• Title/Summary/Keyword: near IR

Search Result 355, Processing Time 0.022 seconds

Recovering the Colors of Objects from Multiple Near-IR Images

  • Kim, Ari;Oh, In-Hoo;Kim, Hong-Suk;Park, Seung-Ok;Park, Youngsik
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.102-111
    • /
    • 2015
  • This paper proposes an algorithm for recovering the colors of objects from multiple near-infrared (near-IR) images. The International Commission on Illumination (CIE) color coordinates of objects are recovered from a series of gray images captured under multiple spectral near-IR illuminations using polynomial regression. The feasibility of the proposed algorithm is tested experimentally by using 24 color patches of the Color Rendition Chart. The experimental apparatus is composed of a monochrome digital camera without an IR cut-off filter and a custom-designed LED illuminator emitting multiple spectral near-IR illuminations, with peak wavelengths near the red edge of the visible band, namely at 700, 740, 780, and 860 nm. The average color difference between the original and the recovered colors for all 24 patches was found to be 11.1. However, if some particular patches with high value are disregarded, the average color difference is reduced to 4.2, and this value is within the acceptability tolerance for complex image on the display.

IR Absorption Property in Nano-thick Ir-inserted Nickel Silicides (이리듐이 첨가된 니켈실리사이드의 적외선 흡수 특성)

  • Yoon, Kijeong;Song, Ohsung;Han, Jeungjo
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.11
    • /
    • pp.755-761
    • /
    • 2008
  • We fabricated thermally evaporated 10 nm-Ni/1 nm-Ir/(poly)Si films to investigate the energy saving property of silicides formed by rapid thermal annealing (RTA) at the temperature range of $300{\sim}1200^{\circ}C$ for 40 seconds. Moreover, we fabricated 100 nm-thick ITO/(poly)Si films with an rf-sputter as references. A transmission electron microscope (TEM) and an X-ray diffractometer were used to determine cross-sectional microstructure and phase changes. A UV-VIS-NIR and FT-IR (Fourier transform infrared spectroscopy) were employed for near-IR and middle-IR absorbance. Through TEM analysis, we confirmed 20~65 nm-thick silicide layers formed on the single and polycrystalline silicon substrates. Ir-inserted nickel silicide on single crystalline substrate showed almost the same absorbance in near IR region as well as ITO, but Ir-inserted nickel silicide on polycrystalline substrate, which had the uniform absorbance in specific region, showed better absorbance in near IR region than ITO. The Ir-inserted nickel silicide on polycrystalline substrate particularly showed better absorbance in middle IR region than ITO. The results imply that nano-thick Ir-inserted nickel silicides may have excellent absorbing capacity in near-IR and middle-IR region.

Monitoring photo-polymerization reaction using near-IR spectroscopic technique (Near-IR 분광법을 이용한 광 경화 중합반응 관찰)

  • Chung, Soo-Chung;Hong, Jin-Who;Yu, Jeong-A
    • Analytical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.341-345
    • /
    • 2002
  • The extent of UV-curing photo-polymerization reaction was monitored by near-IR spectroscopic method. Acrylates containing quaternary ammonium salts and Darocur 1173 were used as reactive monomer and a photo initiator, respectively. The extent of photo-polymerization reaction was obtained from the conversion ratio of acrylate double bond calculated from the intensities of measured bands at 1615 nm and at 2105 nm. Near-IR spectroscopic methods can be an useful tool for the monitoring of the progress of photo-polymerization.

