• Title/Summary/Keyword: normalized k

Search Result 2,395, Processing Time 0.037 seconds

Composition Ratio Analysis of Transesterification Products of Olive Oil by Using Thin Layer Chromatography and Their Applicability to Cosmetics (올리브 오일의 에스터 교환반응 생성물의 TLC를 이용한 조성비 분석 및 화장품에의 응용가능성 평가)

  • Park, So Hyun;Shin, Hyuk Soo;Kim, A Rang;Jeong, Hyo Jin;Xuan, Song Hua;Hong, In Kee;Lee, Dae Bong;Park, Soo Nam
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.342-349
    • /
    • 2018
  • In this study, the physicochemical properties, emulsifying capacity, moisture content and cytotoxicity of the composite material produced by transesterification reactions of the olive oil (olive oil esters) were investigated for cosmetic applications. Olive oil esters with short (S) and long (L) reaction times were studied. From the TLC-image analysis, composition ratios of the olive oil esters S were found to be 5.2, 24.1, 46.4, and 21.9% for mono-, di-, tri-glyceride, and fatty acid ethyl ester, respectively. Those of the olive oil esters L were 4.1, 24.7, 40.6, and 28.8% for mono-, di-, tri-glyceride, and fatty acid ethyl ester, respectively. The iodine value, acid value, saponification value, unsaponified matter, refractive index, and specific gravity were determined and purity tests were also carried out and normalized to establish standards and testing methods for using olive oil esters in cosmetics. To evaluate their emulsifying capacities, the O/W emulsion was prepared without surfactants and the formation of the emulsified particles were confirmed. After 5 days of applying the olive oil esters to human skin, the skin moisture retention was improved by 13.1% from the initial state. For the evaluation of toxicity on human skin cells, the olive oil esters showed 90% or more of the cell viability at $0.2-200{\mu}g/mL$. These results suggested that olive oil esters can be applied as natural/non-toxic ingredients to cosmetics industries.

An Assessment of the Accuracy of 3 Dimensional Acquisition in F-18 fluorodeoxyglucose Brain PET Imaging (3차원 데이터획득 뇌 FDG-PET의 정확도 평가)

  • Lee, Jeong-Rim;Choi, Yong;Kim, Sang-Eun;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.327-336
    • /
    • 1999
  • Purpose: To assess the quantitative accuracy and the clinical utility of 3D volumetric PET imaging with FDG in brain studies, 24 patients with various neurological disorders were studied. Materials and Methods: Each patient was injected with 370 MBq of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose. After a 30 min uptake period, the patients were imaged for 30 min in 2 dimensional acquisition (2D) and subsequently for 10 min in 3 dimensional acquisition imaging (3D) using a GE $Advance^{TM}$ PET system, The scatter corrected 3D (3D SC) and non scatter-corrected 3D images were compared with 2D images by applying ROIs on gray and white matter, lesion and contralateral normal areas. Measured and calculated attenuation correction methods for emission images were compared to get the maximum advantage of high sensitivity of 3D acquisition. Results: When normalized to the contrast of 2D images, the contrasts of gray to white matter were $0.75{\pm}0.13$ (3D) and $0.95{\pm}0.12$ (3D SC). The contrasts of normal area to lesion were $0.83{\pm}0.05$ (3D) and $0.96{\pm}0.05$ (3D SC). Three nuclear medicine physicians judged 3D SC images to be superior to the 2D with regards to resolution and noise. Regional counts of calculated attenuation correction was not significantly different to that of measured attenuation correction. Conclusion: 3D PET images with the scatter correction in FDG brain studies provide quantitatively and qualitatively similar images to 2D and can be utilized in a routine clinical setting to reduce scanning time and patient motion artifacts.

