• Title/Summary/Keyword: needle diameter

Search Result 177, Processing Time 0.031 seconds

Fine Needle Aspiration Cytology of Apocrine Carcinoma of the Breast - Two case report - (유방의 아포크린 암종의 세침흡인 세포학적 소견 - 2예 보고 -)

  • Jin, So-Young;Lee, Dong-Wha;Kwak, Jeong-Ja
    • The Korean Journal of Cytopathology
    • /
    • v.3 no.2
    • /
    • pp.67-74
    • /
    • 1992
  • Apocrine carcinoma is a rare form of breast malignancy and is composed of entirely or predominantly of apocrine type epithelial cells. Apocrine metaplastic cells are frequently noted in fine needle aspiration cytology(FNAC) of breast lesions, especially fibrocystic disease. These apocrine cells may occasionally be atypical, to make a diagnostic difficulty. Two cases of apocrine carcinoma of the breast diagnosed by FNAC are described, and differential cytologic points between apocrine metaplasia and apocrine carcinoma are discussed. The first case is a right breast mass of a 37-year-old woman for 20 days. The smears show many single or sheets of large cells on bloody background. Each cell has a large vesicular nuclei with multiple macronucleoli and abundant eosinophilic granular cytoplasm. The second case is a left breast mass of a 35-year-old woman for one month. The smears show similar findings as seen in the first one. Histopathologic findings of both cases are typical of apocrine carcinoma. Electron microscopy demonstrates variable numbers of large osmiophilic granules in diameter of $200\sim600nm$ in both cases.

  • PDF

Cytologic Features of Metastatic Retroperitoneal Seminoma - A Case Report - (후복막강에 전이한 정상피종의 세포학적 소견 - 1예 보고 -)

  • Kwon, Mi-Seon;Seo, Eun-Joo;Kim, Young-Shin;Kang, Chang-Suk;Shim, Sang-In
    • The Korean Journal of Cytopathology
    • /
    • v.6 no.1
    • /
    • pp.71-75
    • /
    • 1995
  • A fine needle aspiration biopsy specimen of a retroperitoneal mass in a 26-year-old man who had had an orchiectomy for seminoma was submitted for cytologic evaluation. Cytologic features of the specimen included uniform neoplastic cells found singly or in groups of several cells intermingled with lymphocytes in a characteristic foamy, lacelike background. These cells varied from 10 to 20 m in diameter. The nuclei were round to ovoid with fine or reticular chromatin and one or more prominent nucleoli. The poorly defined cytoplasm stained pale-blue or blue with cytoplasmic vacuoles. The cytologic appearance was consistent with seminoma. Documented reports of the cytological appearance of seminoma are rare. The diagnosis of primary gonadal seminoma by fine needle aspiration biopsy is probably not indicated since the treatment of a primary gonadal tumor, regardless of its histogenesis, requires surgical resection. However, fine needle aspiration biopsy is extremely valuable in the diagnosis of extragonadal as well as metastic and recurrent seminoma.

  • PDF

Electrical Breakdown Characteristics of Composite Insulation Composed of Epoxy Resins with N2, Dry-air in Non-uniform Field (불평등 전계 시 에폭시와 N2, dry-air 혼합절연체의 절연파괴특성)

  • Jung, Hae-Eun;Park, Seong-Hee;Kang, Seong-Hwa;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.462-463
    • /
    • 2007
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of composite insulation composed of epoxy resins with N2, air are studied in non-uniform field. The gap of needle to plane was 3mm, 5mm. The pressure of air, nitrogen was varied within the range of 0.1~0.6MPa. The thickness of a needle is 1mm and the curvature radius of the end of needle is 100um. The diameter of a plane made of the stainless steel is 50mm. As a result of the experiment, the breakdown voltage is increased about 3 times when epoxy resins is composited. The thickness of epoxy resins filled opposite to electrode concentrated electric field weakly influences on breakdown voltage.

  • PDF

Electrical Breakdown Characteristics of Epoxy and dry-air Composite Insulation (에폭시와 dry-air 혼합절연물의 절연파괴특성)

  • Jung, Hae-Eun;Oh, Jin-Heon;Lim, Jong-Nam;Kang, Seong-Hwa;Lim, Kee-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1389-1390
    • /
    • 2007
  • SF6 gas used widely as insulating component is rising as the environment problem. Electrical breakdown characteristics of epoxy and dry-air composite insulation was investigated on thickness of epoxy and pressure of dry-air under non-uniform field. The gap of needle to plane was from 2mm to 5mm. The pressure of dry-air was varied within the range of $0.1{\sim}0.6$ MPa. The thickness of a needle was 1mm and the curvature radius of a needle end was 100um. The diameter of a plane made of the stainless steel was 50mm. As a result of the experiment, breakdown voltage was increased about 3 times when epoxy was used. The impact that the thickness of epoxy influences on breakdown voltage was poor. It needs suitable thickness computation because the insulating gap of the gas is short as epoxy thickness increases.