Defining the $M_{BH}-sigma_*$ relation using the uniformly measured stellar velocity dispersions in the near-IR

  • Kang, Wol-Rang;Woo, Jong-Hak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.62.2-62.2
    • /
    • 2011
  • The correlation between black hole mass and stellar velocity dispersion provides an important clue on the black hole growth and galaxy evolution. In the case of AGN, however, it is extremely difficult to measure stellar velocity dispersions in the optical since AGN continuum dilutes stellar absorption features. In contrast, stellar velocity dispersions of active galaxies can be measured in the near-IR, where AGN-to-star flux ratio is much smaller. Expecting that more stellar velocity dispersion measurements will be available using future near-IR facilities, it is crucial to test whether the stellar velocity dispersions measured from the near-IR spectra are consistent with those measured from the optical spectra. For a sample of 35 nearby galaxies, for which optical stellar velocity dispersion measurements and dynamical black hole masses are available, we obtained high quality H-band spectra, using the TripleSpec at the Palomar 5-m Telescope, in order to calibrate the stellar velocity dispersions and define the $M_{BH}-sigma_*$ relation in the near-IR. Based on the spatially resolved kinematics, we correct for the rotation component and determine the luminosity-weighted stellar velocity dispersion of the spheroid component in each galaxy. In this presentation, we will show the comparison between optical and near-IR stellar velocity dispersion measurements and define the $M_{BH}-sigma_*$ relation based on uniformly measured stellar velocity dispersion in the near-IR.

  • PDF

IR Absorption Property in Nano-thick Nickel Silicides (나노급 두께 니켈실리사이드의 적외선 흡수 특성)

  • Yoon, Ki-Jeong;Han, Jeung-Jo;Song, Oh-Sung
    • Korean Journal of Materials Research
    • /
    • v.17 no.6
    • /
    • pp.323-330
    • /
    • 2007
  • We fabricated thermaly evaporated 10 nmNi/(poly)Si films to investigate the energy saving property of silicides formed by rapid thermal annealing (RTA) at the temperature of $300{\sim}1200^{\circ}C$ for 40 seconds. Moreover, we fabricated $10{\sim}50$ nm-thick ITO/Si films with a rf-sputter as reference films. A four-point tester was used to investigate the sheet resistance. A transmission electron microscope (TEM) and an X-ray diffractometer were used for the determination of cross sectional microstructure and phase changes. A UV-VISNIR and FT-IR (Fourier transform infrared rays spectroscopy) were employed for near-IR and middle-IR absorbance. Through TEM analysis, we confirmed $20{\sim}70nm-thick$ silicide layers formed on the single and polycrystalline silicon substrates. Nickel silicides and ITO films on the single silicon substrates showed almost similar absorbance in near-IR region, while nickel silicides on polycrystalline silicon substrate showed superior absorbance above 850 nm near-IR region to ITO films. Nickel silicide on polycrystalline substrate also showed better absorbance in middle IR region than ITO. Our result implies that nano-thick nickel silicides may have exellent absorbing capacity in near-IR and middle-IR region.

Analysis of Trace Trichlorosilane in High Purity Silicon Tetrachloride by Near-IR Spectroscopy (근적외선 분광법을 이용한 고순도 SiCI4 중의 미량 불순물 SiHCI3의 분석)

  • Park, Chan-Jo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.87-90
    • /
    • 2002
  • The content of $SiHCl_3$ as a trace impurity in $SiCl_4$ was analyzed by Near IR spectrophotometer with optical fiber. The strong absorption bands of $5345{\sim}5116cm^{-1}$ and $4848{\sim}4349cm^{-1}$ were used for analysis of $SiHCl_3$, and the detection limit of impurity $SiCl_3$ was appeared to be 0.005 % in the spectrum. The quantitative analysis by Near IR spectrophotometry showed the analytical possibility of trace impurity in $SiCl_4$ without sample pre-treatment not only in the laboratory but also in the field.