  • PDF

Long Term Results of Rastelli Operation with a Mechanical Valve (기계 판막을 이용한 라스텔리 수술의 장기 성적)

  • Choi, Se-Hoon;Kim, Kwan-Chang;Kwak, Jae-Gun;Kim, Chang-Young;Lee, Jeong-Ryul;Kim, Yong-Jin;Rho, Joon-Ryang;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.900-905
    • /
    • 2006
  • Background: Homografts and bioprostheses are most commonly used for Rastelli operation in congenital heart disease, but the limited durability is responsible for multiple reoperations associated with increased morbidity This study evaluated long-term results after Rastelli operation with a mechanical valved conduit. Material and Method: A total of 20 patients underwent Rastelli operation with mechanical valved conduit from January 1990 to July 1992. Operative mortality was 1 of 20 patients, and a retrospective review of 19 patients(10 males, 9 females) was done. Initial diagnosis was congenitally corrected transposition of great arteries(cc-TGA, n=4), complete TGA (n=2), ventricular septal defect with pulmonary atresia(VSD with PA, n=9), truncus arteriosus(n=2), double outlet right ventricle with pulmonary stenosis(DORV with PS, n=2). The mean age at Rastelli operation was $4.6{\pm}3.4$ years, and mean follow-up period was $12.8{\pm}2.7$ years. Patients underwent Rastelli opearation using 16 CarboMedics mechanical valve, and 3 Bjork-Shiley mechanical valve($17{\pm}2$ mm). Result: There were 15 reoperations for failed mechanical valved conduit. The freedom from reoperation at 5 and 10 years was 53% and 37%. Most patients were received oral anticoagulation with warfarin, and maintained the international normalized ratio(INR) of 1.5 to 2.0. There was no anticoagulation or thromboembolism related complication. There was a significant difference in the causes of a conduit failure between early(within 3 years) and late(after 3 years) failure groups. The six patients reported early prosthetic valve failure, mainly due to valvular dysfunction by thrombosis or pannus formation. The other nine patients reported late prosthetic valve failure, mainly due to dacron conduit stenosis at anastomosis sites, whereas their valvar motion was normal except 1 patient. Conclusion: To avoid early prosthetic valve failure, strict anticoagulation therapy would be helpful. About the late development of obstructive intimal fibrocalcific peels within the Dacron conduit, an improvement of conduit material is necessary to reduce late prosthetic valve failure. In selected patients, the long term results were satisfactory.

Effect of Crude Saponins from Soybean Cake on Body Weight and Glucose Tolerance in High-Fat Diet Induced Obese Mice (대두박 사포닌 보충이 식이성 유도 비만마우스의 체중과 내당능에 미치는 영향)

  • Kim, Sung-Mi;Seo, Kwon-Il;Park, Kyung-Wuk;Jeong, Yong-Kee;Cho, Young-Su;Kim, Myung-Joo;Kim, Eun-Jung;Lee, Mi-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.1
    • /
    • pp.39-46
    • /
    • 2009
  • This study investigated the beneficial effects of crude saponins from soybean cake on body weight and glucose tolerance in high-fat (37% calories from fat) diet fed C57BL/6 mice. The mice were supplemented with three doses of saponins (0.5%, 1.0%, and 1.5%, wt/wt) and 1.0% Garcinia cambogia (wt/wt), positive control for 9 weeks. The body weight, visceral fat weight and epididymal adipocyte area were significantly reduced in the saponin supplemented groups in a dose dependent manner compared to the high-fat group. Saponins did not significantly affect food intake; however, cambogia significantly lowered food intake compared to the high-fat fed control group. The crude saponins from soybean cake supplement significantly lowered plasma leptin, triglyceride and total cholesterol levels, whereas they significantly elevated the fecal excretion of triglyceide in a dose dependent manner compared to the high-fat group. Cambogia did not affect the fecal excretion of lipid in the diet-induced obese mice. Supplementation of 1.5% saponin reduced the hepatic triglyceride content compared to the high-fat group. High-fat induced glucose intolerance with the elevation of blood glucose levels compared to the normal group; however, the saponins supplement significantly improved postprandial glucose levels. After 9 weeks of being fed a high-fat diet, the mice presented with significantly increased activities of hepatic fatty acid synthase and fatty acid ${\beta}$-oxidation; however, saponins and cambogia normalized these activities. These results indicate that saponins from soybean cake exhibit a potential anti-obesity effect and may prevent glucose intolerance by reducing body weight and plasma lipids, increasing fecal lipid excretion and regulating hepatic lipid metabolism in high-fat fed mice.

