• 제목/요약/키워드: normal resonance

검색결과 686건 처리시간 0.031초

THREE-DIMENSIONAL CRYSTALLIZING ${\pi}-BONDINGS,\;{\pi}-FAR$ INFRARED RAYS AND N-MACHINE

  • Oh, Hung-Kuk
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.34-44
    • /
    • 1996
  • N-machine produces more than input energy at above 3000 rpm. any space energy is absorbed when the N-machine is rotating at a very high velocity. Laws of electromagnetics verify that normal conduction is due to that electrons moves from one three-dimensional crystallizing ${\pi}-bonding$ orbital to next. The ${\pi}-far$ infrared rays are generated from the resonance and rotation of the electrons on the orbitals of three-dimensional crystallizing ${\pi}-bonding$ atoms. Material in universe is composed of ${\pi}-rays$, which have alternative outward electric field. If the alternative outward electric fields of the ${\pi}-rays$ are resonant each other they make attraction force, which is the gravity. The collection of space energy is due to a attraction force between the radially alternating electric field and the ${\pi}-far$ infrared rays in the space. Electrons flow by absorbed density difference of ${\pi}-far$ infrared rays along a conduction wire, which also verifies that normal electron conduction is due to a flow from one three-dimensional crystallizing ${\pi}-bonding$ orbital to next.

  • PDF

계란 크랙의 온라인 검출 (On-line Detection of Cracks in Eggshell)

  • 최완규;조한근;백진하;장영창;연광석;조성찬
    • Journal of Biosystems Engineering
    • /
    • 제24권3호
    • /
    • pp.253-258
    • /
    • 1999
  • This study was conducted to develop an automatic egg inspection system for detecting creaked eggs based on acoustic impulse response. This system includes a sound generator, a sound sensor with signal conditioner, and a computer. The sound generator that hit the sharp of the dull edges of an egg was constructed with a ceramic ball pendulum attached to a rotary type solenoid. The signal conditioner included a pre-amplifier and a digital signal processing (DSP) board. The parameters for distinguishing cracked and normal eggs were the area, the geometric centroid and the resonance frequency of power spectrum of the acoustic signal generated. An algorithm for on-line detection of the continuous transferring eggs was developed. The performance tests resulted with 91% success rate to separate cracked and normal eggs at the rate of 1 second per an egg.

  • PDF

A Case of Brachial Plexus Schwannoma

  • Kim, Young-Woo;Ahn, Sung-Ki;Song, Joon-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권5호
    • /
    • pp.396-399
    • /
    • 2006
  • Brachial plexus schwannoma is rare. A case of a 28-year old woman who complained of a palpable mass in the right axilla is presented. She had previous incisional biopsy on the axillary mass. Brachial plexus magnetic resonance imaging revealed a well circumscribed contrast enhancing mass on the right distal cord of the brachial plexus. EMG revealed normal. Tumor resection was performed with the transaxillary approach. Though dense granulation tissue obscured normal brachial plexus nerve anatomy, using the surgical microscope and nerve stimulator, grossly total tumor resection was performed. She is free of any neurologic symptom at three months postoperatively.

악성뇌종양 주변부위의 역동자기공명영상의 시간신호강도곡선 양상과 예후와의 관계

  • 최순섭;김기욱;허기영;이영일
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.21-21
    • /
    • 2003
  • 목적: 악성뇌종양 주변부위의 역동자기공명영상에서의 시간신호강도곡선 양상으로 종양의 성장 양상이나 예후를 판단할 수 있는지를 알고자 한다. 대상 및 방법: Anaplastic oligodendroglioma 3예, Anaplastic astrocytoma 1예, Glioblastoma multiforme 1예, Malignant ependymoma 2예, Medulloblastorna 1예로서, 총 8예의 종양절제전, 혹은 후의 잔류 종양을 대상으로 하였다. Routine MRI에 추가하여 종양부위에서 Turbo spin echo T1 강조 역동자기공명영상을 하였으며, Gd-DTPA 0.1 mmol/kg를 급속 주사 한 후, TR/TE, 350/15, slice thickness 6 mm, slice number 3, NEX 2회, scan time은 15 초로 하여 5 분 동안 20회 영상을 얻었다. 가시적으로 조영증강이 없는 종양의 주변부위나 수술경계부위에 관심영역을 그려서 시간신호강도곡선을 얻었으며, 첫 회 조영제 통과시의 peak 이후에 신호가 감소하는 경우를 Normal pattern으로, peak 이후에 신호가 계속 유지되거나 증가하는 경우를 Tumor pattern으로 하였으며, Normal pattern과 Tumor pattern을 보인 예들을 구분하여 종양의 재성장 상태와 환자의 생존 기간을 비교 관찰하였다.

  • PDF

Optical Properties of Long Wave Infrared Spoof Plasmon using Hexagonal Periodic Silver Hole Arrays

  • Lee, Byungwoo;Kwak, Hoe Min;Kim, Ha Sul
    • Applied Science and Convergence Technology
    • /
    • 제25권2호
    • /
    • pp.42-45
    • /
    • 2016
  • A two-dimensional metal hole array (2DMHA) structure is fabricated by conventional photo-lithography and electron beam evaporation. The transmittance of the 2DMHA is measured at long wave infrared (LWIR) wavelengths (${\lambda}{\sim}10$ to $24{\mu}m$). The 2DMHA sample shows transmittance of 70 and 67% at $15.4{\mu}m$ due to plasmonic resonance with perforated silver and gold thin films, respectively, under surface normal illumination at LWIR wavelengths. The measured infrared spectrum is separated into two peaks when the size of the hole becomes larger than a half-pitch of the hole array. Six degenerated plasmon modes (1,0) at the metal/Si surface split to three modes at an incident beam angle of $45^{\circ}$ with respect to the surface normal direction, and wavelength shifts of the transmitted spectrum are observed in a red shift and blue shift at the same time.

