• Title/Summary/Keyword: nickel release

Search Result 20, Processing Time 0.028 seconds

A study on the release of nickel and chromium from simulated orthodontic appliances (교정장치로부터의 니켈과 크롬의 유리에 관한 연구)

  • Ryu, Jeong-Hyun;Oh, Soh-Taek;Kang, Kyung-Wha;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.351-358
    • /
    • 2003
  • Nickel and chromium are two major metals used in the alloys of most orthodontic appliances. But these metals are known to cause hypersensitivity, dermatitis, and asthma. In addition, a significant carcinogenic and mutagenic potential has been demonstrated for compounds containing these metals. The purpose of this study was to find out how much nickel and chromium was released from orthodontic appliances, and which factors would influence the release. The simulated orthodontic appliances were constructed for a half of a mandibular arch and incubated in $0.05\%$ NaCl solution at $37^{\circ}C$. Nickel and chromium release was quantified with an Inductively Coupled Plasma (ICP) spectroanalyzer. The results were as follows : 1. From simulated orthodontic appliances, nickel was released $9.83-70.0{\mu}g/day$ but the release of chromium was not detectable in Limit of 10ppb. 2. The amount of nickel release was significantly different between the types of appliances. 3. The galvanic condition increased the amount of nickel release, which was not statistically significant. 4. The sand blasting increased the amount of nickel release, which was also not statistically significant.

Properties of the Master Alloys for White Gold Products with Silicon Contents (백색금 합금용 모합금의 실리콘 함량에 따른 물성변화)

  • Song, Jeongho;Noh, Yunyoung;Lee, Hyeonwoo;Choi, Minkyoung;Song, Ohsung
    • Korean Journal of Materials Research
    • /
    • v.25 no.2
    • /
    • pp.90-94
    • /
    • 2015
  • We prepared 8 samples of non-silver and silver-added master alloys containing silicon to confirm the existence of nickel-silicides. We then prepared products made of 14K and 18K white gold by using the prepared master alloys containing 0.25, 0.35, and 0.50 wt% silicon to check for nickel release. We then employed the EN 1811 testing standard to investigate the nickel release of the white gold products, and we also confirmed the color of the white gold products with an UV-VIS-NIR-color meter. We observed $NiSi_x$ residue in all master alloys containing more than 0.50 wt% Si with EDS-nitric acid etching. For the white gold products, we could not confirm the existence of $NiSi_x$ through XRD after aqua-regia etching. In the EN 1811 test, only the white gold products with 0.25 wt% silicon master alloys successfully passed the nickel release regulations. Moreover, we confirmed that our white gold products showed excellent Lab indices as compared to those of commercial white gold ones, and the silver-added master alloys offered a larger L index. Our results indicate that employing 0.25 wt% silicon master alloys might be suitable for white gold products without nickel-silicide defects and nickel release problems.

Influence of MWCNTs on Fracture Toughness of MWCNTs/Nickel-Pitch Fiber/Epoxy Composites

  • Yim, Yoon-Ji;Park, Soo-Jin
    • Composites Research
    • /
    • v.28 no.6
    • /
    • pp.361-365
    • /
    • 2015
  • The influence of MWCNTs on fracture toughness properties of MWCNTs/Nickel-Pitch Fibers/epoxy composites (MWCNTs/Ni-PFs/epoxy) was investigated according to MWCNTs content. Nickel-Pitch-based carbon fibers (Ni-PFs) were prepared by electroless nickel-plating. The surface properties of Ni-PFs were determined by scanning electron microscopy (SEM) and X-ray photoelectron spectrometry (XPS). The fracture toughness of MWCNTs/Ni-PFs/epoxy was assessed by critical stress intensity factor ($K_{IC}$) and critical strain energy release rate ($G_{IC}$). From the results, it was found that the fracture toughness properties of MWCNTs/Ni-PFs/epoxy were enhanced with increasing MWCNTs content, whereas the value decreased above 5 wt.%. MWCNTs content. This was probably considered that the MWCNTs entangled with each other in epoxy due to an excess of MWCNTs.

