• Title/Summary/Keyword: noise absorbing

Search Result 215, Processing Time 0.021 seconds

Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect) (자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과))

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.335-341
    • /
    • 2018
  • With the improvement of medical state, patients' expectations for the most advanced medical equipment are increasing. Particularly, Magnetic Resonance Image (MRI) is used as one of the core image diagnosis methods in all clinical area. However, it has been reported that many of patients who go through the examination suffer from anxiety to the severe noise level during the examination. In this study, both the noise reduction evaluation of headsets with sound-blocking materials added to existing sound-absorbing materials and the existence of sound blocking materials as artifacts on the examination image are tested. An MRI test noise is recorded as a speaker by cross-ordination the sound material (sponge) and the sound material (acrylic plate, copper plate, and 3D copper plate) inside the headset made from 3D pring. A quantitative assessment of headsets showed that the average headset value was 81.8 dB. The average dB value of the most soundproof material combination(Copper, acrylic plate, sponge, sponge) headsets on headsets with added charactering material was measured at 70.4 dB, and MRI showed that the copper was diamagnetic substance and excluded. The second most soundproof headset(Sponge, acrylic plate, 3D copper plate, sponge) was measured at 70.6 dB and MRI showed no artifacts. The same simulation of the material printed with a 3D copper PLA containing approximately 40 % copper powder resulted in no artifacts, therefore, the material output as a 3D printing was better suited for use. For MRI related research, the mutual development of 3D printing is highly anticipated.

Study on the Measurements of Architectural Acoustie by Cross-Correlation Methods (상호상관법에 의한 건축음향측정에 관한 연구)

  • Park, Byoung-Jeon;Shin, Young-Moo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.42-52
    • /
    • 1990
  • A method of measuring impulse response of acoustic system, two kinds of cross-correlation methods (the direct correlation method and the M-sequence modulation correlation method) were applied. According to the direct correlation method, by using stationary random noise source and by calculating the cross-correlation function between the sourece and the output signal, equivalent impulse response can be obtained not being influenced by the back ground noises. By applying this method, the measurement of echo-time patterns in rooms and oblique incident sound absorption characteristics of sound absorbing materials was carried out. In the case of the M-sequence modulation correlation method which was contrived by Aoshima, an intermittent random nosie modulated by M-sequence signal is used as the source signal, and the cross-correlation function between the M-sequence signal and the squared output signal is calculated. According to this method, equivalent energy impulse response (squared impulse response) of te propagation system can be obtained without being influenced by the back ground noises and the air fluctuation caused by wind. As the applcaition of this measuring method to the architectural acoustics, the meaurements of echo-time patterns, reverberation decays and sound pressure lev디 distributions in rooms and sound insulation efficiencies in buildings were carried out. From these experimental studies, it has been found that this M-sequence modulation correlation method is markedly useful especially for the field masurement of sound insulation under high back ground noise condition.

  • PDF

Bowel Sound Recording for Structural Deformity in the Pylorus-Duodenum: Report of 3 Cases (각기 다른 유문-십이지장의 기질적 병변 3증례에 대한 장음 측정 보고 : 장음의 주주파수를 중심으로)

  • Yoon, Sang-hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.276-283
    • /
    • 2015
  • Objectives: The purpose of this study is to report bowel sound patterns recorded in 3 diseases associated with structural deformity of the pylorus-duodenum. Methods: : Bowel sound recording is a useful non-invasive tool for the evaluation of gastrointestinal motility. However, the difficulty in manual attachment of the electronic stethoscope on the abdominal wall and noise production against bowel sound signals have prohibited its widespread use. Therefore, I developed a new apparatus that eliminates the noise; it contains a sound absorbing device and a holder for the head of stethoscope. Using the new bowel sound recording system, bowel sounds of the patients were recorded repeatedly. The endoscopic and abdominal computed tomography findings were obtained from other hospitals' medical record, and all patients were confirmed to have structural deformity in the pylorus-duodenum. The records of each patient were compared and assessed. Results: : Patients had either duodenal ulcer scar, pyloric stricture, or far advanced malignant stomach cancer, as diagnosed by the gastroscopy. Their dominant frequency of bowel sound obtained from the new system was checked more than 2 times at regular intervals. All 8 recordings in the 2 patients with duodenal ulcer scar (5 times) or pyloric stricture (3 times) showed a decrease in postprandial than fasting dominant frequency. One patient with stomach cancer showed no significant change between postprandial and fasting states at 2 recordings. Conclusions: The analysis of dominant frequency in bowel sounds can indicate the existence of pyloric obstruction that could delay gastric emptying.

