• Title/Summary/Keyword: noninvasive

Search Result 664, Processing Time 0.028 seconds

Frequency domain analysis of the urophonography for LUTS diagnosis (하부요로 폐색 진단을 위한 요류음 주파수 분석)

  • Jeong, Do-Un;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.202-210
    • /
    • 2007
  • The aim of this study is to acquire useful information of lower urinary tract symptom (LUTS) diagnosis through urophonography signal as a noninvasive method. The hardware and software which could evaluate the function of compensatory hypertrophy with noninvasive and comfortable method was implemented to measure uroflow and urophonography signal during urination. The PSD (power spectrum density) and the log-log plot gradient analysis were accomplished in frequency domain. For evaluation of the system and analysis method, a model system for the lower urinary system of men was used. From the evaluation of the model system, the PDS and the log-log plot gradient were dependent on the occlusion degree significantly. In a pilot study on normal and abnormal male subjects, the PSD and the log-log plot gradient were highly correlated with the artificial urethral obstruction.

Undergoing Noninvasive Mechanical Ventilation (비침습적 인공호흡기 적용 환자의 불편감 연구)

  • Shin, Hyun-Ja
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.1
    • /
    • pp.69-80
    • /
    • 2009
  • Purpose: The purpose of this preliminary study was to describe the physical and psychosocial distress of critically ill patients undergoing noninvasive ventilation(NIV). Method: Open-ended question interviews were conducted with four patients using NIV. Considering the outcomes of the interviews, literature, and experts'opinions, a survey questionnaire was developed. Twenty patients in medical and surgical intensive care units answered the questions. Results: Through open-ended question interviews and survey, the patients using NIV reported feeling heavy, impotent feeling, pain, loss in feeling, loss in communication, and lack of sleep as physical distress and a loss in sense of time, pain, anxiety, mind of desiring to die, worry about family, and a sense of burden for medical-cure expenses as psychosocial distress. Conclusion: Critically ill patients undergoing NIV experience physical and psychosocial distress to artificial respiratory ventilation treatment. Further research should be performed with a large sample for generalization of the study result.

  • PDF

Development of ECS-NIBP-$SpO_2$ Patient Monitoring System (ECG-NIBP-$SpO_2$ 환자감시장치 개발)

  • Kim, N.H.;Shin, W.H.;Lee, G.K.;Ra, S.W.;Kim, G.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

Estimation of compensatory hypertrophy in lower urinary system using void force measurement (배뇨력 측정을 통한 하부요로계의 보상성기능항진 평가)

  • Jeong, Do-Un;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.449-456
    • /
    • 2006
  • The purpose of urodynamic investigation is to obtain the information on the function of the urinary system. The aim of this study is to acquire the useful information of lower urinary tract symptom (LUTS) diagnosis through void force signal as noninvasive method. The system which could evaluate the function of compensatory hypertrophy with noninvasive and comfortable method was implemented to measure uroflow and void force during urination. The implemented system composes of the sensor parts, signal conditioning parts and PC monitoring program. For the evaluation of the implemented system, the simulation of control part of the system was performed and the model system for the lower urinary system was designed. The superiority of a measuring characteristic of the implemented system was verified using the model system. From the evaluation of the model system, we have found out that the void force was dependent on the occlusion degree and compensatory hypertrophy significantly.

A Case of Bronchoscopic Treatment of a Bronchopleural Fistula Accompanied by Pneumonia (폐렴에 합병된 기관지 늑막강루에서 기관지 내시경을 이용한 비침습적 치료 -1예 보고)

  • Kim, Hyoungrae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.6
    • /
    • pp.507-510
    • /
    • 2007
  • A bronchopleural fistula (BPF) is traditionally treated by surgery, but currently various noninvasive forms of management, particularly the use of bronchoscopy, have been utilized. The substances and methods for noninvasive management of a BPF differ with individual clinicians. This case describes the use of flexible bronchoscopic treatment of a BPF complicating pneumoniausing embolization coils and intraluminally injected fibrin glue. If the BPF is small and is located on the peripheral bronchus, this minimal invasive maneuver could be recommended for the treatment of a BPF.