METAL RELEASE FROM BRACKETS AND ARCHWIRES (BRACKET과 호선의 금속유리)

  • Park, Soo Byung;Rhee, Byung Tae
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.75-84
    • /
    • 1989
  • The purpose of this experiment was to measure the amounts of nickel and chromium released from a simulated orthodontic appliance in artificial saliva. Simulated mandibular half-arch orthodontic appliances were composed of American Iron and Steel Institute type 304 brackets, Permachrome, Elgiloy, Australian wire, T.M.A. and Nitinol. The amounts of nickel and chromium released from sample were measured with atomic absorption spectrophotometer after 3, 6, 9, 12, 15 days. The cumulative amounts of nickel released from Permachrome, Elgiloy, Australian wire and T.M.A. reached a plateau after 6 days. But the cumulative amounts of nickel released from Nitinol increased continuously. Significant amounts of both nickel and chromium were solubilized from the simulated orthodontic appliances into artificial saliva. After 15 days, total cumulative amounts of nickel were $152.15{\mu}g$, $150.27{\mu}g$, $134.74{\mu}g$, $114.67{\mu}g$ and $93.39{\mu}$ from the Elgiloy, Australian wire, Nitinol, Permachrome and T.M.A., respectively. Total cumulative amounts of chromium from Permachrome, Australian wire, Elgiloy, Nitinol and T.M.A. were $100.83{\mu}g$, $83.64{\mu}g$, $81.61{\mu}g$, $14.90{\mu}g$ and $12.43{\mu}g$, respectively. The result showed that nickel released from Elgiloy and chromium released from Permachrome were more than any others.

  • PDF

Corrosion release behavior of alloy 690 and its application in high-temperature water with Zn injection

  • Liao, Jiapeng;Hu, Yousen;Li, Jinggang;Jin, Desheng;Meng, Shuqi;Ruan, Tianming;Hu, Yisong;Zhang, Ziyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.984-990
    • /
    • 2022
  • Corrosion release behavior of Alloy 690 in high-temperature water was investigated under the conditions of injected Zn concentrations of 0 ppb, 10 ppb and 50 ppb. A protective oxide film composed of Zn(FexCr1-x)2O4 and Cr2O3 was formed with Zn injection, resulting in a better corrosion resistance. In comparison with the Zn-free condition, the corrosion release rate under the Zn-injection conditions was smaller. The corrosion release inhibiting factors were 1.7 and 1.9 under the conditions of 10 ppb and 50 ppb Zn-injection respectively. A foreseen application of the corrosion and corrosion release rates has been proposed and discussed.

Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Geun;Choi, Jung-Yun;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.172-177
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS. It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens ($10{\times}10{\times}1.5mm$) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS. The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION. The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.

Treatment of Pickling Wastewater from Electroless Nickel Plating by Soluble Electrode and Insoluble Electrode (용성 및 불용성전극을 이용한 무전해 니켈 도금 산세 폐액 처리)

  • Kim, Young-Shin;Jeon, Byeong-Han;Koo, Tai-Wan;Kim, Young-Hun;Cho, Soon-Haing
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In order to treat electrolysis nickel plating pickling wastewater to meet the effluent limit less than 3.0 mg/L, the electrolysis process by using soluble and insoluble electrode were studied. Electrolysis using soluble electrodes has a characteristic of easy elution from the electrode which the insoluble electrodes close not release metal from the electrode. For these reasons, there exist different characteristics in nickel removal efficiency, purity of nickel sludge. With this connection, the feasibility test were concluded to develop optimal conditions for the treatment of pickling wastewater electrolysis by using soluble electrodes, insoluble electrodes. Optimal condition of current density, pH were derived from the pickling wastewater using insoluble electrodes. It was concluded the highest removal efficiency of nickel at the operation condition of at pH 9, current density of $15mA/cm^2$. At these conditions, 95.3% purity of nickel sludge was achieved, iron content was 2.9%. Optimal condition when using soluble electrodes was derived current density of $10mA/cm^2$, pH 9. Purity of nickel sludge was 77.3%, iron content was 21.0%. 50.7% and 24.2% of operating cost can be saved by the use of soluble electrodes and the use of insoluble electrodes, respectively.

THE EFFECTS OF HEAT TREATMENT ON MECHANICAL PROPERTIES AND METAL RELEASE FROM HEAT-TREATED ORTHODONTIC ARCHWIRES (열처리한 교정용 호선의 기계적 성질과 금속유리에 대한 연구)

