• Title/Summary/Keyword: noise detector

Search Result 707, Processing Time 0.025 seconds

A Study on Image Reconstructing Algorithm in Uniformly Distributed Impulsive Noise Environment (균등 분포된 임펄스 잡음 환경에서의 영상 복원 알고리즘에 관한 연구)

  • Noh Hyun-Yong;Bae Sang-Bum;Kim Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1001-1004
    • /
    • 2006
  • Many researches have been processed to reconstruct corrupted an image by noise in fields of signal processing such as image recognition and compute. vision, and AWGN(additive white gaussian noise) and impulse noise are representative. Impulse noise consists of fired-valued(salt & pepper) impulse noise and random-valued impulse noise, and non-linear filters such as SM(standard median) filters are used to remove this noise. But basic SM filters still generate many errors in edge regions of an image, and in order to overcome this problem a variety of methods have been researched. In this paper, we proposed an impulse noise removal algorithm which is superior to the edge preserving capacity. At this tine, after detecting a noise by using the noise detector, we applied a noise removal algorithm based on the min-max operation and compared the capacity with existing methods through simulation.

  • PDF

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

A Study on the Robust Real-Time Signal Processor of a Laser Doppler Vibrometer for Noises (노이즈에 둔감한 레이저 진동계측기용 실시간 신호처리 장치에 관한 연구)

  • Park, Seung-Kyu;Baik, Sung-Hoon;Kim, Cheol-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.61-67
    • /
    • 1999
  • A laser Doppler vibrometer based on the laser heterodyne interferometry is employed to measure the vibration velocity of vibrating objects. In this paper, we propose a real time analog signal processor of a laser Doppler vibrometer to reduce the degradation of Doppler signals mainly caused by environmental noises. In the proposed real time signal processor of an laser Doppler vibrometer, a pre-processor and a logical motion direction detector are designed to reduce the detection errors of the object motion direction. Also, a noise detection and rejection circuit is designed to reject the unfiltered noises.

  • PDF

Performance Limit of NPML Detection on High Density Optical Recording Channels (고밀도 광기록 채널에서의 NPML 검출 성능 한계 분석)

  • Yoon, Min-Young;Lee, Jae-Jin;Hong, You-Pyo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.8C
    • /
    • pp.569-574
    • /
    • 2008
  • Noise predictive maximum likelihood(NPML) detector embeds noise prediction! whitening process in the branch metric calculation of Viterbi detector and improves the reliability. In this paper, some high-density optical storage channels are examined, and appropriate NPML systems are designed for each channel.

A Study on the Implemanation of IF Stage for Reducing Random Noise in the Mobile Communications (이동통신에 적용한 랜덤 잡음 제거를 위한 IF stage 구현에 관한 연구)

  • 이은기;박영철;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.6
    • /
    • pp.572-579
    • /
    • 1992
  • In this thesis, feedback circuit and FM detector applied to superheterodyne receiver to extract audio signal without random noise Is implemented. The feedback loop circuit converts 45MHz received signal to 4SiKHz If signal containing mess-age without random noise. Also the feedback loop provides the End local frequency, so narrowband BPF which is containing maximum Doppler frequency without message Is needed. Finally, quadrature FM detector extract audio signal by synthesis o350" shifted signal and ampli-tude limited signal. RSSI characteristics is measured and audio characteristics Is compared with existing If module.

  • PDF

A Frequency Locked Loop Using a Phase Frequency Detector (위상주파수 검출기를 이용한 주파수 잠금회로)

  • Im, Pyung-Soon;Lee, Dong-Hyun;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.7
    • /
    • pp.540-549
    • /
    • 2017
  • A phase frequency detector(PFD) composed of logic circuits is widely used in a phase locked loop(PLL) due to the easy implementation for integrated circuits. A frequency locked loop(FLL) removes the reference oscillator in the PLL, and the resonator serves as a reference oscillator. A frequency detector(FD) is indispensable for the FLL configuration, and a FD, which is usually composed of a mixer is used to build an FLL. In this paper, instead of FD using mixer, a FD is constructed by using 1.175 GHz resonator composed of microstrip and PFD taking the versatility of PFD into consideration. Using the designed FD, FLL oscillating at a frequency of 1.175 GHz is composed. As a result of comparison with the FLL composed of FD using mixer, it was confirmed that the proposed FLL has better phase noise performance than FLL using mixer FD with FLL bandwidth.

