• Title/Summary/Keyword: neck width

Search Result 197, Processing Time 1.176 seconds

A Study of Jeogori Design Pattern using the Pattern Analysis in the Books Entitled Hanbok Construction Focusing on the Women in 20's (성인여성 저고리 패턴을 활용한 개선된 저고리 패턴설계연구 - 20대 여성용 저고리를 중심으로 -)

  • Kim, Hyun-Ju;Chang, Min-jung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.4
    • /
    • pp.1-14
    • /
    • 2015
  • This study mainly analyzes that designing patterns of an adult women Jeogori that takes advantage of patterns from each textbooks and complements the disadvantages based on the analysis of data from the dress evaluation and comparison of materials. The modification of a size specification is needed for the standard body as an adjust of the length of Jogori between front and back, mediation for bust width between front and back, a movement for the based line of Sup and Godae. As a result, the suitable pattern according to the standard somatotype is as below. Jeogori Length of front is determined by the length of back which was measured from side neck point to bust point plus three centimeters, and give three and half centimeters more in front. This three and half centimeters is for the curved in front of your body due to the chest. Bust width of front and back have to show the differences of human body. Bust width of front is calculated as bust girth into quarters and add two centimeters. Bust width of back gives one centimeter behind the curve from the center line in order to reduce the floating phenomenon. So, the amount of center back line dart is one centimeter. Arm hole girth measures as dividing bust girth into four. Also, Goedae width has two methods to measure. First, divide bust girth into ten equal parts and subtract 0.5 centimeters from it. Second, measure neck girth and divide it by four. Sleeve length is equal to Hwajang minus bust width of front. Hand wrist calculates in using bust girth. Make bust girth into quarters and multiply three fifths. Side line measures as deducting from Jeogori length of back to Arm hole girth and multiply two thirds.

  • PDF

A Study on the Use of 10 MV X-Ray with Lead Absorber for Treatment of Head and Neck Tumors (10MV X선(線)을 이용(利用)한 경부(頸部) 방사선(放射線) 치료시(治療時) 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Kim, Hyung Sik;Kang, Wee Saing;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.25-28
    • /
    • 1983
  • Anterior and posterior parallel opposed field technique covering entire neck is desirable for elimination of junctional problems in treating upper neck with bilateral parallel opposed fields and lower neck with anterior one field. For good dose distribution in neck, dose in build-up region should be high for anterior field and should be low for posterior field. And so, with 10 MV X-ray, lead absorber was used for anterior field only. The adequate thickness of lead absorber, absorber-skin separation, width of central cord block for posterior field and anterior & posterior field weight were studied using film dosimery. The results are as follows. 1. As the thickness of the lead absorber increased the dose in build-up region increased. 2. As the absorber-skin separation decreased the dose in build-up region increased. 3. The adequate thickness of lead absorber was around 5.6mm. 4. The adequate absorber-skin separation was around 5cm. 5. The adequate posterior cord block width was 3cm. 6. 4:1 weighting for anterior and posterior field was adequate. And so with this technique, adequate dose distribution could be made as well as elimination junction problems.

  • PDF

A Study on Pattern Development of Men's Slim-fit Dress Shirt - Focus on the 25-35 aged men - (슬림핏 드레스 셔츠 패턴 개발에 관한 연구 - 25~35세 영 어덜트 층 남성을 중심으로 -)

  • Kim, Dong-Hyun;Jang, Jeong-Ah
    • Fashion & Textile Research Journal
    • /
    • v.15 no.6
    • /
    • pp.950-962
    • /
    • 2013
  • The purpose of this study was to develop the slim-fit dress shirt pattern. Among the published educational patterns, there were four patterns based on similar design and silhouette with slim-fit dress shirts. Then, the drafting method of those patternsBB were compared and analyzed. The subjects for wearing evaluation were three 20 to 39 aged average-sized men. After the wearing evaluation(5 Likert point scale), N pattern had been chosen as the final comparison pattern because it received the highest points. The slim-fit shirt pattern was developed based on the result of wearing evaluation. The foundation design were as following: shirt length (Stature/2-12), back length (Stature/4), armhole depth (Chest/4+1), width (Chest/4+3), Interscye; Back (Chest/6+5), Interscye; Front (Chest/6+4), width of the nape of neck (Neck/6+1=◎), height of the nape of neck (◎/3), of the front neck (◎-0.5), depth of the front neck(◎+1.5). After the wearing evaluation about researched pattern and N pattern, researched patternsBB scale points were bigger than N pattern and there were slight differences. The scale points for N patternsBB movement evaluation showed highest points on all contents. Therefore, the researched pattern is suitable for the original form of slim-fit dress shirt. The new dress shirt pattern reflected the slim-fit trend in the research expected to help educational environment and industrial site.