Calibrating the stellar velocity dispersion in near-IR

  • Kang, Wol-Rang;Woo, Jong-Hak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2011
  • The correlation between black hole mass and galaxy stellar velocity dispersion gives an important clue on the black hole growth and galaxy evolution. In the case of AGN, however, it is extremely difficult to measure stellar velocity dispersions in the optical spectra since AGN continuum dilutes stellar absorption features. In contrast, stellar velocity dispersions of active galaxies can be measured in the near-IR, where AGN-to-star flux ratio is much smaller, particularly with the laser-guide-star adaptive optics. However, it is crucial to test whether the stellar velocity dispersion measured from the near-IR spectra is consistent with that measured from the optical spectra. Using the TripleSpec at the Palomar 5-m Telescope, we obtained high quality spectra ranging from 1 to 2.4 micron for a sample of 35 nearby galaxies, for which dynamical black hole masses and optical stellar velocity dispersion measurements are available, in order to calibrate the stellar velocity dispersion in the near-IR. In this poster, we present the initial results based on 10 galaxies, with the stellar velocity dispersion measured in the H-band.

  • PDF

Infrared Scanning Near-Field Optical Microscopy (IR-SNOM) Below the Diffraction Limit

  • Sanghera, J.S.;Aggarwal, I.D.;Cricenti, A.;Generossi, R.;Luce, M.;Perfetti, P.;Margoritondo, G.;Tolk, N.;Piston, D.
    • Ceramist
    • /
    • v.10 no.3
    • /
    • pp.55-66
    • /
    • 2007
  • Infrared Scanning Near-field Optical Microscopy (IR-SNOM) is an extremely powerful analytical instrument since it combines IR spectroscopy's high chemical specificity with SNOM's high spatial resolution. In order to do this in the infrared, specialty chalcogenide glass fibers were fabricated and their ends tapered to generate SNOM probes. The fiber tips were installed in a modified near field microscope and both inorganic and biological samples illuminated with the tunable output from a free-electron laser located at Vanderbilt University. Both topographical and IR spectral images were simultaneously recorded with a resolution of ${\sim}50\;nm$ and ${\sim}100\;nm$, respectively. Unique spectroscopic features were identified in all samples, with spectral images exhibiting resolutions of up to ${\lambda}/60$, or at least 30 times better than the diffraction limited lens-based microscopes. We believe that IR-SNOM can provide a very powerful insight into some of the most important bio-medical research topics.

  • PDF

Near-IR Polarimetric Study of N159/160 Star-Forming Regions

  • Kim, Jaeyeong;Pak, Soojong;Jeong, Woong-Seob;Park, Won-Kee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.79.1-79.1
    • /
    • 2014
  • We present the result of near-infrared (near-IR) imaging polarimetry of star-forming regions in the Large Magellanic Cloud (LMC). We compiled near-IR photometric and polarimetric data of N159/160 regions. The photometric and polarimetric data were simultaneously obtained in J, H, and Ks bands using SIRPOL, an imaging polarimeter of the InfraRed Survey Facility (IRSF), in 2007 February. We measured Stokes parameters of point-like sources to derive their degree of polarization and polarization position angles. In this poster, we present polarization properties of these star-forming regions. We also discuss the polarization structure in these regions compared with mid-infrared dust emission structure from the Spitzer SAGE survey.

  • PDF

Color Image Acquired by the Multispectral Near-IR LED Lights (다중 파장 근적외선 LED조명에 의한 컬러영상 획득)

  • Kim, Ari;Kim, Hong-Suk;Park, Youngsik;Park, Seung-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.1-10
    • /
    • 2016
  • A system which provides multispectral near-IR and visible gray images of objects is constructed and an algorithm is derived to acquire a natural color image of objects from the gray images. A color image of 24 color patches is obtained by recovering their CIE (International Commission on Illumination) LAB color coordinates $L^*$, $a^*$, $b^*$ from their gray images using the algorithm based on polynomial regression. The system is composed of a custom-designed LED illuminator emitting multispectral near-IR illuminations, fluorescent lamps and a monochrome digital camera. Color reproducibility of the algorithm is estimated in CIELAB color difference ${\Delta}E^*_{ab}$. And as a result, if yellow and magenta color patches with around 10 ${\Delta}E^*_{ab}$ are disregarded, the average ${\Delta}E^*_{ab}$ is 2.9, and this value is within the acceptability tolerance for quality evaluation for digital color complex image.