• 제목/요약/키워드: nighttime temperature

검색결과 167건 처리시간 0.023초

Investigation of the Characteristic Nighttime Temperature of Potential Caves on Mars

  • Park, Nuri;Hong, Ik-Seon;Jung, Jongil
    • Journal of Astronomy and Space Sciences
    • /
    • 제39권4호
    • /
    • pp.141-144
    • /
    • 2022
  • By providing an environment where energetic particles and micrometeorites can not penetrate, caves on Mars may serve as a human shelter in future Mars explorations. More than 1,000 cave entrance candidates have been detected; however, their physical characteristics that can be utilized in detecting more candidates have not been explored in detail. In this paper, we explore the nighttime temperature of 100 cave entrance candidates and their surrounding areas to investigate 1) the nighttime temperature tendencies relative to their surrounding areas and 2) the extent of these temperature differences. We find that 79% of the cave entrance candidates exhibit higher temperatures than the surrounding areas, and 59% show a temperature difference over 20K, suggesting that the cave entrances may generally show higher temperatures than the surrounding areas during the nighttime.

TEMPORAL AND SPA TIAL VARIATION OF NIGHTTIME FISHING GROUND DERIVED FROM SATELLITE IMAGERY

  • Kim Sang-Woo;Jeong Hee-Dong;Suh Young-Sang;Go Woo Jin;Jang Lee-Hyun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.437-440
    • /
    • 2005
  • We examined the relationship between the 50m temperature estimated by remote sensing sea surface temperature (SST) and fishing ground (squid fishing ground) detected by nighttime visible channel defense meteorological satellite program (DMSP) I operational linescan system (OLS) images in the East/Japan Sea during 1993-2000. The results are as follows: The numbers of nighttime fishing boat were distributed the highest in October, and the lowest in April during this study. A nighttime fishing grounds have concentrated in the East Korea Warm Current region, coastal regions of Honshu Island, and Polar front region. Fishing grounds have distributed $11-18^{\circ}C$ of estimated 50m temperature from the satellite data. Relationship between estimated 50m temperature and the distributed fisheries boats showed that the north boundaries of fishing grounds have distributed the temperature of below $12^{\circ}C$ from 1996 to 2000 and that of $13-15^{\circ}C$ during 1993-1995 and 1997-1999. Stable fishing grounds appeared near the Korea/Tsushima Strait from January to March. The center of fishing grounds in spring (April-Jun) have moved to the northward than that in winter, and variations appeared largely in winter. In summer (July-September), center of fishing grounds have formed near the Uleung Island in the south east coast of Korea, and in autumn maximum fishing ground appeared in October, the fishing ground southward from November.

  • PDF

Terra/Aqua MODIS LST와 기온과의 상관성 분석: 한파 및 폭염 발생 기간을 중심으로 (Correlation Analysis between Terra/Aqua MODIS LST and Air Temperature: Mainly on the Occurrence Period of Heat and Cold Waves)

  • 정지훈;이용관;이지완;김성준
    • 한국지리정보학회지
    • /
    • 제22권4호
    • /
    • pp.197-214
    • /
    • 2019
  • 본 연구에서는 Terra/Aqua MODIS LST(Moderate Resolution Imaging Spectroradiometer Land Surface Temperature)의 Daytime, Nighttime 자료와 기상청 기상관측소 86개 지점에 대한 최고, 최저 및 평균기온을 이용하여 두 자료 사이의 상관성을 분석하고, 한파 및 폭염 발생 기간의 특성을 집중적으로 분석하였다. 모든 자료는 2008년부터 2018년까지 총 11년간 일별로 구축하였으며, Pearson 상관계수(Pearson correlation coefficient, R)와 평균제곱근오차(Root Mean Square Error, RMSE)를 이용하여 상관성 분석을 수행하였다. 시계열 분석 결과, 대상 기간 전체에서 기온과 MODIS LST 간의 변동 양상은 유사하였고, 최고 기온과 MODIS 자료의 R 0.9 이상, 평균기온과 최저 기온과는 0.8 이상으로 기온과 MODIS LST 사이의 상관성은 높은 것으로 나타났다. 특히, 최고 기온은 Terra MODIS LST Daytime과 정확도가 제일 높고, 최저 기온은 Terra MODIS LST Nighttime과 상관성이 제일 높은 것으로 분석되었다. 한파 기간에는 Terra/Aqua MODIS 모두 주간 자료보다 야간 자료의 상관성이 더 높은 것으로 분석되었으며, 특히 Terra MODIS LST Nighttime과의 상관성이 좋은 것으로 분석되었다. 폭염 기간에는 Aqua MODIS LST Daytime 자료가 가장 좋은 것으로 분석되었으나, 전체적인 R이 0.5보다 낮아 추후 활용을 위해서는 식생이나 토지이용, 고도 등 다른 요소를 활용한 추가 분석이 필요할 것으로 판단된다.