심도 청각장애 성인의 비성도 및 강도 (Nasalance and Intensity of Profound Hearing-Impaired Adults)

  • 최은아;박한상;성철재
    • 말소리와 음성과학
    • /
    • 제1권3호
    • /
    • pp.123-132
    • /
    • 2009
  • This study investigates the differences in nasalance across handicap, gender, and vowels and the correlation between nasal energy and oral energy both of which are used to compute nasalance. For this study, 20 hearing-impaired adults and 20 normal hearing adults as a control group were asked to read 7 Korean vowels (/$\alpha$, $\Lambda$, o, u, ɯ, i, $\varepsilon$/). Subjects' readings were recorded by NasalView and analyzed by Praat. Results showed that the hearing impaired group (HL) has a significantly higher nasalance than the normal hearing group(NH), and that there was a significant positive correlation between nasal energy and oral energy. A higher nasalance of the hearing impaired group seems to be due to an improper velopharyngeal control which is caused by lack of a proper auditory feedback.

  • PDF

In vivo Visualization of Human White Matter Tract by Diffusion Tensor Imaging Fiber Tractography (DTI-FT)

  • Lee, Seung-Koo;Kim, Dong-Ik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.85-85
    • /
    • 2002
  • Purpose: To evaluate the white matter fiber connectivity of normal human using diffusion tensor MRI. Method: Normal young healthy volunteers (2 women and 1 man) and 3 brain tumor patients participated in this study. All studies were performed using a 1.5T Philips Gyroscan Intern system. Diffusion weighted imaging was performed using single-shot echo planar imaging, with navigator echo phase correction and SENSE. Diffusion weighting was performed along six independent axes, using diffusion weighting of b=800s/$\textrm{mm}^2$. 128matrix, 23cm FOV, 2.5mm slice thickness were used for Imaging parameters. Data were processed on a Window-2000 PC equipped with IDL and PRIDE (Philips Medical System). Corticospinal tract was traced from mid-pons level via posterior limb of internal capsule. Corpus callosum, cerebellar peduncles and frontal fibers were traced by fiber tractography.

  • PDF

다공판 시스템의 접선입사 흡음성능에 관한 실험적 연구 (An Experimental Study on the Grazing Incidence Sound Absorption of a Perforated Panel System)

  • 제현수;양수영;홍병국;송화영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1052-1055
    • /
    • 2004
  • This paper introduces an experimental study on the grazing incidence sound absorptions for duct silencers filed with a glass wool and consisted of a perforated panel. The experimental results are discussed in comparison with the normal incidence sound absorption. And also the transmission loss for duct silencers are measured and compared with the sound absorption performances. From the experimental results, it is shown that the resonance frequency bandwidth on the transmission loss and sound absorption coefficient for duct silencers has a good agreement.

  • PDF

Invasive sphenoid sinus aspergillosis with normal findings on initial diagnostic tests that mimics Tolosa-Hunt syndrome-a diagnostic dilemma: a case report

  • Yu Hun Jeong;Jongsuk Choi;Byung-Jo Kim;Hung Youl Seok
    • Journal of Yeungnam Medical Science
    • /
    • 제40권2호
    • /
    • pp.198-201
    • /
    • 2023
  • Invasive sphenoid sinus aspergillosis can mimic Tolosa-Hunt syndrome (THS), leading to frequent misdiagnoses and potentially fatal consequences. We report a case of invasive sphenoid sinus aspergillosis initially misdiagnosed as THS. A 79-year-old man presented with right periorbital pain, ophthalmoplegia, and loss of vision. Initial evaluations including magnetic resonance imaging (MRI), were normal. He was first diagnosed with THS based on clinical features. The disease progressed despite high-dose intravenous steroid treatment, and an enhancing mass-like lesion was found in the right orbital apex, cavernous sinus, and sphenoid sinus on follow-up MRI. Aspergillosis was eventually confirmed by sphenoid sinus biopsy. The patient developed cerebral infarction and finally died despite being treated with amphotericin B. Given that invasive sphenoid sinus aspergillosis may initially resemble THS, high suspicion and rapid histological examination are important for diagnosis.

Preparation of Bi/Bi2MoO6 Plasmonic Photocatalyst with High Photocatalytic Activity Under Visible Light Irradiation

  • Zou, Chentao;Yang, Zhiyuan;Liang, Mengjun;He, Yunpeng;Yang, Yun;Yang, Shuijin
    • Nano
    • /
    • 제13권11호
    • /
    • pp.1850127.1-1850127.13
    • /
    • 2018
  • Bi metal deposited on $Bi_2MoO_6$ composite photocatalysts have been successfully synthesized via a simple reduction method at room temperature with using $NaBH_4$ as the reducing agent. The photocatalytic activity of the composite was evaluated by degradation of rhodamine B (RhB) and bisphenol A (BPA) solution under visible light. The rate constant of $Bi/Bi_2MoO_6$ composite to RhB is 10.8 times that of $Bi_2MoO_6$, and the degradation rate constant of BPA is 6.9 times of that of $Bi_2MoO_6$. Nitrogen absorption-desorption isotherm proved that the increase of specific surface area is one of the reasons for the improvement of photocatalytic degradation activity of $Bi/Bi_2MoO_6$ composites. The higher charge transfer efficiency of $Bi/Bi_2MoO_6$ is found through the characterization of the photocurrent and impedance, which are attributed to the surface plasmon resonance (SPR) effect produced by the introduction of the metal Bi monomer in the composite. Free radical capture experiments proved that cavitation is the main active species. Based on the above conclusions, a possible mechanism of photocatalytic degradation is proposed.