Feasibility Study of the Radiophotoluminescent Glass Dosimeter for High-energy Electron Beams (유리선량계를 이용한 고에너지 전자선 측정 이용 가능성에 관한 연구)

  • Son, Ki-Hong;Jung, Hai-Jo;Shin, Sang-Hun;Lee, Hyun-Ho;Lee, Sung-Hyun;Kim, Mi-Sook;Ji, Young-Hoon;Kim, Kum-Bae
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.52-58
    • /
    • 2011
  • Our goal is to assess the suitability of a glass dosimeter on detection of high-energy electron beams for clinical use, especially for radiation therapy. We examined the dosimetric characteristics of glass dosimeters including dose linearity, reproducibility, angular dependence, dose rate dependence, and energy dependence of 5 different electron energy qualities. The GD was irradiated with high-energy electron beams from the medical linear accelerator andgamma rays from a cobalt-60 teletherapy unit. All irradiations were performed in a water phantom. The result of the dose linearity for high-energy electron beams showed well fitted regression line with the coefficient of determination; $R^2$ of 0.999 between 6 and 20 MeV. The reproducibility of GDs exposed to the nominal electron energies 6, 9, 12, 16, and 20 MeV was ${\pm}1.2%$. In terms of the angular dependence to electron beams,GD response differences to the electron beam were within 1.5% for angles ranging from $0^{\circ}$ to $90^{\circ}$ and GD's maximum response differencewas 14% lower at 180o. In the dose rate dependence, measured dose values were normalized to the value obtained from 500 MU/min. The uncertainties of dose rate were measured within ${\pm}1.5%$ except for the value from 100 MU/min. In the evaluation of the energy dependence of the GD at nominal electron energies between 6 and 20 MeV, we obtained lower responses between 1.1% and 4.5% based on cobalt-60 beam. Our results show that GDs have a considerable potentiality for measuring doses delivered by high-energy electron beams.

Development and Preliminary Test of a Prototype Program to Recommend Nitrogen Topdressing Rate Using Color Digital Camera Image Analysis at Panicle Initiation Stage of Rice (디지털 카메라 칼라영상 분석을 이용한 벼 질소 수비량 추천 원시 프로그램의 개발과 예비 적용성 검토)

  • Chi, Jeong-Hyun;Lee, Jae-Hong;Choi, Byoung-Rourl;Han, Sang-Wook;Kim, Soon-Jae;Park, Kyeong-Yeol;Lee, Kyu-Jong;Lee, Byun-Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.4
    • /
    • pp.312-318
    • /
    • 2010
  • This study was carried out to develop and test a prototype program that recommends the nitrogen topdressing rate using the color digital camera image taken from rice field at panicle initiation stage (PIS). This program comprises four models to estimate shoot N content (PNup) by color digital image analysis, shoot N accumulation from PIS to maturity (PHNup), yield, and protein content of rice. The models were formulated using data set from N rate experiments in 2008. PNup was found to be estimated by non-linear regression model using canopy cover and normalized green values calculated from color digital image analysis as predictor variables. PHNup could be predicted by quadratic regression model from PNup and N fertilization rate at panicle initiation stage with $R^2$ of 0.923. Yield and protein content of rice could also be predicted by quadratic regression models using PNup and PHNup as predictor variables with $R^2$ of 0.859 and 0.804, respectively. The performance of the program integrating the above models to recommend N topdressing rate at PIS was field-tested in 2009. N topdressing rate prescribed for the target protein content of 6.0% by the program were lower by about 30% compared to the fixed rate of 30% that is recommended conventionally as the split application rate of N fertilizer at PIS, while rice yield in the plots top-dressed with the prescribed N rate were not different from those of the plots top-dressed with the fixed N rates of 30% and showed a little lower or similar protein content of rice as well. And coefficients of variation in rice yield and quality parameters were reduced substantially by the prescribed N topdressing. These results indicate that the N rate recommendation using the analysis of color digital camera image is promising to be applied for precise management of N fertilization. However, for the universal and practical application the component models of the program are needed to be improved so as to be applicable to the diverse edaphic and climatic condition.

