• 제목/요약/키워드: nonpremixed flame

검색결과 111건 처리시간 0.034초

Eulerian Particle Flamelet Modeling for Combustion Processes of Bluff-Body Stabilized Methanol-Air Turbulent Nonpremixed Flames

  • Kim, Seong-Ku;Kang, Sung-Mo;Kim, Yong-Mo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권9호
    • /
    • pp.1459-1474
    • /
    • 2006
  • The present study is focused on the development of the RIF (Representative Interactive Flamelet) model which can overcome the shortcomings of conventional approach based on the steady flamelet library. Due to the ability for interactively describing the transient behaviors of local flame structures with CFD solver, the RIF model can effectively account for the detailed mechanisms of $NO_x$ formation including thermal NO path, prompt and nitrous $NO_x$ formation, and reburning process by hydrocarbon radical without any ad-hoc procedure. The flamelet time of RIFs within a stationary turbulent flame may be thought to be Lagrangian flight time. In context with the RIF approach, this study adopts the Eulerian Particle Flamelet Model (EPFM) with mutiple flamelets which can realistically account for the spatial inhomogeneity of scalar dissipation rate. In order to systematically evaluate the capability of Eulerian particle flamelet model to predict the precise flame structure and NO formation in the multi-dimensional elliptic flames, two methanol bluffbody flames with two different injection velocities are chosen as the validation cases. Numerical results suggest that the present EPFM model has the predicative capability to realistically capture the essential features of flame structure and $NO_x$ formation in the bluff-body stabilized flames.

동축류 제트에서 전기장에 의한 화염 안정성 증진에 대한 실험적 연구 (Experimental Study on the Stability Enhancement of Nonpremixed Flames in Coflow Jets)

  • 원상희;류승관;정석호;차민석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2007년도 제34회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.191-196
    • /
    • 2007
  • The enhancement of flame stability in coflow jets has been investigated experimentally by observing the liftoff behaviors of nonpremixed propane and methane flames in the electric fields. The liftoff or blowoff velocities has been measured in terms of the applied AC voltages and frequency. The experimental results showed that the liftoff velocity could be extended significantly just by applying the high voltage to the central fuel nozzle both for propane and methane. As increasing the applied voltage, the liftoff velocity increases almost linearly with the applied voltage and have its maximum value at certain applied voltage. After that, the liftoff velocity showed decrease with the applied voltage. Through the experimental observation, we found that the liftoff velocity could be correlated well with the applied voltage and frequency in the linearly increasing regime. And after having maximum in the liftoff velocity, it was observed that the liftoff velocity decreases with the applied voltage irrespective of AC frequencies. To visualize the change of flame structure with electric fields, planar laser induced fluorescence technique was adopted, and the enhancement of flame stability has been explained based on the flame structural change in electric fields.

  • PDF

Development of a Three-Dimensional DNS Code for Study of Clean Agents -Two-Dimensional Simulation of Diluted Nonpremixed Counterflow Flames-

  • Park, Woe Chul;Hamins, A.
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.18-23
    • /
    • 2002
  • A mixture fraction formulation is used to numerically simulate the structure of diluted axisymmetric methane-air nonpremixed counterflow flames. The effects of global strain rate and gravity wert! investigated and results were compared. Fuel of a mixture of 20% methane and 80% nitrogen by volume and oxidizer of pure air at low and moderate global strain rates $a_g= 20, 40, 80 s^{-1}$ in normal and zero gravity were computed. It is shown that the numerical method is capable of predicting the structure of counterflow flames in normal and microgravity environments at low and moderate global strain rates.

H2/Air 비예혼합화염의 화염신장율에 따른 NO 생성경로의 상세해석 (Detailed Analysis of NO Formation Routes with Strain Rate in H2/Air Nonpremixed Flames)

  • 김종현;황철홍;이창언
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.604-611
    • /
    • 2008
  • Detailed analysis of NO formation routes and its contributions with strain rate in hydrogen/air flames were numerically investigated. LiG detailed reaction mechanism has been used for calculation, which is compared with experimental data in literature. It shows good agreement with experiment for both temperature and NO mole fraction. Three routes have been found important for NO formation in hydrogen flames. These are the Thermal route, NNH route and $N_2O$ route. Strain rate were varied to discuss the $EI_{NO}$ reduction trend in hydrogen nonpremixed flames, which are analyzed by each NO formation routes. As a result, as the strain rate increase, $EI_{NO}$ decrease sharply until strain rate $100s^{-1}$ and decrease slowly until strain rate $310s^{-1}$ again, after that $EI_{NO}$ keeps nearly constant. It can be identified that $EI_{NO}$ trend with the strain rate is well explained by a combination of variation of production rate of above Thermal, NNH and $N_2O$ route. Also result of Thermal-Mech. that includes only thermal NO reaction is compared with those of Full-Mech. As a result, It can be identified that there was difference between the two results of calculation. It is attributed to result that Thermal-mech did not consider contributions of NNH and $N_2O$ route. From these result, we can conclude that NOx emission characteristics of hydrogen nonpremixed flames should consider contributions of above three routes simultaneously.

A Numerical Study on Methane-Air Counterflow Diffusion Flames Part 2. Global Strain Rate

  • Park, Woe Chul
    • International Journal of Safety
    • /
    • 제2권1호
    • /
    • pp.12-16
    • /
    • 2003
  • In Part 1, the flame structure of the counterflow nonpremixed flames computed by using Fire Dynamics Simulator was compared with that of OPPDIF for different concentrations of methane in the fuel stream. In this study, comparisons were made for the global strain rate that is an important parameter for diffusion flames for further evaluation of FDS. At each of the three fuel concentrations, $20% CH_4+ 80% N_2, 50% CH_4 + 50% N_2, 90% CH_4 + 10% N_2$ in the fuel stream, the temperature and axial velocity profiles were investigated for the global strain rate in the range from 20 to $100s^{-1}$. Changes in flame thickness and radius were also compared with OPPDIF. There was good agreement in the temperature and axial velocity profiles between the axisymmetric simulations and the one-dimensional computations except for the regions where the flame temperature reach its peak and the axial velocity rapidly changes. The simulations of the axisymmetric flames with FDS showed that the flame thickness decreases and the flame radius increases with increasing global strain rate.