Methods of Random Signal Detection with Rank Statistics : Part 2. The Two-Sqample Case (순위 통계량으로 확률 신호를 검파하는 방법 : 제 2 부. 두 표본을 쓸 때)

  • 송익호;한영옥;엄태상;오택상;류흥균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.5
    • /
    • pp.445-448
    • /
    • 1991
  • The two-sample locally optimum rank detection scheme is obtained which uses rank and sign statistics for detection of random signals in additive noise. It is shown that the detector is similar in structure to the locally optimum detector for random signals and to the one-sample locally optimum rank detector for random signals. It is also shown that the detector is a generalization of the two-sample locally optimum rank detector for known signals. In addition , the problem of two-sample locally optimum rank detection of random signals in multiple input case is considered briefly.

  • PDF

Weak Signal Detection in a Moving Average Model of Impulsive Noise (충격성 잡음의 이동 평균 모형에서 약신호 검파)

  • Kim In Jong;Lee Jumi;Choi Sang Won;Park So Ryoung;Song Iickho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6C
    • /
    • pp.523-531
    • /
    • 2005
  • We derive decision regions of the maximum likelihood(ML) and suboptimum ML(S-ML) detectors in the first order moving average(FOMA) of an impulsive process. The ML and S-ML detectors are compared in terms of the bit-error-rate in the antipodal signaling system. Numerical results show that the S-ML detector, despite its reduced complexity and simpler structure, exhibits practically the same performance as the optimum ML detector. It is also shown that the performance gap between detectors for FOMA and independent and identically distributed noise becomes larger as the degree of noise impulsiveness increases.

Robust spectrum sensing under noise uncertainty for spectrum sharing

  • Kim, Chang-Joo;Jin, Eun Sook;Cheon, Kyung-yul;Kim, Seon-Hwan
    • ETRI Journal
    • /
    • v.41 no.2
    • /
    • pp.176-183
    • /
    • 2019
  • Spectrum sensing plays an important role in spectrum sharing. Energy detection is generally used because it does not require a priori knowledge of primary user (PU) signals; however, it is sensitive to noise uncertainty. An order statistics (OS) detector provides inherent protection against nonhomogeneous background signals. However, no analysis has been conducted yet to apply OS detection to spectrum sensing in a wireless channel to solve noise uncertainty. In this paper, we propose a robust spectrum sensing scheme based on generalized order statistics (GOS) and analyze the exact false alarm and detection probabilities under noise uncertainty. From the equation of the exact false alarm probability, the threshold value is calculated to maintain a constant false alarm rate. The detection probability is obtained from the calculated threshold under noise uncertainty. As a fusion rule for cooperative spectrum sensing, we adopt an OR rule, that is, a 1-out-of-N rule, and we call the proposed scheme GOS-OR. The analytical results show that the GOS-OR scheme can achieve optimum performance and maintain the desired false alarm rates if the coefficients of the GOS-OR detector can be correctly selected.

Image Quality Evaluation of Digital X-Ray Detector Using Amorphous Selenium Layer and Amorphous Silicon TFT Array (비정질 셀레늄층과 비정질 실리콘TFT배열을 사용하는 디지털 X-선 검출기의 영상특성 평가)

  • Kim, Chang-Won;Yoon, Jeong-Key;Kim, Jong-Hyo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.219-226
    • /
    • 2008
  • In this study, we have conducted characterization of imaging performance for a flat panel digital X-ray detector using amorphous Selenium and a-Si TFT which was developed by the authors. The procedures for characterization were in concordance with internationally recommended standards such as IEC (international electrotechnical commission). The measures used for imaging performance characterization include response characteristic, modulation transfer function (MTF), detective quantum efficiency (DQE), noise power spectrum (NPS), and quantum limited performance. The measured DQEs at lowest and highest spatial frequencies were 40% and 25% respectively, which was superior to that of commercial products by overseas vendor. The MTF values were significantly superior to that of CR and indirect type DRs. The quantum limited performance showed the detector was limited by quantum noise at the entrance exposure level below 0.023 mR, which is sufficiently low for general X-ray examination.

  • PDF