• Title/Summary/Keyword: naturally cooling

검색결과 36건 처리시간 0.02초

엔진 냉각 시스템 개선에 관한 연구 (A Study on Improvement of Engine Cooling System)

  • 김문헌;오병욱
    • 한국자동차공학회논문집
    • /
    • 제2권2호
    • /
    • pp.103-116
    • /
    • 1994
  • In this study the behavior of engine cooling loss and overall heat transfer coefficient were studied experimentally using naturally aspirated engine and turbo charged engine. Using turbo charging, heat dissipation was increased because of the density of the mixture was increased with increment of inlet air flow rate. Therefore, cooling loss of turbo charged engine is larger than naturally aspirated engine. As taking the measurement of surface temperature of combustion chamber, gas heat transfer coefficient was calculated and found that it has greatly affected to overall heat transfer coefficient. The empirical formula of overall heat transfer coefficient established in order to predict of engine cooling loss and express only as a function of mean piston velocity.

  • PDF

ZnO 박막의 RF 마그네트론 스퍼터 증착 중 미리 가열된 기판의 자연냉각 효과 (The Natural Cooling Effects of Pre-heated Substrate during RF Magnetron Sputter Deposition of ZnO)

  • 박성현;이능헌
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.905-909
    • /
    • 2007
  • Crystalline and micro-structural characteristics of ZnO thin films which were deposited on p-Si(100) with cooling naturally down of pre-heated substrate during RF magnetron sputter deposition, were investigated by XRD and SEM in this paper. The film which was prepared on the substrate which was pre-heated to $400^{\circ}C$ before deposition and then cooled naturally down during deposition, showed the most outstanding c-axis preferred orientation. The ZnO thin film having the best crystalline result were applied to SMR type FBAR device and resonance properties of the device were investigated by network analyzer. It showed that resonance frequency was 2.05 GHz, return loss was -30.64 dB, quality factor was 3169 and electromechanical coupling factor was 0.4 %. This deposition method would be very useful for application of surface acoustic wave filter or film bulk acoustic wave resonator.

저압 에어포그 시스템을 설치한 온실의 냉방효율 (Cooling Efficiency of Low Pressure Compressed Air Fogging System in Naturally Ventilated Greenhouses)

  • 남상운;김영식;성인모;고기혁
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.49-55
    • /
    • 2012
  • In order to derive the efficient utilization of low pressure compressed air fogging system, cooling efficiencies with control types were analyzed through cooling experiments in tomato greenhouses. The control types were set up with temperature control, humidity control, temperature and humidity control, and time control. It showed that the cooling effects were 0.7 to $3.3^{\circ}C$ on average and maximum of 4.3 to $7.0^{\circ}C$, the humidification effects were 3.5 to 13.5 % on average and maximum of 14.3 to 24.4 %. Both the cooling and humidification effect were the highest in the time control method. The cooling efficiency of the air fogging system was not high with 8.3 to 27.3 % on average. However, the cooling efficiency of 24.6 to 27.3 % which appears from the time control is similar to the cooling efficiency of high pressure fogging system experimented in Japan. The air fogging system is operated by low pressure, but its efficiency is similar to high pressure. We think because it uses compressed air. From this point of view, we suggest that the air fogging system can get the cooling efficiency of similar levels to that of high pressure fogging system and it will have an advantage from clogging problem of nozzle etc.

SF6 가스를 충전한 변압기의 자연순환 냉각시스템의 성능시뮬레이션 (Performance Simulation of Natural Circulating Cooling System of SF6 Gas Charged Transformer)

  • 최영돈;허창수;김진봉
    • 설비공학논문집
    • /
    • 제6권1호
    • /
    • pp.54-65
    • /
    • 1994
  • Performance of naturally circulating cooling system of $SF_6$ gas charged transformer was simulated and the variations of gas flow rate, maximum coil temperature, gas temperature and cooling air temperature were investigated with respect to the height of radiator, interplates distance and heat generation rate at core. The results show that the height of radiator most significantly affects the performance of natural circulating cooling system of transformer.

  • PDF

RF 스퍼터를 이용하여 ZnO 증착 시 기판의 냉각율이 박막의 c-축 배향성에 미치는 영향 (Effects of Cooling Rate of Pre-heated Substrate on C-Axis Orientation of ZnO Prepared by RF Sputter Deposition)

  • 박성현;이능헌
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.560-564
    • /
    • 2006
  • ZnO thin films were prepared by RF magnetron sputter deposition on p-Si(100) wafer with various cooling rates of substrate temperature such as the substrates were pre-heated to $400^{\circ}C$ before the deposition and then cooled down naturally or slowly to $300^{\circ}C,\;200^{\circ}C,\;100^{\circ}C$, and R.T. by the temperature controller during the deposition. Crystalline and micro-structural characteristics of the films were investigated by XRD and SEM. ZnO films which cooled down naturally or slowly by the temperature controller during the deposition, especially the film were deposited with cooling down from $400^{\circ}C\;to\;200^{\circ}C$ slowly. showed the most outstanding c-axis preferred orientation.

