• Title/Summary/Keyword: natural tooth

Search Result 301, Processing Time 0.023 seconds

A case of unexpected adjacent tooth extrusion after implant fixed prosthetic treatment, who had undergone mandibular resection and reconstruction due to ameloblastoma (법랑모세포종으로 하악골 절제 및 재건술 시행한 환자에서 임플란트 고정성 보철물 수복 후 원인 미상의 인접 치아 정출이 발생한 증례 및 고찰)

  • Kim, Su-Jin;Ha, Tae-Wook;Kim, Hyung Jun;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.448-455
    • /
    • 2019
  • Ameloblastoma is a benign odontogenic epithelial tumor with high recurrence rate and requires extensive resection of the surrounding tissue and reconstruction of defect site. Because of the anatomical limitation of the reconstruction site, prosthetic treatment with implants is the first recommendation. This is a case of prosthetic restoration of the reconstruction site with implant fixed prosthesis in patient who underwent mandibular resection and iliac bone reconstruction due to ameloblastoma. However 14 months after completion of implant prosthesis, adjacent natural tooth erupted unexpectedly, resulting in 1mm infra-occlusion occurred including posterior implant prosthesis and anterior natural teeth. In adults, implant infra-occlusion may occur due to residual growth after placement of the maxillary anterior implant. But this case, hypo-occlusion of molar implant and open bite of anterior natural teeth is occurred due to extrusion of adjacent tooth, is rare. Thus we report the treatment process including orthodontic treatment with intrusion of the posterior tooth, and investigate the causes of sudden, unexpected tooth extrusion.

Comparison of Strain on Dental Cervical Line between Tooth Fracture Test and Finite Element Analysis (치아파절시험과 유한요소해석에서의 치경 변형률에 관한 연구)

  • Yoo, Oui-Sik;Chun, Keyoung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.87-94
    • /
    • 2010
  • When occlusal force is applied to a tooth, stress concentration occurs on the dental cervical line. This study investigated to find the maximum force and strain of natural teeth using an Instron and strain gauges, comparing the strain of cervical enamel using finite element analysis(FEA). Tests were conducted with a mandibular first premolar applying the conditions of occlusion. Then, the FEA was processed with the same as conditions of the fracture test. The test showed that the maximum force, maximum compressive strain and maximum tensional strain was $278{\pm}26$ N, $0.668{\times}10^{-3}{\pm}0.678{\times}10^{-3}$ and $0.248{\times}10^{-3}{\pm}0.102{\times}10^{-3}$, respectively. It was found that six of eight measured strains were within the range of estimated strains by the FEA. Even though it was assumed that properties of FE models were isotropic, it could prove useful as a reference in understanding the tendency of dental strain.

An Experimental Study on Tooth-Meshing Frequency Components in Noise/Vibration of a Gearbox Under Operational Conditions (기어 박스 구동시 회전수 변화에 따른 이 맞물림 주파수 소음/진동 성분의 증폭에 대한 실험적 연구)

  • Lee, Seong-Hun;Kim, Kwang-Joon;Ha, Jae-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1096-1101
    • /
    • 2000
  • In machine tools, often a gearbox is installed to control the rotating speed of spindle, which sometimes generates problems of noise and vibration due to errors in tooth-meshing. In this study, the characteristics of, noise and vibration of given gearbox for a machine tool are analyzed experimentally. From the measurement, it was observed that the tooth-meshing component of the sound pressure level from the gearbox took its maximum at a specific operational speed. Therefore, the main content of this study is to investigate the reason why the above mentioned characteristics are observed. By investigating the natural frequencies of the components in gearbox, it was found that the natural frequencies of the rotating gear-shaft and gearbox for twisting mode were closely related to the first and second peak of sound pressure levels respectively. Thereform, in this study, those relations were identified by the impact test of rotating gear-shaft and-gearbox. In addition, we inserted the rubber between housing and bed, and analyze the effect of the rubber insertion on noise reduction by Operational Deflection Shapes.

  • PDF

Autotransplantation: A biological treatment alternative for a patient after traumatic dental injury

  • Vishwanath, Meenakshi;Janakiraman, Nandakumar;Vaziri, Hamed;Nanda, Ravindra;Uribe, Flavio
    • The korean journal of orthodontics
    • /
    • v.48 no.2
    • /
    • pp.125-130
    • /
    • 2018
  • Traumatic dental injury is considered a public dental health problem because of a high childhood incidence, high treatment costs, and prolonged treatment time. Although management guidelines for traumatized teeth have been outlined, tooth loss following trauma is occasionally unavoidable. Here, we describe the successful interdisciplinary management of a traumatized central incisor in an 11-year old boy that was extracted because of a poor prognosis and restored by the autotransplantation of an immature donor tooth into the site. The patient underwent orthodontic treatment in order to close the donor site space and bring the autotransplanted tooth to an ideal position. Postorthodontic treatment radiographs and photographs revealed an esthetic and functional natural tooth replacing the lost tooth. The findings from this case suggest that autotransplantation offers unique advantages as a treatment modality for the restoration of missing teeth, particularly in growing children.

Improving oral rehabilitation through the preservation of the tissues through alveolar preservation

  • Afrashtehfar, Kelvin Ian;Kurtzman, Gregori Michael;Mahesh, Lanka
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.174-178
    • /
    • 2012
  • When performing a tooth extraction, imminent collapse of the tissue by resorption and remodeling of the socket is a natural occurrence. The procedure for the preservation of the alveolar ridge has been widely described in the dental literatures and aims to maintain hard and soft tissues in the extraction site for optimal rehabilitation either with conventional fixed or removable prosthetics or implant-supported prosthesis.