Performance Qualification Test of the CRDM for JRTR (요르단 연구용원자로 제어봉구동장치의 성능검증시험)

  • Choi, M.H.;Cho, Y.G.;Kim, J.H.;Lee, K.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.12
    • /
    • pp.807-814
    • /
    • 2015
  • A control rod drive mechanism(CRDM) is a reactor regulating system, which inserts, withdraws or maintains a control rod containing a neutron absorbing material within a reactor core to control the reactivity of the core. The top-mounted CRDM for Jordan Research and Training Reactor(JRTR) with 5 MW power has been designed and fabricated based on the HANARO's experience through KAERI and DAEWOO consortium project. This paper describes the performance qualification test results to demonstrate the operability of a prototype and four production CRDMs during the reactor lifetime. The driving performance, the drop performance and the endurance tests for CRDM are carried out at a test rig simulating the actual reactor conditions. A vibration of internal components due to the coolant flow is also measured using a laser vibrometer. As a result, the CRDMs are driven having a good driving performance without a malfunction between command and output signals for the stepping motor. Also, the pure drop time and the impact acceleration are within 0.72 s and 4.2 g to meet the design requirements, and the vibrational displacement of control rod is measured as maximum $5.2{\mu}m$.

Microwave Absorbing Properties of Fe-Si-Al Alloy Flaky Powder-Rubber Composites (Fe-Si-Al 합금 분말 · 고무 복합 자성체의 전파 흡수 특성)

  • Lee Kyung-Sub;Yoon Yeo-Choon;Choi Gwang-Bo;Kim Sung-Soo;Lee Jun-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.228-234
    • /
    • 2005
  • A magnetic composite as noise absorber of quasi-microwave band was developed. The Fe-Si-Al alloy powder were forged by attrition mill to get flaky shape. The magnetic composite sheet was fabricated in which powders are dispersed in polymer and aligned in the direction perpendicular to electromagnetic wave propagation. The permittivity of magnetic composite is increased as forging time increasing, while the permeability is decreased slightly. The maximum attenuation peak of reflection loss is shifted to lower fiequency range as milling time increasing, and the value of maximum attenuation peak is to get smaller gradually. From these result, we could designed a noise absorber sheet (t=1.0 mm) for quasi-microwave band, which is impedance matched at 1.4 GHz with respect to -8.2 dB reflection 1055.

Design of Sound Quality Index for Laser Printers and Its Application for Improvement Study (프린터의 음질 인덱스 제작과 음질개선에 대한 응용)

  • Kim, Eui-Youl;Lee, Young-Jun;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.6
    • /
    • pp.509-523
    • /
    • 2012
  • The sound quality based on design optimization, throughout the development process of various electronic office equipments, needs to be considered in order to respond the increased needs for the emotional satisfaction of customers in terms of psycho-acoustics. This paper focuses on how to describe the characteristics of operating sound radiated from laser printers by using various sound attributes, and to model the sound quality index that can properly evaluate the subjective preference on modification conditions in the improvement study quantitatively. Especially, the proposed verification process, in the form of combining the correlation based method and the decision error based method, was applied to improve the generality and reliability of a group of participants in the jury evaluation. The modified Aures tonality model was also proposed to improve the correlation coefficient with the mean response of participants by optimizing some parameters. As a result, the loudness, articulation index, roughness, tonality, fluctuation strength were used to model the sound quality index for laser printers by using the multiple-linear regression method. Through the improvement study, it was confirmed that replacing the absorbing materials is effective to reduce the tonalness radiated from the side of a reference printer model. Based on above results, it can be concluded that the proposed model has enough usefulness as quantitative evaluation index to evaluate the difference between modification conditions in the improvement study.