Characterization of Bi-directionally Oscillating Microflow and Flow Rectification Performance of Microdiffusers (마이크로 디퓨저 내의 양 방향 동적 유동과 펌프 구동 주파수에 따른 유동정류 특성 연구)

  • Lee, Yeong-Ho;Gang, Tae-Gu;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.291-299
    • /
    • 2002
  • This paper characterizes hi-directionally oscillating flow in planar microdiffusers in order to evaluate the frequency-dependent flow rectification performance of the microdiffusers. In the theoretical study, we analyze a hi-directionally oscillating flow in the planar microdiffuser. In the experimental study, we fabricate two different microdiffuser prototypes, having different neck widths of 100 ㎛ (D100) and 300 ㎛(D300), respectively. The experimental net flow rates are measured as 116.6 $\mu$ι/min. and 344.4 $\mu$ι/min. for D100 and D300, respectively. The experimental flow rate of D300 decreases at the oscillating flow frequencies higher than 90Hz, at which the net boundary layer thickness is reduced to the microdiffuser neck width. It is experimentally verified that the flow rectification performance and the net flow rate of the microdiffusers tend to decrease when the boundary layer thickness is smaller than the diffuser neck width.

A Study on the Silhouette of Men's Jackets by Changing Draft (특정부위(特定部位) 제도(制度)의 변화(變化)에 따른 남성(男性) Jacket의 실루엣 변화(變化) 비교(比較) 연구(硏究))

  • Hur, Dong-Jin;Kwak, Youn-Shin
    • Journal of Fashion Business
    • /
    • v.1 no.3
    • /
    • pp.95-102
    • /
    • 1997
  • This study is aimed for men's jacket draft not only to other style but also helping for men's jacket fits for trend by presenting the course to get a style we want by adding to the partial drafty changes in existing pattern of men's formal jacket selected two kinds of men's jacket style fit for 1997 S/S trend. In this 1997 S/S trend, the trend I of the characteristic formal jacket is a style slim expressed over the basic formal wear, and trend II of the characteristic casual jacket appears to women's wear that roundly expressed by collar line of V-zone returened back by the shoulder line of jacket made of a big diagonal wrinkled line of X-style in front centered around a button of center front line. In this study, it called that the existing traditional formal jacket of men is a A style of jacket and jacket style I, II is a jacket B, C style. Jacket A, B, C style, a distingtion in draft that added to make form an oblique wrinkled line of the X-shaped-making artificially to the front button line sharply distinguished by eyes will be come out by control of front neck width over the back neck width. According to this, we shall be found that place of front neck point is a cardinal point in draft that will be added any changes in a style of jacket.

  • PDF

Comparison Research on the Ease of Fitted Dress Shirt Patterns

  • Lee, Eunhae;Park, Sanghee
    • Journal of Fashion Business
    • /
    • v.18 no.3
    • /
    • pp.91-103
    • /
    • 2014
  • Shirts which have been a inner-wear in men's suit in the past, are being changed into an item that 20's men utilize to their individuality. Dress shirts have gotten out of its shape, becoming tight and slim with activity and fashion trend. In this study, two patterns of fitted dress shirts in a clothing construction text book were compared with the pattern of an apparel company with regard to the size tolerance and appearance silhouette; this comparison was performed through a fitting test and an appearance evaluation. According to the study, size tolerance of chest girth and waist girth were about 6~8cm and 10~18cm, respectively. Neck girth of the collar was tight in both the fitting test and appearance evaluation. Thus, the measurement value of the neck base girth had to be used for the collar pattern making. Moreover, approximately 35cm is a moderate size for the width on the upper arm in sleeve. Therefor the factors such as size tolerance of waist girth, height of sleeve cap, slim sleeve width and measurement value of neck base girth are being considered for the pattern making of fitted dress shirts.

