• Title/Summary/Keyword: noise detector

Search Result 707, Processing Time 0.024 seconds

Evaluation of a Fabricated Charge Sensitive Amplifier for a Semiconductor Radiation Detector

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Lee, Jae-Hyung;Lee, Cheol-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.81-84
    • /
    • 2010
  • A CSA(Charge Sensitive Amplifier) was designed and fabricated for application in a radiation detection system based on a semiconductor detector such as Si, SiC, CdZnTe and etc.. A fabricated hybrid.type CSA was evaluated by comparison with a commercially available CSA. A comparison was performed by using calculation of ENC (Equivalent Noise Charge) and by using energy resolutions of fabricated radiation detectors based on Si. In energy resolution comparison, a fabricated CSA showed almost the same performance compared with a commercial one. In this study, feasibility of a fabricated CSA was discussed.

Dynamic Analysis of ATM Double Bill Detector (ATM기 2매 검지부의 동적 해석)

  • Jeong, Joong-Ki;Suh, Jun-Ho;Baek, Yoon-Kil;Choi, Yeon-Sun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.12 s.117
    • /
    • pp.1208-1214
    • /
    • 2006
  • ATM(automated-teller machine) is a machine that receives and pays money directly. The double bill detector(DBD) module of an ATM detects double bills from its thickness. In this paper, the dynamic behavior of the DBD was analyzed, which cannot be simulated correctly by a package program of SAMCEF. And the displacements of the lever was measured for various bills experimentally. The measured dynamic behaviors were analyzed kinematically using a vector equation and simulated dynamically by the derivation of equation of motion with consideration of damping and stiffness of the DBD and bills. The analysis showed that the spring constant of the system is not so influential, instead, the contact angle between the lever and bill needs to be larger than the existing DBD in order to be laster and reliable DBD.

The Analysis of the Information Capacity of Digital Radiography System (디지탈 X-선 촬영 시스템의 정보용량 분석)

  • 김종효;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 1991
  • In this paper, the information capacity, the intergrate performance measure of digital radiography system has been quantitatively analyzed. The effect of various factors affecting the information capacity of the digital radiography system in multistage detection processes has been considered and analyzed In detail. The results show that the more information capacity can be obtained with the smaller detector cell area, despite of the reduced signal to noise ratio due to the reduced number of X ray photons per detector cell. Considering the limit of human visual acuity, however. the sufficient resolution will be obtained when the detector cell size in $0.2{\times}0.2\textrm{mm}^2$ with 8 bit quantizaion. And also the results indicates that the information capacity may be severely reduced by the mixture of electric noise in final read-out stage.

  • PDF

병원관리 전산화

  • 김윤상
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.49-50
    • /
    • 1982
  • In this paper, the information capacity, the intergrate performance measure of digital radiography system has been quantitatively analyzed. The effect of various factors affecting the information capacity of the digital radiography system in multi-stage detection processes has been considered and analyzed in detail. The results show that the more information capacity can be obtained with the smaller detector cell area, despite of the reduced signal to noise ratio due to the reduced number of X-ray photons per detector cell. Considering the limit of human visual acuity. however, the sufficient resolution will be obtained when the detector cell size in 0.2${\times}$0.2mm with 8 bit quantizaion. And also the results indicates that the information capacity may be severely reduced by the mixture of electric noise in final read-out stage.

  • PDF

HSV Color Model based Hand Contour Detector Robust to Noise (노이즈에 강인한 HSV 색상 모델 기반 손 윤곽 검출 시스템)

  • Chae, Soohwan;Jun, Kyungkoo
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.10
    • /
    • pp.1149-1156
    • /
    • 2015
  • This paper proposes the hand contour detector which is robust to noises. Existing methods reduce noises by applying morphology to extracted edges, detect finger tips by using the center of hands, or exploit the intersection of curves from hand area candidates based on J-value segmentation(JSEG). However, these approaches are so vulnerable to noises that are prone to detect non-hand parts. We propose the noise tolerant hand contour detection method in which non-skin area noises are removed by applying skin area detection, contour detection, and a threshold value. By using the implemented system, we observed that the system was successfully able to detect hand contours.

