• Title/Summary/Keyword: normal operator

Search Result 282, Processing Time 0.039 seconds

Development of Diagnostic System for Winding Profile Abnormality of Hot Coils (열연코일 권취형상 불량 자동진단 시스템 개발)

  • Lee, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.590-595
    • /
    • 2000
  • On the contrary to the increasing needs of shape qualities, most of quality inspections are carried out by manual or operator's insight. To find the causes of shape inferiority, it is required to gather and analyze the shape measurement data. As a result the winding profile measurement system ($TELE-SCANNER^{(R)}$) is developed to analyze the coiling process and automate the manual measuring process for winding profile of hot-rolled coils. The winding profile measurement system measures and analyzes winding profile shapes of hot-rolled coils, and classifies them into several dominant patterns that are related to normal or abnormal mechanical conditions of down-coiler. The system also contains analysis software to quantify the winding profile shapes and patterns, and to produce statistics to help search the causes of profile shape inferiority.

  • PDF

New Two-Weight Imbedding Inequalities for $\mathcal{A}$-Harmonic Tensors

  • Gao, Hongya;Chen, Yanmin;Chu, Yuming
    • Kyungpook Mathematical Journal
    • /
    • v.47 no.1
    • /
    • pp.105-118
    • /
    • 2007
  • In this paper, we first define a new kind of two-weight-$A_r^{{\lambda}_3}({\lambda}_1,{\lambda}_2,{\Omega})$-weight, and then prove the imbedding inequalities for $\mathcal{A}$-harmonic tensors. These results can be used to study the weighted norms of the homotopy operator T from the Banach space $L^p(D,{\bigwedge}^l)$ to the Sobolev space $W^{1,p}(D,{\bigwedge}^{l-1})$, $l=1,2,{\cdots},n$, and to establish the basic weighted $L^p$-estimates for $\mathcal{A}$-harmonic tensors.

  • PDF

Design, Implementation and Validation of the KOMPSAT Spacecraft Simulator

  • Choi, Wan Sik;Lee, Sanguk;Eun, Jong Won;Choi, Han Jun;Chae, Dong Suk
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.50-67
    • /
    • 2000
  • The spacecraft simulator is used for command validation, operational check of the Satellite Operation Subsystem (SOS), spacecraft anomaly analysis support, satellite operator training etc. In this paper, S/W design features and modeling characteristics of the KOMPSAT Spacecraft Simulator Subsystem (SIM) are described. Validation procedures and simulation results are also provided. The SIM provides extensive simulation capabilities by including models for most of the spacecraft subsystems. The software structure of the SIM was designed and implemented so as to support operations not only in real-time but also in non real-time by utilizing the Hewlett Packard (HP) UNIX functions. The SIM incorporates as many user-friendly Man Machine Interface (MMI) windows as possible so that all the SIM normal operations can be executed through the MMI windows.

  • PDF

Study on Protective Coating Management Status in Overseas Nuclear Power Plant (해외 원자력발전소 방호도장 유지관리 현황 고찰)

  • Lim, Sang-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.318-319
    • /
    • 2018
  • Protective coatings at nuclear power plants should be designed to withstand exposure to ambient conditions during normal operation or design-basis accidents. However, there was a change in the perception of the protective coating to the revision of the Regulatory Guidelines by the NRC in July 2000. In other words, maintenance guidelines have been strengthened in order to minimize the clogging of the cooling water system due to the substances in the containment building. Therefore, KHNP, the contractor and operator of the nuclear power plant, plans to develop the coating system for nuclear power plants in accordance with the regulation, and plans to develop its own coating expert.

  • PDF

GENERALIZED MULTIVALUED QUASIVARIATIONAL INCLUSIONS FOR FUZZY MAPPINGS

  • Liu, Zeqing;Ume, Jeong-Sheok;Kang, Shin-Min
    • The Pure and Applied Mathematics
    • /
    • v.14 no.1 s.35
    • /
    • pp.37-48
    • /
    • 2007
  • In this paper, we introduce and study a class of generalized multivalued quasivariational inclusions for fuzzy mappings, and establish its equivalence with a class of fuzzy fixed-point problems by using the resolvent operator technique. We suggest a new iterative algorithm for the generalized multivalued quasivariational inclusions. Further, we establish a few existence results of solutions for the generalized multivalued quasivariational inclusions involving $F_r$-relaxed Lipschitz and $F_r$-strongly monotone mappings, and discuss the convergence criteria for the algorithm.

