• Title/Summary/Keyword: normal resonance

Search Result 685, Processing Time 0.024 seconds

A New Soft Recovery Quasi-Resonance Pulse Width Modulating Boost Converter with Multiple Order Folding Snubber Network (다중 폴딩 스너버 망에 의한 새로운 펄스 폭 변조 의사 공진형 컨버터)

  • 정진국
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.3
    • /
    • pp.66-71
    • /
    • 2000
  • A new Soft Recovery Quasi-Resonant Converter (SR QRC) haying multiple order folding snubber network is proposed. It is combined with normal quasi-resonant converter with folding snubber network of which the surrounding components are composed of diodes and capacitors. The reverse recovery loss of main rectifier diode is eliminated by this method utilizing multiple resonance. The proposed converter has PWM capability with high efficiency and is suitable for high voltage and high power applications. By extension of this concept to other switching converters, a new family of SR PW QRC may be developed.

  • PDF

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

In vivo Imaging Biodistribution Profile of a New Macrocyclic Gadolinium Chelate as a Highly Stable Multifunctional MRI Contrast Agent

  • Sung, Bo Kyung;Jo, Yeong Woo;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.34-37
    • /
    • 2019
  • Gadolinium contrast agents (CAs) are integral components of clinical magnetic resonance imaging (MRI). However, safety concerns have arisen regarding the use of gadolinium CAs, due to their association with nephrogenic systemic fibrosis (NSF). Furthermore, recently the long-term retention of $Gd^{3+}-based$ CAs in brains patients with normal renal function raised another possible safety issue. The safety concerns of $Gd^{3+}-based$ CAs have been based on the ligand structure of $Gd^{3+}-based$ CAs, and findings that $Gd^{3+}-based$ CAs with linear ligand structures showed much higher incidences of NSF and brain retention of CAs than $Gd^{3+}-based$ CAs with macrocyclic ligand structure. In the current study, we report the in vivo biodistribution profile of a new highly stable multifunctional $Gd^{3+}-based$ CA, with macrocyclic ligand structure (HNP-2006). MR imaging using HNP-2006 demonstrated a significant contrast enhancement in many different organs. Furthermore, the contrast enhanced tumor imaging using HNP-2006 confirmed that this new macrocyclic CA can be used for detecting tumor in the central nervous system. Therefore, this new multifunctional HNP-2006 with macrocyclic ligand structure shows great promise for whole-body clinical application.

Left-Sided Cisterna Chyli: a Case Report on a Rare Normal Anatomic Structure

  • Seo, Jin Ho;Hwang, Jeong Ah;Shin, Hyeong Cheol;Kim, Seung Soo;Park, Chan Ho;Lee, Hyoung Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.276-278
    • /
    • 2019
  • The cisterna chyli, a dilated lymphatic sac in the retrocrural space, is usually located to the right of the aorta. We report a case of a left-sided cisterna chyli, which was incidentally detected on the radiologic examinations of a preoperative workup for cholangiocarcinoma. Computed tomography (CT) and magnetic resonance (MR) images revealed a cisterna chyli measuring 2.5 cm in length in the left retrocrural space. The dilated lumbar lymphatics joined with the cisterna chyli, which was continuous with the left-sided thoracic duct. To the best of our knowledge, this is the second antemortem case of a left-sided cisterna chyli in literature. The cisterna chyli can mimic retrocrural lymphadenopathy, solid tumor with cystic degeneration, abscess or hematoma. The left-sided cisterna chyli should be referred to as a structure so as to be cautious in surgical approach.

Assisted Magnetic Resonance Imaging Diagnosis for Alzheimer's Disease Based on Kernel Principal Component Analysis and Supervised Classification Schemes

  • Wang, Yu;Zhou, Wen;Yu, Chongchong;Su, Weijun
    • Journal of Information Processing Systems
    • /
    • v.17 no.1
    • /
    • pp.178-190
    • /
    • 2021
  • Alzheimer's disease (AD) is an insidious and degenerative neurological disease. It is a new topic for AD patients to use magnetic resonance imaging (MRI) and computer technology and is gradually explored at present. Preprocessing and correlation analysis on MRI data are firstly made in this paper. Then kernel principal component analysis (KPCA) is used to extract features of brain gray matter images. Finally supervised classification schemes such as AdaBoost algorithm and support vector machine algorithm are used to classify the above features. Experimental results by means of AD program Alzheimer's Disease Neuroimaging Initiative (ADNI) database which contains brain structural MRI (sMRI) of 116 AD patients, 116 patients with mild cognitive impairment, and 117 normal controls show that the proposed method can effectively assist the diagnosis and analysis of AD. Compared with principal component analysis (PCA) method, all classification results on KPCA are improved by 2%-6% among which the best result can reach 84%. It indicates that KPCA algorithm for feature extraction is more abundant and complete than PCA.

