• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.026 seconds

Clay Mineral Characteristics of 420 MV (Mud Volcano) in Beaufort Sea, Arctic Ocean (북극 보퍼트해 420 MV (진흙화산)의 점토광물 특성)

  • Jang, Jeong Kyu;Koo, Hyo Jin;Cho, Hyen Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.51-61
    • /
    • 2019
  • Clay minerals, a major component of mud volcano (MV) sediments, are expected to provide important information for characterizing mud volcano formation mechanisms, but clay minerals have rarely been studied. The purpose of this study is to investigate the characteristics of 420 MV and surrounding marine sediments. Clay minerals and grain size were analyzed for 8 box cores from 420 MV and Mackenzie Trough. The relative proportions of the four major clay minerals in the Mackenzie Trough are almost constant in the order of illite, chlorite, kaolinite, and smectite, regardless of the distance from the Mackenzie River. However, the grain size tends to become fining as they move away from the Mackenzie River. Comparing the clay mineral characteristics of river (Colville River, Kuparuk River, Sagavanirktok River, Canning River, Mackenzie River) sediments entering the Beaufort Sea in order to determine the origin of the Mackenzie Trough and 420 MV sediments, the sediments of the Mackenzie Trough are characterized mainly by the Mackenzie River with a low ratio of smectite/illite and a high ratio of kaolinite/chlorite. In 420 MV sediments, the contents of clay minerals decrease in the order of illite, kaolinite, chlorite, and smectite, and the grain size with depth is almost constant. The content of smectite and coarse sediments is about two times higher than the reference core. No river with higher kaolinite content than chlorite exists in the Beaufort Sea, and the ratio of smectite/illite to kaolinite/chlorite is different from the reference core such as the ratio of the Mackenzie River. Compared to the reference core, the high contents of coarse sediments and the constant grain size with depth might be attributed to the ejection by MV. The reference core is interpreted as originating from Mackenzie River, and sediment of 420 MV is interpreted as originating from eruption of MV.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.

Observation of Volume Change and Subsidence at a Coal Waste Dump in Jangseong-dong, Taebaek-si, Gangwon-do by Using Digital Elevation Models and PSInSAR Technique (수치표고모델 및 PSInSAR 기법을 이용한 강원도 태백시 장성동 폐석적치장의 적치량과 침하관측)

  • Choi, Euncheol;Moon, Jihyun;Kang, Taemin;Lee, Hoonyol
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1371-1383
    • /
    • 2022
  • In this study, the amount of coal waste dump was calculated using six Digital Elevation Models (DEMs) produced between 2006 and 2018 in Jangseong-dong, Taebaek-si, Gangwon-do, and the subsidence was observed by applying the Persistent Scatterer Interferometric SAR (PSInSAR) technique on the Sentinel-1 SAR images. As a result of depositing activities using DEMs, a total of 1,668,980 m3 of coal waste was deposited over a period of about 12 years from 2006 to 2018. The observed subsidence rate from PSInSAR was -32.3 mm/yr and -40.2 mm/yr from the ascending and descending orbits, respectively. As the thickness of the waste pile increased, the rate of subsidence increased, and the more recent the completion of the deposit, the faster the subsidence tended to occur. The subsidence rates from the ascending and descending orbits were converted to vertical and horizontal east-west components, and 22 random reference points were set to compare the subsidence rate, the waste rock thickness, and the time of depositing completion. As a result, the subsidence rate of the reference point tended to increase as the thickness of the waste became thicker, similar to the PSInSAR results in relation to the waste thickness. On the other hand, there was no clear correlation between the completion time of the deposits and the rate Of subsidence at the reference points. This is because the time of completion of the deposits at all but 5 of the 22 reference points was too biased in 2010 and the correlation analysis was meaningless. As in this study, the use of DEM and PSInSAR is expected to be an effective alternative to compensate for the lack of field data in the safety management of coal waste deposits.