Solitaire AB Stent-Assisted Coiling of Wide-Neck Micro Aneurysms

  • Li, Xue-dong;Qin, Jun;Xiao, Zhen-yong;Feng, Yi;Chen, Jia-kang
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.341-345
    • /
    • 2016
  • Objective : Solitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. We present our experience of coiling the micro-aneurysms of wide-neck with Solitaire AB stent assisting in a single center. Methods : Thirty-one Solitaire AB stents were used to treat via endovascular approach patients with 31 wide-neck micro aneurysms in a single center in China. Technical and clinical complications were recorded. Modified Rankin Scale was used to evaluate the patients' conditions via clinic and telephone follow-up. Results : The mean width of aneurysm sac was $2.30{\pm}0.42mm$, and the mean diameter of aneurysm neck was $2.83{\pm}.48mm$. Complete occlusion was achieved in 28 aneurysms (90.32%); neck remnant was seen in 3 aneurysms (9.68%). Technical and clinical complications related to the procedure were encountered in four patients (12.5%). Two patients died (6.25%). No patient had a permanent deficit. Conclusion : Solitaire AB stent was a safe and efficiency tool in assisting coiling of micro aneurysms with wide neck, but may be not suitable for a blaster-like one. Mid- and long-term follow-up will be required to elucidate the impact of the Solitaire AB stent on recanalization rate.

A Comparative Research on the Drafting Method of the Basic Basuc Bodice Patterns for Women (부인복 길원형 제도법에 관한 비교연구)

  • 구미지
    • Journal of the Korean Home Economics Association
    • /
    • v.32 no.2
    • /
    • pp.219-230
    • /
    • 1994
  • The purpose of this comparative research is to investigate the change of the drafting method of the basic patterns for women in Korea. Followings were the findings of this research: 1) The concept of the basic pattern could be found after the first of the 1950s and there was introduction of the many basic patterns. At first measurement couldn't be found. Gradually the personal body type could be expressed in the basic pattern through the practical measurements such as the width of highest bust level and the length of neck to bust. 2) Through the ages the changes of the basic patterns were between 1950,60s and 1980,90s distinctively at the back width back shoulder angle front and back shoulder height from biceps line back neck ratio(height/width) BP position at the biceps line the amounts of underarm dart underarm dart position from the biceps lines and front ease angle at BP line. 3) 4 Grouping the types of the basic pattern followings are their characters; 1st Munwha or Doreme style 2nd waist dart group 3rd underarm dart and rectangular front ease 4th the usage of many measurements like as front length upper bust girth etc.

  • PDF

Observation on Neck Form Changes Related to Aging in Men (Part III) -by the Somatometric Data and the Principal Component Ana]isis- (성인남자 목부위의 연령별 형태변화에 관한 연구(제3보) -직접계측치와 주성분 분석에 의한 해석-)

  • 이영숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.3
    • /
    • pp.463-470
    • /
    • 1995
  • Anthropological measurements concerning 29 items were made on 37 adult males aged from 20 to 60. Factor analysis was applied in all 36 items. The main results are as gallows 1. Neck girth and need base girth are smaller. in the elder croup than the gouger group. 2. These decrease occur in the frontal part of the neck. 3. Neck frontal width decreases with age, but side depth increases. 4. The back part of the body depth at the level of the shoulder increases with age. 5. For the factor analysis, the third factor is a factor of forms, the variations of which has a relation with age.

  • PDF

Usefulness of panoramic radiography in the diagnosis of osteoporosis (골다공증의 진단시 파노라마 방사선사진 유용성에 대한 연구)

  • Lee Byeong-Do;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.31 no.2
    • /
    • pp.67-71
    • /
    • 2001
  • Purpose: To assess the possibility of using panoramic indices as an indicator of jaw osteoporosis. Methods: Mandibular cortical width (MCW), degree of mandibular alveolar bone resorption (ABR) and morphology of mandibular inferior cortex (MIC) on panoramic radiograph were used as panoramic indices. These panoramic indices were compared with bone mineral density (BMD) of lumbar (L1-L4) and femoral neck measured by dual energy X-ray absorptiometry. We also compared MCW and ABR of young men with those of postmenopausal women. Results : There was a significant correlation between ABR and BMD of lumbar and femoral neck. And also significant correlation between MIC and BMD of lumbar and femoral neck. ANOVA test of BMD of lumbar and femoral neck showed significant differences according to morphologic classification of inferior cortex. There was significant difference in MCW and ABR between young men and postmenopausal women. Conclusion: Our results suggested that ABR and MIC on panoramic radiograph could be reliable in screening of osteoporosis.

  • PDF