연구노트 산사면에서의 야간 기상요소의 특성에 관한 연구 (On Study on Chatacteristics of Nocturnal Meteorological Parameter at Mountain Slope)

  • 전병일;박재림;박현철
    • 한국환경과학회지
    • /
    • 제8권5호
    • /
    • pp.633-637
    • /
    • 1999
  • A series of meterological observation using automation weather station(AWS) carried out to investigate characteristics of nocturnal meteorological parameters for 16~17 June 1998 at Buljeongdong mountain slope, Kyungbuk. Dry temperature at valley was lower than mountain because of high lapse rate at valley, so the strong inversion layer occurrenced at mountain slope for nighttime. Contrary of dry temperature, relative humidity of valley was higher than mountain for nighttime. Wind speed at valley from sunset to next day morning was lower than mountain, but that of valley after sunrise was higher than mountain. Wind direction at valley for all observation time were southeasterlies(SE), that of mountain for nighttime were northeasterlies(NE) or northnorthwesterlies(NNW), and that of mountain after sunrise were irregular. Vapor pressure at valley for all observation time was higher mountain, particularly the difference was high for nighttime.

  • PDF

여름철 도시근린공원의 기온저감 효과 - 경기도 수원시 효원공원 - (Air Temperature Modification of an Urban Neighborhood Park in Summer - Hyowon Park, Suwon-si, Gyeonggi-do-)

  • 박수국;조상만;현철지;공학양;김승현;신영규
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.1057-1072
    • /
    • 2017
  • In order to investigate the effect of air temperature reduction on an urban neighborhood park, air temperature data from five inside locations (forest, pine tree, lawn, brick and pergola) depending on surface types and three outside locations (Suwon, Maetan and Kwonsun) depending on urban forms were collected during the summer 2016 and compared. The forest location had the lowest mean air temperature amongst all locations sampled, though the mean difference between this and the other four locations in the park was relatively small ($0.2-0.5^{\circ}C$). In the daytime, the greatest mean difference between the forest location and the two locations exposed to direct beam solar radiation (brick and lawn) was $0.5-0.8^{\circ}C$ (Max. $1.6-2.1^{\circ}C$). In the nighttime, the mean difference between the forest location and the other four locations in the park was small, though differences between the forest location and locations with grass cover (pine tree and lawn) reached a maximum of $0.9-1.7^{\circ}C$. Comparing air temperature between sunny and shaded locations, the shaded locations showed a maximum of $1.5^{\circ}C$ lower temperature in the daytime and $0.7^{\circ}C$ higher in the nighttime. Comparing the air temperature of the forest location with those of the residential (Kwonsun) and apartment (Maetan) locations, the mean air temperature difference was $0.8-1.0^{\circ}C$, higher than those measured between the forest location and the other park locations. The temperatures measured in the forest location were mean $0.9-1.3^{\circ}C$ (Max. $2.0-3.9^{\circ}C$) lower in the daytime than for the residential and apartment locations and mean $0.4-1.0^{\circ}C$ (Max. $1.3-3.1^{\circ}C$) lower in the nighttime. During the hottest period of each month, the difference was greater than the mean monthly differences, with temperatures in the residential and apartment locations mean $1.0-1.6^{\circ}C$ higher than those measured in the forest location. The effect of air temperature reduction on sampling locations within the park and a relatively high thermal environment on the urban sampling locations was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with a high sky view factor and surface types with high evapotranspiration potential (e.g. grass) showed the maximum air temperature reduction. In the urban areas outside the park, the low-rise building area, with a high sky view factor, showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, while in the nighttime the area with high-rise buildings, and hence a low sky view factor, showed high air temperature due to the effect of terrestrial (longwave) radiation emitted by surrounding high-rise building surfaces. The effect of air temperature reduction on the park with a high thermal environment in the city was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with high sky view factor and surface types (e.g., grass) with evapotranspiration effect showed maximum air temperature reduction. In the urban areas outside the park, the high sky view factor area (low-rise building area) showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, but in the nighttime the low sky view factor area (high-rise building area) showed high air temperature due to the effect of terrestrial (longwave) radiation emitted surrounding high-rise building surfaces.

