• Title/Summary/Keyword: neutron measurement

Search Result 252, Processing Time 0.028 seconds

Residual Stress Measurement on Welded Stainless Steel Specimen by Neutron Diffraction

  • Park, M.J.;Jang, D.Y.;Choi, H.D.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 2001
  • In this paper, the neutron diffraction is applied to the residual stress measurement on the 20mm-thick welded stainless steel plate ($100^{\circ}$$\times$100$mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$ is $95^{\circ}$and wavelength is 1.8340 ${\AA}$ . The Poisson ratio of 0.265 and elastic constant of 211 GPa are applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses are measured and the results show that the most of longitudinal stress is tensile and decreases, changing to compressive depending on the distance away from the welded spot. However, transverse component is changing from tensile to compressive along the depth of the welded point.

  • PDF

APPLICATION OF WHOLE BODY COUNTER TO NEUTRON DOSE ASSESSMENT IN CRITICALITY ACCIDENTS

  • Kurihara, O.;Tsujimura, N.;Takasaki, K.;Momose, T.;Maruo, Y.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.249-253
    • /
    • 2001
  • Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of $^{24}Na$ in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of $^{24}Na$ is approximately 50Bq for 10miniute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 $[(Bq^{24}Na/g^{23}Na)/mGy]$.

  • PDF

Investigation of Dose Distribution in Mixed Neutron-Gamma Field of Boron Neutron Capture Therapy using N-Isopropylacrylamide Gel

  • Bavarnegin, Elham;Khalafi, Hossein;Sadremomtaz, Alireza;Kasesaz, Yaser;Khajeali, Azim
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.189-195
    • /
    • 2017
  • Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM) polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT). In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the $R_2$ maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

Characteristics of Borosilicate Glass Incorporated Mortar for Improve Neutron Shielding Capability (중성자 차폐능 향상을 위한 붕규산유리 혼입 모르타르의 특성 분석)

  • Jang, Bo-Kil;Kim, Ji-Hyun;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.155-156
    • /
    • 2017
  • Borosilicate glass was incorporated to improve the neutron shielding capability of concrete. Boron is a typical neutron shielding material, and it is contained in borosilicate glass. However, borosilicate glass causes alkali-silica reaction, which damages the concrete. Therefore, studied to reduce the expansion due to alkali-silica reaction and to improve the neuton shielding capability. The measurement of the expansion due to the alkali-silica reaction was based on ASTM C 1260. Experimental results show that the expansion due to alkali-silica reaction is reduced when borosilicate glass powder incorporated. In addition, the neutron shielding capability was significantly improved when the fine aggregate replaced with borosilicate glass.

  • PDF

Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator (DT 중성자 발생기에 의한 중성자 검출기 반응도 조사)

  • Kim, Sang-In;Jang, In-Su;Kim, Jang-Lyul;Lee, Jung-Il;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • Several neutron measuring devices were tested under the neutron fields characterized with two distinct kinds of thermal and fast neutron spectrum. These neutron fields were constructed by the mixing of both thermal neutron fields and fast neutron fields. The thermal neutron field was constructed using by a graphite pile with eight AmBe neutron sources. The fast neutron field of 14 MeV was made by a DT neutron generator. In order to change the fraction of fast neutron fluence rate in each neutron fields, a neutron generator was placed in the thermal neutron field at 50 cm and 150 cm from the reference position. The polyethylene neutron collimator was used to make moderated 14 MeV neutron field. These neutron spectra were measured by using a Bonner sphere system with an LiI scintillator, and dosimetric quantities delivered to neutron surveymeters were determined from these measurement results.

Fissile Measurement in Various Types Using Nuclear Resonances

  • YongDeok Lee;Seong-Kyu Ahn
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.235-246
    • /
    • 2023
  • Neutron resonance transmission technique was applied for assaying isotopic fissile materials produced in the pyro-process. In each process of the pyro-process, a different composition of the fissile material is produced. Simulation was basically performed on 235U and 239Pu assay for TRU-RE product, hull waste, and uranium addition. The resonance energies were evaluated for uranium and plutonium in the simulation, and the linearity in the detection response was examined on the fissile content variation. The linear resonance energies were determined for the analysis of 235U and 239Pu on the different fissile materials. For enriched TRU-RE assay, the sample condition was suggested; The sample density, content, and thickness are the key factors to obtain accurate fissile content. The detection signal is discriminated for uranium and plutonium in neutron resonance technique. The transmitted signal for fissile resonance has a direct relation with the content of fissile. The simulation results indicated that the neutron resonance technique is promising to analyze 235U and 239Pu for various types of the pyro-process material. An accurate fissile assay will contribute toward safeguarding the pyro-processing system.

