• Title/Summary/Keyword: non-invasive method

Search Result 456, Processing Time 0.029 seconds

A Review on Impedance Cardiography and Its Oriental Medical Application (한의학적 활용을 위한 임피던스 심장기록법의 연구동향)

  • Ko, Young-Il;Lee, Hyon-Soo;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.67-78
    • /
    • 2006
  • Objectives : To review the method, validity and reliability of Impedance Cardiography and to study its oriental medical application. Method : The papers reviewed in this study were searched through internet search engines such as Springer, Science Direct, and China National Knowledge Infrastructure. Conclusion : In this study, the methodological limitations, validity and reliability of impedance cardiography were examined. Impedance Cardiography is recognized as a highly accurate non-invasive tool to assess hemodynamic parameters. The ability of impedance cardiography to assess hemodynamic parameters in non-invasive way is very suitable for researches on the effect of oriental medical therapeutics or the validation of oriental medical diagnostic.

  • PDF

Minimally Invasive Excision of Epidermal Cysts through a Small Hole Made by a $CO_2$ Laser

  • Song, Seung Wook;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • v.41 no.1
    • /
    • pp.85-88
    • /
    • 2014
  • To improve the cosmetic results of removing epidermal cysts, minimally invasive methods have been proposed. We proposed a new minimally invasive method that completely removes a cyst through a small hole made by a $CO_2$ laser. Twenty-five patients with epidermal cysts, which were 0.5 to 1.5 cm in diameter, non-inflamed, and freely movable, were treated. All of the patients were satisfied with the cosmetic results. This method is simple and results in minimal scarring and low recurrence rates without complications.

Comparison of the non-invasive diagnostic methods, stool antigen test and PCR assay, for Helicobacter felis detection in dogs

  • Hong, Sunhwa;Lee, Hak-Yong;Kim, Tae-Wan;Kim, Okjin
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • The aim of the present study was to compare the non-invasive methods for the diagnosis of H. felis with HpSA kit-based detection method and H. felis-specific PCR assay with dog's stool samples without sacrifice. Male Beagle dogs (n=6) were infected with H. felis ATCC 49179 ($1.0{\times}10^9CFU/dog$) by intra-gastric inoculation two times at 3-day intervals, and the stool specimens of dogs were collected 1, 3, 5, 7, 14, 21 days after infection to submit to HpSA test and H. felis-specific PCR. As the results, the sensitivity of the HpSA and the PCR analysis was 50.0%, 83.3% respectively. Although HpSA test is less sensitive, it could be used for rapid, cheap and easy screening assay for H. felis infection in dog and cats. We suggest that the H. pylori stool antigen kit, HpSA, is useful and effective for monitoring H. felis infection. If HpSA test would be made with H. felis antibodies in the future, its sensitivity could be increased. Also, PCR assay could be successfully used to detect the H. felis in stools. Applying the H. pylori stool antigen kit and PCR assay may be the recommended non-invasive strategy to identify H. felis in dog and cats.

Non-invasive Blood Glucose Detection Sensor System Based on Near-Infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 검출 센서 시스템)

  • Kang, Young-Man;Han, Soon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.991-1000
    • /
    • 2021
  • Among non-invasive blood glucose detection technologies, the optical technique is a method that uses light reflection, absorption, and scattering characteristics when passing through a biological medium. It reduces pain or discomfort in measurement and has no risk of infection. So it is becoming a major flow of blood glucose detection research. Among them, near-infrared spectroscopy has a disadvantage in that the complexity increases when analyzing signals detected due to interferences between proteins and acids that share a similar absorption function with blood glucose molecules. In this study, a non-invasive sensor system with multiple near-infrared bands was designed and manufactured to alleviate the deterioration of blood glucose detection function that may occur due to skin absorption of near-infrared rays. A blood survey was conducted to verify the system, and the degree of blood glucose response in the blood was collected as spectral data, and the results of this study were quantitatively verified in terms of correlation between the data and blood glucose.