Fast Burt Imaging (고속 Burst 영상법 - pulse sequence 중심으로)

  • 강호경;노용만
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.13-19
    • /
    • 1999
  • MRI imaging provides many benefits such as noninvasive, 3-dimensional imaging capabilities. But it has relatively serious drawback that is the long data collection time, compared with other imaging modality. Many studies have been performed for fast MR imaging. But EPI and SEPI (4-6) are required to expensive hardware. In this paper, we introduce to Burst imaging technique. It can reduce imaging time by use of a mulitple RF excitation technique. Further it is easily implemented to the normal MRI system. But a pixel profile in the conventional burst sequence is so poor that excited area by burst sequence is a small portion of a pixel. This causes poor signal to noise ratio in burst image. therefore frequency sweeping of RF pulse for burst imaging sequence is proposed to improve pixel profile. A burst pulse train is shaped by liner or nonlinear frequency sweeping function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on how frequency sweep is made. Computer simulations with Bloch equation and experimental results obtained using a 1.0 T NMR imaging system are presented.

  • PDF

A Helmholtz Resonator Array Panel for Low Frequency Sound Absorption (저주파수 흡음을 위한 헬름홀쯔 공명기 배열형 패널)

  • Kim, Yang-Hann;Kim, SangRyul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.924-930
    • /
    • 2005
  • Sound absorptive materials have good performance in high frequency range, not at low frequencies. Therefore it has been great challenge to develop a sound absorbing structure that is good at low frequency. We propose to use a Helmholtz resonator array panel for this purpose. A Helmholtz resonator is one of noise control elements widely used in many practical applications. The resonator is a simple structure composed of a rigid-walled cavity with a neck, but it has very high performance at resonance frequency. This paper discusses the sound absorption of Helmholtz resonator array panels at normal and random incidence. First, various experimental results are introduced and studied. Secondly, we theoretically predict the absorptive characteristics of the resonator away panel. The theoretical approach is based on the Fourier analysis for a periodic absorber. We believe that this method can be used to design a panel for low frequency noise control.

Development of 'De novo' Aneurysm after Therapeutic Carotid Occlusion

  • Jin, Sung-Chul;Choi, Choong-Gon;Kwon, Do-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.236-239
    • /
    • 2009
  • Carotid occlusion is an inevitable therapeutic modality for the treatment of complex aneurysms such as giant, traumatic, and intracavernous aneurysms. Late complications of carotid occlusion include 'de novo' aneurysm formation at a distant site because of hemodynamic changes in the circle of Willis. We report a case of de novo aneurysm in a vessel that appeared to be normal on initial angiography. The patient developed an anterior communicating artery aneurysm and marked growth of a basilar bifurcation aneurysm 9 years after trapping of the left internal carotid artery for the treatment of a ruptured large saccular aneurysm involving ophthalmic and cavernous segments. We propose that patients who undergo therapeutic carotid occlusion should be periodically followed by magnetic resonance angiography or computed tomographic angiography to evaluate the possibility of de novo aneurysm formation; this advice is in line with previous reports.

Metabolic perturbation of an Hsp90 C-domain inhibitor in a lung cancer cell line, A549 studied by NMR-based chemometric analysis

  • Hur, Su-Jung;Lee, Hye-Won;Shin, Ai-Hyang;Park, Sung Jean
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.18 no.1
    • /
    • pp.10-14
    • /
    • 2014
  • Hsp90 is a good drug target molecule that is involved in regulating various signaling pathway in normal cell and the role of Hsp90 is highly emphasized especially in cancer cells. Thus, much efforts for discovery and development of Hsp90 inhibitor have been continued and a few Hsp90 inhibitors targeting the N-terminal ATP binding site are being tested in the clinical trials. There are no metabolic signature molecules that can be used to evaluate the effect of Hsp90 inhibition. We previously found a potential C-domain binder named PPC1 that is a synthetic small molecule. Here we report the metabolomics study to find signature metabolites upon treatment of PPC1 compound in lung cancer cell line, A549 and discuss the potentiality of metabolomic approach for evaluation of hit compounds.

Development of Quadrature Detection Surface Coil for Functional Magnetic Resonance Imaging at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.363-364
    • /
    • 2002
  • We describe quadrature type surface coil for functional magnetic resonance imaging at 3T MRI system. The coil consisted of two coplanar resonators and was used as both transmitter and receiver. The signal-to-noise ratio (SNR) of the coil was compared with that of a standard birdcage head coil. Visual cortex activation on normal subjects using LED flicker was performed. The SNR of surface coil was found to be better than that of the conventional head coil.

  • PDF