• Title/Summary/Keyword: noninvasive

Search Result 685, Processing Time 0.029 seconds

Ultrasonographic and radiographic study on experimental cystitis in rabbit (실험적 방광염 유발 토끼에서의 초음파 및 방사선학적 연구)

  • Sung, Jai-ki;Chang, Dong-woo;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.973-990
    • /
    • 1996
  • To investigate diagnostic imaging of cystitis and to apply it to the small animal practice, ultrasonogram of urinary bladder with moderate distension(4ml/kg) and with complete distension(9ml/kg) to evaluate the irregularity and thickness of bladder, radiography and histopathological examination were performed after experimental cystitis induction. On double contrast cystography, mucosal membrane of the urinary bladder was smooth and thickening urinary bladder wall was not found before cystitis induction. At 3rd day post induction(PI), mucosal irregularity was noted at the cranioventral region of the urinary bladder. Thickening of the urinary bladder wall and filling defect was observed as well. Cystographic findings of 7, 10, 15, 21 day PI were similar to that of 3rd day PI. On ultrasonographic findings of the mural thickness in induction group, it was ascertain that the mural thickness with moderate distention was more thickened than with complete distention at transverse scan. Ultrasonographic findings at longitudinal scan were similar to those of transverse scan. On ultrasonographic findings of mucosal irregularity in induction group, from PI to 7 day PI, mucosal irregularity with moderate distention was more irregular than mucosal irregularity with complete distention. At 10 day PI, there was similarity between moderate distention and complete distention. On histopathologic examination of a section of urinary bladder taken 3 day PI, the mucosal and submucosa were infiltrated by a mixture of thick inflammatory exudate which was composed of neutrophil, plasma protein, bacterial colony and necrotic cells. Congestion, hemorrhage and edema were also observed in the submucosa. At 7th day PI, the mucosal change was similar to that of 3rd day PI, but neovascularization and fibroplasia were observed in the submucosa. At 15th and 21th day PI, mild hyperplasia of mucosal epithelium was observed in the mucosa. Deposition of collagen, neovascularization and severe diffuse infiltration of lymphocyte were observed. These results suggest that ultrasonographic examination with moderate distention is considered to be a more simple, rapid, noninvasive, sensitive and useful diagnostic method than other diagnostic methods for the diagnosis of the cystitis and the differential diagnosis of urinary tract infection.

  • PDF

Effects of Sahyangsohap-won on Cerebral Hemodynamics in Healthy Subjects (사향소합원(麝香蘇合元)이 정상인의 뇌혈류역학에 미치는 영향)

  • Koo, Bon-Soo;Kim, Sung-Hwan;Moon, Sang-Kwan;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup;Ryu, Soon-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.199-205
    • /
    • 2001
  • Background and Purpose : Transcranial doppler ultrasonography(TCD) is a noninvasive and nonradioactive technique for evaluation of the hemodynamics in large cerebral vessels. Sahyangsohap-won(SS) has been considered to be effective for the treatment of various disease, especially cerebrovascular, cardiovascular, and psychosomatoform disorders. But, there is no study about the effect of SS on the cerebral hemodynamics in humans. The aim of this study was to assess the effect of SS on the changes in cerebral hemodynamics and the dose-dependant effect by using TCD. Subjects and Methods : 30 healthy subjects were randomly divided into three group: group 1 took no drug, group 2 took SS one pill, and group 3 took SS 2 pills. Changes in the mean blood flow velocity(MBFV) and pulsatility index(PI) in the middle cerebral artery were evaluated by means of TCD. We obtained hypercapnia with breath-holding and evaluated cerebrovascular reactivity with the breath-holding index(BHI). Systolic blood pressure(SBP), diastolic blood pressure(DBP), and heart rate(HR) were measured by means of ambulatory blood pressure monitoring. In group 2 and group 3, the evaluations were performed during the baseline and were repeated at 20, 40, and 60 minutes after SS administration. In group 1, the evaluation was performed at corresponding time intervals. Results : In mean values of MSFV, PI, SSP, DBP, and HR, no stastically significant differences were found between the 3 groups. However, BHI values were significantly lower in groups 2 and 3 than in group 1 at 40 minutes after SS administration(P<0.05, group 1 vs group 2, group 1 vs group 3 by post-hoc analysis: Scheffe's test) but in dose-dependant effect, there was no difference between group 2 and group 3. Conclusion : These results suggest that SS can decrease vascular resistance in cerebral small arteries or arterioles and enhance their distensibility. Further studies on larger numbers of subjects are needed to confirm these effects and the dose-dependant effects.

