• Title/Summary/Keyword: neutron source

Search Result 312, Processing Time 0.023 seconds

Neutronic and thermohydraulic blanket analysis for hybrid fusion-fission reactor during operation

  • Sergey V. Bedenko ;Igor O. Lutsik;Vadim V. Prikhodko ;Anton A. Matyushin ;Sergey D. Polozkov ;Vladimir M. Shmakov ;Dmitry G. Modestov ;Hector Rene Vega-Carrillo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2678-2686
    • /
    • 2023
  • This work demonstrates the results of full-scale numerical experiments of a hybrid thorium-containing fuel plant operating in a state close to critical due to a controlled source of D-T neutrons. The proposed facility represented a level of generated power (~10-100 MWt) in a small pilot. In this work, the simulation of the D-T neutron plasma source operation in conjunction with the facility blanket was performed. The fission of fuel nuclei and the formation of spatial-energy release were studied in this simulation, in pulsed and stationary modes of the facility operation. The optimization results of neutronic and fluid dynamics studies to level the emerging offsets of the radial energy formed in the volume of the facility multiplying part due to the pulsed operation of the D-T neutron plasma source were presented. The results will be useful in improving the power control-based subcriticality monitoring method in coupled systems of the "pulsed neutron source-subcritical fuel assembly" type.

SPECTRUM WEIGHTED RESPONSES OF SEVERAL DETECTORS IN MIXED FIELDS OF FAST AND THERMAL NEUTRONS

  • Kim, Sang In;Chang, Insu;Kim, Bong Hwan;Kim, Jang Lyul;Lee, Jung Il
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted response, the detector response functions of 17 neutron-measuring devices were numerically folded with each of the produced calibration neutron spectra through the in-house developed software 'K-SWR'. The detectors' response functions were taken from the IAEA Technical Reports Series No. 403 (TRS-403). The reference neutron fields of 21 kinds with 2 spectra groups with different proportions of thermal and fast neutrons have been produced using neutrons from the $^{241}Am$-Be sources held in a graphite pile, a bare $^{241}Am$-Be source, and a DT neutron generator. Fluence-average energy ($E_{ave}$) varied from 3.8 MeV to 16.9 MeV, and the ambient-dose-equivalent rate [$H^*(10)/h$] varied from 0.99 to 16.5 mSv/h.

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.

Anisotropy and Dose Equivalents Conversion Factors for the Unmoderated $^{252}Cf$ Source (비감속 $^{252}Cf$ 중성자선원에 대한 비등방성교정인자 및 선량당량환산인자)

  • Jeong, Deok-Yeon;Chang, Si-Young;Yoon, Suk-Chul;Kim, Jong-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Form the pure Maxwellian distribution(kT= 1.42MeV), the effects upon calibration factors of encapsulating a $^{252}Cf$ spontaneous fission neutron source were investigated to establish a standard neutron field in the Secondary Standard Dosimetry Laboratory at Korea Atomic Energy Research Institute(KAERI). A Monte Carlo code MCNP was used in simulating the encapsulation SR-Cf-100 and SR-Cf-1273 to be real conditions. The anisotropy(FI) and fluence-to-dose equivalents conversion factors$(H/{\Phi})$ were evaluated and compared with other results. As the results, the FI was determined to be 1.061 at ${\theta}=90^{\circ}$ with ${\pm}0.2%$ statistical error and the $(H/{\Phi})$ was evaluated to be $333.9 [pSv\;cm^2]\;with\;{\pm}0.5%$ statistical error, which is lower by 1.8% than that recommended by the ISO 8529. This means physically that the neutron spectrum of the unmoderated $^{252}Cf$ source in KAERI is a little more softened than that by the ISO.

  • PDF

Subcriticality Evaluation Using the Modified Neutron Source Multiplication Method (개선된 중성자 선원 증배법을 이용한 미임계도 평가)

  • Yoon, Seok-Kyun;Naing, Win;Kim, Myung-Hyun
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.155-163
    • /
    • 2007
  • To insure nuclear reactor safety, the reactivity of control rods should be calculated by measuring the criticality of reactor core and it is regularly performed during the annual physics test period. Also, the core criticality should be monitored during the start-up operation to avoid reactivity induced accidents. Many research works on control rod reactivity measurement and subcriticality measurement have been accomplished throughout the world for decades and recently a new method named "Modified Neutron Source Multiplication Method (MNSM)" was proposed in Japan which is known to be improved overcoming limitations of traditional Neutron Source Multiplication Method (NSM). In this study, MNSM was tested in calculation of subcriticalities and in evaluation of application validity using the educational reactor in Kyung Hee University, AGN-201. For this study, a revised nuclear data library and a neutron transport code system TRANSX - PARTISN were established. Correction factors for various control rod positions were produced using the k-effective values and the corresponding flux distributions and adjoint flux distributions. Experimental values of the core criticality were obtained using the neutron count rates of the BF3 proportional counters. The results showed that the expected reactivity worth of control rods by MNSM agreed well with the theoretical values and the correction factors contributed much for this purpose.

