• Title/Summary/Keyword: normalized k

Search Result 2,395, Processing Time 0.033 seconds

Bone marrow stem cells incubated with ellipticine regenerate articular cartilage by attenuating inflammation and cartilage degradation in rabbit model

  • Mohammad Amjad Hossain;Soyeon Lim;Kiran D. Bhilare;Md Jahangir Alam;Baicheng Chen;Ajay Vijayakumar;Hakyoung Yoon;Chang Won Kang;Jong-Hoon Kim
    • Journal of Veterinary Science
    • /
    • v.24 no.6
    • /
    • pp.83.1-83.12
    • /
    • 2023
  • Background: Ellipticine (Ellip.) was recently reported to have beneficial effects on the differentiation of adipose-derived stem cells into mature chondrocyte-like cells. On the other hand, no practical results have been derived from the transplantation of bone marrow stem cells (BMSCs) in a rabbit osteoarthritis (OA) model. Objectives: This study examined whether autologous BMSCs incubated with ellipticine (Ellip.+BMSCs) could regenerate articular cartilage in rabbit OA, a model similar to degenerative arthritis in human beings. Methods: A portion of rabbit articular cartilage was surgically removed, and Ellip.+BMSCs were transplanted into the lesion area. After two and four weeks of treatment, the serum levels of proinflammatory cytokines, i.e., tumor necrosis factor α (TNF-α) and prostaglandin E2 (PGE2), were analyzed, while macroscopic and micro-computed tomography (CT) evaluations were conducted to determine the intensity of cartilage degeneration. Furthermore, immuno-blotting was performed to evaluate the mitogen-activated protein kinases, PI3K/Akt, and nuclear factor-κB (NF-κB) signaling in rabbit OA models. Histological staining was used to confirm the change in the pattern of collagen and proteoglycan in the articular cartilage matrix. Results: The transplantation of Ellip.+BMSCs elicited a chondroprotective effect by reducing the inflammatory factors (TNF-α, PGE2) in a time-dependent manner. Macroscopic observations, micro-CT, and histological staining revealed articular cartilage regeneration with the downregulation of matrix-metallo proteinases (MMPs), preventing articular cartilage degradation. Furthermore, histological observations confirmed a significant boost in the production of chondrocytes, collagen, and proteoglycan compared to the control group. Western blotting data revealed the downregulation of the p38, PI3K-Akt, and NF-κB inflammatory pathways to attenuate inflammation. Conclusions: The transplantation of Ellip.+BMSCs normalized the OA condition by boosting the recovery of degenerated articular cartilage and inhibiting the catabolic signaling pathway.

Activation of Paraspinal, Abdominal, and Hip Muscles During Various Low Back Stabilization Exercises in Males and Females

  • Yoo, Won-Gyu;Lee, Hyun-Ju
    • Physical Therapy Korea
    • /
    • v.11 no.4
    • /
    • pp.19-29
    • /
    • 2004
  • Many muscles of the trunk and hip are capable of contributing to the stabilization and protection of the lumbar spine. To have optimal effectiveness, a training program should include dynamic back/stomach/hip exercises. This study was designed to assess the L5 level paraspinal, external abdominal oblique, and gluteus maximus muscle activities during various low back stabilization exercises. Participants were 26 healthy adults (13 males, 13 Females), aged 21 to 28 years. The surface electromyography (EMG) was recorded from the L5 level paraspinal, external abdominal oblique, and gluteus maximus muscles. The recorded signal was averaged and normalized to the maximal electromyographic amplitude obtained during the maximal voluntary contraction. The measurements were taken during 3 low back stabilization exercises. One-way analysis of variance with repeated measures was used to examine the difference, and a post hoc test was performed with least significant difference. A level of significance was set at p<.05. The significance of difference between men and women, and between the electromyographic recording sites was evaluated by an independent t-test. The EMG activity for the externus oblique and gluteus maximus muscles had significant differences among 3 exercises (p<.05). In males, the EMG activity for the external abdominal oblique muscle had significantly increased differences during exercises 1 and exercise 2 (p<.05). The gluteus maximus muscle had significantly increased differences during exercise 2 and exercise 3 (p<.05). In females, the multifidus muscle had significantly increased difference during exercise 3 (p<.05), the external abdominal oblique muscle had significantly increased difference during exercise 1 (p<.05). and the gluteus maximus muscle had significantly decreased difference during exercise 3 (p<.05). The results were that the external abdominal oblique muscle was apparently activated during the curl-up exercise in females and males, and the multifidus muscle was apparently activated during the bridging exercise in females and during the sling exercise in males and females.1)In comparison of the %MVC between males and females, exercise 2 and exercise 3 apparently activated of the multifidus and gluteus maximus muscles in both males and females (p<.05). The EMG activity of the gluteus maximus muscle of the males significantly increased during exercise 2 and exercise 3 (p<.05). The EMG activity the multifidus muscle of the females was significantly increased during exercise 2 and exercise 3 (p<.05). More research is needed to understand the nature of motor control problems in the deep muscles in patients with low back pain.