  • PDF

Effect of 840 nm Light-Emitting Diode(LED) Irradiation on Monosodium Iodoacetate-Induced Osteoarthritis in Rats (흰쥐의 MIA 유발 무릎 뼈관절염에 대한 840 nm LED의 효과)

  • Jekal, Seung-Joo;Kwon, Pil-Seung;Kim, Jin-Kyung;Lee, Jae-Hyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.151-159
    • /
    • 2014
  • PURPOSE: The purpose of this study was to evaluate whether light-emitting diodes (LED) irradiation could be effective in a noninvasive, therapeutic device for the treatment of osteoarthritis(OA). METHODS: Twenty-four male Sprague-Dawley rats were divided into four groups: Vehicle control (saline); monosodium iodoacetate-injection (MIA); LED irradiation after MIA injection (MIA-LED); indomethacin-treatment after MIA injection (MIA-IMT). OA was induced by intra-articular injection of 3 mg MIA through the patellar ligament of the right knee. Vehicle control rats were injected with an equivalent volume of saline. The LED was irradiated for 15 min/day for a week after 7 days of MIA treatment. To compare with the effect of LED irradiation, the indomethacin was administrated 20 mg/kg twice a week orally after 7 days of MIA treatment. Knee joints were removed and fixed overnight in 10% neutral buffered formalin and decalcified by EDTA for 2 week before being embedded in paraffin. The assessment of OA induction were monitored by knee movement and radiographic finding. Histologic analysis were performed following staining with hematoxylin and eosin, safranin O-fast green, or toluidine blue, picrosirius red, and histologic changes were scored according to a modified Mankin system. Apoptotic cell in tissue sections was detected using TUNEL method. RESULTS: Radiographic examination could not show the differences between the MIA-treated and the MIA-LED-treated rats. In the histologic analysis, however, LED irradiation prevented cartilage damage and subchondral bone destruction, and significantly reduced mononuclear inflammatory cell infiltration and pannus formation. LED irradiation also reduced apoptosis of cartilage cells, but it prevented apoptosis of infiltrated inflammatory cells in synovium. In addition, LED irradiation showed an increase of collagen production in the meniscus. CONCLUSION: These results suggest that the 840 nm LED irradiation would be a suitable non-thermal phototherapy for the treatment of OA, as a cartilage protection and anti-inflammatory modality.

Evaluation of Regional Wall Motion by Phase Analysis of Radionuclide Cardiac Blood Pool Scintigrams in Coronary Artery Disease Patients (관상동맥질환 환자에서 방사성동위원소 위상분석에 의한 심근 국소 운동 평가)

  • Yi, Gang-Wook;Chung, June-Key;Oh, Byeong-Hui;Park, Young-Bae;Lee, Myung-Chul;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.167-174
    • /
    • 1987
  • Among noninvasive approaches for the evaluation of left ventricular performance, radionuclide ventriculography (RVG) has been shown to be of particular values. Phase analysis, recently introduced as more objective means for evaluating the temporal sequence of systolic ventricular wall motion than cine image of RVG comprises a pixel by pixel Fourier transformation of the time activity curve of a multiple gated acquisition equilibrium blood pool study. To examine the regional wall motion of ventricles in myocardial infarctions, we evaluated the phase image and histogram constructed for each ventricle by total phase angle range and full width of half maximum (FWHM). This study consisted of 7 normal subjects and 23 subjects with acute myocardial infarction. Contrast ventriculography and coronary angiography was performed in all partients with myocardial infarction. And we compared the result of phase analysis with cine image of RVG and examined the interrelationship between phase analysis and contrast ventriculography with coronary angiography. The results were as follows; 1) The total phase angle range and FWHM of LV phase histogram in myocardial infarction ($86^{\circ}\;and\;32^{\circ}$, repectively) were wider than those in normal control ($38^{\circ}\;and\;18^{\circ}$, respectively p<0.01). 2) RV phase angle range and FWHM in patients with right coronary artery (RCA) occlusion ($79^{\circ}\;and\;37^{\circ}$, respectively) were wider than those in normal control ($39^{\circ}\;and\;18^{\circ}$, respectively p<0.001) and the patients without RCA occlusion ($52^{\circ}\;and\;19^{\circ}$, respectively p<0.01). 3) Phase analysis was more sensitive (95%) than cine image of RVG (70%) for the detection of regional wall motion abnormality of LV.