DEVELOPMENT OF LEAD SLOWING DOWN SPECTROMETER FOR ISOTOPIC FISSILE ASSAY

  • Lee, YongDeok;Park, Chang Je;Ahn, Sang Joon;Kim, Ho-Dong
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.837-846
    • /
    • 2014
  • A lead slowing down spectrometer (LSDS) is under development for analysis of isotopic fissile material contents in pyro-processed material, or spent fuel. Many current commercial fissile assay technologies have a limitation in accurate and direct assay of fissile content. However, LSDS is very sensitive in distinguishing fissile fission signals from each isotope. A neutron spectrum analysis was conducted in the spectrometer and the energy resolution was investigated from 0.1eV to 100keV. The spectrum was well shaped in the slowing down energy. The resolution was enough to obtain each fissile from 0.2eV to 1keV. The detector existence in the lead will disturb the source neutron spectrum. It causes a change in resolution and peak amplitude. The intense source neutron production was designed for ~E12 n's/sec to overcome spent fuel background. The detection sensitivity of U238 and Th232 fission chamber was investigated. The first and second layer detectors increase detection efficiency. Thorium also has a threshold property to detect the fast fission neutrons from fissile fission. However, the detection of Th232 is about 76% of that of U238. A linear detection model was set up over the slowing down neutron energy to obtain each fissile material content. The isotopic fissile assay using LSDS is applicable for the optimum design of spent fuel storage to maximize burnup credit and quality assurance of the recycled nuclear material for safety and economics. LSDS technology will contribute to the transparency and credibility of pyro-process using spent fuel, as internationally demanded.

Comparative optimization of Be/Zr(BH4)4 and Be/Be(BH4)2 as 252Cf source shielding assemblies: Effect on landmine detection by neutron backscattering technique

  • Elsheikh, Nassreldeen A.A.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2614-2624
    • /
    • 2022
  • Monte Carlo simulations were used to model a portable Neutron backscattering (NBT) sensor suitable for detecting plastic anti-personnel mines (APMs) buried in dry and moist soils. The model consists of a 100 MBq 252Cf source encapsulated in a neutron reflector/shield assembly and centered between two 3He detectors. Multi-parameter optimization was performed to investigate the efficiency of Be/Zr(BH4)4 and Be/Be(BH4)2 assemblies in terms of increasing the signal-to-background (S/B) ratio and reducing the total dose equivalent rate. The MCNP results showed that 2 cm Be/3 cm Zr(BH4)4 and 2 cm Be/3 cm Be(BH4)2 are the optimal configurations. However, due to portability requirements and abundance of Be, the 252Cf-2 cm Be/3 cm Be(BH4)2 NBT model was selected to scan the center of APM buried 3 cm deep in dry and moist soils. The selected NBT model has positively identified the APM with a S/B ratio of 886 for dry soils of 1 wt% hydrogen content and with S/B ratios of 615, 398, 86, and 12 for the moist soils containing 4, 6, 10, and 14 wt% hydrogen, respectively. The total dose equivalent rate reached 0.0031 mSv/h, suggesting a work load of 8 h/day for 806 days within the permissible annual dose limit of 20 mSv.

Characteristics of Transmutation Reactor Based on LAR Tokamak

  • Hong, B.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.431-431
    • /
    • 2012
  • A compact tokamak reactor concept as a 14 MeV neutron source is desirable from an economic viewpoint for a fusion-driven transmutation reactor. LAR (Low Aspect Ratio) tokamak allows a potential of high "see full txt" operation with high bootstrap current fractions and can be used for a compact fusion neutron source. For the optimal design of a reactor, a radial build of reactor components has to be determined by considering the plasma physics and engineering constraints which inter-relate various reactor components and are constrained to use ITER physics and technology. In a transmutation reactor, the blanket should produce enough tritium for tritium self-sufficiency and the neutron multiplication factor, keff should be less than 0.95 to maintain sub-criticality. The shield should provide sufficient protection for the superconducting toroidal field (TF) coil against radiation damage and heating effects of the fusion neutrons, fission neutrons, and secondary gammas. In this work, characteristics of transmutation reactor based on LAR tokamak is investigated by using the coupled system analysis.

  • PDF

INVESTIGATION OF THE CNS HOLE SHAPE AND A PROPOSED INSTALLATION METHOD FOR A VACUUM CHAMBER FOR THE HANARO REACTOR

  • Cho Yeong-Garp;Kim Young-Ki;Lee Kye-Hong;Choung Yun-Hang
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.455-458
    • /
    • 2006
  • The HANARO reactor has a vertical hole for a cold neutron source (CNS) in the heavy-water reflector tank, i.e., the CNS hole, which was considerably deformed during its welding to the horizontal cold neutron (CN) beam tube. This paper presents an investigation of the form of the CNS hole for the optimal design of the a vacuum chamber for the CNS. In addition, the installation method of the vacuum chamber into the CNS hole for minimizing the water thickness between the vacuum chamber and the nose of the CN beam tube is proposed.

NEUTRON FIELD OF THE EARTH, ORIGIN AND DYNAMICS

  • Kuzhevskij, B.M.;Nechaev, O.Yu.;Panasyuk, M.I.;Sigaeva, E.A.;Volodichev, N.N.;Zakharov, V.A.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.315-319
    • /
    • 2001
  • It is shown, that both cosmic radiation (external source) and natural radioactive gases (inner source) are sources of neutrons near the Earth crust. Correlation between the Earth crust dynamics and variations of thermal and slow neutron flux near the Earth surface is studied. It is shown, that variations of neutron flux near the Earth crust can be used for short-term predicting of natural hazards.

  • PDF