• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.031 seconds

Quasi-Transient Method for Thermal Response of Blunt Body in a Supersonic Flow (준-비정상해석 기법을 통한 초음속 유동 내 무딘 물체의 열응답 예측)

  • Bae, Hyung Mo;Kim, Jihyuk;Bae, Ji-Yeul;Jung, Daeyoon;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.495-500
    • /
    • 2017
  • In the boundary layer of supersonic or hypersonic vehicles, there is the conversion from kinetic energy to thermal energy, called aerodynamic heating. Aerodynamic heating has to be considered to design supersonic vehicles, because it induces severe heat flux to surface. Transient heat transfer analysis with CFD is used to predict thermal response of vehicles, however transient heat transfer analysis needs excessive computing powers. Loosely coupled method is widely used for evaluating thermal response, however it needs to be revised for overestimated heat flux. In this research, quasi-transient method, which is combined loosely coupled method and conjugate heat transfer analysis, is proposed for evaluating thermal response with efficiency and reliability. Defining reference time of splitting flight scenario for transient simulation is important on accuracy of quasi-transient method, however there is no algorithm to determine. Therefore the research suggests the algorithm with various flow conditions to define reference time. Supersonic flow field of blunt body with constant acceleration is calculated to evaluate quasi-transient method. Temperature difference between transient and quasi-transient method is about 11.4%, and calculation time reduces 28 times for using quasi-transient method.

A Clinical Study of Soft Tissue Changes of the Midface after Mandibular Setback Surgery (하악골 후방이동시 중안면부 연조직의 변화양상에 대한 임상통계학적 연구)

  • Han, Dae-Hee;Kim, Soo-Nam;Min, Seung-Ki;Kim, Tae-Seong;Sung, Hun-Mo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.319-329
    • /
    • 2000
  • Prediction of the soft tissue changes following hard tissue movement is very important from the esthetic view point for patients who have orthognathic surgery. There are many cephalometric analysis of facial bone and soft tissue on the lower lip and chin region but few soft tissue analysis on the midface after mandibular setback surgery. This study was performed to obtain whether the mandibular posterior movement has influence on the midface and the predictable ratio of post-operative measurement values of the soft tissue changes following mandibular setback surgery. Fifteen patients (8 males and 7 females) who had undergone mandibular setback surgery were selected and analyzed the soft tissue movement on the upper lip and the cheek region. Post-operative changes of the soft tissue measurements after mandibular surgery were examined on pre- and post-operative cephalometrics and the ratio of changes were analyzed after drawing the reference line on the face with the barium sulfate solution. The reference lines were perpendicular to the intercanthal line from infraorbital foramen and lateral canthus. The results obtained were as follows : 1. There were tendancy of anterior movement of soft tissue adjacent the nose after mandibular surgery 2. There were incerased tendancy of the amount of anterior movement from the nasal crease to the cheek region. 3. The amount of anterior movement of the soft tissue was larger below the palatal plane compared with above the palatal plane in the cheek region. 4. The upper lip length was increased and moved posterior direction after mandibular setback surgery 5. The lower lip was moved posterior direction by posterior movement of the mandibular structure 6. Soft tissue of the midface around the nose moved anterior direction after mandibular setback surgery but there was no correlation between the amount of mandibular setback and the amount of the soft tissue changes

  • PDF

Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology (대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구)

  • Park, Duck Shin;Kwon, Soon Bark;Cho, Young Min;Jang, Seong Ki;Jeon, Jae Sik;Park, Eun Young
    • Particle and aerosol research
    • /
    • v.6 no.1
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

Synthesis of (4-$[^{18}F]$Fluorophenyl)triphenylphosphonium as a Mitochondrial Voltage Sensor for PET (PET영상용 미토콘드리아 막전위 감지기 (4-$[^{18}F]$Fluorophenyl)triphenylphosphonium의 합성)

  • Kim, Dong-Yeon;Yu, Kook-Hyun;Bom, Hee-Seung;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.561-565
    • /
    • 2007
  • Purpose: Lipophilic cations including tetraphenylphosphonium (TPP) salts penetrate the hydrophobic barriers of the plasma and mitochondrial membranes, resulting in accumulation in mitochondria in response to the negative inner transmembrane potentials. The development of radiolabeled phosphonium cations as a noninvasive imaging agent may serve as a new molecular "voltage sensor" probe to investigate the role of mitochondria in the pathophysiology and diagnosis of cancer. Materials and Methods: We have synthesized a reference compound (4-fluorophenyl)triphenylphosphonium (TPP) and a labeled compound $[^{18}F]$TPP via two step nucleophilic substitution of no-carrier-added $[^{18}F]$fluoride with the precursor, 4-iodophenyltrimethylammonium iodide, in the presence of Kryptofix-2.2.2 and $K_2CO_3$. Result: The reference compound (4-fluorophenyl)triphenylphosphonium (TPP) was synthesized in 60% yield. The radiolabeled compound $[^{18}F]$TPP was synthesized in $10\sim15%$ yield. The radiochemical purity of the $[^{18}F]$TPP was $95.57{\pm}0.51%$ (n=11). Conclusion: $[^{18}F]$TPP was successfully synthesized that might have a potential to be utilized as a novel myocardial or cancer imaging agent for PET. However, it is required to improve the radiochemical yield to apply $[^{18}F]$TPP in preclinical or clinical researches.