  • PDF

Injection Flow Rate Improvement of Injectors for DME Common-rail Systems (DME 커먼레일 시스템을 위한 인젝터 분사 유량 개선)

  • Lee, G.S.;Shin, S.S.;Park, J.H.
    • Journal of ILASS-Korea
    • /
    • v.18 no.1
    • /
    • pp.55-60
    • /
    • 2013
  • In this study, injection flow rates and material of the solenoid sealing of the injectors were improved for the development of a di-methyl Ether(DME) common-rail system. To deliver the same amount of energy provided by injection pressure of diesel $P_{inj}$ = 160 MPa, the DME injectors need to have larger diameter of nozzle hole and more No. of hole at low injection pressure of $P_{inj}$ = 40~50 MPa. The simplified nozzle flow model, which takes account of nozzle geometry and injection condition, was employed in order to design the concept of a injector nozzle such as No. of hole, diameter of hole and diameter of needle seat, etc. Injection amount and rate were tested by diesel and DME test stand. As a result, the diameter of nozzle hole were enlarged by 0.25 mm. The diameter of the orifice in the high pressure line was increased by 1.0 mm to maintain hydraulic force in the nozzle. The material of the solenoid sealing was changed to HNBR, which was strong against the corrosive. Experimental results showed that the injection amount of the DME injector drastically increased by 191.9% comparison to that of diesel at $P_{inj}$ = 40 MPa.

Dielectric Characteristics of SF$_6$ Gas in Non-uniform Fields (불평등전계중에서 SF$_6$ 가스의 절연특성)

  • 이복희;전덕규;이경옥;안창환;이창준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.334-337
    • /
    • 1997
  • This paper describes dielectric characteristics of SF$_{6}$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The breakdown voltage-time (V-t) characteristics and breakdown voltage-gas pressure (V-p) characteristics and their characteristics are statistically investigated with positive and negative very fast transient overvoltages. The experiments were carried out using a needle-to-plane gap geometry in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation gas 22 mm, and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter.r.

  • PDF

Positioning of Partial Discharge in Insulation Oil (유중 부분방전의 위치 추정)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Seo, Dong-Hoan;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1861-1867
    • /
    • 2010
  • This paper described the positioning algorithm of partial discharge in insulation oil by acoustic method for the application of an on-line diagnosis in oil-immersed transformers. In the experiment, five AE sensors having the resonant frequency of 150 kHz were used, and a signal conditioner was fabricated. A needle-plane electrode system which is composed of a needle with a curvature radius of $10{\mu}m$ and a plane electrode with a diameter of 60 mm was installed to simulate partial discharges in insulation oil. From the time difference of arrival (TOA) of acoustic signal, we calculated the location of partial discharge in insulation oil. In the experiment, an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the experimental results, the positioning error of PD calculated by three AE sensors was within 4%.

  • PDF

Cytologic Diagnosis of Metastatic Hepatocellular Carcinoma by Aspiration Cytology of Sacrum (천골의 세침흡인검사로 진단된 전이성 간세포암종)

  • Shim, Jung-Weon;Ko, Ill-Hyang
    • The Korean Journal of Cytopathology
    • /
    • v.1 no.2
    • /
    • pp.179-184
    • /
    • 1990
  • Bone metastasis of hepatocellular carcinoma appears to be peculiar when clinical manifestation of liver disease is not apparent, and initial diagnosis of metastatic hepatocellular carcinoma by fine needle aspiration cytology is rarely obtained. We experienced a case of 45-year-old man with metastatic hepatocellular carcinoma in the sacrum, which was diagnosed by fine needle aspiration cytology. The intrahepatic mass, measuring 1.2 cm in diameter and kept unchanged in size for two years, was never proved to be hepatocellular carcinoma histopathologically. The aspirated neoplastic cells were mostly in sheets, showing abundant acidophilic cytoplasm and large, round, centrally located nuclei with single, prominent acidophilic mucleoli. In the cell block section, diagnosis of metastatic well-differentiated hepatocellular carcinoma was made without difficulty, and definite trabecular fashion with sinusoidal endothelial cell lining was found.

  • PDF

Dielectric Characteristics of $SF_6$ Gas in Inhomogeneous Field (불평등 전계중에서 $SF_6$가스의 절연특성)

  • Lee, Chang-Jun;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1870-1872
    • /
    • 1996
  • This paper presents dielectric characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The propose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane and two needles-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was 22 mm and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

Diagnostic Value of Ultrasound-Guided Fine Needle Aspiration Biopsy in Malignant Thyroid Nodules: Utility for Micronodules

  • Unal, Betul;Sezer, Cem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8613-8616
    • /
    • 2014
  • Background: The diagnostic approach to thyroid nodules involves ultrasound-guided fine needle aspiration biopsy (US-FNAB). We especially aimed to evaluate the contribution and the place of US-FNAB in preoperative evaluation of the malignant cases and draw attention to discordant cases diagnosed with papillary thyroid microcarcinoma (PTMC). Materials and Methods: A total of 276 cases were retrospectively reviewed who were subsequently diagnosed with a malignancy and who underwent US-FNAB. Results: Some 45 were found to have previously undergone the US-FNAB procedure. Of the patients in whom the surgical specimen was diagnosed with a malignancy, 21 (46.7%) were diagnosed as malignant or suspicious for malignancy, and 24 (53.3%) were concluded as benign or insufficient for diagnosis. Patients with the diagnosis of PTMC outnumbering the others was a striking finding (11 cases, 24%). Conclusions: We suggest performing repeat aspiration biopsy considering sampling errors in cases where inconsistency exists between clinical findings and cytological results in thyroid nodules smaller than 10 mm in diameter and with suspicious findings on ultrasonography.