Novel Structure of 21.6 inch a-Si:H TFT Array for the Direct X-ray Detector

  • Kim, Jong-Sung;Choo, Kyo-Seop;Park, June-Ho;Chung, In-Jae;Joo, In-Su
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.29-31
    • /
    • 2000
  • A 21.6" a-Si:H TFT array for direct conversion X-ray detector with 2480 by 3072 pixels is successfully developed. To obtain X-ray image of satisfactory quality, a novel structure with a storage electrode on BCB is proposed. The structure reduces the parasitic capacitance of data line, which is one of the main sources of signal noise. Also, the structure shows greater resistance to failure than that of the conventional design.

  • PDF

A Simpler Structured Nonparametric Detector with Reference Observations for Random Signals in Multiplicative Noise (적산성 잡음에서 참고 관측량을 쓰는 간단한 구조의 비모수 확률 신호 검파기)

  • Park, Ae-Kyung;Song, Iick-Ho;Bae, Jin-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.4C
    • /
    • pp.379-383
    • /
    • 2003
  • A simpler nonparametric detector test statistic based on reference observation in addition to the rank statistics of regular observations is suggested in this letter. Using reference observations instead of sign statistics helps us a simpler detector structure especially for random signals buried in multiplicative noise.

Whitening Method for Performance Improvement of the Matched Filter in the Non-white Noise Environment (비백색 잡음 환경에서 정합필터 성능개선을 위한 백색화 기법)

  • Kim Jeong-Goo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.3
    • /
    • pp.15-19
    • /
    • 2006
  • In shallow water active sonar environment, reverberation which is a non-white noise is one of the main source of performance degradation of target detection. In this case, the received signal is whitened before applying matched filter known as an optimum filter in the presence of white noise. However implementation of this method is very difficult because of the non-stationary characteristic of reverberation. Traditionally reverberation is assumed local stationary. In this paper, we estimate a range of stationary of reverberation signal, and then propose a pre-whitening method which improve the performance of pre-whitening block normalized matched filter in presence of non-white reverberation noise. Proposed whitener shows better whitening performance than traditional whitener because it use later as well as before reverberation of target signal. To evaluate performance of the proposed whitener, an actual measurement data sampled at the East-Sea is used for computer simulation. The target detector with new whitener is shown better performance than detector with traditional whitener.

  • PDF

Development of Statistical Edge Detector in Noisy Images and Implementation on the Web

  • Lim, Dong-Hoon
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2004.04a
    • /
    • pp.197-201
    • /
    • 2004
  • We describe a new edge detector based on the robust rank-order (RRO) test which is a useful alternative to Wilcoxon test, using $r{\times}r$ window for detecting edges of all possible orientations in noisy images. Some experiments of statistical edge detectors based on the Wilcoxon test and T test with our RRO detector are carried out on synthetic and real images corrupted by both Gaussian and impulse noise. We also implement these edge detectors using Java on the Web.

  • PDF

A New Formula to Predict the Exact Detection Probability of a Generalized Order Statistics CFAR Detector for a Correlated Rayleigh Target

  • Kim, Chang-Joo
    • ETRI Journal
    • /
    • v.16 no.2
    • /
    • pp.15-25
    • /
    • 1994
  • In this paper we present a new formula which can predict the exact detection probability of a generalized order statistics (GOS) constant false alarm rate (DFAR) detector for a partially correlated Rayleigh target model (0 < $ \rho$< 1) in a closed form, where $\rho$ is the correlation coefficient between returned pulses. By simply substituting a set of specific coefficient into the derived formula, one can obtain the detection probability of any kind of CFAR detector. Detectors may include the order statistics CFAR detector, the censored mean level detector, and the trimmed mean CFAR detector, but are not necessarily restricted to them. The numerical result for the first order Markov correlation model as applied to some of the detectors shows that as $\rho$ increases from zero to one, higher signal-to-noise ratio is required to achieve the same detection probability.

  • PDF