• Title/Summary/Keyword: nonuniformity

Search Result 125, Processing Time 0.03 seconds

Nonuniformity of Energy Absorption Capabilities of ZnO Varistors

  • He, Jin-Liang;Han, Se-Won;Cho, Han-Goo;Kang, Hyung-Boo
    • The Korean Journal of Ceramics
    • /
    • v.4 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • The nonuniformity of energy absorption capability of ZnO varistor is systematically discussed in this paper. The nonuniformity of electrical characteristics and microstructure leads to decrease the energy absorption capability of ZnO varistor. The energy absorption capabilities were measured under different current waves, the experimental results stated that they have highly scattered phenomena. The influences of varistor surface area and nonuniformity of electrical characteristics to the energy absorption capability and the nonuniformity of commercial ZnO varistors were analyzed. There is a high nonuniformity existing in the energy absorption capability of commercial ZnO varistors.

  • PDF

Scene-based Nonuniformity Correction Algorithm Based on Temporal Median Filter

  • Geng, Lixiang;Chen, Qian;Qian, Weixian;Zhang, Yuzhen
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.255-261
    • /
    • 2013
  • Scene-based nonuniformity correction techniques for infrared focal-plane arrays have been widely considered as a key technology, and various algorithms have been proposed to compensate for fixed-pattern noise. However, the existed algorithms' capability is always restricted by the problems of convergence speed and ghosting artifacts. In this paper, an effective scene-based nonuniformity correction method is proposed to solve these problems. The algorithm is an improvement over the constant statistics method and a temporal median is utilized with the Gaussian kernel to estimate the nonuniformity parameters. Also theoretical analysis is conducted to demonstrate that effective ghosting artifacts elimination and superior convergence speed can be obtained with the proposed method. Finally, the performance of the proposed technique is tested with infrared image sequences with simulated nonuniformity and with infrared imagery with real nonuniformity. The results show the proposed method is able to estimate each detector's gain and to offset reliably and that it performs better in increasing convergence speed and reducing ghosting artifacts compared with the conventional techniques.

Reducing the Poly-Si TFT Nonuniformity by Transistor Slicing (다결정 실리콘 TFT의 불균일도 개선을 위한 트랜지스터 슬라이싱)

  • 이민호;이인환
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.261-264
    • /
    • 1999
  • This paper presents a circuit-level method to deal with transistor nonuniformity In this method, which is called transistor slicing, a transistor is implemented as a parallel connection of multiple smaller transistors. The paper analyzes the method and demonstrates that transistor slicing can effectively reduce the nonuniformity in TFT mobility and threshold voltage. The method is particularly useful in Implementing analog functions using poly-silicon TFTs which show a significant level of nonuniformity.

  • PDF

The improvement method for power plant boiler temperature nonuniformity of heat transfer tube bank flow path (발전용 보일러 전열 튜브 유로내 온도분포 불균일 개선기법)

  • Jung, Hoon;Kim, Bum-Shin;Jang, Suck-Won;Ahn, Yeon-Shik;Park, Gun-Bok;Whang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.837-841
    • /
    • 2001
  • Almost all power plant boiler has temperature distribution nonuniformity problem in heat transfer tube flow path. It can cause hot spot damage of superheated or reheated heat transfer section and reduce maintenance schedule when nonuniformity is severe. There are two solutions for improvement temperature nonuniformity. one is change of gas flow distribution of gas path and the other is contorl steam flow in tube bank. Of course, first method is very difficulty to apply but second method is'nt. In this paper, control steam flow is used to solve temperature nonuniformity of power plant boiler.

  • PDF

A Scene Based Nonuniformity Correction Technique of Linear Array Infrared Detector (선형배열 적외선 검출기의 배경 기반 불균일 보정기법)

  • 송인태;안상호
    • Proceedings of the IEEK Conference
    • /
    • 2000.11d
    • /
    • pp.73-76
    • /
    • 2000
  • A Scene Based Technique(SBT) that corrects linear array infrared detector's nonuniformity is proposed. Basically, this technique dispenses with using temperature references on a linear array infrared detector. To correct the nonuniformity of infrared images, we use three methods. Firstly, we detect bad channels by using the information which is cumulated all the same line pixels. Secondly, a variable window method is applied to compensate more accurately. Thirdly, an adaptive method which updates gain and offset coefficient is used only on a stationary region. These results are demonstrated on a computer simulation with various images. As a result, the nonuniformity is corrected completely, so that images are enhanced and PSNR(peak signal to noise ratio) is improved much.

