• Title/Summary/Keyword: non-contacting

Search Result 146, Processing Time 0.019 seconds

Human Safety Assessment for a 4 × 8 Array Antenna Used for Wireless Power Transfer at 2.4 GHz (2.4 GHz의 무선전력전송에 사용되는 4 × 8 배열 안테나에 대한 인체안전성평가)

  • Ju, Young Jun;Kim, Jun Hee;Lee, Yu-ri;Gimm, Yoon-Myoung;Lim, Yong Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.338-341
    • /
    • 2018
  • Wireless Power Transfer(WPT) of array antenna applied to beam-forming techniques enables highly efficient WPT when transmitters and receivers are not contacting and even when they are separated. However, this WPT method is possible to use only when human safety restriction by distance between the transmitters and the receivers is satisfied. In the paper, a $4{\times}8$ array antenna for 2.4 GHz is modeled by simulation, then electric field intensity and 10 gram average head SAR(Specific Absorption Rate) by distance away from the array antenna inputted 1 W of 2.4 GHz sinusoidal wave at each single antenna of the array antenna for 2.4 GHz were obtained. And they were compared with human safety restriction of draft of 2018 ICNIRP(International Commission on Non-Ionizing Radiation Protection) guidelines. As the result, power density of far field derived from the electric field intensity was $33.257W/m^2$, which satisfied with occupational human safety restriction but exceeded public's. In addition, the 10 gram average head SAR exceeded the human safety restriction.

  • PDF

Back Surface Field Properties with Different Surface Conditions for Crystalline Silicon Solar Cells (후면 형상에 따른 결정질 실리콘 태양전지의 후면전계 형성 및 특성)

  • Kim, Hyun-Ho;Kim, Seong-Tak;Park, Sung-Eun;Song, Joo-Yong;Kim, Young-Do;Tark, Sung-Ju;Kwon, Soon-Woo;Yoon, Se-Wang;Son, Chang-Sik;Kim, Dong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.21 no.5
    • /
    • pp.243-249
    • /
    • 2011
  • To reduce manufacturing costs of crystalline silicon solar cells, silicon wafers have become thinner. In relation to this, the properties of the aluminium-back surface field (Al-BSF) are considered an important factor in solar cell performance. Generally, screen-printing and a rapid thermal process (RTP) are utilized together to form the Al-BSF. This study evaluates Al-BSF formation on a (111) textured back surface compared with a (100) flat back surface with variation of ramp up rates from 18 to $89^{\circ}C$/s for the RTP annealing conditions. To make different back surface morphologies, one side texturing using a silicon nitride film and double side texturing were carried out. After aluminium screen-printing, Al-BSF formed according to the RTP annealing conditions. A metal etching process in hydrochloric acid solution was carried out to assess the quality of Al-BSF. Saturation currents were calculated by using quasi-steady-state photoconductance. The surface morphologies observed by scanning electron microscopy and a non-contacting optical profiler. Also, sheet resistances and bulk carrier concentration were measured by a 4-point probe and hall measurement system. From the results, a faster ramp up during Al-BSF formation yielded better quality than a slower ramp up process due to temperature uniformity of silicon and the aluminium surface. Also, in the Al-BSF formation process, the (111) textured back surface is significantly affected by the ramp up rates compared with the (100) flat back surface.

Numerical Fluid Dynamic Study for Improvement of Mixing Efficiency in the Contactor (접촉 반응조 혼합효율 향상을 위한 전산 유체역학적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Joh, Jing-Young;Choi, Jun-Ho;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.8
    • /
    • pp.860-865
    • /
    • 2006
  • The characteristics of flow field and turbulent mixing efficiency of SS in non-aerated contacting reactor are critical design parameters directly affecting on the efficiency of the overall process of wastewater treatment system. To this end, in this study numerical fluid dynamic calculation has been made to investigate the flow field and concentration distribution of SS in terms of specification(shape and dimension) of impeller and other operating conditions. As the first step, the performance of the computer program developed was successfully evaluated by the comparison of the typical flow field with the type of impeller with that appeared in open literature. Further, a series of parametric investigations are made in terms of interesting parameters such as the type and dimension of impeller, location, and number of impeller, etc. A number of useful conclusions obtained by numerical calculation are the superiority of mixing efficiency of pitched type than the flat one together with the visible increase of the overall mixing effect by the employment of the larger impeller and increase of the impeller number, etc.

