• 제목/요약/키워드: non-detection zone

검색결과 50건 처리시간 0.028초

PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법 (A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System)

  • 강성욱;김경화
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

단독운전 방지를 위한 능동적 주파수 변환 기법의 검출 성능 및 THD 분석 (Detection Performance and THD Analysis of Active Frequency Drift for Anti-Islanding)

  • 조영민;최주엽;송승호;최익;이영권
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.11-19
    • /
    • 2015
  • Islanding is a phenomenon that EPS(Electric Power System) is continuously energized by PV PCS(Photovoltaic Power Conditioning System) even when EPS is isolated from the grid. Unintentional islanding will result in safety hazard, power quality degradation and many other issues. So, islanding protection of grid-connected PV PCS is a key function for standards compliance. Nowadays, many anti-islanding schemes are researched. But existing anti-islanding schemes used in PV PCS have power quality degradation and non-detection zone issues. This paper analyses not only detection performance of existed anti-islanding schemes using active frequency drift but also THD of PCS output current according to each value disturbance for anti-islanding. In addition, the lowest value of disturbance in each scheme was tabulated under guarantee of anti-islanding condition.

폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구 (A study for detection of melt flow zone about polyethylene butt fusion joints)

  • 길성희;김영구;조영도;이연재
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.103-109
    • /
    • 2016
  • 폴리에틸렌(Polyethylene) 배관은 가요성이 좋고 부식이 되지 않는 등의 장점으로 가스배관 뿐만 아니라 원자력 발전소의 배수관, 석유화학 및 정유사 공정배관 등으로 그 사용범위가 점차 확대되고 있다. 그러나 폴리에틸렌 배관의 연결부를 직접적으로 검사할 수 있는 검사방법이 개발되지 않아서 사용범위를 확대하는데 제한을 받고 있다. 폴리에틸렌 배관의 연결방법은 전기융착 방법과 버트융착 방법으로 구분할 수 있는데 이 중에서 가장 많이 사용하는 방법은 버트융착이다. 버트융착은 배관과 배관을 열판에 맞닿게 하고 일정한 온도 및 압력을 가한 후 열판을 제거하고 용융된 배관의 말단부를 서로 연결하는 방법으로서 별도의 연결구가 필요하지 않아 가장 많이 사용하고 있는 연결방법이다. 버트융착 시에 열판으로부터 열이 용융된 후 압력을 가하면 용융부는 비드를 형성하는 부분과 연결부를 형성하는 부분으로 분리되고 냉각과정을 거쳐 버트융착부가 된다. 본 연구는 연결부를 형성하는 부분에서 열판으로부터 열이 전파되어 용융된 거리를 측정하고 이 결과를 연결부에 대한 건전성 평가 방법 중의 하나로 제시하고자 한다. 외경 225mm, 두께 20.5mm의 중밀도 폴리에틸렌 가스용 1호관의 초음파 속도를 측정한 결과 2,200m/s 였다. 열용융 거리를 측정하기 위하여 열판으로부터 열이 전파되어 폴리에틸렌을 가열하는 시간을 0%~130%까지 변화시켜 시험편을 제작하였다. 또한 정상적인 가열시간(100%의 가열)을 제공하고 스크레핑 처리를 하지 않은 시험편과 토양을 삽입한 시험편 그리고 자갈을 삽입한 시험편과 비닐류를 삽입한 시험편을 제작하였다. 총 20개의 시험편에 대한 열용융 거리를 측정하기 위하여 3.5MHz 및 5.0MHz 센서를 이용하였으며 1개의 시험편에 대하여 총 3곳에서 초음파 탐상을 실시하였다. 열용융 신호를 명확하게 구분하기 위하여 모든 탐상 결과에 대하여 동일한 post image processing을 수행하였고 이미지 레벨, contrast, sharpen 및 threshold를 적용하였으며 결과 탐상은 가장 직관적으로 파악할 수 있는 gray scale로 표현하였다. 탐상 결과 가열시간이 짧은 시험편일수록 융착이 이루어지지 않아 멀티플 에코가 반사되는 영역이 증가하였으며 이 부분을 최대한 배제할 수 있는 위치에서 데이터를 획득하였다. 정상적인 가열시간의 80%인 168초의 시간을 가한 시험편부터 열용융 거리에 대한 반사신호가 뚜렷이 구분되었으며 이 시험편부터 거리 측정을 실시하였다. 가열시간이 정상가열시간의 7%인 15초의 가열시간을 가한 시험편부터 더 낮은 가열시간을 가한 시험편의 경우 융착이 이루어지지 않아서 3곳 모두 데이터 영상을 획득할 수 없었다. 위 실험 결과로 위상배열초음파를 통해 폴리에틸렌 배관 버트융착부에서 열이 용융되어 전파된 거리 측정이 가능함을 확인하였으며 또한 열이 용융되어 전파된 거리 측정을 통해 정상적인 융착과 불완전 융착을 구분할 수 있음을 확인할 수 있었다.

Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선 (Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement)

  • 김동욱;김성민
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.539-547
    • /
    • 2018
  • 계통 연계형 인버터는 단독운전 조건에서 반드시 전력 공급을 차단해야 한다. 이러한 이유로 분산 발전 시스템은 단독운전을 검출 기능을 반드시 가지고 있어야 한다. 분산 발전용 인버터에 적용되는 일반적인 방법 중에는 Slip-Mode frequency Shift (SMS) 단독운전 검출 기법이 있다. SMS 기법은 계통 전압의 주파수에 따라 무효 전력을 공급하여 단독운전 조건에서 계통 주파수를 허용 범위 밖으로 이동시키는 방법이다. SMS 기법은 안정적으로 단독운전을 검출할 수 있으며, 계통 전류에 고주파를 인가하지 않는다는 장점이 있으나, 무효 전류를 인가하기 때문에 계통 역률이 나빠져서 전력 품질의 저하를 가져온다. 본 논문에서는 계통 전원이 연결되어 있는 정상 조건에서 전력 품질 저하가 없는 수정된 SMS 기법을 제안한다. 600W 단상 인버터 실험을 통해 제안된 방법의 유효성을 검증한다.

Detection of High-Risk Human Papillomaviruses in the Prevention of Cervical Cancer in India

  • Baskaran, Krishnan;Kumar, P Kranthi;Karunanithi, Santha;Sethupathy, Subramanian;Thamaraiselvi, B;Swaruparani, S
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8187-8190
    • /
    • 2016
  • Human papillomaviruses (HPVs) are small, non-enveloped, double-stranded DNA viruses that infect epithelial tissues. Specific genotypes of human papillomavirus are the single most common etiological agents of cervical intraepithelial lesions and cervical cancer. Cervical cancer usually arises at squamous metaplastic epithelium of transformation zone (TZ) of the cervix featuring infection with one or more oncogenic or high-risk HPV (HR-HPV) types. A hospital-based study in a rural set up was carried out to understand the association of HR-HPV with squamous intraepithelial lesions (SILs) and cervical cancer. In the present study, HR-HPV was detected in 65.7% of low-grade squamous intraepithelial lesions (LSILs), 84.6% of high-grade squamous intraepithelial lesions (HSILs) and 94% of cervical cancer as compared to 10.7% of controls. The association of HPV infection with SIL and cervical cancer was analyzed with Chi square test (p<0.001). The significant association found confirmed that detection of HR-HPV is a suitable candidate for early identification of cervical precancerous lesions and in the prevention of cervical cancer in India.

간접전류제어 기반의 계통연계형 인버터를 위한 단독운전방지 기법 (Anti-islanding Method for Indirect Current Control based Utility Interactive Inverter)

  • 오형민;김영우;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.207-208
    • /
    • 2011
  • 중요부하를 갖는 계통연계 인버터에서 계통이상시 독립운전으로 전환하여 중요부하에 지속적인 전력을 공급하여야 한다. 기존의 제어 방식은 독립운전시 전압제어를 계통연계시 전류제어를 하기 때문에 모드전환시 과도상태가 발생하고 단독운전 검출전에도 부하의 전압과 주파수가 변동하여 중요부하에 심각한 영향을 줄 수 있다. 본 논문에서는 모드 전환시 과도상태를 최소화하면서 단독운전 검출전에도 부하 전압과 주파수가 일정하게 유지하는 간접전류제어 기반의 계통연계 인버터에서 전압 고조파를 주입함으로써 NDZ(Non-Detection Zone)를 갖지 않는 단독운전방지 기법을 제안한다.

