• 제목/요약/키워드: nodal solution

검색결과 98건 처리시간 0.022초

유한요소법에 의한 전기기계의 자속분포해석을 위한 MACRO 공선요소 적용에 관한 연구 (A Study on the Application of Macro Air-gap Element for Magnetic Flux Distribution Analysis of Electric Machinery by F.E.M.)

  • Dal-Ho Im
    • 대한전기학회논문지
    • /
    • 제35권11호
    • /
    • pp.479-486
    • /
    • 1986
  • It is necessary to consider a rotor movement in dynamic analysis on the flux distribution of electric machinery by FEM. Therefore, if air-gap domain was subdivided into triangular elements, computation results contain errors due to variation of element shape in air-gap because the nodal points corresponding to the rotor are displaced in analyzing domain for the time difference. In order to reduce this errors, the paper presents a application of a Macro Air-gap Element that interpolation function is obtained analytically and a means to join it with linear triangular elements in the rotating machine or in the linear machine. At the end of paper, setting up analytic domain model, it compares analytic solution with the computation results of Macro Air-gap Element appliction and that of linear triangular element subdivision only to each cases of nodal displacement. And it carries out that errors due to variation of element shape are reduced effectively by application of a Macro air-gap element.

  • PDF

입찰함수에 의한 전력거래에서의 최적조류 계산에 의한 혼잡비용 처리연구 (A Study on the Congestion Management by OPF in the Electricity Power Market with the Bidding Function)

  • 김광호;정재옥
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.374-379
    • /
    • 2000
  • The nodal marginal cost and the congestion charge are used as the econimic signals for the electricity price and new invetments in deregulated power systems. In this paper, the nodal marginal cost and the congestion charge are calculated by using the shadow prices resulted from the calculation of Optimal Power Flow(OPF). Linearization of inequality constraints and piecewise linear cost functions make an OPF problem LP-based forms. In order to use the shadow price, the Interior Point(IP) algorithm is applied as a solution technique to the formulation. This paper proposes an algorithm to determine efficients initial points which are guaranteed to be interior points.

  • PDF

핵연료 재장전모형의 탐색을 위한 경험적 방법론의 제안 (A Proposed Heuristic Methodology for Searching Reloading Pattern)

  • 최기용;윤용구
    • Nuclear Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.193-203
    • /
    • 1993
  • 재장전노심의 핵연료 장전모형 설계를 위한 기존의 알고리즘 탐색방법의 단점을 보완하기 위한 새로운 경험적 탐색방법을 개발하였다. 노심의 핵연료 장전모형으로 고려될 수 있는 수없이 많은 경우의 수를 줄이기 위하여 일반적 핵연료 배치규칙, 영역별 배치방법 그리고 장전모형의 집단화 방법을 이용하였다. 비슷한 장전모형을 모아서 집단화시키는 기준으로 엔트로피 이론을 이용하였다. 또한 PROLOG언어를 이용하여 주어진 배치규칙에 따라 장전모형을 탐색하는 프로그램을 만들었다. 장전모형들의 노심내 출력분포 해석에는 2군 nodal코드인 MEDIUM-2D를 사용하였다. 이와같은 방법을 사용한 결과 수백개 정도의 장전모형 집단을 찾아낼 수 있었고, 여기에 가연성 독봉 배치규칙에 따라 가연성 독봉을 배치한 결과 장전모형 집단의 수를 수십개까지로 감소시킬 수 있었다. 이러한 장전모형 집단들로부터 실제로 이용 가능한 장전모형을 찾아내기 위하여, 주기길이 최대화방법과 첨두 출력 최소화방법을 사용하였다. 그 결과 고리 3호기 제10주기의 예상 재장전모형보다 주기길이는 길고 첨두출력은 낮은 장전모형을 찾아낼 수 있었다.

  • PDF

Betterment of The Tractor Frame Design Applying Computation Mechanics Approach

  • Koike, Masayuki
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.1212-1221
    • /
    • 1993
  • The shape optimization procedure applying finite element method was carried out for the specific purpose of analysis of a tractor chassis frame. Minimization of the mass as an objective function is executed under multiple constrained conditions of nodal displacements and stresses. The optimization process executions were succeeded in converging into single optimum solution. Although mass reduction and stress alleviation were attained by 40% and 26 to 24% respectively , the geometry of the shape is so complicated for fabrication that the refinement of the geometry is of necessity.

  • PDF

Characteristics of Transient Overvoltages for the Towers with Time Varying Tower Footing Resistance

  • Kwak, Hee-Ro
    • 대한전기학회논문지
    • /
    • 제33권3호
    • /
    • pp.118-124
    • /
    • 1984
  • This paper investigated the characteristics of transient overvoltages on the tower caused by time varying tower footing resistance in the path of lightning stroke current entering earth on transmission lines. The tower with time varying tower footing resistance was simulated and the transient overvoltageson the tower due to lightning stroke current were computer by Nodal Solution Method. From the results, it was found that the determination of the steady state values as a limit of inductive tower footing resistance causes higher transient overvoltages than CFO voltages of insulator strings and V-T characteristics of the insulator strings should be considered for computation of backflashover rate.