  • PDF

Development of Data Acquisition System for Quantification of Autonomic Nervous System Activity and It's Clinical Use (자율신경계의 활성도 측정을 위한 Data Acquisition System의 개발 및 임상응용)

  • Shin, Dong-Gu;Park, Jong-Sun;Kim, Young-Jo;Shim, Bong-Sup;Lee, Sang-Hak;Lee, Jun-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.39-50
    • /
    • 2001
  • Background: Power spectrum analysis method is a powerful noninvasive tool for quantifying autonomic nervous system activity. In this paper, we developed a data acquistion system for estimating the activity of the autonomic nervous system by the analysis of heart rate and respiratory rate variability using power spectrum analysis. Materials and methods: For the detection of QRS peak and measurement of respiratory rate from patient's ECG, we used low-pass filter and impedence method respectively. This system adopt an isolated power for patient's safety. In this system, two output signals can be obtained: R-R interval heart rate) and respiration rate time series. Experimental ranges are 30-240 BPM for ECG and 15-80 BPM for respiration. Results: The system can acquire two signals accurately both in the experimental test using simulator and in real clinical setting. Conclusion: The system developed in this paper is efficient for the acquisition of heart rate and respiration signals. This system will play a role in research area for improving our understanding of the pathophysiologic involvement of the autonomic nervous system in various disease states.

  • PDF

The Usefulness of Capsule Endoscopy in Diagnosis of Small Bowel Diseases (소장질환의 진단에 캡슐내시경 검사의 유용성)

  • Eun, Jong-Ryul;Jang, Byung-Ik
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.45-51
    • /
    • 2006
  • Background: This study was conducted to evaluate the usefulness of capsule endoscopy (CE) for the diagnosis of small bowel diseases. Materials and Methods: We reviewed the medical records of 66 patients (mean age: 52.1 years, male/female: 39/27), who underwent CE at Yeungnam University Hospital from August 2003 to March 2006. Results: Suspicious gastrointestinal (GI) bleeding presenting as anemia or history of gross bleeding was the most common reason to perform CE (71.2%). Other indications included GI symptoms (21.2%) such as abdominal pain/discomfort, nausea, diarrhea, and others (7.6%). In studies performed for GI bleeding (n=47), ulcer/erosion was the most common finding (n=22, 46.8%) followed by tumor (n=5, 10.6%), angiodysplasia (n=3, 6.4%), polyp (n=3, 6.4%), active bleeding (n=1, 2.1 %), ulcer with stenosis (n=1, 2.1%), and normal findings (n=12, 25.5%). Of these, a bleeding focus was detected in 32 cases (68.1%) undergoing CE studies. Among 14 patients with GI symptoms, only two patients had typical findings related with symptoms. Surgical resection was performed in five cases with tumor. Of these, four were diagnosed as gastrointestinal stromal tumor and the other one was a lymphangioma. There were no complications associated with the CE procedure. Conclusion: Capsule endoscopy is a safe, noninvasive diagnostic tool for small bowel diseases and may be useful for the diagnosis of small bowel hemorrhage including obscure bleeding. However, further studies are needed to confirm its utility for abdominal symptoms other than hemorrhage because of the low diagnostic yield.

  • PDF

Acoustic Analysis and Auditory-Perceptual Assessment for Diagnosis of Functional Dysphonia (기능성 음성장애의 진단을 위한 음향학적, 청지각적 평가)

  • Kim, Geun-Hyo;Lee, Yeon-Yoo;Bae, In-Ho;Lee, Jae-Seok;Lee, Chang-Yoon;Park, Hee-June;Lee, Byung-Joo;Kwon, Soon-Bok
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.212-222
    • /
    • 2018
  • Background and Objectives : The purpose of this study was to compare the measured values of acoustic and auditory perceptual assessments between normal and functional dysphonia (FD) groups. Materials and Methods : 102 subjects with FD and 59 normal voice groups were participated in this study. Mid-vowel portion of the sustained vowel /a/ and two sentences of 'Sanchaek' were edited, concatenated, and analyzed by Praat script. And then auditory-perceptual (AP) rating was completed by three listeners. Results : The FD group showed higher acoustic voice quality index version 2.02 and version 3.01 (AVQIv2 and AVQIv3), slope, Hammarberg index (HAM), grade (G) and overall severity (OS), values than normal group. Additionally, smoothed cepstral peak prominence in Praat (PraatCPPS), tilt, low-to high spectral band energies (L/H ratio), long-term average spectrum (LTAS) in FD group were lower than normal voice group. And the correlation among measured values ranged from -0.250 to 0.960. In ROC curve analysis, cutoff values of AVQIv2, AVQIv3, PraatCPPS, slope, tilt, L/H ratio, HAM, and LTAS were 3.270, 2.013, 13.838, -22.286, -9.754, 369.043, 27.912, and 34.523, respectively, and the AUC of each analysis was over .890 in AVQIv2, AVQIv3, and PraatCPPS, over 0.731 in HAM, tilt, and slope, over 0.605 in LTAS and L/H ratio. Conclusions : In conclusion, AVQI and CPPS showed the highest predictive power for distinguishing between normal and FD groups. Acoustic analyses and AP rating as noninvasive examination can reinforce the screening capability of FD and help to establish efficient diagnosis and treatment process plan for FD.