  • PDF

슬립모드 방식을 이용한 단독운전 검출기법의 모델링과 평가 (Modeling and Evaluation of Slip-Mode Frequency Shift Method for Anti-islanding Method)

  • 유병규;정영석;소정훈;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.520-522
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift (SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection zone (NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through the modeling and verified visually by simulation and experiment.

  • PDF

정밀한 불검출영역 해석을 통한 분산전원 시스템의 새로운 단독운전 방지기법 (A Novel Anti-Islanding Scheme for Distributed Generation System via accurate Analysis of NDZ)

  • 조영민;구본하;최익;송승호;최주엽;이영권;조상윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.121-122
    • /
    • 2015
  • 본 논문에서는 기존의 불검출영역(Non Detection Zone; NDZ) 해석보다 수식적으로 더욱 정밀하게 NDZ를 분석한다. 또한, 이런 NDZ를 벗어나게 하는 최소 이득의 Positive-feedback loop를 가지는 새로운 단독운전 방지기법을 설계하고, 이를 시뮬레이션과 실험을 통해 단독운전 검출 성능을 검증하고 제안하는 기법이 전력품질에 끼치는 영향을 분석한다.

  • PDF

변화탐지를 위한 인공위성영상자료의 정밀보정에 관한 연구 (A Study on Precision Rectification Technique of Multi-scale Satellite Images Data for Change Detection)

  • 윤희천;이성순
    • 한국측량학회지
    • /
    • 제22권1호
    • /
    • pp.81-90
    • /
    • 2004
  • 인공위성 영상자료들은 촬영조건 및 센서의 특성에 따라 다른 기하학적인 왜곡을 포함하고 있을 뿐만 아니라 공간, 방사 및 분광 해상도가 상이하기 때문에 정밀한 분석 결과 산출에 어려움이 있다. 즉, 두 개 이상의 영상을 비교 분석하기 위해 기본적인 센서 정보의 차이에서 발생하는 정오차를 소거하고 지형기복에 의해 발생하는 부정오차를 제거하기 위한 정밀 기하보정은 반드시 선행되어야 한다. 본 연구에서는 인공지형지물 변화탐지 기본도 를 구축하기 위해 위성의 센서정보를 이용한 센서모델링을 실시하였고 지상기준점과DEM자료를 가지고 정밀편위수정함으로써 다른 센서 및 촬영조건에 따라 발생하는 정오차를 소거하였다. 즉, 정밀편위수정법에 의해 Kompsat EOC 영상의 기복변위량을 감소시킬 수 있었고, 변화탐지를 위해 사용된 영상의 정합성과를 도심지역, 산림지역 및 혼합지역으로 나누어 시험 지역을 선정하여 검토한 결과 모든 지역에서 약 10% 정도의 정합률이 향상됨으로써 영상의 위치정확도를 향상시킬 수 있었다. 이러한 기본도를 가지고 이루어지는 변화탐지 결과는 지형지물의 갱신이나 다양한 GIS 응용의 기본 자료로서 효율적으로 사용할 수 있을 것으로 기대된다.

계통연계형 태양광발전시스템의 AFS 기법을 이용한 단독운전 방지 (Anti-islanding using Active Frequency Shake Method for Grid-connected PV Generation System)

  • 옥승규;강문성;양오
    • 한국정보통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.127-136
    • /
    • 2013
  • 계통연계형 인버터의 중요 성능 중 단독운전 검출기능 및 방지기능은 계통을 유지보수하기 위한 작업자의 안전을 위하여 고려되어야 할 필수 사항이다. 본 논문에서는 태양광을 이용한 계통연계형 태양광발전시스템에서의 AFS(Active Frequency Shake) 단독운전 검출기법을 제안하고자 한다. 먼저 AFS 단독운전 검출 알고리즘을 제안하기 위하여 기존의 능동 주파수 변이기법 알고리즘에 대해 기술한다. 그리고 단독운전 불검출영역을 줄이고, THD(Total Harmonic Distortion)를 개선하며, 기존 알고리즘 보다 검출 속도 또한 향상 시킬 수 있는 알고리즘을 제시하였다. 아울러 제안된 단독운전방지 기법을 3kW 계통연계형 태양광 인버터에 적용하고 시뮬레이션 및 실험을 통하여 제안하는 알고리즘의 타당성을 검증하였다.