 공명 영상 진단의 물리적 원리 (Physical Principles of Magnetic Resonance Imaging in Animal)

  • 김종규
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.75-79
    • /
    • 1999
  • Magnetic resonance imaging (MRI) is an imaging technique used to produce high quality images of the inside of the animal body. MRI is based on the principles of nuclear magnetic resonance (NMR) and started out as a tomographic imaging technique, that is it produced an image of the NMR signal in a thin slice through the animal body. The animal body is primarily fat and water, Fat and water have many hydrogen atoms. Hydrogen nuclei have an NMR signal. For these reasons magnetic resonance imaging primarily images the NMR signal from the hydrogen nuclei. Hydrogen protons, within the body align with the magnetic field. By applying short radio frequency (RF) pulses to a specific anatomical slice, the protons in the slice absorb energy at this resonant frequency causing them to spin perpendicular to the magnetic field. As the protons relax back into alignment with the magnetic field, a signal is received by an RF coil that acts as an antennae. This signal is processed by a computer to produce diagnostic images of the anatomical area of interest.

  • PDF

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

Hyperpolarization: Sensitivity Boost in Magnetic Resonance Spectroscopy and Imaging

  • Ko, Hyeji;Gong, Gyeonghyeon;Jeong, Gijin;Choi, Ikjang;Seo, Hyeonglim;Lee, Youngbok
    • 한국자기공명학회논문지
    • /
    • 제19권3호
    • /
    • pp.124-131
    • /
    • 2015
  • Hyperpolarization methods are the most emerging techniques in the field of magnetic resonance (MR) researches since they make a contribution to overcoming sensitivity limitation of MR spectroscopy and imaging, leading to new fields of researches, real-time in vivo metabolic/molecular imaging and MR analysis of chemical/biological reactions in non-equilibrium conditions. Make use of enormous signal enrichments, it becomes feasible to investigate various chemical and biochemical systems with low ${\gamma}$ nuclei in real-time. This review deals with the theoretical principals of common hyperpolarization methods and their experimental features. In addition, more detailed theories, mechanisms, and applications of dissolution dynamic nuclear polarization (D-DNP) are discussed.

MR조영제와 분자영상 (MR Contrast Agents and Molecular Imaging)

  • 문우경
    • 대한핵의학회지
    • /
    • 제38권2호
    • /
    • pp.205-208
    • /
    • 2004
  • The two major classes of magnetic resonance (MR) contrast agents are paramagnetic contrast agents, usually based on chelates of gadolinium generating T1 positive signal enhancement, and super-paramagnetic contrast agents that use mono- or polycrystalline iron oxide to generate strong T2 negative contrast in MR images. These paramagnetic or super-paramagnetic complexes are used to develop new contrast agents that can target the specific molecular marker of the cells or tan be activated to report on the physiological status or metabolic activity of biological systems. In molecular imaging science, MR imaging has emerged as a leading technique because it provides high-resolution three-dimension maps of the living subject. The future of molecular MR imaging is promising as advancements in hardware, contrast agents, and image acquisition methods coalesce to bring high resolution in vivo imaging to the biochemical sciences and to patient care.

갈륨 신티그라피와 자기공명영상으로 진단한 근육 유육종증 (A Case of Muscular Sarcoidosis diagnosed by Gallium-67 Scintigraphy and Magnetic Resonance Imaging)

  • 손형선;김의녕
    • 대한핵의학회지
    • /
    • 제33권6호
    • /
    • pp.543-547
    • /
    • 1999
  • Gallium-67 scintigraphy is helpful in the assessment of active extrapulmonary sarcoidosis. Muscular involvement of sarcoidosis is often asymptomatic or nonspecific, and laboratory examinations do not provide convincing evidence of muscular involvement We report a case of muscular sarcoidosis, which was detected by gallium-67 scintigraphy. In a patient who was suffering from fever and arthralgia of knee joint, gallium-67 scintigraphy showed mediastinal and hilar involvement of sarcoidosis with unexpected extensive muscular uptake. Magenetic resonance imaging revealed the detailed depiction of intramuscular infiltration of sarcoid granuloma. Gallium-67 scintigraphy is useful in detecting inflammatory muscular involvement of sarcoidosis as well as other multiorgan involvement.

  • PDF

In Vivo Reporter Gene Imaging: Recent Progress of PET and Optical Imaging Approaches

  • Min, Jung-Joon
    • Bioinformatics and Biosystems
    • /
    • 제1권1호
    • /
    • pp.17-27
    • /
    • 2006
  • Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene delivery and/or expression. This article reviews the use of radionuclide, magnetic resonance, and optical imaging technologies as they have been used in imaging gene delivery and gene expression for molecular imaging applications. The studies published to date demonstrate that noninvasive imaging tools will help to accelerate pre-clinical model validation as well as allow for clinical monitoring of human diseases.

  • PDF

Atypical β-Catenin Activated Child Hepatocellular Tumor

  • Turan, Aynur;Unlu, Havva Akmaz;Karakus, Esra;Erdem, Arzu Yazal;Yakut, Zeynep Ilerisoy
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제18권2호
    • /
    • pp.144-148
    • /
    • 2015
  • Hepatocellular adenomas are a benign, focal, hepatic neoplasm that have been divided into four subtypes according to the genetic and pathological features. The ${\beta}$-catenin activated subtype accounts for 10-15% of all hepatocellular adenomas and specific magnetic resonance imaging features have been defined for different hepatocellular adenomas subtypes. The current study aimed to report the magnetic resonance imaging features of a well differentiated hepatocellular carcinoma that developed on the basis of ${\beta}$-catenin activated hepatocellular adenomas in a child. In this case, atypical diffuse steatosis was determined in the lesion. In the literature, diffuse steatosis, which is defined as a feature of the hepatocyte nuclear factor-$1{\alpha}$-inactivated hepatocellular adenomas subtype, has not been previously reported in any ${\beta}$-catenin activated hepatocellular adenomas case. Interlacing magnetic resonance imaging findings between subtypes show that there are still many mysteries about this topic and larger studies are warranted.