A Study on the Design of EA Performance Evaluation Model and the Application Case (EA성과평가 모델의 설계 및 적용사례에 관한 연구)

  • Lee, Seok-Kyun;Lee, Young-Min;Rhew, Sung-Yul
    • The KIPS Transactions:PartD
    • /
    • v.16D no.3
    • /
    • pp.395-406
    • /
    • 2009
  • Korean government has operated EA by the act on efficient introduction of information system and operation, etc. But the evaluation system for EA and the criteria don't prepare well. Particularly, There is no model for EA performance measurement and the way is insufficient. In this study, we derived 8 areas and 17 criteria for the performance evaluation based on the Performance Reference Model of U.S FEA and Korea. And we also derived 8 areas and 10 criteria for it based on the OMB EA Assessment Framework and the EA maturity model in Korea. We propose the performance evaluation model of the five areas that consists of the business performance, customer performance, process, human resource and the technology for EA performance evaluation. To verify the model, we applied the model to three organizations and evaluated EA performance. In addition, we compared the performance result with the performance evaluation area of EA maturity model of Korea to verify the result. We also analyzed the criteria of the proposed performance evaluation model with the current EA maturity model and Performance Reference Model of Korea. As a result of the evaluation, we verified of the proposed performance evaluation model, too.

Bioequivalence of Atorva Tablet® to Lipitor Tablet® (Atorvastatin 20 mg) (리피토정® (아토르바스타틴 20 mg)에 대한 아토르바정®의 생물학적동등성)

  • Lim, Hyun-Kyun;Lee, Tae-Ho;Lee, Jae-Hyun;Youm, Jeong-Rok;Song, Jin-Ho;Han, Sang-Beom
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • The present study describes the evaluation of the bioequivalence of two atorvastatin tablets, Lipitor $Tablet^{(R)}$ (Pfizer, reference drug) and Atorva $Tablet^{(R)}$ (Yuhan, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Forty-nine healthy male Korean volunteers received each medicine at the atorvastatin dose of 40 mg in a $2{\times}2$ crossover study with a two weeks washout interval. After drug administration, serial blood samples were collected at a specific time interval from 0-48 hours. The plasma atorvastatin concentrations were monitored by an high performance liquid chromatography -tandem mass spectrometer (LC-MS/MS) employing electrospray ionization technique and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.5 min and calibration curves were linear over the concentration range of 0.1-100 ng/mL for atorvastatin. The method was validated for selectivity, sensitivity, linearity, accuracy and precision. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48hr) was calculated by the linear log trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were complied trom the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Atorva $Tablet^{(R)}$ / Lipitor $Tablet^{(R)}$ were ${\log}\;0.9413{\sim}{\log}\;1.0179$ and ${\log}\;0.831{\sim}{\log}\;1.0569$, respectively. These values were within the acceptable bioequivalence intervals of ${\log}\;0.8{\sim}{\log}\;1.25$. Based on these statistical considerations, it was concluded that the test drug, Atorva $Tablet^{(R)}$ was bioequivalent to the reference drug, Lipitor $Tablet^{(R)}$.

LiDAR Chip for Automated Geo-referencing of High-Resolution Satellite Imagery (라이다 칩을 이용한 고해상도 위성영상의 자동좌표등록)

  • Lee, Chang No;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.319-326
    • /
    • 2014
  • The accurate geo-referencing processes that apply ground control points is prerequisite for effective end use of HRSI (High-resolution satellite imagery). Since the conventional control point acquisition by human operator takes long time, demands for the automated matching to existing reference data has been increasing its popularity. Among many options of reference data, the airborne LiDAR (Light Detection And Ranging) data shows high potential due to its high spatial resolution and vertical accuracy. Additionally, it is in the form of 3-dimensional point cloud free from the relief displacement. Recently, a new matching method between LiDAR data and HRSI was proposed that is based on the image projection of whole LiDAR data into HRSI domain, however, importing and processing the large amount of LiDAR data considered as time-consuming. Therefore, we wmotivated to ere propose a local LiDAR chip generation for the HRSI geo-referencing. In the procedure, a LiDAR point cloud was rasterized into an ortho image with the digital elevation model. After then, we selected local areas, which of containing meaningful amount of edge information to create LiDAR chips of small data size. We tested the LiDAR chips for fully-automated geo-referencing with Kompsat-2 and Kompsat-3 data. Finally, the experimental results showed one-pixel level of mean accuracy.

