• Title/Summary/Keyword: near-P.D-A

Search Result 275, Processing Time 0.029 seconds

A Study on Relationship between Near Work and Eye Fatigue (근업시간과 눈 피로도와의 관련성에 관한 연구)

  • Kim, Seok-Hwa;Kim, Hyojin
    • Journal of Digital Convergence
    • /
    • v.16 no.10
    • /
    • pp.531-536
    • /
    • 2018
  • The purpose of this study is to investigate eye fatigue and analyze symptoms of visual discomfort according to near work in young adults. A survey was conducted on 347 young adults aged 25.37 years (142 male and 205 female participants). The eye fatigue using Conlon questionnaire were surveyed and near work was investigated amounts of daily computer and smartphone. The score of eye fatigue was $13.65{\pm}7.11$ in less than 2 h/d, $16.83{\pm}6.77$ in 2~4 h/d, $18.88{\pm}6.60$ in 4~6 h/d, and $18.83{\pm}5.62$ in more than 6 hours(p=0.001). Also, headache(p<0.030), re-reading(p<0.036), and movement and fading(p<0.001) symptoms increased according to amounts of near work.

Photodissociation to Several Atomic Terms: Near-threshold Resonance for Production of O($^3$P) and O($^1$D) in OH Photodissociation

  • Lee, Seong Yeol
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.12
    • /
    • pp.1333-1336
    • /
    • 2001
  • A theoretical analysis is presented for the multichannel type resonance at energies above the dissociation threshold to O(1D) in the photodissociation of OH. Dissociations to both oxygenic terms O(3P) and O(1D) are treated. Total cross sections for producing these oxygen terms display asymmetric resonance due to the quantum interference resulting from complicated interplay of electronic states correlating to these two oxygenic terms. The branching ratios of O(3Pj, j = 0, 1, 2), and the vector properties of O(3Pj, j =0,1,2) and O(1D) display extensive changes near the threshold resonance as the result of the interactions among the electronic states correlated with O(3P) and O(1D).

Influence of Flow Conditions on a Boundary Layer to the Near-Wake of a Flat Plat (평판 경계층 유동조건이 근접후류에 미치는 영향)

  • Kim, D.H.;Chang, J.W.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1625-1630
    • /
    • 2004
  • An experimental study was carried out to investigate influence of flow conditions on a boundary layer to the near-wake of a flat plate. The flow condition in the vicinity of trailing edge that is influenced by upstream condition history is an essential factor that determines the physical characteristics of a near-wake. Various tripping wires were used to change boundary layer flow condition of upstream at the freestream velocity of 6.0 m/sec. Measurements of the boundary layer and near-wake according to the change of upstream conditions were conducted by using both I-probe(55P14 for boundary layer) and X-probe(55P61 for wake). Normalized velocity profiles of the boundary layer were shown the flow types such as laminar boundary layer, transition, and turbulent boundary layer at 0.95C from the leading edge. The velocity and turbulence intensity profiles of the near-wake for the case of laminar boundary layer at the flat plate surface exhibited a defect and a double peak showing perfect symmetry, respectively.

  • PDF

Comparison of Accommodative Function of Young Adults in their Twenties Wearing Monovision, Modified Monovision and Multifocal Soft Contact Lenses (모노비전, 변형된 모노비전, 멀티포컬 콘택트렌즈로 교정 시 20대 성인의 조절기능 비교)

  • Lee, A-Young;Kim, Jeong-Mee;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.117-124
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accommodative function of young adult in their 20s wearing monovision, modified monovision, and aspheric multifocal contact lenses at near task. Methods: Thirty young adults ($23.53{\pm}2.37years$) were fitted with monovision, modified monovision (the application of single vision contact lenses and center-near low addition aspheric multifocal contact lenses), and aspheric center-near multifocal contact lenses. After wearing these modalities during a week for adaption, and after watching visual display at computer for inducing accommodative pressure for 1 hour. The following assessments of accommodative function were made: contrast visual acuity (VA) at distance and near; accommodative response; near accommodative facility; and negative relative accommodation (NRA)/positive relative accommodation (PRA). All measurements were carried out binocularly. Results: In binocular distance VA with contrast of 10%, monovision was the worst among the four modalities (p=0.005). In accommodative response at 1 m (1.00 D), monovision was the lowest (p<0.05) and accommodative response at 40 cm (2.50 D) with monovision was lower than that of modified monovision and multifocal contact lens (p<0.05). We also found that there were no significant differences in accommodative facility and NRA/PRA among the four modalities. Conclusions: In young adult (20s), monovision with low add reduced the accommodative response at near task, however, modified monovision and multifocal lens with center-near type did not affect accommodative relaxation.

