• Title/Summary/Keyword: network storage

Search Result 1,080, Processing Time 0.026 seconds

Development of an Environmental Monitoring and Warning System for Cold Storage Rouse Using Internet (인터넷을 이용한 저온저장고 환경감시 및 경보 시스템 개발)

  • Jeong, Hoon;Yun, Hong-Sun;Lee, Won-Og;Cho, Kwang-Hwan;Cho, Young-Kil;Park, Won-Kyu;Shin, Jae-Hun
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.28-31
    • /
    • 2003
  • For safe storage of agricultural products in the cold storage house, accurate monitoring of temperature, humidity and gas conditions is necessary. This study was conducted to develop an environmental monitoring and warning system for the cold storage house to improve safety of storage. The system developed in this study is able to monitor temperature, humidity and $CO_2$concentration in the storage house and to send alarm signal to the farmer by telephone and beeper when abnormal conditions have been occurred in the storage house. And the developed system use internet network so we can supervise storage conditions in the home. From the results of the performance test, it was found that the temperature and relative humidity can be controlled within the range of 0.5$^{\circ}C$ and $\pm$2 percent. And farmer's response was fair.

Beneficial effects of ton-bag and wire-steel pallet on postharvest handling of onion and the cost evaluation (톤백 및 와이어철제파렛트 이용에 따른 양파의 수확후관리 효율성 증대와 경제성 평가)

  • Kwon, Young-Deuk
    • Food Science and Preservation
    • /
    • v.24 no.7
    • /
    • pp.915-922
    • /
    • 2017
  • This study aimed in onion production by evaluating cost and labor efficiencies of onion storage methods using either a ton-bag or a wire-steel pallet. New methods using ton-bag and wire-steel pallets were developed and applied to postharvest tasks, such as harvest packaging, transportation, and storage. The storage parameters evaluated for their effect on the logistics of onion production were: working duration, working hours, and cost expenditure. The longitudinal tensile strength of the ton-bag developed in this study was 16% higher than that of the conventional ton-bag. The wire-steel pallet developed in this study had 10% more storage capacity in a low-temperature storage room, and its truck loading capacity was more than doubled compared to that of the conventional steel pallet. There was no difference in the wasting rate during bulk storage between the newly developed wire-steel pallet and the conventional steel pallet, for 500 kg of onions. However, the bulk storage of 1,000 kg of onions using the wire-steel pallet was not found to be suitable, because the wasting rate of onions stored using the wire-pallet was 3.7% higher than that of onions stored using a conventional steel pallet. The time and the total investing costs for the bulk method decreased by 50.1% and 46.1%, respectively, compared to those for conventional harvest. In the bulk storage using the wire-steel pallet, the total storage cost decreased by 28.8%. Thus, it is estimated that we could have saved 18.3 billion won if the wire-steel pallet method about 30% of the total onion production (1,298,749 M/T) in 2016.

A study developing control algorithm for Pumped-Storage Synchronous motor drive (양수발전소 동기전동기의 기동제어 알고리즘에 관한 연구)

  • Kang S.W.;Park S.H.;Kim J.M.;Lim I.H.;Ryu H.S.;Kim J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.467-471
    • /
    • 2003
  • The large synchronous motor for the pumped-storage plant(or SFC : Static Frequency Converter) has to be brought up to 100$\%$ rated speed and synchronized with the AC power network. Starting the motor from rest is achieved by switching current into the stator winding so that interaction between this stator current and the rotor flux will cause the correct direction of torque to be developed so that the motor turns in the required direction. Starting ranges of the synchronous motor are divided into three regions. The first region Is at standstill, the second that is called by the forced commutation is from standstill to 5-8$\%$ of rated speed, and the third, which is called by the natural commutation, is from 5-8$\%$ of rated speed to 100$\%$ rated speed. So this paper describes three regions of the control techniques of the pumped-storage synchronous motor drive.