An Analysis of the Librarians' Perception of Providing CHI Services in Public Libraries (공공도서관에서 소비자건강정보를 제공하는 것에 대한 사서의 인식 조사연구)

  • Noh, Young-Hee;Oh, Sang-Hee
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.22 no.3
    • /
    • pp.25-55
    • /
    • 2011
  • These results of surveying public librarians can contribute to clearly identifying the status of CHI(consumer health information) services in Korea and to exploring future developments in CHI services. In this study, we investigated whether or not currently Korean public libraries are offering CHI services, whether or not they provide CHI reference services and the frequency of their use, and analyzed librarians' recognition of the need for Korean public libraries to provide the CHI services. The findings are as follows: 1) 70% of Korean public libraries are equipped with health-related books and medical journals, but the rate of libraries that are building CHI-related websites was very low at 5%. 2) The rate of providing the CHI reference services was only 30% of the surveyed public libraries. 3) 82.1% of public libraries did not provide educational programs related to CHI. 4) 82.1% of public libraries did not provide CHI-related services for vulnerable groups. 5) The rate of providing the CHI-related outreach programs and collaborating with CHI-related institutions was no more than about 20% each. These research findings can induce public librarians to provide CHI services in public libraries, and will contribute to activate the CHI-related research in Korea.

Size-Specific Dose Estimation In the Korean Lung Cancer Screening Project: Does a 32-cm Diameter Phantom Represent a Standard-Sized Patient in Korean Population?

  • Kim, Eun Young;Kim, Tae Jung;Goo, Jin Mo;Kim, Hyae Young;Lee, Ji Won;Lee, Soojung;Lim, Jun-tae;Kim, Yeol
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1179-1186
    • /
    • 2018
  • Objective: The purposes of this study were to evaluate size-specific dose estimate (SSDE) of low-dose CT (LDCT) in the Korean Lung Cancer Screening (K-LUCAS) project and to determine whether CT protocols from Western countries are appropriate for lung cancer screening in Korea. Materials and Methods: For participants (n = 256, four institutions) of K-LUCAS pilot study, volume CT dose index ($CTDI_{vol}$) using a 32-cm diameter reference phantom was compared with SSDE, which was recalculated from $CTDI_{vol}$ using size-dependent conversion factor (f-size) based on the body size, as described in the American Association of Physicists in Medicine Report 204. This comparison was subsequently assessed by body mass index (BMI) levels (underweight/normal vs. overweight/obese), and automatic exposure control (AEC) adaptation (yes/no). Results: Size-specific dose estimate was higher than $CTDI_{vol}$ ($2.22{\pm}0.75mGy$ vs. $1.67{\pm}0.60mGy$, p < 0.001), since the f-size was larger than 1.0 for all participants. The ratio of SSDE to $CTDI_{vol}$ was higher in lower BMI groups; 1.26, 1.37, 1.43, and 1.53 in the obese (n = 103), overweight (n = 70), normal (n = 75), and underweight (n = 4), respectively. The ratio of SSDE to $CTDI_{vol}$ was greater in standard-sized participants than in large-sized participants independent of AEC adaptation; with AEC, SSDE/$CTDI_{vol}$ in large- vs. standard-sized participants: $1.30{\pm}0.08$ vs. $1.44{\pm}0.08$ (p < 0.001) and without AEC, $1.32{\pm}0.08$ vs. $1.42{\pm}0.06$ (p < 0.001). Conclusion: Volume CT dose index based on a reference phantom underestimates radiation exposure of LDCT in standard-sized Korean participants. The optimal radiation dose limit needs to be verified for standard-sized Korean participants.

A Survey on Usage of Korean Standard Records Management System (표준기록관리시스템의 활용현황 연구)

  • Lee, So-Yeon
    • The Korean Journal of Archival Studies
    • /
    • no.43
    • /
    • pp.71-102
    • /
    • 2015
  • The present study aims at investigating the current usage patterns of Korean Standard Records Management System. The Korean Standard Records Management System has been designed and distributed by the National Archives Korea in order to support records management of public agencies. An email survey has been sent to 4 types of public agencies: central government agencies, provincial governments, provincial education offices as well as city and county offices. While all agencies are included in the survey for the first three types, only two provincial districts are selected for city and county offices, Out of 101 email questionnaires sent, 65 are returned(63.73%). The results show the usage patterns of 240 functionalities aligned to 9 main functions: accession from records creators, preservation, appraisal, accession to the national archives, reference management, access and tracking, retrieval and use, system management as well as freedom of information management by public institutions. Since its launch in 2007, the system has been distributed to 707 public agencies as of late 2014. The problem is that there has been no attempt to evaluate the functionalities and usabilities of the system. Only grievances from those agencies implemented the system have never been ceased. The present study is expected to offer the levelled ground for productive discussion between the national archives and the agencies.