Identification and Validation of Circulating MicroRNA Signatures for Breast Cancer Early Detection Based on Large Scale Tissue-Derived Data

  • Yu, Xiaokang;Liang, Jinsheng;Xu, Jiarui;Li, Xingsong;Xing, Shan;Li, Huilan;Liu, Wanli;Liu, Dongdong;Xu, Jianhua;Huang, Lizhen;Du, Hongli
    • Journal of Breast Cancer
    • /
    • v.21 no.4
    • /
    • pp.363-370
    • /
    • 2018
  • Purpose: Breast cancer is the most commonly occurring cancer among women worldwide, and therefore, improved approaches for its early detection are urgently needed. As microRNAs (miRNAs) are increasingly recognized as critical regulators in tumorigenesis and possess excellent stability in plasma, this study focused on using miRNAs to develop a method for identifying noninvasive biomarkers. Methods: To discover critical candidates, differential expression analysis was performed on tissue-originated miRNA profiles of 409 early breast cancer patients and 87 healthy controls from The Cancer Genome Atlas database. We selected candidates from the differentially expressed miRNAs and then evaluated every possible molecular signature formed by the candidates. The best signature was validated in independent serum samples from 113 early breast cancer patients and 47 healthy controls using reverse transcription quantitative real-time polymerase chain reaction. Results: The miRNA candidates in our method were revealed to be associated with breast cancer according to previous studies and showed potential as useful biomarkers. When validated in independent serum samples, the area under curve of the final miRNA signature (miR-21-3p, miR-21-5p, and miR-99a-5p) was 0.895. Diagnostic sensitivity and specificity were 97.9% and 73.5%, respectively. Conclusion: The present study established a novel and effective method to identify biomarkers for early breast cancer. And the method, is also suitable for other cancer types. Furthermore, a combination of three miRNAs was identified as a prospective biomarker for breast cancer early detection.

Effects of Anticancer Drug Delivery based on Microbubble and Microbubble-Nanoparticle Complex using Low-Intensity Focused Ultrasound in Breast Cancer Animal Model (유방암 동물모델에서의 저강도 집속초음파를 이용한 마이크로버블 및 마이크로버블-나노물질 복합체 기반 항암제 전달 효율 검증)

  • Baek, Hee Gyu;Ha, Shin-Woo;Huh, Hyungkyu;Jung, Byeongjin;Han, Mun;Moon, Hyungwon;Kim, Sangkyun;Lee, Hak Jong;Park, Juyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.39-47
    • /
    • 2019
  • Ultrasound sonication along with microbubble (MB) could enhance drug delivery to promote the absorption of anticancer drugs into cancers in a noninvasive and targeted manners. In this study, we verify the acute drug delivery enhancement (within an hour) of two representative focused ultrasound driven drug delivery enhancement methods (MB and Doxorubicin-coated Nanoparticle complex (MB-NP) based). Experiments were conducted using in vivo mouse model with MDA-MB-231 breast cancer cell line. Ultrasound generated by single-element 1 MHz focused ultrasound transducer was delivered in pulsed sonication consisted of 0.125 msec bursts at a pulse repetition frequency of 2 Hz for 20 seconds without a significant increase in local temperature (less than $0.1^{\circ}C$) or hemorrhage. Doxorubicin concentrations in tumors were improved by 1.97 times in the case of MB-NP, and 1.98 times by using Doxorubicin and MB separately. These results indicate anticancer drug delivery based on MB and MB-NP can significantly improve the effect of anticancer drugs delivered to tumors in a short time period by using low-intensity focused ultrasound.

Establishing EMG Measurement System for Measurement of Motor Nerve Response in Transcranial Magnetic Stimulation (경두개 자기자극 시 운동신경 유발응답 측정을 위한 근전도 측정 시스템 구축)

  • Lee, Geun-Yong;Kim, Su-Hwan;Jo, Jae-Hyun;Yoon, Se-Jin;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.4
    • /
    • pp.413-418
    • /
    • 2019
  • Studies are now actively underway to confirm the degree of treatment and rehabilitation of patients with brain-related diseases (dementia, schizophrenia, depression, Parkinson's disease). Among them, Transcranial magnetic stimulation (TMS) is widely used in treatment because it is a technique that is used for noninvasive brain neuron control in patients with brain disorders. It can be seen that muscle fatigue of normal people increases during Transcranial magnetic stimulation. Therefore, in this paper, our purpose is to build an EMG measurement system to measure motor neuron-induced response during transcranial magnetic stimulation and We identify a motor-neutral response system using tendency in the RMS graph. As an experimental method, the Raw Data received through the surface EMG device and analyzed by RMS technique, after the contraction and relaxation movement of the biceps brachii. As a result of the experiment, we confirmed the trend of rising RMS graph, and it will can be used to determine the self-stimulation intensity for each individual in consideration of the data of the motor-neutral response.