• 제목/요약/키워드: non-contact thermometer

검색결과 15건 처리시간 0.023초

외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정 (Investigation of Standard Error Range of Non-Contact Thermometer by Environment)

  • 김정은;박상웅;최혜경
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

가축에서 간이 체온측정 비접촉성 체온계 개발을 위한 임상적 연구 (Clinical Studies for the Development of Non-contact Thermometer to Take Easily the Body Temperature of Domestic Animals)

  • 김용준;이대영;한경호
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.357-363
    • /
    • 2003
  • These studies were carried out to develop non-contact thermometer to take easily the body temperature of domestic animals instead of taking rectal temperature. For the studies, 86 cattle, 57 horses, 72 pigs, 43 goats, and 42 dogs were used and body parts as neck, flank, axilla, lateral abdomen, gluteus, inguinal region, or jugular groove were chosen for taking temperature according to different species. Two types of commercial non-contact thermometers were used to take the temperature of certain body part and at the same time the rectal temperature using digital thermo-meter was taken to compare the difference of temperature between rectum and certain body part. The difference of mean temperature in cattle between rectum and axilla and flank were 0.52 and $2.41^{\circ}C$, respectively, using non-contact thermometer I, whereas $3.02^{\circ}C$ between rectum and flank using thermometer II. The difference of mean temperature in horses between rectum and axilla, gluteus, and jugular groove were 0.52, 1.49, and $0.26^{\circ}C$, respectively, using thermometer I, whereas 2.28 ane $0.92^{\circ}C$ between rectum and gluteus or jugular groove using thermometer II. The difference of mean temperature in swine between rectum and flank, inguinal region, and neck were 1.23, 0.21, and $0.8^{\circ}C$, respectively, using thermometer I, whereas 1.42, 0.711, and $1.25^{\circ}C$ using thermometer II The difference of mean temperature in goats between rectum and lateral abdomen and inguinal region were 1.02 and $0.12^{\circ}C$, respectively, using thermometer I, whereas 1.96 and $1.01^{\circ}C$ using thermometer II. The difference of mean temperature in dogs between rectum and lateral abdomen, inguinal region, and neck were 3.26, 0.24, and $2.37^{\circ}C$, respectively, using thermometer I, whereas 3.45, 0.56, and $2.61^{\circ}C$ using thermometer II.

스마트 개인 인식기반 비접촉 체열측정기 융합 출입통제시스템의 글로벌 시장 진출전략 (Global Market Entry Strategy for Smart Personal Recognition-based Non-contact Thermometer Convergence access Control System)

  • 정재승;김형오
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.673-675
    • /
    • 2021
  • 생체인식 기술은 신뢰성과 편의성을 제공하는 차세대 정보보안기술이며, 글로벌 시장 규모의 상승추세와 비접촉 방식의 수요도 증대되고 있다. 포스트 코로나 시대 핵심기술로 비접촉방식의 생체인식 출입통제 시스템이 비대면과 자동화 기술까지 가능하여, 국내 뿐만 아니라 미국, 유럽, 중동 등 해외시장에서 크레 활약하고 있다. IoT 기반 스마트 디바이스 맞춤형 센서 개발과 H/W 시스템 확보에 기업간 협조와 미국 식약청의 허가 등 요구사항을 반영하여야 하는 주의사항이 있다.

  • PDF

Thermo-tracer를 이용한 온실의 열환경 분석 (Thermal environment analysis of greenhouse using Thermo-tracer)

  • 이석건;이종원;이현우;김란숙
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF

Fullerene과 Polyaniline을 이용한 유기 Peltier소자의 개발 (Preparation of Organic Peltier using Fullerene/Polyaniline)

  • 이채정;김주용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.343-345
    • /
    • 2007
  • Temperature difference between two plates occurs when a current is passed though two semi-conductors that are connected each other at two junctions. The current drives a transfer of heat from one junction to the other. In this study, the thermoelectric module based on th "Peltier effect" was made by combing fullerene and polyaniline. Continuous temperature measurements on both surfaces were performed at room temperature($25.4^{\circ}C$) by an infrared non-contact thermometer. The results showed that cool ing effect of $2.2^{\circ}C$ was attained by 30 seconds, after which the effect was continuously vanished mainly due to electro decomposition.