Neutron Fluence Evaluation for Reactor Pressure Vessel Using 3D Discrete Ordinates Transport Code RAPTOR-M3G (3차원 수송계산 코드(RAPTOR-M3G)를 이용한 원자로 압력용기 중성자 조사량 평가)

  • Maeng, Young Jae;Lim, Mi Joung;Kim, Byoung Chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.107-112
    • /
    • 2014
  • The Code of Federal Regulations, Title 10, Part 50, Appendix H requires surveillance program for reactor pressure vessel(RPV) that the peak neutron fluence at the end of the design life of the vessel will exceed $1.0E+17n/cm^2$ (E>1.0MeV). 2D/1D Synthesis method based on DORT 3.1 transport calculation code has been widely used to determine fast neutron(E>1.0MeV) fluence exposure to RPV in the beltline region. RAPTOR-M3G(RApid Parallel Transport Of Radiation-Multiple 3D Geometries) performing full 3D transport calculation was developed by Westinghouse and KRIST(Korea Reactor Integrity Surveillance Technology) and applied for the evaluations of In-Vessel and Ex-Vessel neutron dosimetry. The reaction rates from measurement and calculation were compared and the results show good agreements each other.

Response Analysis of the NE213-PSD System for Neutron Energy Spectreum Measurement (중성자 에너지 측정을 위한 NE213-PSD 장치의 감응 분석)

  • Lee, Kyung-Ju
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.367-372
    • /
    • 1992
  • In order to measure the energy spectrum of a radioactive neutron source, the pulse shape discrimination (PSD) system with organic scintillator, NE-213, was characterized by using some of the gamma ray sources and neutron source, Am-Be. The figure of merit of the rise time spectrum of AmBe source measured by this system was about 1.13. This value agrees well with the value of 1.3 which is measured for monoenergetic source, $^{12}C(d,\;n)^{13}N$. The results of present experiment for performance test of NE213-PSD system will provide the useful technique to measure the spectrum of neutron-gamma mixed field and to establish the neutron energy spectrum and flux density standards.

  • PDF

Development of an efficient method of radiation characteristic analysis using a portable simultaneous measurement system for neutron and gamma-ray

  • Jin, Dong-Sik;Hong, Yong-Ho;Kim, Hui-Gyeong;Kwak, Sang-Soo;Lee, Jae-Geun;Jung, Young-Suk
    • Analytical Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.69-81
    • /
    • 2022
  • The method of measuring and classifying the energy category of neutrons directly using raw data acquired through a CZT detector is not satisfactory, in terms of accuracy and efficiency, because of its poor energy resolution and low measurement efficiency. Moreover, this method of measuring and analyzing the characteristics of low-energy or low-activity gamma-ray sources might be not accurate and efficient in the case of neutrons because of various factors, such as the noise of the CZT detector itself and the influence of environmental radiation. We have therefore developed an efficient method of analyzing radiation characteristics using a neutron and gamma-ray analysis algorithm for the rapid and clear identification of the type, energy, and radioactivity of gamma-ray sources as well as the detection and classification of the energy category (fast or thermal neutrons) of neutron sources, employing raw data acquired through a CZT detector. The neutron analysis algorithm is based on the fact that in the energy-spectrum channel of 558.6 keV emitted in the nuclear reaction 113Cd + 1n → 114Cd + in the CZT detector, there is a notable difference in detection information between a CZT detector without a PE modulator and a CZT detector with a PE modulator, but there is no significant difference between the two detectors in other energy-spectrum channels. In addition, the gamma-ray analysis algorithm uses the difference in the detection information of the CZT detector between the unique characteristic energy-spectrum channel of a gamma-ray source and other channels. This efficient method of analyzing radiation characteristics is expected to be useful for the rapid radiation detection and accurate information collection on radiation sources, which are required to minimize radiation damage and manage accidents in national disaster situations, such as large-scale radioactivity leak accidents at nuclear power plants or nuclear material handling facilities.

VARIATION OF NEUTRON MODERATING POWER ON HDPE BY GAMMA RADIATION

  • Park, Kwang-June;Ju, June-Sik;Kang, Hee-Young;Shin, Hee-Sung;Kim, Ho-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • High density polyethylene (HDPE) is degraded due to a radiation-induced oxidation when it is used as a neutron moderator in a neutron counter for a nuclear material accounting of spent fuels. The HDPE exposed to the gamma-ray emitted from the fission products in a spent nuclear fuel results in a radiation-induced degradation which changes its original molecular structure to others. So a neutron moderating power variation of HDPE, irradiated by a gamma radiation, was investigated in this work. Five HDPE moderator structures were exposed to the gamma radiation emitted from a $^{60}Co$ source to a level of $10^5-10^9$ rad to compare their post-irradiation properties. As a result of the neutron measurement test with 5 irradiated HDPE structures and a neutron measuring system, it was confirmed that the neutron moderating power for the $10^5$ rad irradiated HDPE moderator revealed the largest decrease when the un-irradiated pure one was used as a reference. It implies that a neutron moderating power variation of HDPE is not directly proportional to the integrated gamma dose rate. To clarify the cause of these changes, some techniques such as a FTIR, an element analysis and a densitometry were employed. As a result of these analyses, it was confirmed that the molecular structure of the gamma irradiated HDPEs had partially changed to others, and the contents of hydrogen and oxygen had varied during the process of a radiation-induced degradation. The mechanism of these changes cannot be explained in detail at present, and thus need further study.