다수 난류 비예혼합 화염의 상호작용에 관한 연구 (The Stability of Turbulent Interacting Flames)

  • 김진선;이병준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.453-458
    • /
    • 2001
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes which depend on the existence of the center nozzles. Six nozzle arrangements which are cross 4, 5, 8, 9, square 8 and circular 8 nozzles are used for the experiment. Those are arranged to see the effect of the center nozzle out of multi-nozzle. There are many parameters that affect flame stability in multi-nozzle flame such as nozzle separation distance, fuel flowrates and nozzle configuration, but the most important factor is the existence of nozzles in the center area from the nozzle arrangement. As the number of nozzle in the area is reduced, more air can be entrained into the center of flame base and then tag flame is formed. In the case of circular 8 nozzles, blowout flowrates are above 5.4 times compared with that of single equivalent area nozzle.

  • PDF

컵버너시험에서 소화기준에 따른 불활성기체의 소화농도에 대한 정량적 차이 (Quantitative Difference in the Extinguishing Concentration of Inert Gases with Fire Suppression Criteria in a Cup Burner Test)

  • 조재호;황철홍
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.34-42
    • /
    • 2014
  • 본 연구에서는 $CH_4$$C_3H_8$ 연료의 컵버너 비예혼합화염에서 Swing, Rotation, Lifted 및 Blow-out과 같은 화염 불안정성을 발생시키는 불활성기체($N_2$, Ar, $CO_2$ 및 He)의 농도를 측정하였으며, 소화기준(즉, 화염날림 또는 화염불안정성 개시)에 따른 소화농도의 정량적 차이를 검토하였다. 소화농도의 차이는 부상화염의 발생 그리고 낮은 소화성능의 불활성기체일수록 증가됨을 확인하였다. 소화기준에 따른 소화농도의 최대 차이는 $C_3H_8$-air 비예혼합화염의 최대 연료유속의 조건(1.3 cm/s)에서 약 35%이다. 또한 화염 불안정성의 개시를 기준으로 측정된 소화농도는 정확한 그리고 경제적 설계 농도의 관점에서 유용한 정보를 제공할 것으로 기대된다.

동축류 제트에서 초기 온도 변화에 따른 메탄 난류 부상화염 특성 (Characteristics of Methane Turbulent Lifted Flames in Coflow Jets with Initial Temperature Variation)

  • 최병철;정석호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2372-2377
    • /
    • 2007
  • Characteristics of turbulent lifted flames in coflow jets with the varying initial temperature have recently been investigated about only propane case diluted by nitrogen. The investigation has firstly improved a premixed flame model and a large scale mixing model among competing theories on the stabilization mechanism of turbulent flame to be suitable for a high temperature condition. In this research, about methane with good availability to apply for a practical combustor as clean fuel, its characteristics of turbulent nonpremixed flame have been studied experimentally. The results have shown an effectiveness of the premixed flame model and the large scale mixing model considered initial temperature variation. Additionally, considering the axial distance where the mean fuel concentration falls below the stoichiometric level along the center line of the jet according to diluting nitrogen, the premixed flame model have more accurately been improved.

  • PDF

Numerical Modeling of Turbulent Nonpremixed Lifted Flames

  • Kim, Hoojoong;Kim, Yongmo;Ahn, Kook-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제18권1호
    • /
    • pp.167-172
    • /
    • 2004
  • The present study has focused on numerical investigation on the flame structure, flame lift-off and stabilization in the partially premixed turbulent lifted jet flames. Since the lifted jet flames have the partially premixed nature in the flow region between nozzle exit and flame base, level set approach is applied to simulate the partially premixed turbulent lifted jet flames for various fuel jet velocities and co-flow velocities. The flame stabilization mechanism and the flame structure near flame base are presented in detail. The predicted lift-off heights are compared with the measured ones.

동축공기 수소확산화염에서 화염-와류 상호작용 및 혼합 (Flame-Vortex Interaction and Mixing in Turbulent Hydrogen Diffusion Flames with Coaxial Air)

  • 김문기;오정석;최영일;윤영빈
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.149-154
    • /
    • 2007
  • This study examines the effect of acoustic excitation using forced coaxial air on the flame characteristics of turbulent hydrogen nonpremixed flames. A resonance frequency was selected to acoustically excite the coaxial air jet due to its ability to effectively amplify the acoustic amplitude and reduce flame length and NOx emissions. Acoustic excitation causes the flame length to decrease by 15 % and consequently, a 25 % reduction in EINOx is achieved, compared to a flame without acoustic excitation. Moreover, acoustic excitation induces periodical fluctuation of the coaxial air velocity, thus resulting in slight fluctuation of the fuel velocity. From phase-lock PIV and OH PLIF measurement, the local flow properties at the flame surface were investigated under acoustic forcing. During flame-vortex interaction in the near field region, the entrainment velocity and the flame surface area increased locally near the vortex. This increase in flame surface area and entrainment velocity is believed to be a crucial factor in reducing flame length and NOx emission in coaxial jet flames with acoustic excitation. Local flame extinction occurred frequently when subjected to an excessive strain rate, indicating that intense mass transfer of fuel and air occurs radially inward at the flame surface.

  • PDF