  • PDF

에폭시 몰드형 BCT의 절연열화 특성 (Characteristics of Insulation Degradation in Epoxy Mold Type BCT)

  • 송재주;이정철;임성훈;고석철;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.902-908
    • /
    • 2005
  • Various stresses (such as electrical stress, mechanical stress, environmental and electrochemical stress, and defects of structure) result in insulation degradation of epoxy mold type insulators. Since the insulation degradation of BCT(Bushing Current Transformer) and bushing proceeds during fabrication process or operation time due to these causes, various methods to reduce the degradation in their insulation ability have been suggested. In this paper, we investigated surface temperature increment of these insulators due to PD(partial discharge). After the voltage applied into the insulator to generate the artificial PD, the surface temperature of the insulator was measured with non-contact thermometer using infrared rays. It was confirmed through the analysis based on PD experiments that the procession in the insulation degradation of the insulator could be estimated through the measurement of the surface temperature in the insulator.

메탈 화이버 버너에서의 연소 특성 및 복사 효율에 관한 실험적 연구 (A Study on the Combustion Characteristics and Radiation Efficiency of Metal Fiber Burners)

  • 박주원;정태용;신동훈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.13-18
    • /
    • 2006
  • Radiant burners are applicable to drying, preheating and curing in materials manufacturing processes. High radiation efficiency is one of the most important performance criteria for these burners. The wide variation in reported radiation efficiencies are partly due to the differences in the measurement techniques. In the present work, water cooled radiant heat flux meter was used to measure radiant heat flux from a metal fiber mat burner. Non-contact type thermometer was also utilized to measure the surface temperature of the burner. Combustion gas was measured by gas analyzers. According to the thermal loads and stoichiometric ratios, radiant heat transfer ratio and combustion performance were discussed here in.

  • PDF

메탈 화이버 버너에서의 연소 특성 및 복사 효율에 관한 실험적 연구 (A Study on the Combustion Characteristics and Radiation Efficiency of Metal Fiber Burners)

  • 박주원;정태용;신동훈
    • 한국연소학회지
    • /
    • 제11권1호
    • /
    • pp.27-33
    • /
    • 2006
  • Radiant burners are applicable to drying, preheating and curing in materials manufacturing processes. Radiation efficiency is one of the important performance criteria for these burners. The wide variation in reported radiation efficiencies are partly due to the differences in the measurement techniques. In the present work, water cooled radiant heat flux meter was used to measure radiant heat flux from a metal fiber mat burner. Non-contact type thermometer was also utilized to measure the surface temperature of the burner. Combustion gas was measured by gas analyzers. According to the thermal loads and stoichiometric ratios, radiant heat transfer ratio and combustion performance were discussed here in.

  • PDF

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • 제52권5호
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

비접촉센서를 이용한 Inconel 718 밀링가공에서 공구상태 감시 (Tool Condition Monitoring with Non-contacting Sensors in Inconel 718 Milling Processes)

  • 최용기;황문창;김영준;박강휘;구준영;김정석
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.445-451
    • /
    • 2016
  • The Inconel 718 alloy is a well-known super-heat-resistant alloy and a difficult-to-cut material. Inconel 718 with excellent corrosion and heat resistance is used in harsh environments. However, the heat generated is not released owing to excellent physical properties, making processes (e.g., adhesion and thermal fatigue) difficult. Tool condition monitoring in machining is significant in reducing manufacturing costs. The cutting tool is easily broken and worn because of the material properties of Inconel 718. Therefore, tool management is required to improve tool life and machinability. This study proposes a method of predicting the tool wear with non-contacting sensors (e.g., IR thermometer for measuring the cutting temperature and a microphone for measuring the sound pressure level in machining). The cutting temperature and sound pressure fluctuation according to the tool condition and cutting force are analyzed using experimental data. This experiment verifies the effectiveness of the non-contact measurement signals in tool condition monitoring.