Recent Update of Advanced Imaging for Diagnosis of Cardiac Sarcoidosis: Based on the Findings of Cardiac Magnetic Resonance Imaging and Positron Emission Tomography

  • Chang, Suyon;Lee, Won Woo;Chun, Eun Ju
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권2호
    • /
    • pp.100-113
    • /
    • 2019
  • Sarcoidosis is a multisystem disease characterized by noncaseating granulomas. Cardiac involvement is known to have poor prognosis because it can manifest as a serious condition such as the conduction abnormality, heart failure, ventricular arrhythmia, or sudden cardiac death. Although early diagnosis and early treatment is critical to improve patient prognosis, the diagnosis of CS is challenging in most cases. Diagnosis usually relies on endomyocardial biopsy (EMB), but its diagnostic yield is low due to the incidence of patchy myocardial involvement. Guidelines for the diagnosis of CS recommend a combination of clinical, electrocardiographic, and imaging findings from various modalities, if EMB cannot confirm the diagnosis. Especially, the role of advanced imaging such as cardiac magnetic resonance (CMR) imaging and positron emission tomography (PET), has shown to be important not only for the diagnosis, but also for monitoring treatment response and prognostication. CMR can evaluate cardiac function and fibrotic scar with good specificity. Late gadolinium enhancement (LGE) in CMR shows a distinctive enhancement pattern for each disease, which may be useful for differential diagnosis of CS from other similar diseases. Effectively, T1 or T2 mapping techniques can be also used for early recognition of CS. In the meantime, PET can detect and quantify metabolic activity and can be used to monitor treatment response. Recently, the use of a hybrid CMR-PET has introduced to allow identify patients with active CS with excellent co-localization and better diagnostic accuracy than CMR or PET alone. However, CS may show various findings with a wide spectrum, therefore, radiologists should consider the possible differential diagnosis of CS including myocarditis, dilated cardiomyopathy (DCM), hypertrophic cardiomyopathy, amyloidosis, and arrhythmogenic right ventricular cardiomyopathy. Radiologists should recognize the differences in various diseases that show the characteristics of mimicking CS, and try to get an accurate diagnosis of CS.

MRI(Magnetic Resonance Imaging)의 원리와 응용

  • 오창현
    • 한국자기학회지
    • /
    • 제6권4호
    • /
    • pp.272-276
    • /
    • 1996
  • 1948년 Harvard 대학의 Purcell교수와 Stanford 대학의 Bloch교수가 핵자기 공명(Nuclear Magnetic Resonance : NMR) 현상을 발견한 이래로 NMR은 물질의 분자단위에서 화학적, 물리학적 성질을 밝혀내는 탁월한 방법으로 널리 이용되어 왔다. NMR 현상을 이용한 영상촬영법(Magnetic Resonance Imaging, MRI)은 1970년대초 Lauterber와 Damadian 교수가 처음 영상을 얻을 수 있다는 가능성을 제시한 이후 급속한 발전을 하여 1980년대 초에는 Moore와 Holland에 의해 의학분야에 응용 가능할 정도의 영상이 얻어졌다. 1980년대 중반부터 상용화 되었으며 최근 그 기법도 NMR현상과 연관된 파라미터인 $T_{1}$, $T_{2}$는 물론 혈류의 속도, 자화율, 확산(Diffusion), Perfusion의 영상기법을 비롯해 혈관조영술(MR Angiography), 뇌기능영상(Functional Imaging)등 과거에는 상상도 할 수 없었던 다양한 영상기법 개발되었다. 여기서는 먼저 MRI의 원리를 설명한 후 MRI의 여러 촬영기법들과 그 응용에 관해 설명하겠다.

  • PDF

Cetyl Trimethyl Ammonium Bromide-coated Nickel Ferrite Nanoparticles for Magnetic Hyperthermia and T2 Contrast Agents in Magnetic Resonance Imaging

  • Lee, Da-Aemm;Bae, Hongsubm;Rhee, Ilsum
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1334-1339
    • /
    • 2018
  • Spherical nickel ferrite nanoparticles were synthesized using the thermal decomposition method and coated with cetyl trimethyl ammonium bromide (CTAB) after the synthesis. Transmission electron microscopy images showed that the average diameter of the particles was 9.40 nm. The status of the CTAB-coating on the surface of the particles was checked using Fourier-transform infrared spectroscopy. Their hysteresis curve showed that the particles exhibited a superparamagnetic behavior. The $T_1$ and the $T_2$ relaxations of the nuclear spins were observed in aqueous solutions of the particles with different particles concentrations by using a magnetic resonance imaging (MRI) scanner, which showed that the $T_1$ and the $T_2$ relaxivities of the particles in water were $0.57mM^{-1}{\cdot}s^{-1}$ and $10.42mM^{-1}{\cdot}s^{-1}$, respectively. In addition, using an induction heating system, we evaluated their potentials for magnetic hyperthermia applications. The aqueous solution of the particles with a moderate concentration (smaller than 6.5 mg/mL) showed a saturation temperature larger than the hyperthermia target temperature of $42^{\circ}C$. These findings show that the CTAB-coated nickel ferrite particles are suitable for applications as $T_2$ contrast agents in MRI and heat generators in magnetic hyperthermia.