The Effect of Graphene on the Electrical Properties of a Stretchable Carbon Electrode (그래핀 첨가에 따른 신축성 카본전극의 전기적 특성 변화)

  • Lee, T.W.;Park, H.H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.77-82
    • /
    • 2014
  • Stretchable electrodes are focused due to many demands for soft electronics. One of the candidates, carbon black composites have advantages of low cost, easy processing and decreasing resistivity in a certain range during stretching. However, the electrical conductivity of carbon black composites is not enough for electronic devices. Graphene is 2-dimensional nanostructured carbon based material which shows good electrical properties and flexibility. They may help to improve electrical conductivity of the carbon black composites. In this study, graphene was added to a carbon black electrode to enhance electrical properties and investigated. Electrical resistivity of graphene added carbon electrode decreased comparing with that of carbon black electrode because graphene bridged non-contacting carbon black aggregates to strengthen the conductive network. Also graphene reduced an increase in the resistance of the carbon black electrode applied to strain because they connected gap of separated carbon black aggregates and aligned along the stretching direction at the same time. In conclusion, an addition of graphene to carbon black gives two benefits on the electrical properties of carbon black composite as a stretchable electrode.

60 Years since the Armistice Treaty, the NLL and the North-Western Islands (정전협정 60년, NLL과 서북 도서)

  • Jhe, Seong-Ho
    • Strategy21
    • /
    • s.31
    • /
    • pp.27-56
    • /
    • 2013
  • The United Nations Command (UNC) and the communist North failed to reach an agreement on where the maritime demarcation line should be drawn in the process of signing a truce after the Korean War because of the starkly different positions on the boundary of their territorial waters. As a result, the Armistice Treaty was signed on July 1953 without clarification about the maritime border. In the following month, Commander of the UNC unilaterally declared the Northern Limit Line (NLL) as a complementing measure to the Armistice. Referring to this, North Korea and its followers in South Korea wrongfully argue that the NLL is a "ghost line" that was established not based on the international law. However, one should note that the waters south of the NLL has always been under South Korea's jurisdiction since Korea's independence from Japan on August 15, 1945. There is no need to ask North Korea's approval for declaring the territorial waters that had already been under our sovereign jurisdiction. We do not need North Korea's approval just as we do not need Japan's approval with regard to our sovereign right over Dokdo. The legal status of the NLL may be explained with the following three characteristics. First, the NLL is a de facto maritime borderline that defines the territorial waters under the respective jurisdiction of the two divided countries. Second, the NLL in the West Sea also serves as a de facto military demarcation line at sea that can be likened to the border on the ground. Third, as a contacting line where the sea areas controlled by the two Koreas meet, the NLL is a maritime non-aggression line that was established on the legal basis of the 'acquiescence' element stipulated by the Inter-Korea Basic Agreement (article 11) and the Supplement on the Non-aggression principle (article 10). Particularly from the perspective of the domestic law, the NLL should be understood as a boundary defining areas controlled by temporarily divided states (not two different states) because the problem exists between a legitimate central government (South Korea) and an anti-government group (North Korea). In this sense, the NLL problem should be viewed not in terms of territorial preservation or expansion. Rather, it should be understood as a matter of national identity related to territorial sovereignty and national pride. North Korea's continuous efforts to problematize the NLL may be part of its strategy to nullify the Armistice Treaty. In other words, North Korea tries to take away the basis of the NLL by abrogating the Armistice Treaty and creating a condition in which the United Nations Command can be dissolved. By doing so, North Korea may be able to start the process for the peace treaty with the United States and reestablish a maritime line of its interest. So, North Korea's rationale behind making the NLL a disputed line is to deny the effectiveness of the NLL and ask for the establishment of a new legal boundary. Such an effort should be understood as part of a strategy to make the NLL question a political and military dispute (the similar motivation can be found in Japan's effort to make Dokdo a disputed Island). Therefore, the South Korean government should not accommodate such hidden intentions and strategy of North Korea. The NLL has been the de facto maritime border (that defines our territorial waters) and military demarcation line at sea that we have defended with a lot of sacrifice for the last sixty years. This is the line that our government and the military must defend in the future as we have done so far. Our commitment to the defense of the NLL is not only a matter of national policy protecting territorial sovereignty and jurisdiction; it is also our responsibility for those who were fallen while defending the North-Western Islands and the NLL.

  • PDF

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF