• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.032 seconds

Evaluation of an Ammonia Passive Sampler Using Chamber System

  • Yim, Bong-Been;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate the efficiency of a passive sampler in measuring atmospheric ammonia concentrations using chamber system. The ability of the passive sampler to quantitatively determine atmospheric ammonia gas was almost identical to that of the reference method (indophenol method). There was no significant difference between concentrations measured by the two methods. The detection and quantification limits of the ammonia passive sampler were 16.9 ppb and 25.3 ppb, respectively, for a 24-h sampling period. The average coefficient of variation between replicated samplers was $6.7{\pm}4.2%$. The concentrations measured by the two methods (passive sampler and indophenol method) were no significant difference with good a correlation (correlation coefficient=0.964).

Technical study on quantitative analysis of the toxic gas concerning the combustion property of interior materials of railway car (철도차량용 내장 재료의 연소특성을 고려한 유해가스 정량분석 기법연구)

  • Park, Ji-Young;Lee, Cheul-Kyu;Lee, Duck-Hee;Jung, Woo-Sung;Chung, Hoe-Il
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1114-1118
    • /
    • 2008
  • In previous fire accident of railway car, the fatality was relatively high by toxic gas poisoning cause of closed space. So the necessity of quantifying toxic gas in combustion gas was recognized and then, FT-IR spectroscopy was introduced for real-time analysis of mixed gases and stimulated analysis of the concentration of several gases. Thus, in this study, absorption bands using FT-IR were obtained by each component of combustion gases for interior materials of railway car such as flooring materials and moquette seat. And then the sample spectra were compared with the spectra of NO, $NO_2$, $SO_2$ reference gases, we could obtain some identical peaks of them.

  • PDF

Nurses' learning experiences from falling accidents on patient safety (환자안전에 관한 간호사의 경험학습: 낙상 사고를 중심으로)

  • Yoon, Seon-Hee;Kim, Kwang-Jum
    • Korea Journal of Hospital Management
    • /
    • v.20 no.2
    • /
    • pp.1-14
    • /
    • 2015
  • Purpose : The aim of this article is to describe the nurses' experiential learning mechanism on patient safety. Methods : To analyze nurses' learning experiences on patient safety cases, a focus-group interview method was used. The Kolb's experiential learning model was used as a reference model. Findings : Without deep reflective reasoning about specific experiences, there is no creative or innovative solutions to experiment actively. Nurses are likely to be reluctant learners when there is no systemic support from formal departments which is in charge of patient safety and quality of care. Conclusion : In order to build patient safety culture in hospital, there should be efforts to make nurses as active learners on patient safety as well as to build learning environments in medical units.

Multi Function IGBT Gate Driver Including Arm Short Protection (Arm Short 보호 기능을 포함한 다기능 IGBT GATE DRIVER)

  • 이경복;조국춘;최종묵
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.202-209
    • /
    • 2000
  • This paper introduces the main function and protection method of IGBT gate driver that designed by KOROS. Recently, the applications of insulated gate bipolar transistors(IGBTs) have expanded widely, particularly in the area of railway converters. This driver is suitable for railway traction applications, so they are designed for circumstance of railway vehicle such as vibration. The input control power for this driver is supplied from battery charger of railway. it is no necessary an isolated power supply board or auxiliary power supply, with substantial savings in cost and space in railway applications. This gate driver can be used wide range of input voltage. So, performance of the driver has no relation with the battery voltage(70V∼110V). The protection methods of IGBT gate driver have many kind of ways, but this gate driver it designed to apply to converter for railway system, so this gate driver includes protection for arm short current and low control power voltage, etc. And the process of protection method and protection reference value are optimized by means of sufficient test with our own facilities.

  • PDF

Classification of Cognitive Mental States for Brain Wave based Human-Computer Interface (뇌파기반 휴먼-컴퓨터 인터페이스를 위한 인지적 정신상태의 분별)

  • 신승철
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.61-64
    • /
    • 2001
  • This paper describes a basic study for the classification of cognitive mental states as a basic research of a human-computer interface technique. To recognize the mental states, we obtained 22 subjects’brain waves in course of two types of experiments. One of the experiments is to choose an answer among yes, no or reject buttons, to underlying questions and the other is to select an icon displayed in a monitor screen. After acquiring the brain wave signals, we construct a feature set with the percent power increase for a given segment with respect to that of the reference period. The linear discriminative algorithm is used to classify the cognitive yes/no mental states.

  • PDF

The Promotion for the system refurbishment technique by the signalling system interoperability (신호시스템 병행운전 구성을 이용한 시스템 개량 기술 제고)

  • Kho, Young-Whan;Choi, Jong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1448-1453
    • /
    • 2006
  • The Seoul Metro Line No.1 is a very complex service line which carries over 620 thousand passengers a day as a linked line to the satellites of the Seoul Metropolitan. Since the Line No.1 had its voyage service in 1974. it has been aged by the time, which resulted in the needs for the refurbishment to the new system, and as its system refurbishment was suggested to be implemented without any stop of the service, the signaling system interoperability was planned for this refurbishment, and finally it became a desirable reference of the metro signaling system overall refurbishment

  • PDF

Studies on the Physiology of Hibernation - with particular reference to blood level of insulin - (동면에 관한 연구 - 혈중 Insulin 농도의 변화 -)

  • Kang, Bok-Soon;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 1972
  • Physiological changes in hibernating animals (Manchurian Chipmunk and Hamster) were studied during various phases of the hibernation. The results obtained are summarized as follows. 1. Rectal temperature was declined markedly during hibernation, whereas it remained constant even in exposure of the animals to 0 C environment if the animals were not prepared for hibernation. As body temperature was lowered, heart rate was also markedly reduced as well as respiration and blood pressure. 2. The electrical activity recorded from cortical structure was characterized by replacement of fast wave activity by slow wave activity as body temperature was lowered and became flat at body temperature below 20C. 3. Blood glucose level showed no clear seasonal variations. However, the glycogen contents of the liver were markedly greater during the cold seasons than during the warm seasons. 4. Blood levels of insulin showed no clear seasonal variations.

  • PDF

Conservation Treatment of the Plate Armour Excavated from the No. 2 Tomb, Daeseong-dong, Gimhae (김해(金海) 대성동(大成洞) 2호분(號墳) 출토(出土) 갑옷(판갑(板甲))의 보존처리(保存處理))

  • Oh, Kwangseob;Kim, Midori;Lim, Jihyun;Kang, Jungmoo
    • Conservation Science in Museum
    • /
    • v.4
    • /
    • pp.41-46
    • /
    • 2003
  • Remarkable features, such as neck guard and plate designed the shape of a duck, are identified in the process of conservation for the plate armour excavated from the No. 2 tomb, Daeseong-dong, Gimhae. We considered that should be careful for treating this kind of artifacts, especially when restoring to its original. For this purpose, we thoroughly studied the endurance of materials for restoration and applied the techniques in reference to the traditional method.

Basic Studies on Correlations between Postpartum Edema and Heart Rate Variability (산후부종과 HRV의 연관성에 관한 기초연구)

  • Hwang, Jae-Ho;Yun, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.24 no.4
    • /
    • pp.186-193
    • /
    • 2011
  • Purpose: This study was performed to find correlations between Edema Index and Heart Rate Variability(HRV) conducted in early postpartum period. Methods: 17 postpartum women were participated in this study which was conducted with Inbody 720(Biospace Co. Ltd.) and SA-6000(Medicore Co. Ltd.). Edema Index(Extra Cellular Water/Total Body Water) was calculated after body composition analysis and HRV result(TP, VLF, LF, HF, HF norm, LF norm, LF/HF ratio) was analysed within a week after delivery. Results: There was no significant correlations between Edema Index and HRV results in time domain analysis. also Edema Index and TP, LF, HF, LF/HF ratio have no significant correlations in frequency domain analysis. but only VLF data has significance compared with Edema Index. Conclusions: It can be suggested that VLF results analysed by HRV can be useful reference estimating postpartum edema especially occurs in early postpartum period.

Pharmacokinetic Properties and Bioequivalence of Cefcapene Pivoxil Hydrochloride 75 mg in Korean Healthy Volunteers (건강한 한국인 피험자에서 Cefcapene Pivoxil Hydrochloride 75 mg 제제의 생물학적동등성시험)

  • Jeon, Ji-Young;Im, Yong-Jin;Hwang, Min-Ho;Kim, Yun-Jeong;Han, Su-Mi;Jo, Myeong-Jin;Kim, Hee-Sun;Kim, Sun-Young;Chae, Soo-Wan;Kim, Kang-Seog;Kim, Min-Gul
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.1
    • /
    • pp.9-12
    • /
    • 2012
  • Background: Cefcapene pivoxil hydrochloride, is an ester-type oral cephem antibiotic. This study was performed to compare the pharmacokinetics and evaluate the bioequivalence of two cefcapene pivoxil hydrochloride 75 mg formulations. Method: In a randomized $2{\times}2$ crossover study, sixty healthy male volunteers were randomly assigned into two groups. After a single dose of 75 mg cefcapene pivoxil hydrochloride oral administration, blood samples were collected at specific time intervals from 0-12 hours. The plasma concentrations of cefcapene pivoxil hydrochloride were determined by LC-MS/MS. The pharmacokinetic parameters were determined from the plasma concentration-time profiles of both formulations. The pharmacokinetic parameters such as $AUC_{last}$, $AUC_{inf}$ and $C_{max}$, were calculated and the 90% confidence intervals for test/reference ratio for pharmacokinetic parameters were obtained by analysis of variance on logarithmically transformed data. Results: The mean value for $AUC_{last}$ in test and reference drug was $4053.1{\pm}876.5\;ng{\cdot}hr/mL$ and $3595.7{\pm}1029.1\;ng{\cdot}h/mL$, respectively. The mean value for $C_{max}$ in test and reference drug was $1324.9{\pm}321.4$ ng/mL and $1159.1{\pm}335.9$ ng/mL, respectively. The 90% confidence intervals of the $AUC_{last}$ and $C_{max}$ ratio for test drug and reference drug were log 1.09-log1.22 and log 1.09-log1.24, respectively. No adverse events were reported by subjects or found on analysis of vital signs or laboratory tests. Conclusion: This single dose study found that the test and reference products met the regulatory criteria for bioequivalence in these health volunteers. Both formulations were safe and well tolerated in 75 mg of cefcapene pivoxil hydrochloride.