Usefulness Assessment of Noninvasive Bladder Pressure Measurement for BPH Diagnosis (전립선 비대증 진단에서의 비침습적 방광내압계측 유용성 평가)

  • Jeong, Do-Un;Chung, Wan-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.865-866
    • /
    • 2006
  • The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfort methods. There for in this study hardware device and computer software have been developed that enables the analysis of the urine flow rate and vesical pressure signal measured during voiding. These signals were recorded simultaneously and transmitted to the PC. For the measurement system evaluation, the model system for the lower urinary system of men was designed. From the evaluation of the model system, vesical pressure was correlated with the occlusion degree. In a pilot study on 5 male subjects, means of standard deviation was 1.06, average error rate was 2.09 and coefficient variation was 2.09.

  • PDF

Measurement of Noninvasive Mean Arterial Pressure using Tonometry Pressure Sensor (압력센서 가압방식의 평균혈압 측정에 관한 연구)

  • Park, Mi-Kyoung;Huh, Young;Kang, Hee-Jung;Kim, Kyoung-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.859-860
    • /
    • 2006
  • We developed a cuffless and noninvasive measurement technique of blood pressure using tonometric pressure sensor. With observation that the maximum value of pulse pressure is not obtained at mean arterial pressure(MAP), we have figured out MAP based on the physiological characteristic including the elasticity of wrist tisse. Detecting only one part of the body and using only one device are quite advantageous over other BP measurement techniques. Our technique makes new way for the cuffless BP measurement.

  • PDF

Noninvasive Monitoring of ion Energy Distribution in Plasma Etching (플라즈마 식각 공정 시 비 침투적 방법으로 이온에너지 분포 측정 연구)

  • Oh, Se-Jin;Chung, Chin-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2069-2071
    • /
    • 2005
  • 본 연구에서는 플라즈마 식각 공정 시 식자률, 선택비, wafer 손상등과 중요한 관련이 있는 이온 에너지 분포(IED)를 측정하기 위해서 챔버 내에 직접적으로 분석기를 설치하지 않고 챔버 외부에서 비 침투적(noninvasive)인 방법을 사용하여 측정하였다. 이 방범은 신호선 중 한 곳에 측정 점을 잡기 위한 연결 장치만 필요하며 그곳에서의 전안 신호와 전류 신호를 오실로스코프에서 측정한 후 미리 얻어진 챔버 구조 모델링 계수 등을 통해 실제 바이어스 전극에 걸리는 전압 및 전극에서 플라즈마로 흐르는 전류를 유추한다. 전압 및 전류측정값과 power balance와 particle balance를 적용하여 얻은 플라즈마 특성 상태 변수들을 사용하여 oscillating step sheath model을 기반으로 한 분석 프로그램을 통해 실시간 이온에너지 분포 결과를 얻었다. 실제 공정 시 바이어스 주파수 변화, 바이어스 파워 변화, 소스 파워변화 조건 등에 따른 이온 에너지 분포 측정 및 분석을 통해 비 침투적측정방법 적용의 가능성과 장점을 확인하였다.

  • PDF

Clinical Experiences on the Effect of Scrambler Therapy for Patients with Postherpetic Neuralgia

  • Ko, Young Kwon;Lee, Ho Young;Lee, Wang Yong
    • The Korean Journal of Pain
    • /
    • v.26 no.1
    • /
    • pp.98-101
    • /
    • 2013
  • Postherpetic neuralgia (PHN) is a debilitating complication of herpes zoster, especially in elderly and comorbid patients. Unfortunately, the currently available treatments have shown limited efficacy and some adverse events that are poorly tolerated in elderly patients. Scrambler Therapy, proposed as an alternative treatment for chronic neuropathic pain recently, is a noninvasive approach to relieve pain by changing pain perception at the brain level. Here, we report our clinical experiences on the effect of Scrambler Therapy for three patients with PHN refractory to conventional treatment.

Determination of Total Hemoglobin in Whole Blood by Spectroscopy (분광학적 방법을 이용한 전혈내의 총 혈색소량 결정)

  • Kim, Y.J.;Yoon, G.;Kim, W.K.;Kim, J.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.251-253
    • /
    • 1996
  • Noninvasive monitoring of total Hemoglobin value is feasible with the use of spectroscopic measurements. As a step toward tile final goal of the development of a noninvasive monitor, the spectra$(400{\sim}800mm)$of EDTA whole blood were obtained along with reference total Hemoglobin values. Under the same condition water spectrum was generated. It was subtracted from each blood sample, and then tile first derivative of each subtracted data was taken by 'approximated first derivative algorithm' with gap (1,6,10,20nm). The correlation was obtained between total Hemoglobin and first valley wavelength of first derivative spectrum (sample number: 93).

  • PDF