Development of the SMPS Power Module for the Medical Kit (SMPS방식을 적용한 의료기기용 전원모듈 개발)

  • Lee, Sangsik;Lee, Kiyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.1
    • /
    • pp.11-15
    • /
    • 2009
  • In this study, we have developed the SMPS(Switched-mode power supply) power module for the medical kit. It is used the medical kit for improved supplying power better than the existing power module in performance, safety and reliability. The developed SMPS(Switched-mode power supply) is composed of the three fundamental electronic circuits, first one is for converting AC power to DC power, second one is for converting to high frequency, and the other is for absorbing noise frequency and preventing malfunction. It is possible for developed SMPS module to enlarge applications for PC, home appliances, switchboard as well as medical instruments.

  • PDF

A study on the sound insulation performance of partition wall between units of apartment house (공동주택 세대간 차음성능에 관한 연구)

  • Ju, Mun Ki;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.51-56
    • /
    • 2010
  • The sound insulation performance is one of the important factor that determined the amenity of housing life in residential building. Especially, Apartment house represents a korea habitation. So the importance of privacy and noise problems between habitable rooms are emphasized in these habitation. This study investigates and find a problem of sound insulation performance of partition wall of the apartment house in current state. The measurements were carried out in apartment house with and without a stair hall. And the measurements also carried out in current state and installing a sound absorbing material in receiving room and changing a front door and installing a inner door. In spite of the same partition wall, difference results were showed according to the stair hall. It is appeared that sound insulation performance without stair hall is 6-7dB(Dw) higher than that with stair hall. In case of without stair hall, sound insulation performance is Dw 49 for single number quantity for airbone sound. And In case of changing a front door and installing a inner door sound insulation performance is Dw 57 for single number quantity for airbone sound. The Results of measuring on the changes a front door and installed a inner door indicated that the flanking sound through front door influenced the sound insulation performance.

A study on the economic analysis of the SL(Self Leveling) Inorganic Floor covering (SL 무기질 바닥재의 경제성 분석에 관한 연구)

  • Park, Ho-Geun;Hong, Seong-Wook;Yang, Je-Yong;Kim, Sang-Won;Shin, Chan-Ho;Choe, Min-Kwon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.105-109
    • /
    • 2011
  • This study is concerned with the development of the SL inorganic floor covering. First, volatile organic compounds, inorganic test profile on the SL through the flooring is environment-friendly inorganic noncombustible floor finishes the event of fire toxic gases (such as volatile organic compounds) emissions have been identified as not at all. Second, SL-breathable material, the concrete floor to prevent aging, long life, which are three levels of noise, shock-absorbing function was decreased. Third, SL economic analysis of mineral flooring terrazzo tile floors compared with the normal material. On a terrazzo tile cost 13,500 won ~ 24,500 won, but It have found that, in terms of labor SL 36,899 won ~ 38,899 won flooring mineral balance. Occurs in the total amount when compared with terrazzo tile floors and 25,399 won 3T, 5T and economical analysis concludes that the original 12,399 won.

  • PDF

Pump Effect by Injected C-band laser in L-band EDFA (L-band EDFA에서 주입된 C-band laser에 의한 펌프 효과)

  • 김익상;김동욱;김창봉
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5A
    • /
    • pp.484-491
    • /
    • 2004
  • C-band pumping effect appears in L-band EDFA because the absorption in C-band occurs dominant under the condition of such a low average population inversion. In this paper, we show how the C-band pumping effect depends on 980nm pump power, the C-band wavelength, and its input power. The C-band pumping is caused by absorbing C-band injection or backward spontaneous emission power through EDF. If the same small signal condition is given by a C-band pump, the C-band pump of a long wavelength is good for the saturation and noise characteristics of L-band signal. Finally, it is considered that in the aspect of saturation characteristics, C-band compensation is not so much efficient as L-band in Gain-Clamped L-band EDFA having a lossy resonator.