  • PDF

잡종견의 심장 이식후 발생한 부정맥의 관찰 (Sinus Node Dysfunction after Orthotopic Dog Heart Transplantation)

  • 박국양
    • Journal of Chest Surgery
    • /
    • 제27권5호
    • /
    • pp.339-344
    • /
    • 1994
  • Sinus node dysfunction is common after orthotopic heart transplantation.Electrophysiologic studies have documented a high incidence [46% to 50%] of impaired sinus node automaticity and sinoatrial conduction in the early posttransplantation period. Sinus node dysfunction persists in over 20 % of patients and leads to prolonged bradyarrythmias, including sinus or nodal bradycardia and sinus arrest.The purpose of this paper was to observe sinus node dysfunction after orthotopic heart transplantation. Ten cardiac recipient dogs were monitored continuously after orthotopic transplantations between unrelated adult mongrel dogs. Crystalloid cardioplegic solution [Choongwoi Cardioplegia

  • PDF

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part I : Analytical Study

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.17-26
    • /
    • 2003
  • In this paper, the comparative steady-state operating performance analysis algorithms of the stand-alone single-phase self-excited induction generator (SEIG) is presented on the basis of the two nodal admittance approaches using the per-unit frequency in addition to a new state variable de-fined by the per-unit slip frequency. The main significant features of the proposed operating circuit analysis with the per-unit slip frequency as a state variable are that the fast effective solution could be achieved with the simple mathematical computation effort. The operating performance results in the simulation of the single-phase SEIG evaluated by using the per-unit slip frequency state variable are compared with those obtained by using the per-unit frequency state variable. The comparative operating performance results provide the close agreements between two steady-state analysis performance algorithms based on the electro-mechanical equivalent circuit of the single-phase SEIG. In addition to these, the single-phase static VAR compensator; SVC composed of the thyristor controlled reactor; TCR in parallel with the fixed excitation capacitor; FC and the thyristor switched capacitor; TSC is ap-plied to regulate the generated terminal voltage of the single-phase SEIG loaded by a variable inductive passive load. The fixed gain PI controller is employed to adjust the equivalent variable excitation capacitor capacitance of the single-phase SVC.

유한요소 모델의 절점 활성화 기법 : Ⅰ. 이론 (Node Activation Technique for Finite Element Model : Ⅰ. Theory)

  • 조진연;김도년;김승조
    • 한국항공우주학회지
    • /
    • 제31권4호
    • /
    • pp.26-34
    • /
    • 2003
  • 본 논문에서는 이동최소자승 근사법 등의 무요소 근사법을 이용하여 유한요소모델 절점의 연결성과 무관하게 유한요소 절점을 자유로이 활성화시킬 수 있는 절점활성화 기법을 제안하고, 제안된 방법의 타당성을 고찰하기 위해 일관성 조건, 수치해의 유계성 등에 대한 이론적 고찰을 수행한다. 제안된 절점활성화 기법을 이용하면 많은 수의 유한요소 절점 중 관심이 있는 일부 절점만을 선택, 활성화시켜 이들만을 미지수로 이용하여 문제를 해석할 수 있기 때문에 설계 및 재해석을 효율적으로 수행할 수 있다.

The JFNK method for the PWR's transient simulation considering neutronics, thermal hydraulics and mechanics

  • He, Qingming;Zhang, Yijun;Liu, Zhouyu;Cao, Liangzhi;Wu, Hongchun
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.258-270
    • /
    • 2020
  • A new task of using the Jacobian-Free-Newton-Krylov (JFNK) method for the PWR core transient simulations involving neutronics, thermal hydraulics and mechanics is conducted. For the transient scenario of PWR, normally the Picard iteration of the coupled coarse-mesh nodal equations and parallel channel TH equations is performed to get the transient solution. In order to solve the coupled equations faster and more stable, the Newton Krylov (NK) method based on the explicit matrix was studied. However, the NK method is hard to be extended to the cases with more physics phenomenon coupled, thus the JFNK based iteration scheme is developed for the nodal method and parallel-channel TH method. The local gap conductance is sensitive to the gap width and will influence the temperature distribution in the fuel rod significantly. To further consider the local gap conductance during the transient scenario, a 1D mechanics model is coupled into the JFNK scheme to account for the fuel thermal expansion effect. To improve the efficiency, the physics-based precondition and scaling technique are developed for the JFNK iteration. Numerical tests show good convergence behavior of the iterations and demonstrate the influence of the fuel thermal expansion effect during the rod ejection problems.

Current Conservation Factors for Consistent One-Dimensional Neutronics Modeling

  • Lee, Kibog;Joo, Han-Gyu;Cho, Byung-Oh;Zee, Sung-Quun
    • Nuclear Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.235-243
    • /
    • 2000
  • A one-dimensional neutronics formulation is established within the framework of the nonlinear analytic nodal method such that it can result in consistent one-dimensional models that produce the same axial information as their corresponding reference three-dimension81 models. Consistency is achieved by conserving axial interface currents as well as the planar reaction rates of the three-dimensional case. For current conservation, flux discontinuity is introduced in the solution of the two-node problem. The degree of discontinuity, named the current conservation factor, is determined such that the surface averaged axial current of the reference three-dimensional case can be retrieved from the two-node calculation involving the radially collapsed group constants and the discontinuity factor. The current conservation factors are derived from the analytic nodal method and various core configurations are analyzed to show that the errors in K-eff and power distributions can be reduced by a order of magnitude by the use of the current conservation factor with no significant computational overhead.

  • PDF