  • PDF

Human Sensitivity Responses to Vibrotactile Stimulation on the Hand : Measurement of Absolute Thresholds (진동식 촉각 자극에 대한 손의 절대 민감도 반응)

  • Lee, Seong-Il
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.1-10
    • /
    • 1998
  • The objective of this study is to investigate hwnan operator's perceptual and psychophysical responses to vibrotactile stimulation on various parts of the hand. Using a small vibrotactile display, five different loci of the hand along with two other mechanical parameters consisting vibrotactile stimulations, which are vibration frequency and number of active contactors, were examined for the effects on absolute thresholds. All test variables were found to have significant effects on thresholds. It was observed that absolute threshold is a function of vibration frequency and number of active contactors. Tactile sensitivity was the greatest at the vibration frequency of 240 Hz, and the fingertip was found to be the most sensitive locus on the hand. The area of stimulation on the hand was also found to be significant in that the sensitivity increased with the number of active contactors. The results of the study generally supported those of other previous studies. It should also be noted, however, that the conclusions from the study should be limited to the absolute sensitivity, not to the suprathreshold intensities of normal everyday contact with the hands.

  • PDF

Conservative surgical approach to aggressive benign odontogenic neoplasm: a report of three cases

  • Kumar, Vijay
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • Aggressive benign odontogenic neoplasms have substantial potential to grow to an enormous size with resulting bone deformities, and they often invade adjacent tissues and spread beyond their normal clinical and radiographic margins; as such, they have a high rate of recurrence. Historically, management (conservative versus aggressive) on the basis of clinical, radiographic and/or histopathologic characteristics has been controversial. However, recent advances in the understanding of the biological features of these lesions may provide greater evidence of the benefits of conservative management. Three patients with different complaints and final histopathologic diagnoses were enrolled in the study. All three cases were treated by a single operator with similar conservative surgical procedures. During follow-up, the patients had uneventful secondary healing and bone regeneration, less packing time than previously reported, no clinical or radiographic evidence of recurrence and no apparent deformity. The aggressive behavior of these lesions requires long clinical and radiographic follow-up. Conservative surgical management may be an option to reduce recurrence and morbidity and increase the probability of uneventful secondary healing and bone regeneration.

A Study on the Voltage Sags and Compensation of Large Industrial Distribution System using EMTDC (EMTDC를 이용한 대형 산업체 수전설비의 전압저감해석과 보상에 관한 연구)

  • Song, Bin-Tae;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1106-1110
    • /
    • 1998
  • Voltage Sags, different from electric outages, are important to industrial reliability because modern process controls are often sensitive to voltage sag, the designer and operator should recognize sag characteristics of the electric system not only to protect malfunction of equipment but also to make best choices between reliability and equipment cost. The voltage sags and compensation countermeasures of large md industrial distribution systems have been simulated using EMTDC. The causes of voltage sags occurred in the system are discussed in detail and several countermeasures including the transfer of large induction motor from normal power source to backup source are recommended in order to enhance the ride-through characteristics of equipments.

  • PDF

Study on Classification of Protective Coating Service Level in Nuclear Power Plant (원자력발전소 방호도장 Service Level 분류에 대한 고찰)

  • Lim, Sang-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.140-141
    • /
    • 2018
  • Protective coatings at nuclear power plants should be designed to withstand exposure to ambient conditions during normal operation or design-basis accidents. However, there was a change in the perception of the protective coating to the revision of the Regulatory Guidelines by the NRC in July 2000. In other words, maintenance guidelines have been strengthened in order to minimize the clogging of the cooling water system due to the substances in the containment building. Therefore, KHNP, the contractor and operator of the nuclear power plant, plans to develop the coating system for nuclear power plants in accordance with the regulation, and plans to develop its own coating expert.

  • PDF

Determining Contingency Ranking Using the Probabilistic Method of the Power System (확률적 방법을 이용한 전력계통의 상정사고 순위 결정)

  • Kim, Kyoung-Young;Lee, Seung-Hyuk;Kim, Jin-O;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.113-115
    • /
    • 2003
  • The electric power industry throughout the world is undergoing considerable changes from the vertically integrated utility structure to the deregulated market. However, the deregulated electricity market is operated with respect to theory of economical efficiency, and therefore, the system operator requires data with fast contingency ranking for security of the bulk power system. This paper presents fast calculation method for determining contingency ranking using the weather dependant probabilistic risk index(PRI). The probabilistic risk index can be classified into normal weather and adverse weather. This paper proposes calculation method using the probabilistic risk index in determining contingency ranking requiring for security under the deregulated electricity market.

  • PDF