Investigating risk of overheating for school buildings under extreme hot weather conditions

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.277-287
    • /
    • 2017
  • This study examines the risk of overheating of a school building, under extreme hot weather conditions, in 14 locations in the United Kingdom using the overheating criteria defined in Building Bulletin 101 (BB101). The building was modelled as naturally ventilated, mechanically ventilated and in mixed mode and was simulated both for the current and the projected weather conditions of the 2050s. Under the current weather conditions, results of the simulations show that when naturally ventilated, the school building fulfils the BB101 criteria only in the areas of Edinburgh and Glasgow. In the simulations of the building as mechanically ventilated and in mixed mode, mechanical cooling was provided in order for the building to comply with the overheating criteria. A comparison of the required cooling loads between the two scenarios shows that application of mixed mode ventilation results in less cooling loads.

RF 스퍼터링 법에 의한 ZnO 박막의 결정성과 기판의 냉각속도 (The crystalline characteristics of ZnO deposited on various cooling rates by RF sputter)

  • 박성현;이능헌;지승한;전석환;이상훈;추순남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.257-258
    • /
    • 2006
  • ZnO thin films were prepared by RF magnetron sputter deposition on p-Si(100) wafer with various cooling rates of substrate temperature such as the substrates were pre-heated to $400^{\circ}C$ before the deposition and then cooled down naturally or slowly to $300^{\circ}C$, $200^{\circ}C$, $100^{\circ}C$, and R.T., by the temperature controller during the deposition. The crystall me and micro-structural characteristics of the films were investigated by XRD and SEM ZnO films which cooled down naturally or slowly by temperature controller during deposition, especially the film were deposited with cooling down from $400^{\circ}C$ to $200^{\circ}C$ slowly, showed the most outstanding c-axis preferred orientation.

  • PDF

Thermal Conductivity Analysis of Amorphous Silicon Formed by Natural Cooling: A Molecular-dynamics Study

  • Lee, Byoung Min
    • 한국세라믹학회지
    • /
    • 제53권3호
    • /
    • pp.295-300
    • /
    • 2016
  • To investigate the thermal conductivity and the structural properties of naturally cooled excimer-laser annealed Si, molecular-dynamics (MD) simulations have been performed. The thermal conductivity of crystalline Si (c-Si) was measured by direct method at 1000 K. Steady-state heat flow was measured using a stationary temperature profile; significant deviations from Fourier's law were not observed. Reliable processes for measuring the thermal conductivity of c-Si were presented. A natural cooling process to admit heat flow from molten Si (l-Si) to c-Si was performed using an MD cell with a size of $48.9{\times}48.9{\times}97.8{\AA}^3$. During the cooling process, the temperature of the bottom $10{\AA}$ of the MD cell was controlled at 300 K. The results suggest that the natural cooling system described the static structural property of amorphous Si (a-Si) well.

LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구 (A Basic Study on the District Cooling System of LNG Cold Thermal Energy)

  • 김청균
    • 한국가스학회지
    • /
    • 제7권4호
    • /
    • pp.36-43
    • /
    • 2003
  • 본 논문에서는 LNG 냉열 에너지를 활용한 지역 냉방 시스템 가능성에 대해 고찰하고자 한다. 액상의 LNG는 기상의 가스로 변환하는 과정에서 많은 냉열 에너지를 발생한다. 최근에 빙축열을 이용한 건물의 냉방 시스템 구축과 심층수를 이용한 지역 냉방 시스템이 도심지의 기존 사무실 건물이나 대규모 건물의 냉방장치로 도입되고 있는 상황이다. LNG의 냉열 에너지는 기존의 냉매에 의존한 개별 냉방 시스템을 대체하는 새로운 냉열 에너지 공정으로 쾌적한 공간을 제공하는 천연의 대규모 냉각매체로 재사용될 수 있다. 버려지는 냉열 에너지는 낮은 코스트로 운영될 수 있는 중요한 청정 에너지원이기 때문에 냉방 시스템으로 개발되면, 기존의 에어콘 시스템에 견주어 볼 때 공기중에 유해한 오염원의 발생과 환경적으로 유해한 냉매 방출을 대폭적으로 줄일 수 있는 우수한 냉방 시스템이 될 것이다. 따라서, 본 연구에서는 냉열 에너지를 활용한 지역 냉방 시스템에 대한 환경 친화적 기본적 설계 개념, 여러 가지 냉방 시스템 성능에 대한 유익한 기반적 정보를 제공하고자 한다.

  • PDF

Development of Pocket Insertion style Magnetic Curer that Apply $2^{loop}\;3^{pulsed}$ Variable Magnetic type Probe for Urinary Treatment

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • 제6권1호
    • /
    • pp.73-79
    • /
    • 2008
  • Result that study magnet nerve curer for treatment induced current generation and current of ion for development in main point incontinence, prostate, sphincter, nervous system, rigidity, headache, retrogression arthritis, ligament damage, Rheumatism arthritis, peripheral nerve etc., can classify by 4. Embodied do first, full bridge magnet occurrence chapter, and communication with PC is available, confirmed various action loops an experiment. Could confirm correct treatment probe second, woman and man disease person. Third, derived so that healing may be possible naturally by addition of apron form according to disease. Because composition of finally, treatment probe composes by act of negative plate form, manufacture is easy and cooling designed for easy direction. More superior result of cooling appeared than existing in incidental and ingredients, cooling efficiency, composition, complexity, convenience etc. that expense and composition manufacture very straightforwardly and experimental by 2 - Tank ways.