  • PDF

Physicochemical Heterogeneity of the Supply Water Quality depending on Seasonal Changes in the Taejon Area, Korea (대전지역 상수도 물의 계절변화에 따른 물리화학적 불균질)

  • 이현구;이찬희;서호택
    • Economic and Environmental Geology
    • /
    • v.33 no.6
    • /
    • pp.505-517
    • /
    • 2000
  • This study was undertaken to provide a drinking water quality on the basis of physicochemical properties. In this study, the 25 samples of supply waters of the Taejon area were sampled twice (February and August in 1999). Hydrochemistry of the supply water belongs to the $Ca^{2+}$-${HCO_3}^{-1}$ type, whereas the supply water was characterized by the relatively significant enrichment of ${Ca}^{2+}$, ${Na}^{2+}$, ${K}^{2+}$, ${Cl}^{2+}$ ions and heavy metals compared to the original water from the Daecheong lake. Generally, the supply water has a mean values for $10.7^{\circ}C$ of temperature, 6.86 of pH, -12 mV of Eh, 88 ${\mu}S$/cm of EC and 70.379 mg/l of TDS in February, whereas the waters of the same sites in August are a slightly high temperature ($26.1^{\circ}C$), TDS (78.069 mg/l) and extremely high EC (442 ${\mu}S$/cm) value. These values are similar with physicochemical properties of the original lake water depending on the seasonal differences. Results of speciation calculation indicate that potentially toxic ions might exist mainly in the forms of free metal (${Cu}^{2+}$ or ${Zn}^{2+}$) and a small amount of ${CO_3}^{2-}$and ${OH}^{-}$in the supply water. The water seemed to be in equilibrium with kaolinite field of the normal stability diagrams for the natural water. Based on enrichment parameter of the supply water normalized by original lake water composition, the average value of those parameter can be calculated with nearly 1.00, but the those values for Cu+Zn possible source of decrepit pipe lines are 126.75 in February and 115.63 in August samples. The parameter values varied with sampling sites, however, do not exceed by chemistry of drinking water standard. Solid compounds remained on the membrane filter papers after filtration are adhered to pale yellow or yellowish brown colored dissolved solids and precipitates, which are coated by 0.02 to 0.35 mm thick per 500 ml with colloidal particles of about 1 to 2${\mu}m$ size. The particles are mainly Fe-Cu-Zn compounds and partly detected to Mn and Pb.

  • PDF

Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass (박동류 및 비박동류에 의한 체외순환의 비교)

  • Sun, Kyung;Baek, Kwang-Je;Kim, Yo-Han;Kim, Chang-Young;Kim, Kwang-Taek;Kim, Hark-Jei;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

Underdetermined blind source separation using normalized spatial covariance matrix and multichannel nonnegative matrix factorization (멀티채널 비음수 행렬분해와 정규화된 공간 공분산 행렬을 이용한 미결정 블라인드 소스 분리)