The Discriminating Nature of Dopamine Transporter Image in Parkinsonism: The Competency of Dopaminergic Transporter Imaging in Differential Diagnosis of Parkinsonism: $^{123}I-FP-CIT$ SPECT Study (도파민운반체 영상의 파킨슨증 감별진단 성능: $^{123}I-FP-CIT$ SPECT 연구)

  • Kim, Bom-Sahn;Jang, Sung-June;Eo, Jae-Seon;Park, Eun-Kyung;Kim, Yu-Kyeong;Kim, Jong-Min;Lee, Won-Woo;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.272-279
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the discriminating nature of $^{123}I-FP-CIT$ SPECT in patients with parkinsonism. Methods: $^{123}I-FP-CIT$ SPECT images acquired from the 18 normal controls; NC ($60.4{\pm}10.0$ yr) and 237 patients with parkinsonism ($65.9{\pm}9.2$ yr) were analyzed. From spatialIy normalized images, regional counts of the caudate, putamen, and occipital lobe were obtained using region of interest method. Binding potential (BP) was calculated with the ratio of specific to nonspecific binding activity at equilibrium. Additionally, the BP ratio of putamen to caudate (PCR) and asymmetric Index (ASI) were measured. Results: BPs of NC $3.37{\pm}0.57,\; 3.10{\pm}0.41,\; 3.23{\pm}0.48$ for caudate, putamen, whole striatum, respectively) had no significant difference with those of essential tremor; ET ($3.31{\pm}0.64,\; 3.06{\pm}0.61,\; 3.14{\pm}0.63$) and Alzheimer's disease; AD (3.33 $\pm$0.60, 3.29$\pm$0.79, 3.31$\pm$0.70), but were higher than those of Parkinson's disease; PD (1.92$\pm$0.74, 1.39$\pm$0.68, 1.64$\pm$0.68), multiple system atrophy; MSA (2.36$\pm$1.07, 2.16$\pm$0.91, 2.26$\pm$0.96), and dementia with Lewy body; DLB (1.95$\pm$0.72, 1.64$\pm$0.65, 1.79$\pm$0.66)(p<0.005). PD had statisticalIy lower values of PER and higher values of ASI than those of NC (p<0.005). And PD had significantIy lower value of PCR, higher ASI and lower BP in the putamen and whole striatum than MSA (p<0.05). Conclusion: Dopamine transporter image of $^{123}I-FP-CIT$ SPECT was a good value in differential diagnosis of parkinsonism.

Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films (사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름)

  • Jang Ji-Sun;Shin Dong-Oh;Choi Byung-Ock;Lee Tae-Kyu;Choi Ihl-Bohng;Kim Moon-Chan;Kwon Soo-Il;Kang Young-Nam
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • The accuracy of the dosimetry in the Cyberknife system is accomplishing important role from all processes of the stereotactic radiosurgery. In this study, we estimated relative output factors for Cyberknife. All measurements were peformed by six different detectors: diode detector, X-Omat V film, Gafchromic EBT film, 0.015 cc, 0.125 cc and 0.6 cc ionization chamber The diode detector and three ionization chambers peformed using water phantom at 80 cm SSD and 1.5 cm depth. When the film measurements were peformed, the water phantom was replaced with a solidwater phantom. Each collimator normalized with respect to the output factor of the largest collimator (60 mm). For the collimators over than 30 mm, the output factors from the different detectors showed a good agreement within 0.5% except 0.6 cc ion chamber For the collimators less than 15 mm, there were substantial differences In the output factors among different detectors. That is, the value of output factor for the 5 mm collimator of a diode and Gafchromic film was each $0.656{\pm}0.009$ and $0.777{\pm}0.013$. In the ion chamber and diode detector, those difference were due to the presence of large dose gradients and lack of electronic equilibrium in narrow megavoltage x-ray beams Therefore, the Gafchromic EBT film were considered more accurate than the others detectors.

