• Title/Summary/Keyword: normal section

Search Result 657, Processing Time 0.037 seconds

Ultimate section capacity of steel thin-walled I-section beam-columns

  • Salem, Adel Helmy;Sayed-Ahmed, Ezzeldin Yazeed;El-Serwi, Ahmed Abdelsalam;Korashy, Mohamed Mostafa
    • Steel and Composite Structures
    • /
    • v.4 no.5
    • /
    • pp.367-384
    • /
    • 2004
  • A numerical model based on the finite element technique is adopted to investigate the behavior and strength of thin-walled I-section beam-columns. The model considers both the material and geometric nonlinearities. The model results were first verified against some of the currently available experimental results. A parametric study was then performed using the numerical model and interaction diagrams for the investigated beam-columns have been presented. The effects of the web depth-to-thickness ratio, flange outstand-to-thickness ratio and bending moment-to-normal force ratio on the ultimate strength of thin-walled I-section beam-columns were scrutinized. The interaction equations adopted for beam columns design by the NAS (North American Specifications for the design of cold formed steel structural members) have been critically reviewed. An equation for the buckling coefficient which considers the interaction between local buckling of the flange and the web of a thin-walled I-section beam-column has been proposed.

Condylar Hyperplasia with Long-standing Temporomandibular Joint Dislocation

  • Kim, Il-Kyu;Cho, Hyun-Young;Jung, Bum-Sang;Pae, Sang-Pill;Cho, Hyun-Woo;Seo, Ji-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.1
    • /
    • pp.16-20
    • /
    • 2014
  • Mandibular condylar hyperplasia is an uncommon condition of excessive unilateral growth of the condyle causing facial asymmetry and occlusal alterations. The etiology of condylar hyperplasia is unclear, but several factors are suspected, including previous trauma, hormonal disturbances, and abnormal functional loadings. Acute or chronic recurrent dislocation of temporomandibular joint (TMJ) is common, but long-standing dislocation is rare. We present two cases of the exophytic condylar hyperplasia that lasted for over 20 years with TMJ dislocation. In both cases, we performed a condyloplasty to restore normal occlusion and facial symmetry, with satisfactory results.

A Study on the Refrigerant Distribution in an Aluminum Parallel Flow Heat Exchanger Header (알루미늄 평행류 열교환기 헤더 내 냉매 분배에 관한 연구)

  • Kim, Do-Young;Kim, Nae-Hyun;Kim, Su-Hwan;Byun, Ho-Won;Lee, Eul-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1123-1128
    • /
    • 2009
  • The refrigerant R-134a flow distributions are experimentally studied for a round header/ten flat tube test section simulating a brazed aluminum heat exchanger. Three different inlet orientations (parallel, normal, vertical) were investigated. Tests were conducted with downward flow for the mass flux from 70 to $130\;kg/m^2s$ and quality from 0.2 to 0.6. In the test section, tubes were flush-mounted with no protrusion into the header. It is shown that normal and vertical inlet yielded approximately similar flow distribution. At high mass fluxes or high qualities, however, slightly better results were obtained for normal inlet configuration. The flow distribution was worst for the parallel inlet configuration. Possible explanation is provided based on flow visualization results.

  • PDF

Research on desorption and stability of benzene, toluene, acetone and n-hexane of activated carbon acquired from domestic market (국내 시판 중인 활성탄을 이용한 벤젠, 톨루엔, 아세톤 및 노말 헥산의 탈착 및 저장성 평가 연구)

  • Lee, Naroo;Yi, Gwangyong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.353-358
    • /
    • 2014
  • Purpose: This study was conducted to evaluate desorption efficiency and storage stability on activated carbon acquired form domestic market. Materials: Mixture of acetone, benzene, normal hexane and toluene was injected on four types of charcoal 100 mg. After overnight, charcoal was desorbed by carbon disulfide $1m{\ell}$ and analyzed by gas chromatography with flame ionization detector. Results: Desorption efficiency of benzene, normal hexane and toluene in charcoal tubes were 95% ~ 105%. But desorption efficiency of acetone in charcoal tubes was below 75% and different from types of charcoal. The more injected amount of acetone on charcoal showed higher desorption efficiency. Acetone injected on charcoal tubes migrated from front section into back section after 10 days storage at room temperature. Conclusions: Desorption efficiency and storage stability of activated carbon acquired from domestic market was good for benzene, normal hexane and toluene. The activated carbon acquired from domestic market has ability to be used as sampling media.