  • PDF

Study on the Dynamic Synchronizing Control of An Islanded Microgrid (독립운전 마이크로그리드의 능동형 동기 투입 제어에 관한 연구)

  • Cho, Chang-Hee;Jeon, Jin-Hong;Kim, Jong-Yul;Kwon, Soon-Man;Kim, Sung-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1112-1121
    • /
    • 2011
  • A microgrid is an aggregation of multiple distributed generators (DGs) such as renewable energy sources, conventional generators, and energy storage systems that provide both electric power and thermal energy. Generally, a microgrid operates in parallel with the main grid. However, there are cases in which a microgrid operates in islanded mode, or in a disconnected state. Islanded microgrid can change its operational mode to grid-connected operation by reconnection to the grid, which is referred to as synchronization. Generally, a single machine simply synchronizes with the grid using a synchronizer. However, the synchronization of microgrid that operate with multiple DGs and loads cannot be controlled by a traditional synchronizer, but needs to control multiple generators and energy storage systems in a coordinated way. This is not a simple job, considering that a microgrid consists of various power electronics-based DGs as well as alternator-based generators that produce power together. This paper introduces the results of research examining an active synchronizing control system that consists of the network-based coordinated control of multiple DGs. Consequently, it provides the microgrid with a deterministic and reliable reconnection to the grid. The proposed method is verified by using the test cases with the experimental setup of a microgrid pilot plant.

Medical Image Storage System based on Computational Grid (계산 그리드 기반 의료영상 저장시스템)

  • Ahn, Byoung-Kyu;Park, Jae-Hyun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.10
    • /
    • pp.715-723
    • /
    • 2009
  • The use of medical imaging in hospitals is being gradually increased as it is of utmost importance in treatment and diagnosis of patients. With the drastic increase of the usage of medical imaging in hospitals per day necessitates more speedy and accurate systems for precise diagnosis and the treatment. Hence the modality and development of network infrastructure are also need to be improved day by day and this trend may be continued. Thus there is a great need improvement of PACS concerned. In this paper, by using the computational grid technology, we design a medical image storage system that improve the compression speed, and implement a prototype as a part of PACS. We also demonstrate the performance improvement from experimental results of the prototype.

A piecewise affine approximation of sigmoid activation functions in multi-layered perceptrons and a comparison with a quantization scheme (다중계층 퍼셉트론 내 Sigmoid 활성함수의 구간 선형 근사와 양자화 근사와의 비교)

  • 윤병문;신요안
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.2
    • /
    • pp.56-64
    • /
    • 1998
  • Multi-layered perceptrons that are a nonlinear neural network model, have been widely used for various applications mainly thanks to good function approximation capability for nonlinear fuctions. However, for digital hardware implementation of the multi-layere perceptrons, the quantization scheme using "look-up tables (LUTs)" is commonly employed to handle nonlinear signmoid activation functions in the neworks, and thus requires large amount of storage to prevent unacceptable quantization errors. This paper is concerned with a new effective methodology for digital hardware implementation of multi-layered perceptrons, and proposes a "piecewise affine approximation" method in which input domain is divided into (small number of) sub-intervals and nonlinear sigmoid function is linearly approximated within each sub-interval. Using the proposed method, we develop an expression and an error backpropagation type learning algorithm for a multi-layered perceptron, and compare the performance with the quantization method through Monte Carlo simulations on XOR problems. Simulation results show that, in terms of learning convergece, the proposed method with a small number of sub-intervals significantly outperforms the quantization method with a very large storage requirement. We expect from these results that the proposed method can be utilized in digital system implementation to significantly reduce the storage requirement, quantization error, and learning time of the quantization method.quantization method.

  • PDF

Adaptive Deadline-aware Scheme (ADAS) for Data Migration between Cloud and Fog Layers

  • Khalid, Adnan;Shahbaz, Muhammad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.3
    • /
    • pp.1002-1015
    • /
    • 2018
  • The advent of Internet of Things (IoT) and the evident inadequacy of Cloud networks concerning management of numerous end nodes have brought about a shift of paradigm giving birth to Fog computing. Fog computing is an extension of Cloud computing that extends Cloud resources at the edge of the network, closer to the user. Cloud computing has become one of the essential needs of people over the Internet but with the emerging concept of IoT, traditional Clouds seem inadequate. IoT entails extremely low latency and for that, the Cloud servers that are distant and unknown to the user appear to be unsuitable. With the help of Fog computing, the Fog devices installed would be closer to the user that will provide an immediate storage for the frequently needed data. This paper discusses data migration between different storage types especially between Cloud devices and then presents a mechanism to migrate data between Cloud and Fog Layer. We call this mechanism Adaptive Deadline-Aware Scheme (ADAS) for Data migration between Cloud and Fog. We will demonstrate that we can access and process latency sensitive "hot" data through the proposed ADAS more efficiently than with a traditional Cloud setup.

Evaluation of Dynamic Characteristics of Coarse Actuator and Design of a 2-Wire Fine Actuator for Small Form Factor ODD (초소형 광디스크 드라이브용 조동구동기의 동특성 평가 및 2-와이어 미세 구동기의 개발)

  • 박세준;이강녕;이동주;박노철;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.351-351
    • /
    • 2004
  • For greeting the era of ubiquitous network, data storage devices have been essentially attached to mobile data devices. As a result, the minimization of the storage device has arisen as major interests in the next generation data storage technology. So, there are many researches for the small form factor ODD. In this paper, we propose a pick up that consists of a linear VCM and 2-wire focusing actuator for a small form factor ODD. For the sake of checking performance of the coarse actuator, PID controller is designed. Experiment with controller and DSP board shows its propriety as a fine tracking actuator. And, 2-wire suspension actuator is designed in order to be contained in a coarse actuator and to satisfy the thickness of a PCMCIA type. Through the experiment of designed actuator, It verifies performance as a focusing actuator.

  • PDF

A Security-Enhanced Identity-Based Batch Provable Data Possession Scheme for Big Data Storage

  • Zhao, Jining;Xu, Chunxiang;Chen, Kefei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.9
    • /
    • pp.4576-4598
    • /
    • 2018
  • In big data age, flexible and affordable cloud storage service greatly enhances productivity for enterprises and individuals, but spontaneously has their outsourced data susceptible to integrity breaches. Provable Data Possession (PDP) as a critical technology, could enable data owners to efficiently verify cloud data integrity, without downloading entire copy. To address challenging integrity problem on multiple clouds for multiple owners, an identity-based batch PDP scheme was presented in ProvSec 2016, which attempted to eliminate public key certificate management issue and reduce computation overheads in a secure and batch method. In this paper, we firstly demonstrate this scheme is insecure so that any clouds who have outsourced data deleted or modified, could efficiently pass integrity verification, simply by utilizing two arbitrary block-tag pairs of one data owner. Specifically, malicious clouds are able to fabricate integrity proofs by 1) universally forging valid tags and 2) recovering data owners' private keys. Secondly, to enhance the security, we propose an improved scheme to withstand these attacks, and prove its security with CDH assumption under random oracle model. Finally, based on simulations and overheads analysis, our batch scheme demonstrates better efficiency compared to an identity based multi-cloud PDP with single owner effort.

Design of Korean Data Center for SDO

  • Choi, Seong-Hwan;Hwang, Eun-Mi;Cho, Kyung-Suk;Kim, Yeon-Han;Park, Young-Deuk;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.92.1-92.1
    • /
    • 2011
  • NASA launched Solar Dynamics Observatory (SDO) on February 2011 in order to understand the cause of solar activities and their influences on the Earth and the near-Earth space. KASI is constructing Korean Data Center for SDO based on the letter of agreement between KASI and NASA for space weather research. SDO produces about 1.5 TB a day and its raw data amounts to about 550 TB in a year. Stanford University has been already operating the data center for scientific raw data, but there is a limit to use its data for space weather research and space weather service in real time because of network environment. Korean Data Center for SDO will provide scientific data not only to Korean institutes but also to international space weather societies. KASI has designed the data transfer system by using GLORIAD in order to get higher performance and stability. After the first construction of data transfer system and storage system in this year, we will increase the storage capacity of the data center in phases considering new developments in a storage technology and drop of their prices.

  • PDF