  • PDF

Scene-based Nonuniformity Correction Complemented by Block Reweighting and Global Offset Initialization

  • Hong, Yong-hee;Lee, Keun-Jae;Kim, Hong-Rak;Jhee, Ho-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.8
    • /
    • pp.15-23
    • /
    • 2017
  • In this paper, the block reweighting and global offset initialization methods are proposed to complement the improved IRLMS algorithm which is the effective algorithm in registration based SBNUC algorithm. Proposed block weighting method reweights the error map whose abnormal data are excluded. The global offset initialization method compensates the global nonuniformity initially. The ordinary registration based SBNUC algorithm is hard to compensate global nonuniformity because of low scene motion. We employ the proposed methods to improved IRLMS algorithm, and apply it to real-world infrared raw image stream. The result shows that new implementation provides 3.5~4.0dB higher PSNR and convergence speed 1.5 faster then the improved IRLMS algorithm.

Thermal and flow analysis for the optimization of a parallel flow heat exchanger (평행류 열교환기의 열.유동 해석 및 최적화)

  • Lee, Gwan-Su;Jeong, Ji-Wan;Yu, Jae-Heung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.229-239
    • /
    • 1998
  • The present paper examines the thermal and flow characteristics of a parallel flow heat exchanger and investigates the effects of the parameters on thermal performance by defining the flow nonuniformity. Thermal performance of a parallel flow heat exchanger is maximized by the optimization using Newton's searching method. The flow nonuniformity is chosen as an object function. The parameters such as the locations of separator, inlet, and outlet are expected to have a large influence on thermal performance of a parallel flow heat exchanger. The effect of these parameters are quantified by flow nonuniformity. The results show that the optimal locations of inlet and outlet are 19.73 mm and 10.9 mm, respectively. It is also shown that the heat transfer increases by 7.6% and the pressure drop decreases by 4.7%, compared to the reference model.

A Study for plasma nonuniformity measurement by PDM Tool (PDM Tool을 이용한 plasma nonuniformity 측정에 관한 연구)

  • 김상용;서용진;이우선;정헌상;김창일;장의구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.75-78
    • /
    • 2000
  • This paper is estimated to enhance yield improvement and device reliability using PDM(plasma damage monitoring) system capable of in-suit detection about plasma nonuniformity. PDM Tool is the non-contact method of wafer and surface potential electrode(kelvin probe). Its tool measures Vox(oxide barrier) with charge created by plasma. It's possible to inspect the wafer damage generated by plasma charge and analysis of in-situ monitoring data. we obtained the good data which is continuously prevented from plasma damage using its tool for 10weeks. This tool is contributed to preventive steps contemporaneously inspecting the difference of inter-chamber.

  • PDF

Design and Implementation of Lamp-Heated LPCVD System (램프 가열 방식 LPCVD 장비의 설계 및 제작)

  • Ha, Yong-Min;Kim, Tae-Sung;Kim, Choong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.299-303
    • /
    • 1991
  • A lamp heated LPCVD equipment has been made. Wafer is heated by an array of fifteen tungsten halogen lamps above the front side of a wafer and pyrometer views the back side of the wafer through $CaF_2$ window. Reactor which consisits of a quartz window and a water cooled-stainless steel plate can be evacuated to $5{\times}10^{-3}$ torr with a rotary vane pump. By pyrolysis of $SiH_4$ at about $600^{\circ}C$, polysilicon has been formed on the silicon dioxide film. The measured results show that thickness nonuniformity is 15% and temperature nonuniformity is 1.1%. Because activation energy of pyrolysis of $SiH_4$ is very high, about 1.8eV, small temperature variation will induce large thickness nonuniformity. The main cause of temperature nonuniformity is unsymmetry of lamp power and an unbalanced cooling structure. Charls & Evans' SIMS result shows that the oxygen content in the deposited polysilicon is comparable to that of silicon substrate but carbon content is ten times higher.

  • PDF

Nonuniformity Correction Scheme Based on 3-dimensional Visualization of MRI Images (MRI 영상의 3차원 가시화를 통한 영상 불균일성 보정 기법)

  • Kim, Hyoung-Jin;Seo, Kwang-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.948-958
    • /
    • 2010
  • Human body signals collected by the MRI system are very weak, such that they may be easily affected by either external noise or system instability while being imaged. Therefore, this paper analyzes the nonuniformity caused by a design of the RF receiving coil in a low-magnetic-field MRI system, and proposes an efficient method to improve the image uniformity. In this paper, a method for acquiring 3D bias volume data by using phantom data among various methods for correcting such nonuniformity in MRI image is proposed, such that it is possible to correct various-sized images. It is shown by simulations that images obtained by various imaging methods can be effectively corrected using single bias data.