Blood Pressure Measurement using the Modified Step-wise Deflation Method (개선된 계단 배기 방법을 이용한 혈압 측정)

  • Oh, Hong-Sic;Lee, Jong-Shill;Chee, Young-Joon;Kim, In-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.351-358
    • /
    • 2010
  • In the automatic non-invasive blood pressure measurement device, the oscillometric method iswidely used. In the oscillometric method, the step-wise deflation has the advantage of the robustness for the motion artifacts than the linear deflation method. But it has the disadvantage of its longer measurement time because we need to detect two or more pulses in a certain cuff pressure step. In this study, we suggest the modified step-wise deflation method to overcome this limitation while maintaining the general concept of step-wise deflation. Using one valid pulse in each step and the deflating valve control during the diastolic period, the measurement time could be reduced. In order to verify the accuracy of the proposed algorithm, we compared the blood pressure values from the suggested method and the blood pressure values from the conventional auscultation method. The mean and standard deviation were -0.50${\pm}$5.3mmHg and 2.08${\pm}$4.75mmHg, for systolic and diastolic blood pressure respectively. The measurement time can be reduced up to the half of conventional step-wise deflation method.

A Study on Implemetation of Non-invasive Blood Pressure (비침습적 혈압 측정 시스템 구현에 관한 연구)

  • 노영아;이종수;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.451-454
    • /
    • 2000
  • Invasive methode and Non-invasive methode are used in blood pressure measurement. The Invasive methode can Set the correct measured blood pressure but, it has patient feels uncomfortable. So most of cases use Non-invasive methode. The Oscillometric method is commonly apply to modem electric sphygmomanometer and using various algorithm. In this paper describe about a algorithm it control and to determinate the cuff pressure, and filtering that data for measure the blood pressure. The communicating with personal computer can pressure deflation is by Solenoid valve and it uses RS-232 system in packet communication. The main using algorithm for blood pressure measurements are maximum amplitude algorithm and oscillometric algorithm. MAA(maximum amplitude algorithm) has various measured oscillation it depend on patient's age, height, weight and arm circumference size. In this paper, 1 studied the various measured oscillation apply to characteristic ratio and can get the result of systolic blood pressure, diastolic blood pressure, mean blood pressure. It was not used same ratio to measuring oscillation. In the MAA(maximum amplitude algorithm), we hope for reduce the difference with the real blood pressure and the measured blood pressure, when it applied with various specific ratio.

  • PDF

Implementation of Noninvasive Blood Pressure Measuring System for Home Health Care Using Oscillometric Method (오실로메트릭법을 적용한 홈헬스케어용 비침습적 혈압측정법의 구현)

  • Kang Seong-Chul;Jeon Gye-Rock;Jeong Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.689-692
    • /
    • 2006
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed to reduce errors and weaknesses of the existing invasive blood pressure measurement methods. The system is composed of pressure control, signal measurement and blood pressure signal processing units. To verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

The Effect of Non-Invasive Sobu(H8) Point Stimulus by 'DONG CHU CHIM' on HRV (동추침(東樞鍼)에 의한 비침습적 소부혈(少府穴) 자극이 심박변이도에 미치는 영향)

  • Jung, Dae-Sun;Han, Chang-Hyun;Park, Soo-Jin;Kwon, Young-Kyu
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.1 s.19
    • /
    • pp.129-138
    • /
    • 2007
  • Background : Recently a discussion about Qi including a study about the effect or the theory of acupuncture is getting prevailing in various angles. In most of studies about acupuncture stimulus, 'Filiform acupuncture'(毫鍼) is used. A study about Nine kinds of acupuncture(九鍼), except 'Filiform acupuncture'(毫鍼) has not been reported yet, and there is no study about using a special acupuncture made for controling Qi either. Objectives : 'DONG CHU CHIM' can be used for patients who are scared of a pain because it is a medical Qikong tool and non-invasive stimulus one. To assess a effect of Qikong operation using 'DONG CHU CHIM' objectively, we stimulated non-invasive to Sobu point of 30 normal adults using 'DONG CHU CHIM' and examined the result in the basis of high confirmed and repetitive HRV which is a functional assessment method of the autonomic nervous system. Method : This study has been proceeded in three periods. Total was 35min : 10min for the former and latter period of acupuncture stimulus, l5min for the acupuncture stimulus period. For each period, we measured 5min of 3 times(Stage I, II, III). Result : Comparing the changes of HRV during pre-stimulation and post-stimulation, HRT was significantly reduced, LOGTP, LOGVLF, LOGLF, LF/HF were significantly increased and SDNN, LOGHF were generally increased but did not show any significant changes. So we think that the stimulus of 'DONG CHU CHIM' affects on the sympathetic system and parasympathetic system, it activates the autonomic nervous system, and it makes the inequality of the sympathetic and parasympathetic nerve to be equal status. Conclusions : We can conclude that the non-invasive stimulus of 'DONG CHU CHIM' can affect significantly to the autonomic nervous system. So it can be used in clinic as a tool of Qikong operation, and it can be also used to weak patients or children because it doesn't give a lot of pain like 'Filiform acupuncture'(毫鍼) compared to invasive stimulus. By the basis of this study, more studies about the effect of 'DONG CHE CHIM' should be done in the future.