The Purchasing Trends of Purchase of Functional Progressive Addtions Lenses and Correlation Analysis of Binocular Function Value (기능성누진렌즈 구매고객의 구매동향 및 양안시기능값 상관성 분석)

  • Kim, Dong-min;Lee, Gi-yung;Park, Hyun-ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.255-261
    • /
    • 2015
  • Purpose: purchasing status and understanding trends of Functional progressive addtions lenses buyers', Correlation analysis of the Binocular Function value to determine ADD then can be apply sales and prescriptions. Methods: Years 2011 to 2014, 298 patients who were prescribed functional progressive lenses were analysed based on the prescription data and SPSS (Ver. 20.0) was treated using the statistics. Results: Results: The average age of our customers are $27.66{\pm}11.55$ years, average addition power is $+0.73{\pm}0.36D$, customers are using take a prescription of ADD $+0.75{\pm}0.28D$ was the highest 44.33% to 132 people. Near point of convergence of 276 people (92.62%) was mostly less than 10 cm, and near point of accommodation of 134 people (44.97%) was also below 10 cm, within 11~15 cm were 122 people (40.94%). Most of people were within normal range in terms of Near point of convergence and near point of accommodation, near point of accommodation tend to be longer than Near point of convergence. As you can see this result shows most of customers need extra help in their near point of accommodation instead of they are leak at it. FCC (Fused cross cylinder) check Value and ADD (addition power) tests showed that the value of a strong correlation (p=0.00), NPC and NPA were also p=0.001, the correlation of the NPC and ADD is p=0.003, In addition, NPA and ADD also showed a significant correlations (p=0.005). Near Point of Accommodation, negative relative accommodation, and positive relative accommodation are all significantly correlated (p=0.00). The short distance-related variables of the ADD which are NPC, NPA, Age, also appeared to side correlate significantly with each other. Conclusion: Binocular function values of the subjects were highly correlated with each other so precise examination is required. when Age young people are working at short distance, low ADD values was prescribed for solving discomfort. So, in the case of early presbyopia, accommodative insufficiency, or people feel fatigue when they often working at near although their accommodation function is normal, when functional progressive lenses are prescribed, expectation of this should be exactly notified.

Relationship between Dominant Eye and Refractive Error in Myopic Anisometropia (굴절부등근시환자에서의 우세안과 굴절이상의 관계)

  • Lee, Seung-Ki;Kim, Sungjin;Lyu, In Jeong
    • Journal of The Korean Ophthalmological Society
    • /
    • v.60 no.5
    • /
    • pp.470-473
    • /
    • 2019
  • Purpose: To investigate the relationship between dominant eye and refractive error in patients with myopic anisometropia. Methods: This study population consisted of myopes less than 15 years old who were followed up for anisometropia defined as interocular difference of spherical equivalent (SE) ≥1.0 diopter (D). All patients underwent the hole-in-the-card test at far and near to determine ocular dominance. The data were analyzed for statistical significance using Fisher's exact test. Results: A total of 102 eyes in 51 patients were analyzed. The mean age of the patients was 10.4 ± 1.4 years and 54.9% were male. The mean SE was -2.97 ± 1.95 D in the right eye and -3.02 ± 1.92 D in the left eye. The right eye was the dominant eye in 43.1% and 37.3% at distance and near, respectively. The agreement of dominancy between distant and near was 82.4%. The near dominant eyes showed statistically significant accordance with more myopic eyes (p = 0.009). On the other hand, there was no statistically significant relationship between more myopic eyes and distant dominant eyes (p = 0.09). Conclusions: The near dominant eye was more myopic eye in patients with myopic anisometropia. This was considered to be related with the lag of accommodation in dominant eye with near distance.

Valence Band Photoemission Study of the Kondo Insulator CeNiSn

  • Kang, J.S.;Olson, C.G.;Ouki, Y.
    • Journal of Magnetics
    • /
    • v.2 no.4
    • /
    • pp.111-115
    • /
    • 1997
  • The electronic structure of the Kondo insulator CeNiSn has been investigated by using photoemission spectroscopy. A satellite feature is observed in the valence band spectrum about 6 eV below the Ni 3d main peak, indicating a strong Ni 3d Coulomb correlation in CeNiSn. The Ce 4f partial spectral weight exhibits three peak structures, including one due to the 4f1\longrightarrow4f0 transition, another near EF, and the other which overlaps the Ni 3d main peak. We interpret the peak near EF as reflecting mainly the Ce 4f/Sn 5p hybridization, whereas that around the ni 3d main peak as reflecting both the Ce 4f/Ni 3d and Ce 5d/Ni 3d hybridization. Yield measurements across the 4d\longrightarrow4f threshold indicate the Ce valence to be close to 3+. The prominent Fermi edge suggests a metallic ground state in CeNiSn.