  • Choi, Chul Min;Rhee, Byung Tae
    • The korean journal of orthodontics
    • /
    • v.20 no.2
    • /
    • pp.381-390
    • /
    • 1990
  • The purpose of this study was to evaluate the effects of heat treatment on mechanical properties in $0.016^{{\prime}{\prime}}{\times}0.022^{{\prime}{\prime}}$ blue Elgiloy wires and to measure the amounts of nickel and chromium released from the wires in artificial saliva. Ultimate tensile strength, yield strength and elongation were measured with universal testing machine (Instron). and the amounts of nickel and chromium released from the sample were measured with atomic absorption spectrophotometer after one week immersion in the artificial saliva. Ultimate tensile strength and yield strength were progressively increased below $1000^{\circ}F$, but elongation was decreased. And the results were reversed above $1100^{\circ}F$. After heat treatment of the sample for 9 minutes at $1000^{\circ}F$, the maximum tensile strength and yield strength were $213.6kg/mm^2$, $140.1kg/mm^2$, respectively. Both tensile strength and yield strength were decreased progressively above $1100^{\circ}F$. Elongation was appeared the minimum value (8.6%) after heat treatment for 9 minutes and 12 minutes at $1000^{\circ}F$. There was a pronounced increase in nickel and chromium liberation with increasing time and temperature. The maximum amounts of nickel and chromium released form the sample were $4.947{\mu}m/cm^2$, $3.088{\mu}g/cm^2$, respectively after heat treatment for 12 minutes at $1300^{\circ}F$. Heat treatment is applied to orthodontic wires, especially cobalt-chromium alloys, for the purpose of stress-relievning and hardening. When the heat-treatment of orthodontic wires, the heating procedure should be well controlled in order to have no effect on corrosion resistance and mechanical properties.

  • PDF

Influence of shape and finishing on the corrosion of palladium-based dental alloys

  • Milheiro, Ana;Muris, Joris;Kleverlaan, Cornelis J.;Feilzer, Albert J.
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.56-61
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS. Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were used to cast two crowns and two disks. One of each was polished while the other was not. Two as-received alloys were also studied making a total of 5 specimens per alloy type. The specimens were submersed for 7 days in a lactic acid/sodium chloride solution (ISO standard 10271) and evaluated for surface structure characterization using SEM/EDAX. The solutions were quantitatively analysed for the presence of metal ions using ICP-MS and the results were statistically analysed with one-way ANOVA and a Tukey post-hoc test. RESULTS. Palladium is released from all specimens studied (range $0.06-7.08{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$), with the Pd-Cu alloy releasing the highest amounts. For both types of alloys, ion release of both disk and crown pairs were statistically different from the as-received alloy except for the Pd-Ag polished crown (P>.05). For both alloy type, disk-shaped pairs and unpolished specimens released the highest amounts of Pd ions (range $0.34-7.08{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$). Interestingly, in solutions submerged with cast alloys trace amounts of unexpected elements were measured. CONCLUSION. Shape and surface treatment influence ion release from dental alloys; polishing is a determinant factor. The release rate of cast and polished Pd alloys is between $0.06-0.69{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$, which is close to or exceeding the EU Nickel Directive 94/27/EC compensated for the molecular mass of Pd ($0.4{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$). The composition of the alloy does not represent the element release, therefore we recommend manufacturers to report element release after ISO standard corrosion tests beside the original composition.

A STUDY ON METAL RELEASE OF TIN ION-PLATED STAINLESS STEEL ORTHODONTIC APPLIANCES (TiN 피막 처리된 스테인레스강 교정용 장치물의 금속 유리에 대한 연구)

  • KIM, Myung-Sook;Sung, Jae-Hyun;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.43-54
    • /
    • 1995
  • This study was conducted to examine the metal release of TiN-plated stainless steel orthodontic appliances by constructing the simulated orthodontic appliances equivalent to maxillary half arch, by dividing into TiN-plated and TiN-nonplated Bloops and by dividing again these groups into welded and nonwelded groups. And then, the total quantity of metal release was obtained by measuring the amounts of both soluble and precipitated nickel and chromium after immersing in artificial saliva for 15 days. And then, the corrosion appearance of surface structure was observed by using SEM. The results of this study were summarized as follows. 1. The total amounts of released nickel and chromium showed that the TiN-plated group after welding(Group 1) was 25.46 ${\mu}g$, respectively, and 17.4 ${\mu}g$, while the TiN-nonplated group after welding(Group III) was 54.69 ${\mu}g$, respectively, and 85.27 ${\mu}g$. Then, the TiN-Plated group indicated less amounts of metal release(p<0.05). 2. The total amounts of the TiN-plated group without welding(Group II) was 0.05${\mu}g$ and 0.34${\mu}g$, respectively. Then, it was shown that the TiN-plated group without welding(Group II) indicated less metal release than that of the TiN-Plated group after welding(Group I)(p<0.01, p<0.05). 3. When observing their surface structure, there were a lot of precipitate and pitting corrosion in the groups with welding(Group I & III), when the TiN-plated group(Group I) showed lower level than the TiN-nonplated group(Group IIII). On the other hand, the groups without welding(Group II & IV) indicated a little of pitting corrosion. 4. In case of observation with the naked eyes, it was shown that there were significant disco1oration and corrosion in the groups with welding(Group I & III), while there was no any remarkable change in the groups without welding(Group II & IV).

  • PDF