• Title/Summary/Keyword: nighttime temperature

Search Result 171, Processing Time 0.023 seconds

A Study on Possibility of Improvement of MIR Brightness Temperature Bias Error of KOMPSAT-3A Using GEOKOMPSAT-2A (천리안2A호를 이용한 다목적실용위성3A호 중적외선 밝기 온도 편향오차 개선 가능성 연구)

  • Kim, HeeSeob
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.12
    • /
    • pp.977-985
    • /
    • 2020
  • KOMPSAT-3A launched in 2015 provides Middle InfraRed(MIR) images with 3.3~5.2㎛. Though the satellite provide high resolution images for estimating bright temperature of ground objects, it is different from existing satellites developed for natural science purposes. An atmospheric compensation process is essential in order to estimate the surface brightness temperature from a single channel MIR image of KOMPSAT-3A. However, even after the atmospheric compensation process, there is a brightness temperature error due to various factors. In this paper, we analyzed the cause of the brightness temperature estimation error by tracking signal flow from camera physical characteristics to image processing. Also, we study on possibility of improvement of MIR brightness temperature bias error of KOMPSAT-3A using GEOKOMPSAT-2A. After bias compensation of a real nighttime image with a large bias error, it was confirmed that the surface brightness temperature of KOMPSAT-3A and GEOKOMPSAT-2A have correlation. We expect that the GEOKOMPSAT-2A images will be helpful to improve MIR brightness temperature bias error of KOMPSAT-3A.

Effect of High Temperature and Water Management on Agronomic Characters in Rice (고온 및 고온기 물관리방법이 수도생육에 미치는 영향)

  • 이승필;김상경;이광석;최대웅;이상철
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.3
    • /
    • pp.195-200
    • /
    • 1990
  • These experiments were conducted to determine the effect of high temperature and water managements on growth and yield of rice. Shoot dry weight and percent of fresh roots were decreased when rice plant was exposed to high temperature, and also high temperature treatment decreased yield components of rice through spikelet number at meiotic, filled grain ratio and percent of fertility at heading, and 1,000 grain weight at ripening stage. Nitragen content of the rice varities was decreased by high temperature treatment regardless different growth stage, although Si content increased. Grain yield of rice varieties significantly decreased due to high temperature when rice plants were treated at heading stage followed by ripening stage. meiotic, young panicle initiation, maximum tillering and tillering stage in order. Effect of the continual submerging on temperature increased by 1.1$^{\circ}C$ at daytime and by 3.7$^{\circ}C$ at nighttime, but flowing water irrigation which can maintain optimum temperature reduced plant height and increased dry weight and percent of fresh roots. Flowing water irrigation showed higher yield by 4-8% compared to continual submerging method through increment of yield components such as spikelet number, filled grain ratio and 1,000-grain weight.

  • PDF

Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses (토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.215-224
    • /
    • 2009
  • A survey on the actual state of heating, cooling, ventilation, and air-flow and experimental measurement of temperature and humidity distribution in tomato greenhouse were performed to provide fundamental data required in the development of air-flow control technology. In single-span plastic houses, which account for most of 136 tomato greenhouses surveyed, roof windows, ventilation and air-flow fans were installed in a low rate, and installation specs of those facilities showed a very large deviation. There were no farms installed greenhouse cooling facilities. In the hot air heating system, which account for most of heating type, installation specs of hot air duct showed also a large deviation. The exhaust air temperature and wind speed in hot air duct also were measured to have a big difference depending on the distance from the heater. We are using the maximum difference as indicator to determine whether temperature distribution is uniform. However if the temperature slope is not identical in greenhouse, it can't represent the uniformity. We analyzed relation between the maximum difference and the uniformity of temperature and humidity distribution. The uniformity was calculated using the mean and standard deviation of data from 12 measuring points. They showed high correlation but were represented differently by linear in the daytime and quadratic in the nighttime. It could see that the uniformity of temperature and humidity distribution was much different according to greenhouse type and heating method. The installation guidelines for ventilation and air-flow fan, the spread of greenhouse cooling technology for year-round stable production, and improvement of air duct and heating system, etc. are needed.

A Study on the Change of the Urban Heat Island Structure in Busan Metropolitan Area, Korea (부산지역의 도시열섬 구조 변화에 관한 연구)

  • Kim, Hyunsu;Seok, Hyun-Bae;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1807-1820
    • /
    • 2014
  • The spatial and temporal changes of the annual mean urban heat island(UHI) intensity were investigated using near surface temperature data measured at 16 automatic weather systems(AWS) in Busan metropolitan area(BMA) during the 11-yr period, from 2000 to 2010. For nighttime, the annual mean UHI intensity at Dongnae(U1) in 2000 was weaker than it in 2010. However the change of the annual mean UHI intensity at Daeyeon(U2) during 11 years was different from it at U1. The annual frequency of the UHI intensity over $5^{\circ}C$ considerably increased at U2 and decreased at U1 during 11 years. The center of the UHI also spatially shifted southward with Daeyeon and Haeundae in BMA. It would be caused by the increase of urban area, population-density and transportation near U2 and by the decrease of them near U1. We found that the spatial and temporal differences of the UHI intensity have coincided with changes of land-use, population density and transportation in BMA.