  • PDF

Clinical Characteristics of Cervical and Thoracic Radiculopathies: Non-Invasive Interventional Therapy (목 및 가슴신경뿌리병증의 임상적 고찰: 비침습적 중재시술치료)

  • Roh, Hakjae;Lee, Sang-Heon;Kim, Byung-Jo
    • Annals of Clinical Neurophysiology
    • /
    • v.10 no.2
    • /
    • pp.83-97
    • /
    • 2008
  • Cervical and thoracic radiculopathies are among the most common causes of neck pain. The most common causes are cervical disc herniation and cervical spondylosis in patients with cervical radiculopathy, and diabetes mellitus and thoracic disc herniation in thoracic radiculopathy. A thorough history, physical examination, and testing that includes electrodiagnostic examination and imaging studies may distinguish radiculopathy from other pain sources. Although various electrodiagnostic examinations may help evaluate radiculopathy, needle electromyography is the most important, sensitive, and specific method. Outcome studies of conservative treatments have shown varying results and have not been well controlled or systematic. When legitimate incapacitating symptoms continue despite conservative treatment attempts, more invasive spinal procedures and intradiscal treatment may be appropriate. Surgery has been shown to have excellent clinical outcomes in patients with disc extrusion and neurological deficits. However, patients with minimal disc herniation have fair or poor surgical outcomes. In addition, conventional open disc surgery entails various inadvertent surgical related risks. Although there has not yet been a non-surgical interventional procedure developed with the therapeutic efficacy of open surgery, conservative procedures can offer substantial benefits, are less invasive, and avoid surgical complications. While more invasive procedures may be appropriate when conservative treatment fails, prospective studies evaluating cervical and thoracic radiculopathies treatment options would help guide practitioners toward optimally cost-effective patient evaluation and care.

  • PDF

Species and Sex Identification of the Korean Goral (Nemorhaedus caudatus) by Molecular Analysis of Non-invasive Samples

  • Kim, Baek Jun;Lee, Yun-Sun;An, Jung-hwa;Park, Han-Chan;Okumura, Hideo;Lee, Hang;Min, Mi-Sook
    • Molecules and Cells
    • /
    • v.26 no.3
    • /
    • pp.314-318
    • /
    • 2008
  • Korean long-tailed goral (Nemorhaedus caudatus) is one of the most endangered species in South Korea. However, detailed species distribution and sex ratio data on the elusive goral are still lacking due to difficulty of identification of the species and sex in the field. The primary aim of this study was to develop an economical PCR-RFLP method to identify species using invasive or non-invasive samples from five Korean ungulates: goral (N. caudatus), roe deer (Capreolus pygargus), feral goat (Capra hircus), water deer (Hydropotes inermis) and musk deer (Moschus moschiferus). The secondary aim was to find more efficient molecular sexing techniques that may be applied to invasive or non-invasive samples of ungulate species. We successfully utilized PCR-RFLP of partial mitochondrial cytochrome b gene (376 bp) for species identification, and sex-specific amplification of ZFX/Y and AMELX/Y genes for sexing. Three species (goral, goat and water deer) showed distinctive band patterns by using three restriction enzymes (Xbal, Stul or Sspl). Three different sexing primer sets (LGL331/335 for ZFX/Y gene; SE47/48 or SE47/53 for AMELX/Y gene) produced sex-specific band patterns in goral, goat and roe deer. Our results suggest that the molecular analyses of non-invasive samples might provide us with potential tools for the further genetic and ecological study of Korean goral and related species.