  • PDF

The Serial Change of Cerebral Hemodynamics by Vascular Territory after Extracranial-Intracranial Bypass Surgery in Patients with Atherosclerosis of Cerebral Arteries (죽상 동맥 경화성 뇌혈관 폐색 환자에서의 두개외강-내강 우회로술 후의 혈관 영역별 연속 혈류역학 변화)

  • Hong, Il-Ki;Kim, Jae-Seung;Ahn, Jae-Sung;Kwon, Sun-Uck;Im, Ki-Chun;Lee, Jai-Hyuen;Moon, Dae-Hyuk
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.8-16
    • /
    • 2008
  • Purpose: To assess the effect of extracranial-intracranial (EC-IC) bypass surgery on hemodynamic improvement, we evaluated serial regional cerebral hemodynamic change of the middle cerebral artery (MCA) in symptomatic patients with atherosclerotic occlusion of the internal carotid artery (ICA) or MCA using $^{99m}Tc$-ECD acetazolamide stress brain perfusion SPECT (Acetazolamide SPECT). Materials and Methods: The patients who had suffered a recent stroke with atherosclerotic ICA or MCA occlusion underwent EC-IC bypass surgery and Acetazolamide SPECT at 1 week before and three to six months after surgery. For image analysis, attenuation corrected images were spatially normalized to SPECT templates with SPM2. Anatomical automated labeling was applied to calculate mean counts of each Volume-Of-Interest (VOI). Seven VOIs of bilateral frontal, parietal, temporal regions of the MCA territory and the ipsilateral cerebellum were defined. Using mean counts of 7 VOIs, cerebral perfusion index and perfusion reserve index were calculated. Results: Seventeen patients (M:F =12:5, mean age $53{\pm}2yr$) were finally included in the analysis. The cerebral blood flow of the parietal region increased at 1 week (p = 0.003) and decreased to the preoperative level at 3-6 months (p = 0.003). The cerebrovascular reserve of the frontal and parietal regions increased significantly at 1 week after surgery (p<0.01) and improved further at 3-6 months. Conclusion: Cerebrovascular reserve of the MCA territory was significantly improved at early postoperative period after EC-IC bypass and kept improved state during long-term follow-up, although cerebral blood flow did not significantly improved. Therefore, cerebrovascular reserve may be a good indicator of postoperative hemodynamic improvement resulted from bypass effect.

The Study of Land Surface Change Detection Using Long-Term SPOT/VEGETATION (장기간 SPOT/VEGETATION 정규화 식생지수를 이용한 지면 변화 탐지 개선에 관한 연구)

  • Yeom, Jong-Min;Han, Kyung-Soo;Kim, In-Hwan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.4
    • /
    • pp.111-124
    • /
    • 2010
  • To monitor the environment of land surface change is considered as an important research field since those parameters are related with land use, climate change, meteorological study, agriculture modulation, surface energy balance, and surface environment system. For the change detection, many different methods have been presented for distributing more detailed information with various tools from ground based measurement to satellite multi-spectral sensor. Recently, using high resolution satellite data is considered the most efficient way to monitor extensive land environmental system especially for higher spatial and temporal resolution. In this study, we use two different spatial resolution satellites; the one is SPOT/VEGETATION with 1 km spatial resolution to detect coarse resolution of the area change and determine objective threshold. The other is Landsat satellite having high resolution to figure out detailed land environmental change. According to their spatial resolution, they show different observation characteristics such as repeat cycle, and the global coverage. By correlating two kinds of satellites, we can detect land surface change from mid resolution to high resolution. The K-mean clustering algorithm is applied to detect changed area with two different temporal images. When using solar spectral band, there are complicate surface reflectance scattering characteristics which make surface change detection difficult. That effect would be leading serious problems when interpreting surface characteristics. For example, in spite of constant their own surface reflectance value, it could be changed according to solar, and sensor relative observation location. To reduce those affects, in this study, long-term Normalized Difference Vegetation Index (NDVI) with solar spectral channels performed for atmospheric and bi-directional correction from SPOT/VEGETATION data are utilized to offer objective threshold value for detecting land surface change, since that NDVI has less sensitivity for solar geometry than solar channel. The surface change detection based on long-term NDVI shows improved results than when only using Landsat.