  • Oh, Son-Mook;Kim, Jung-Han
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.2
    • /
    • pp.120-130
    • /
    • 2020
  • This paper solves the problem in underdetermined convolutive mixture by improving the disadvantages of the multichannel nonnegative matrix factorization technique widely used in blind source separation. In conventional researches based on Spatial Covariance Matrix (SCM), each element composed of values such as power gain of single channel and correlation tends to degrade the quality of the separated sources due to high variance. In this paper, level and frequency normalization is performed to effectively cluster the estimated sources. Therefore, we propose a novel SCM and an effective distance function for cluster pairs. In this paper, the proposed SCM is used for the initialization of the spatial model and used for hierarchical agglomerative clustering in the bottom-up approach. The proposed algorithm was experimented using the 'Signal Separation Evaluation Campaign 2008 development dataset'. As a result, the improvement in most of the performance indicators was confirmed by utilizing the 'Blind Source Separation Eval toolbox', an objective source separation quality verification tool, and especially the performance superiority of the typical SDR of 1 dB to 3.5 dB was verified.

The Validation of Landsat TM Band Ratio Algorithm using In-water Optical Measurement (수중 광학측정을 이용한 Landsat TM 밴드비율 알고리듬 검증)

  • Jeong, Jong-Chul
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.4 no.1
    • /
    • pp.18-26
    • /
    • 2001
  • Landsat TM band ratio algorithms were made by in-water optical measurement data of each sampling points for water quality monitoring of coastal area using Landsat TM satellite data. The algorithm was derived from in-water optical reflectance data which was measuring by the PRR(profiling reflectance radiometer). And, in-water optical reflectance data were applied to Landsat TM bands. Relationship between in-water optical reflectance and pigments proposed by the ratio of TM band 1 and band 2 showed to as follows; $Y=3.8352{\times}(R(band\;1)/R(band\;2))^{-2.1978}$ ($R^2$=0.7069) and, relationship of the ratio of TM band 1 and band 3 as follows; $Y=23.288{\times}(R(band\;1)/R(band\;3))^{-1.5243}$ ($R^2$=0.8062). Calculated the upwelling radiance of water surface and radiance of TM showed the ratio of atmospheric effect. In the coastal area Rayleigh and Mie scattering of atmosphere is to make over 80% of normalized radiance of Landsat TM. In order to apply in-water algorithm obtained by PRR, we had to calculate the atmospheric effects at sampling site. And, the quantitative analysis of in-water components using Landsat TM data need the calibration of in-water algorithm and effective method of atmospheric correction.

  • PDF

Compatibility of MODIS Vegetation Indices and Their Sensitivity to Sensor Geometry (MODIS 식생지수에 미치는 센서 geometry의 영향과 센서 간 자료 호환성 검토)

  • Park, Sunyurp
    • Journal of the Korean Geographical Society
    • /
    • v.49 no.1
    • /
    • pp.45-56
    • /
    • 2014
  • Data composite methods have been typically applied to satellite-based vegetation index(VI) data to continuously acquire vegetation greenness over the land surface. Data composites are useful for construction of long-term archives of vegetation indices by minimizing missing data or contamination from noise. In addition, if multi-sensor vegetation indices that are acquired during the same composite periods are used interchangeably, data stability and continuity may be significantly enhanced. This study evaluated the influences of sensor geometry on MODIS vegetation indices and investigated data compatibility of two difference vegetation indices, the Normalized Difference Vegetation Index(NDVI) and the Enhanced Vegetation Index(EVI), for potential improvement of long-term data construction. Relationships between NDVI and EVI turned out statistically significant with variations among vegetation covers. Due to their curvilinear relationships, NDVI became saturated and leveled off as EVI reached high ranges. Correlation coefficients between Terra- and Aqua-based vegetation indices ranged from 0.747 to 0.963 for EVI, and from 0.641 to 0.880 for NDVI, showing better compatibility for EVI compared to NDVI. In-depth analyses of VI outliers that deviated from regression equations constructed from the two different sensors remain as a future study to improve their compatibility.