  • PDF

Effect of Visual Sensory Improvement by Amblyopia Treatment on Improvement of Ocular Functions (약시 치료에 의한 시감각 개선이 안기능 향상에 미치는 효과)

  • Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.551-555
    • /
    • 2014
  • Purpose: This study is to investigate if the improvement of visual sensory (VS) by amblyopia treatment affects the ocular functions in refractive errors, accommodative errors and phoria at distance and near. Methods: 10 subjects (17 eyes, mean age of $10.7{\pm}2.9$ years) who treated amblyopia completely, were participated for this study. Refractive errors, accommodative errors, and distance and near phoria were compared between before and after treatments of amblyopia. Refractive errors and accommodative errors at 40 cm were measured using openfield auto-refractor (NVision-5001, Shin Nippon, Japan) and using monocular estimated method (MEM) respectively. Phoria was determined at 3 m for distance and at 40 cm for near using Howell phoria card, cover test or Maddox rod. Results: Mean corrected visual acuity (CVA) significantly increased from $0.46{\pm}0.11$ (decimal notation) for before amblyopia treatment to a level of $1.03{\pm}0.13$ for after amblyopia treatment (p < 0.001). For spherical refractive error, hyperopia significantly decreased from $+2.29{\pm}0.86D$ to a level of $+1.1{\pm}2.38D$ (p < 0.05) but astigmatism did not significantly change; $-1.80{\pm}1.41D$ for before treatment and $-1.65{\pm}1.30D$D for after treatment (p > 0.05). Accommodative error significantly decreased from accommodative lag of $+1.1{\pm}0.75D$ to a level of $+0.5{\pm}0.59D$ (accommodative lag) (p < 0.05). Distance phoria significantly changed from eso $2.9{\pm}6.17PD$ (prism diopters) to a level of eso $0.2{\pm}3.49PD$ (p < 0.05), and near phoria also significantly changed from eso $0.4{\pm}2.32PD$ to level of exo $2{\pm}4.9PD$ (p < 0.05). There was a high correlation (r = 0.88, p < 0.001) between improvement of visual acuity and decrease of accommodative lag. Conclusions: Hyperopic refractive error decreased with improvement of CVA or VS by amblyopia treatment. And the improvement of VS by amblyopia treatment also improved accommodative error, and changed phoria coupled with accommodation.

Comparison of Accommodative System according to the Material and Font Size of Near Visual Media (근거리 시각매체의 재질과 글자크기에 따른 조절시스템의 비교)

  • Ha, Na-Ri;Kim, Chang-Jin;Jung, Su A;Choi, Eun Jung;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • Purpose: This study was conducted to compare and analyze the accommodative system (accommodative response and accommodative lag) according to the material and font size of near visual media that we often encounter in daily life. Methods: Forty adult men and women aged 20 to 30 who not had specific ocular diseases and refractive surgery experience were examined to measure and compare the accommodative response according to the material of near visual media (print paper, newspaper, magazine, the I-Phone, LCD monitor) and font size (6, 8, 10, 12) by using both eyes open-view auto-refractometer. Results: The accommodative stimulus was $2.28{\pm}0.11D$ and the accommodative response was $1.66{\pm}0.30D$. The accommodative lag namely the difference between accommodative stimulus and accommodative response was $0.62{\pm}0.28D$. The accommodative response according to material of visual media using LCD monitor was $1.35{\pm}0.26D$ (p=0.00) and using the I-Phone was $1.55{\pm}0.25D$ (p=0.04). Both of them were statistically significant lower. The accommodative lag using LCD monitor was $0.93{\pm}0.24D$ (p=0.00) and using the I-Phone was $0.73{\pm}0.25D$ (p=0.04) and they were statistically significant higher. The accommodative response and accommodative lag according to font size were not statistically significant (p>0.05). Conclusions: During near working, the accommodative system was more affected by material than font size of visual media. Especially, visual media of non-luminous material (print paper, newspaper, magazine) are considered fewer burdens on eyes than luminous material (I-Phone, LCD monitor) in terms of accommodative system.

Infrared Scanning Near-Field Optical Microscopy (IR-SNOM) Below the Diffraction Limit

  • Sanghera, J.S.;Aggarwal, I.D.;Cricenti, A.;Generossi, R.;Luce, M.;Perfetti, P.;Margoritondo, G.;Tolk, N.;Piston, D.
    • Ceramist
    • /
    • v.10 no.3
    • /
    • pp.55-66
    • /
    • 2007
  • Infrared Scanning Near-field Optical Microscopy (IR-SNOM) is an extremely powerful analytical instrument since it combines IR spectroscopy's high chemical specificity with SNOM's high spatial resolution. In order to do this in the infrared, specialty chalcogenide glass fibers were fabricated and their ends tapered to generate SNOM probes. The fiber tips were installed in a modified near field microscope and both inorganic and biological samples illuminated with the tunable output from a free-electron laser located at Vanderbilt University. Both topographical and IR spectral images were simultaneously recorded with a resolution of ${\sim}50\;nm$ and ${\sim}100\;nm$, respectively. Unique spectroscopic features were identified in all samples, with spectral images exhibiting resolutions of up to ${\lambda}/60$, or at least 30 times better than the diffraction limited lens-based microscopes. We believe that IR-SNOM can provide a very powerful insight into some of the most important bio-medical research topics.

  • PDF