A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography (디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰)

  • Yeon-Jin, Jeong;Young-Cheol, Joo;Dong-Hee, Hong;Sang-Hyeon, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.897-904
    • /
    • 2022
  • The purpose of this study is to compare the difference in dose and image quality when applying the diagnostic reference level (DRL) test conditions for head radiography in a digital radiation environment and the test conditions currently applied in clinical practice. I would like to review the conditions of radiographic examination. In this study, the head model phantom was targeted, and the investigation conditions were divided into clinical conditions (Clinic), DRL value (DRL75), and DRL average value (DRLmean). For dose, Enterance surface dose (ESD) was measured, and for image quality, signal-to-noise ratio and contrast-to-noise ratio were measured and analyzed for comparison. The average values of skull anterior posterior(AP) ESD according to the changes in test conditions were Clinic 1214.03±4.21 µGy, DRL75 3017.83±8.14 µGy, DRLmean 2283.50±7.09 µGy, and skull lateral (Lat). The average value of ESD was statistically significant with Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, and DRLmean 1654.43±6.48 µGy (p<0.01). The average values of SNR and CNR measured in the orbital, maxillary sinus, frontal sinus, and sella turcica were statistically significant (p<0.01). As a result of this study, compared to DRL, the conditions used in clinical practice showed lower dose levels of about 58% for AP and about 70% for Lat., and there was no qualitative difference in terms of image quality. Through this study, it is necessary to consider a new diagnostic reference level suitable for the digital radiation environment, and it is considered that the dose should be reduced accordingly.

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

The Effects of RPE of Step Aerobics on the Immunologic Function of High School Girls (Step aerobics의 RPE가 여고생의 면역기능에 미치는 영향)

  • Kwon, Sun-Ok;Jeong, Seon-Tae
    • Journal of Life Science
    • /
    • v.20 no.2
    • /
    • pp.304-313
    • /
    • 2010
  • Out of the tenth graders of K girl's high school in J city, 24 students whose %fat was over 30% were divided into 3 groups through Purposing Sampling. Groups A and B were exercise groups and C was the control group. Using Borg's RPE (rating of perceived exertion), RPE 15-17 (hard-very hard) $\times$ 3 sets were set up for group A, RPE 11-13 (fairly light-somewhat hard) $\times$ 3 sets were set up for group B, and both groups performed step aerobics (step box: 68cm in length, 28cm in width, 15cm in hight, 450g in weight) for 50-60 minutes a day, 3 days a week for 8 weeks in total. This research was conducted to find out the effects of various RPE in step aerobics on the immunologic function (neutrophil, lymphocyte, monocyte, eosinophil, basophil, IgG, IgA, and IgM levels) of overweight female high school students. By using SPSS Ver. 14.0, a repeated two-way ANOVA was conducted to find out the effects of interaction between the groups and time period, paired t-test to evaluate data within each group, and pre- and post experiment difference rates (%diff) to perform one-way ANOVA for group comparisons. The following results were found. As for WBC, within group A, neutrophil, monocyte, basophil, and eosinophil levels increased, while lymphocyte levels remained the same. Within group B, eosinophil levels decreased while neutrophil, lymphocyte, monocyte, and basophil levels showed no differences. Within the control group, neutrophil, basophil, and eosinophil levels decreased while lymphocyte and monocyte levels showed no differences. As for the group comparisons, neutrophil levels increased more in group A than group B and the control group. There were no differences in lymphocyte levels among the three groups. Monocyte levels increased more in group A and B than the control group. Basophil and Eosinophil increased more in group A than group B and the control group. As for immunoglobin, within group A, the IgG level increased but the levels of IgA and IgM did not change. Within group B, the IgA level increased but the level of IgG decreased, and the level of IgM did not change. Within the control group, the IgG level decreased but the levels of IgA and IgM did not change. As for the group comparisons, the level of IgA increased more in group A than the control group, and the level of IgG increased more in group A than group B and the control group, but levels of IgM among the three groups did not show any difference. In summary, WBC and Ig levels showed that the three groups remained at the reference interval even after the exercise program. However, group A, which performed RPE 15-17 in step aerobics, showed increase in more measured items than the other groups, and this implies that the immunologic function has improved in the range of the reference intervals. Therefore, it will be effective to conduct step aerobics with the RPE 15-17 (hard-very hard) in order to increase the immunologic function.