  • PDF

Security of Image Information using Steganography and QR Code in IoT (IoT에서 스테가노그라피와 QR 코드를 이용한 영상 정보의 보안)

  • Im, Yong-Soon;Kang, Eun-Young;Park, Jae-Pyo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.31-37
    • /
    • 2015
  • The security of the image information is very important in many areas of the IoT(Internet of Things), and study a number of ways to display the security (copyright, etc.). In this paper, information of image that is used by the IoT is converted to a DCT(Discrete Cosine Transform) and QC(Quantization Coefficient). And watermark (message) is to create a new encoded message(WMQR) through a QR Code. QC and WMQR applies LSB steganography techniques, can get the security (copyright, etc.) of image information. LSB steganographic techniques may be inserted according to a message (Watermark) to determine the location (Secret Key). The encoded image is sent to the recipient via the Internet. The reverse process can be obtained image and a QR code, a watermark (Message). A method for extracting a watermark from the security of the image information is coded using only the image and Secret Key, through the DCT and quantization process, so obtained by separating the watermark (Message) for the image. In this paper, we were able to improve the security of the method of image information, the image quality of the image by the simulations (PSNR), in turn, benefits were also normalized correlation (NC) and security.

Extraction of the Tree Regions in Forest Areas Using LIDAR Data and Ortho-image (라이다 자료와 정사영상을 이용한 산림지역의 수목영역추출)

  • Kim, Eui Myoung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.2
    • /
    • pp.27-34
    • /
    • 2013
  • Due to the increased interest in global warming, interest in forest resources aimed towards reducing greenhouse gases have subsequently increased. Thus far, data related to forest resources have been obtained, through the employment of aerial photographs or satellite images, by means of plotting. However, the use of imaging data is disadvantageous; merely, due to the fact that recorded measurements such as the height of trees, in dense forest areas, lack accuracy. Within such context, the authors of this study have presented a method of data processing in which an individual tree is isolated within forested areas through the use of LIDAR data and ortho-images. Such isolation resulted in the provision of more efficient and accurate data in regards to the height of trees. As for the data processing of LIDAR, the authors have generated a normalized digital surface model to extract tree points via local maxima filtering, and have additionally, with motives to extract forest areas, applied object oriented image classifications to the processing of data using ortho-images. The final tree point was then given a figure derived from the combination of LIDAR and ortho-images results. Based from an experiment conducted in the Yongin area, the authors have analyzed the merits and demerits of methods that either employ LIDAR data or ortho-images and have thereby obtained information of individual trees within forested areas by combining the two data; thus verifying the efficiency of the above presented method.

Signatures Verification by Using Nonlinear Quantization Histogram Based on Polar Coordinate of Multidimensional Adjacent Pixel Intensity Difference (다차원 인접화소 간 명암차의 극좌표 기반 비선형 양자화 히스토그램에 의한 서명인식)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.375-382
    • /
    • 2016
  • In this paper, we presents a signatures verification by using the nonlinear quantization histogram of polar coordinate based on multi-dimensional adjacent pixel intensity difference. The multi-dimensional adjacent pixel intensity difference is calculated from an intensity difference between a pair of pixels in a horizontal, vertical, diagonal, and opposite diagonal directions centering around the reference pixel. The polar coordinate is converted from the rectangular coordinate by making a pair of horizontal and vertical difference, and diagonal and opposite diagonal difference, respectively. The nonlinear quantization histogram is also calculated from nonuniformly quantizing the polar coordinate value by using the Lloyd algorithm, which is the recursive method. The polar coordinate histogram of 4-directional intensity difference is applied not only for more considering the corelation between pixels but also for reducing the calculation load by decreasing the number of histogram. The nonlinear quantization is also applied not only to still more reflect an attribute of intensity variations between pixels but also to obtain the low level histogram. The proposed method has been applied to verified 90(3 persons * 30 signatures/person) images of 256*256 pixels based on a matching measures of city-block, Euclidean, ordinal value, and normalized cross-correlation coefficient. The experimental results show that the proposed method has a superior to the linear quantization histogram, and Euclidean distance is also the optimal matching measure.