야간 냉각율을 이용한 우포늪의 기온변화 완화효과 평가 (Evaluation of Mitigation Effect of Upo-Swamp on the Air temperature Variation with Nighttime Cooling Rate)

  • 박명희;김해동
    • 한국환경과학회지
    • /
    • 제20권3호
    • /
    • pp.309-319
    • /
    • 2011
  • In this study, we investigated the effects of Upo-swamp upon local thermal environment with nighttime cooling rate. To do this, we set up the AWS(Automatic Weather observation System) over the central part of Upo-swamp on the early October 2007. We conducted the study by comparing the AWS data with another weather data observed by several meteorological observations of the Korea Meteorological Administration located at the vicinity of Upo-swamp for one year. The air temperature of Upo-swamp was higher than that of the surrounding in cold-climate season. But it was opposite in warm-climate season. We confirmed that Upo-swamp roles to mitigate the daily and annual air temperature ranges. And the daily air temperature variation of Upo-swamp lagged behind the land one. This phenomenon represent that the heat reservoir capacity of Upo-swamp is much larger than that of the ground.

비 투과면 복사 냉각에 대한 복사 물성의 영향 예측 (Simulation of Radiative Property Effects on Radiant Cooling of Opaque Surface)

  • 변기홍
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.32-38
    • /
    • 2009
  • The effects of surface radiative properties on the radiant cooling of opaque surfaces under clear sky condition are studied. Two types of surfaces, one gray and the other selective, are compared. For the nighttime cooling, black surface gives the lowest plate temperature and on the other hand the ideal selective surface gives the highest temperature. The reverse is true when there is an insolation. Equivalent radiative heat transfer coefficient of radiant cooling without convection is about $1{\sim}7\;W/m^2-K$ for the range of values studied. The surface with black within the $6{\sim}13\;{\mu}m$ band else zero emissivity could be regarded as a black surface for the nighttime radiant cooling purposes. However, lower band limit of $4\;{\mu}m$ is preferred to $6\;{\mu}m$ for small insolation situations.

인공열이 도시경계층에 미치는 영향 - 경인지역을 중심으로 - (Impacts of anthropogenic heating on urban boundary layer in the Gyeong-In region)

  • 구해정;유영희
    • 환경영향평가
    • /
    • 제21권5호
    • /
    • pp.665-681
    • /
    • 2012
  • This study investigates the influence of anthropogenic heat (AH) release on urban boundary layer in the Gyeong-In region using the Weather Research and Forecasting model that includes the Seoul National University Urban Canopy Model (SNUUCM). The gridded AH emission data, which is estimated in the Gyeong-In region in 2002 based on the energy consumption statistics data, are implemented into the SNUUCM. The simulated air temperature and wind speed show good agreement with the observed ones particularly in terms of phase for 11 urban sites, but they are overestimated in the nighttime. It is found that the influence of AH release on air temperature is larger in the nighttime than in the daytime even though the AH intensity is larger in the daytime. As compared with the results with AH release and without AH release, the contribution of AH release on urban heat island intensity is large in the nighttime and in the morning. As the AH intensity increases, the water vapor mixing ratio decreases in the daytime but increases in the nighttime. The atmospheric boundary layer height increases greatly in the morning (0800 - 1100 LST) and midnight (0000 LST). These results indicate that AH release can have an impact on weather and air quality in urban areas.