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

Multi-Protocol Based Routing Selection Scheme for MANET Using Mobility and Connectivity (MANET에서 이동성과 연결성을 고려한 다중 모드 라우팅 프로토콜 적용 기법)

  • Heo, Ung;Wan, Xin;Zhao, Yi;You, Kang-Soo;Choi, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.5
    • /
    • pp.40-52
    • /
    • 2010
  • A mobile ad hoc network is instant and heuristic, and it is also vulnerable and volatile. Since topology and route changes are frequent, no single routing protocol designed for a conventional network performs well. Some protocols suffer from significant performance degradation when the number of nodes increases, or when nodes become highly mobile. In this paper we investigate a way to adaptively select a routing protocol that fits to the real-time network conditions. The first phase of our study is to analyze the performances of two classes of routing protocols under various network scenarios. The second phase consists of constructing a routing protocol selection reference. All nodes continue to monitor the status of neighbor nodes and control packets exchanged. Then, the aggregated information is periodically compared against the protocol selection reference. The selected routing protocol is maintained throughout the network until the network property changes substantially. The performance of the proposed algorithm is verified by a set of computer simulations using the OPNET modeler. The experimental results show that selectively changing routing protocol adaptive to the network conditions greatly improves the efficacy of bandwidth utilization.

The Ecological Health Screening Assessment of Agricultural area using Biomarkers and Bioindicators in Misgurnus Anguillicaudatus (case study) (미꾸리의 생물지표를 이용한 농업지역의 수생태계 건강성 스크리닝 평가(사례연구))

  • Kim, Ja-Hyun;Han, Sun-Young;Yeom, Dong-Hyuk
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.1
    • /
    • pp.62-68
    • /
    • 2012
  • This study evaluated the screening level assessment of ecological health using four biomarkers and four bioindicators of Misgurnus anguillicaudatus as a indicator species in agricultural area of South Korea during May-June 2011. The endocrine disrupting chemical (EDC) indicators, such as vitellogenin (VTG) and gonado-somatic index (GSI), were not significantly changed in the agricultural site (p>0.05), indicating no effects. The biomarkers and bioindicators were compared between two sites of reference site (RS) and the agricultural site (AS) for screening assessment of ecological health. The ethoxyresorufin-O-deethylase (EROD) activity, acetylcholinesterase (AChE) activity, and DNA damage were significantly changed in the AS compared with the RS (p<0.05). But the individual level bioindicators such as condition factor (CF), hepato-somatic index (HSI), and gonado-somatic index (GSI) were not significantly different from reference site (RS). These results may indicate impairments of ecological health by toxic chemicals and environmental conditions. Current this study is based on screening assessment of biochemical and individual level biomarkers and bioindicators, so further study is required additional biomarkers and population or community level bioindicators for more specific health assessments in agricultural areas.

Nutrient variations from swine manure to agricultural land

  • Won, Seunggun;You, Byung-Gu;Shim, Soomin;Ahmed, Naveed;Choi, Yoon-Seok;Ra, Changsix
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.5
    • /
    • pp.763-772
    • /
    • 2018
  • Objective: Swine manure in Korea is separated into solid and liquid phases which are composted separately and then applied on land. The nutrient accumulation in soil has been a big issue in Korea but the basic investigation about nutrient input on arable land has not been achieved in detail. Within the nutrient production from livestock at the national level, most values are calculated by multiplication of the number of animals with the excreta unit per animal. However, the actual amount of nutrients from swine manure may be totally different with the nutrients applied to soil since livestock breeding systems are not the same with each country. Methods: This study investigated 15 farms producing solid compost and 14 farms producing liquid compost. Composting for solid phase used the Turning+Aeration (TA) or Turning (T) only methods, while liquid phase aeration composting was achieved by continuous (CA), intermittent (IA), or no aeration (NA). Three scenarios were constructed for investigating solid compost: i) farm investigation, ii) reference study, and iii) theoretical P changes (${\Delta}P=0$), whereas an experiment for water evaporation was conducted for analyzing liquid compost. Results: In farm investigation, weight loss rates of 62% and 63% were obtained for TA and T, respectively, while evaporation rates for liquid compost were 8.75, 7.27, and $5.14L/m^2{\cdot}d$ for CA, IA, and NA, respectively. Farm investigation provided with the combined nutrient load (solid+liquid) of VS, N, and P of 117.6, 7.2, and $2.7kg/head{\cdot}yr$. Nutrient load calculated from farm investigation is about two times higher than the calculated with reference documents. Conclusion: The nutrient loading coefficients from one swine (solid+liquid) were (volatile solids, 0.79; nitrogen, 0.53; phosphorus, 0.71) with nutrient loss of 21%, 47%, and 29%, respectively. The nutrient count from livestock manure using the excretion unit has probably been overestimated without consideration of the nutrient loss.