Comparisons of Aircraft Observations and Simulation Results of Atmospheric CO2 over Coastal Basin Areas (연안 분지 지역 상공에서의 대기 중 CO2 시뮬레이션 결과와 항공 관측 사례 비교)

  • Park, Changhyoun;Lee, KwiOk;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.26 no.6
    • /
    • pp.741-750
    • /
    • 2017
  • A model coupling a meteorological predictive model and a vegetation photosynthesis and respiration model was used to simulate $CO_2$ concentrations over coastal basin areas, and modeling results were estimated with aircraft observations during a massive sampling campaign. Along with the flight tracks, the model captured the meteorological variables of potential temperature and wind speed with mean bias results of $0.8^{\circ}C$, and 0.2 m/s, respectively. These results were statistically robust, which allowed for further estimation of the model's performance for $CO_2$ simulations. Two high-resolution emission data sets were adopted to determine $CO_2$ concentrations, and the results show that the model underestimated by 1.8 ppm and 0.9 ppm at higher altitude over the study areas during daytime and nighttime, respectively, on average. Overall, it was concluded that the model's $CO_2$ performance was fairly good at higher altitude over the study areas during the study period.

High-resolution Simulation of Meteorological Fields over the Coastal Area with Urban Buildings (건물효과를 고려한 연안도시지역 고해상도 기상모델링)

  • Hwang, Mi-Kyoung;Kim, Yoo-Keun;Oh, In-Bo;Kang, Yoon-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.137-150
    • /
    • 2010
  • A meso-urban meteorological model (Urbanized MM5; uMM5) with urban canopy parameterization (UCP) was applied to the high-resolution simulation of meteorological fields in a complex coastal urban area and the assessment of urban impacts. Multi-scale simulations with the uMM5 in the innermost domain (1-km resolution) covering the Busan metropolitan region were performed during a typical sea breeze episode (4~8 August 2006) with detailed fine-resolution inputs (urban morphology, land-use/land-cover sub-grid distribution, and high-quality digital elevation model data sets). An additional simulation using the standard MM5 was also conducted to identify the effects of urban surface properties under urban meteorological conditions. Results showed that the uMM5 reproduced well the urban thermal and dynamic environment and captured well the observed feature of sea breeze. When comparison with simulations of the standard MM5, it was found that the uMM5 better reproduced urban impacts on temperature (especially at nighttime) and urban wind flows: roughness-induced deceleration and UHI (Urban Heat Island)-induced convergence.

Numerical Simulation Experiment on the Wind Ventilation Lane of the Local Circulation Winds in Daegu (대구지역의 국지적 대기순환풍의 환기경로에 관한 수치모의 실험)

  • Gu, Hyeon Suk;Kim, Hae Dong;Gang, Seong Dae
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.367-376
    • /
    • 2004
  • In urban area, thermal pollution associated with heat island phenomena is generally regarded to make urban life uncomfortable. To overcome this urban thermal pollution problem, urban planning with consideration of urban climate, represented by the concept of urban ventilation lane, is widely practiced in many countries. In this study, the prevailing wind ventilation lane of a local winds in Daegu during the warm climate season was investigated by using surface wind data and RAMS(Reasonal Atmospheric Model System) simulation. The domain of interest is the vicinity of Daegu metropolitan city(about 900 $km^{2})$ and its horizontal scale is about 30km. The simulations were conducted under the synoptic condition of late spring with the weak gradient wind and mostly clear sky. From the numerical simulations, the following two major conclusions were obtained: (1)The major wind passages of the local circulation wind generated by radiative cooling over the mountains(Mt. Palgong and Mt. Ap) are found. The winds blow down along the valley axis over the eastern part of the Daegu area as a gravity flow during nighttime. (2)After that time, the winds blow toward the western part of Daegu through the city center. As the result, the higher temperature region appears over the western part of Daegu metropolitan area.

A Numerical Experiments on the Atmospheric Circulation over a Complex Terrain around Coastal Area. Part II : (연안부근 복잡지형의 대기유동장 수치실험 II -부산광역지역에 대한 국지순환모형의 적용-)

  • 김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.151-158
    • /
    • 2000
  • Since Pusan metropolitanarea where is composed complex terrain is connected to sea the sea-land breeze circulation and the mountain-valley circulation are apt to form A regional scale circulation system is formed at a region which has complex terrain because of curves of its and affect to the dispersion and advection of air pollutants. LCM Local Circulation Model which a propriety was verified described that sea breeze and valley wind at the daytime and land breeze and mountain wind at the nighttime were well devellped over the Pusan metropolital area. Next for the investigation of accuracy of simulated results an observed value at Kae-Kum and Su-Young on the pusan metropolitan area were compared with it at those points. From the comparison of the temperature and horizontal velocity between the results of LCM and an observed values they have a similar trend of a diurnal variation. For the prediction of dispersion and transportation of air pollutants the wind field should be calculated with high accuracy. A numerical simulation using LCM can provide more accuracy results around Pusan metropolitan area.

  • PDF

Prediction of practically chargeable cold energy in an ice storage system (빙축열시스템의 실질적인 최대 축열 가능량 예측)

  • Lee, D.-Y.;Kang, B.H.;Kim, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

Analysis of Time Variations in Relative Humidity around a Water Area Using Bowen Ratio

  • Kim, Ki-Young;Kim, Kyu-Rang;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.23 no.10
    • /
    • pp.1731-1743
    • /
    • 2014
  • The time variations in relative humidity observed at the Gangjeong (Goryeong) Reservoir in the Nakdong River over a one-year period (September 2012-August 2013) were analyzed with the Bowen ratio. The thermal vertical scale of the reservoir was also evaluated following Yamamoto's method. The study's results showed that the relative humidity at the reservoir was higher than that of the Daegu Meteorological Observatory (inland) all year round. The difference was slightly larger at nighttime (17-20 %) than at daytime (13-15 %) in all seasons except summer. The quantitative order of latent heat flux was summer, spring, autumn, and winter. This finding signifies that the thermal vertical scale of the reservoir corresponds to that of a shallow lake. The Bowen ratio was smallest at midday of the summer season. In other words, the net radiation energy was converted more as latent heat flux than sensible heat flux during a higher temperature period.