Planning and decommissioning of a disused Theratron- 780 teletherapy machine and the dose assessment methodology for normal and radiological emergency conditions

  • Mohamed M.Elsayed Breky ;Muhammad S. Mansy;A.A. El-Sadek ;Yousif M. Mousa ;Yasser T. Mohamed
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.238-247
    • /
    • 2023
  • The present work represents a technical guideline for decommissioning a disused teletherapy machine model Theratron-780 and contains category one 60Co radioactive source. The first section predicts the dose rate from the source in case of normal and radiological emergency situations via FLUKA-MC simulation code. Moreover, the dose assessment for the occupational during the whole process is calculated and compared to the measured values. A suggested cordoned area for safety and security in a radiological emergency is simulated. The second section lists the whole process's technical procedures, including (preview, dismantle, securing, transport and storage) of the disused teletherapy machine. Results show that the maximum obtained accumulated dose for occupational were found to be 24.5 ± 4.9 μSv in the dismantle and securing process in addition to 3.5 ± 1.8 μSv during loading on the transport vehicle and unloading at the storage facility. It was found that the measured accumulated dose for workers is in good agreement with the estimated one by uncertainty not exceeding 5% in normal operating conditions.

The Experimental Study of Inorganic Performanent내s of Fire Resistance Evaluation (무기질계 영구거푸집의 내화성능에 관한 실험적 연구)

  • 김영진;백민수;정근호;김우재;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.495-500
    • /
    • 2002
  • The purpose of this study is to develop and to apply this permanent cement mortar form as one of those system forms to improve existing form's problems. (1) In the fire proof test with combined specimen, the fire proof covering including form section thickness is satisfied with the fire proof criterion. It is considered that form section thickness has no problem (2) The suitable method of normal pressure steam curing for the form's mass production is 4 hours in 65℃ considering production cost, the silica fume admixture is economic.

  • PDF

Vacuum system for PAL-XFEL (4세대방사광가속기 진공시스템)

  • Na, Donghyun
    • Vacuum Magazine
    • /
    • v.4 no.1
    • /
    • pp.12-15
    • /
    • 2017
  • The Pohang Accelerator Laboratory X-ray Free Electron Laser (PAL-XFEL) is a 0.1 nm hard X-ray FEL which aims at providing photon flux higher than $1{\times}10^{12}$ photons/pulse using a 10-GeV electron linac. The vacuum system of the machine consists of an injector section including an S-band photocathode RF gun, 10-GeV electron linac section based on S-band normal conducting accelerating structures and a 150-m long out-vacuum undulator system. We introduce the present status of PAL-XFEL vacuum systems.

Study of statistical distribution for four-port TEM cell

  • Jeon, Sangbong;Kwon, Jong-Hwa
    • Journal of Multimedia Information System
    • /
    • v.1 no.2
    • /
    • pp.127-132
    • /
    • 2014
  • The transverse electromagnetic (TEM) cells are widely used for electromagnetic compatibility (EMC) testing and field probe calibrations. We propose the verification of TEM mode with statistical method using a four-port TEM cell. The verification results are compared with Normal, Rayleigh, and Gamma distribution. As a result, the 75 % quantile of the Rayleigh distribution is excellent agreement with the true quantiles for a number of calibration points.

  • PDF

Comparison of Acoustic Parameters According to the Section of Analysis in Sustained Vowel Phonation (모음연장 음성 샘플의 분석 구간에 따른 음향학적 파라미터 비교)

  • Shin, Yu-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.269-274
    • /
    • 2017
  • This study aimed to investigate the acoustic differences that occur in diverse sections of sustained vowel phonation, which is often used in an objective speech analysis of voice disorder patients. The subjects included 17 voice disorder patients (vocal nodules) and 12 normal individuals without any voice disorder. The participants' sustained vowel phonation of /a/ was divided into onset, middle, and offset, and the jitter, shimmer, and NHR in each section were analyzed using the MDVP(Multi-Dimensional Voice Program). The Friedman test and post hoc analysis were used. In the vocal nodules group, the jitter, shimmer and NHR were significantly higher in the off section of sustained vowel phonation than in the middle section, and there were no significant differences between the beginning and middle sections. In contrast, in the group of normal individuals, there were no significant differences between any of the sections. The values of the acoustic parameters according to the section of analysis in the sustained vowel phonation are different and the vocal in the end section is significantly more unstable than that in the middle section. The results of this study will be useful for selecting the sections to be analyzed in sustained vowel phonation and interpreting the results of the analysis.

GaAs Thin Films Grown on Conducting Glass by Hot Wall Epitaxy for Solar Cell

  • Tu, Jielei;Chen, Tingjin;Zhang, Chenjing;Shi, Zhaoshun;Wu, Changshu
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 2002
  • GaAs polycrystalline thin films with good performance were prepared on conducting glass by hot wall epitaxy (HWE), which were used for solar cell. Electron probe micro-analyzer (EPMA) was applied for the composition, morphology of surface and cross-section of grown films, and X-ray diffraction (XRD) for their phase structure; Raman scattering spectum (RSS) and photoluminescence (PL) were used for evaluating their optical characteristics. The results show that, there is textured structure on the surface of grown GaAs polycrystalline films, which is greatly promised to be suitable for the candidate of solar cell with low cost and high efficiency. It is concluded that the source and substrate at temperature of 900 ~ 930 $\^{C}$ and 500 $\^{C}$ respectively would be beneficial for such films.

  • PDF