남한의 겨울철 주.야간 체감 온도의 공간적 분포 특성 (Spatial Distribution Patterns of Winter Daytime and Nighttime Apparent Temperature in South Korea)

  • 최광용;강철성
    • 대한지리학회지
    • /
    • 제37권3호
    • /
    • pp.237-246
    • /
    • 2002
  • 본 연구는 최근 30년 (1971-2000) 최한월 (1월) 평균 기온 및 풍속, 일사량 자료를 토대로 산출한 겨울철 주.야간 바람냉각지수의 분포를 바탕으로 남한의 겨울철 생리 기후지역을 구분하였다. 그 결과. 겨울철 주.야간 바람냉각지수는 기온, 풍속, 일사량 등의 기후요소뿐 아니라 해발고도, 해륙풍, 지형, 해류 등의 기후인자의 영향을 받아 남한은 크게 5개의 생리기후지역으로 세분되었다: 주간 서늘-야간 추움 지역, 주간 쌀쌀-야간 추움 지역, 주간 쌀쌀-야간 매우추움 지역, 주.야간 모두 추움 지역, 주간 추움-야간 극도로 추움 지역, 특히, 남해안을 제외한 해안-도서지역은 계절풍 및 해륙풍의 영향으로 주간에는 싸늘함(Keen), 야간에는 매우 추움(Very Cold)의 체감도를 보였다. 또한, 해발고도가 높은 대관령 지역에서는 기온 감률 및 계절풍의 영향으로 주간에는 추움(Cold), 야간에는 극도로 추움(Extremely Cold)의 체감도를 보였다. 본 연구는 다양하게 나타나는 주야간 바람냉각지수의 분포를 바탕으로 남한의 겨울철 생리기후 지역을 구분함으로써 의복 및 건축 등의 단열에 관한 의사결정시 필요한 기초자료를 제공하고자 하였다.

도시 캐노피 층 기온과 상대습도의 일변화에 관한 수치 모의 (Numerical Simulations of Diurnal Variations of Air Temperature and Relative Humidity in the Urban Canopy Layer)

  • 박경주;한범순;진한결
    • 대기
    • /
    • 제31권3호
    • /
    • pp.295-309
    • /
    • 2021
  • Diurnal variations of air temperature and relative humidity in the Urban Canopy Layer (UCL) of the Seoul metropolitan area are examined using the Weather Research and Forecasting model coupled with the Seoul National University Urban Canopy Model. The canopy layer air temperature is higher than 2-m air temperature and exhibits a more rapid rise and an earlier peak in the daytime. These result from the multiple reflections of shortwave radiation and longwave radiation trapping due to the urban geometry. Because of the absence of vegetation in the UCL and the higher canopy layer air temperature, the canopy layer relative humidity is lower than 2-m relative humidity. Additional simulations with building height changes are conducted to examine the sensitivities of the canopy layer meteorological variables to the urban canyon aspect ratio. As the aspect ratio increases, net sensible heat flux entering the UCL increases (decreases) in the daytime (nighttime). However, the increase in the volume of the UCL reduces the magnitude of change rate of the canopy layer air temperature. As a result, the canopy layer air temperature generally decreases in the daytime and increases in the nighttime as the aspect ratio increases. The changes in the canopy layer relative humidity due to the aspect ratio change are largely determined by the canopy layer air temperature. As the aspect ratio increases, the canopy layer relative humidity is generally increased in the daytime and decreased in the nighttime, contrary to the canopy layer air temperature.