A COMPARISON OF THE FORM OF THE FACE, THE DENTAL ARCH AND THE MAXILLARY CENTRAL INCISOR (안모, 치열궁 및 상악 중절치의 형태에 관한 상호 비교 연구)

  • Lee Bong-Ho;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.273-285
    • /
    • 1992
  • The purpose of this study was to evaluate facial form, arch form and tooth form in young adults to determine if a correlation exists. 115 subjects who had healthy natural maxillary incisors and good occlusion consisted of 71 males and 44 females ranging from 20-30 years of age. Facial photographs and, intraoral photographs of upper anterior teeth and dental casts of upper jaws were taken to demonstrate facial form, dental arch form and tooth form. Form analysis is determined by comparing the ratio of the widths of the faces, dental archs and the teeth. The Chi-square test of independence between facial form, arch form and tooth form, was executed and the significance level determined. The results were as follows : 1. The distribution of facial forms was 66.1% square-tapering, 27.0% square, 5.2% ovoid, 2% tapering-square. 2. The distribution of tooth forms was 65.2% ovoid, 20.0% square-tapering, 11.3 % tapering-square, 3.5 % square. 3. The distribution of arch forms was 50.4 % square-tapering, 48.7 % tapering, 0.9 % reverse tapering-square. 4. There was no large differences in the distribution of facial forms, dental arch forms and tooth-forms between male and female. 5. No relationship existed between the tooth form and the facial form. 6. No relationship existed between the facial form and the dental arch form. 7. No relationship existed between the tooth form and the dental arch form. 8. This gave the impression that dental arch form and facial form could not be used as a true index in tooth selection.

  • PDF

3D quantitative analysis and SEM qualitative analysis of natural antagonist enamel opposing CAD-CAM monolithic zirconia or lithium disilicate tooth-supported crowns versus enamel opposing natural enamel

  • Piyarat Woraganjanaboon;Chuchai Anunmana
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the maximum vertical wear, volume wear, and surface characteristic of antagonist enamel, opposing monolithic zirconia or lithium disilicate crowns. MATERIALS AND METHODS. The study comprised 24 participants (n = 12), who were randomly allocated to receive either a 5 mol% Y-TZP or a lithium disilicate crown in positions which would oppose the natural first molar tooth. The contralateral first molar along with its antagonist was considered as the enamel opposing natural enamel control. Data collection was performed using an intraoral scanner and polyvinylsiloxane impression. The means of the maximum vertical loss and the volume loss at the occlusal contact areas of the crowns and the various natural antagonists were measured by 3D comparison software. A scanning electron microscope was subsequently used to assess the wear characteristics. RESULTS. The one-year results from 22 participants (n = 11) indicated no significant differences when comparing the zirconia crown's antagonist enamel (40.28 ± 9.11 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (38.91 ± 7.09 ㎛, 0.04 ± 0.02 mm3) (P > .05). Also, there is no significant differences between lithium disilicate crown's antagonist enamel (47.81 ± 9.41 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (39.11 ± 7.90 ㎛, 0.04 ± 0.02 mm3) (P > .05). CONCLUSION. While some studies suggested that monolithic zirconia caused less wear on opposing enamel than lithium disilicate, this study found similar wear levels to enamel for both materials compared to natural teeth.

Anterior teeth alignment for aesthetic dentistry (심미치료를 위한 전치부 부분교정)

  • Park, Chul-Wan
    • The Journal of the Korean dental association
    • /
    • v.56 no.9
    • /
    • pp.512-520
    • /
    • 2018
  • As the demand for natural and beautiful smiles increases, the demand for anterior aesthetic treatment is increasing. Orthodontic treatment is often necessary for esthetic, healthy and natural treatment outcome. Particularly, in the case of middle-aged patients, minor tooth movement limited to anterior teeth is more effective than comprehensive orthodontic treatment which requires a long-term treatment period. Clinician who is in charge of aesthetic dentistry should have the ability to select a case that can be treated with partial orthodontic treatment and to determine the most effective treatment method. This article provides decision flowchart for case selection and choosing the best treatment modality for anterior teeth alignment.

  • PDF

A STRESS ANALYSIS OF FIXED PROSTHESES WITH DENTAL IMPLANT AND NATURAL TOOTH (임플랜트와 자연치를 지대치로 한 고정성 보철물의 응력분석)

  • Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.447-459
    • /
    • 1993
  • A two dimensional finite element model was constructed to analyze the mechanical behavior of four unit fixed partial dentures (FPD) with a 2nd premolar abutment either employing a rigid or nonrigid connector and a 2nd molar abutment(Branemark implant, IMZ implants and natural tooth). Gap elements were used to model the clearance space of the nonrigid connectors and each components of implants. All FPDs with a implant abutment alter the patterns of stress distribution and displacement, but the magnitude of stress in the periodontium was not greater than that of the control. A FPD with rigid connectors induced the smaller stresses in the periodontium than a FPD with a nonrigid connector. A FPD with a Branemark implant exhibited the more desirable mechanical stress states as compared to the IMZ implants with IME or IMC.

  • PDF

Preparation of Shark Byproduct Extract and Gellan Gum based Antibacterial Film Containing Green Tea Extract

  • Bak, Jing-Gi;Kim, Jin;Ohk, Seung-Ho
    • Biomedical Science Letters
    • /
    • v.28 no.1
    • /
    • pp.50-57
    • /
    • 2022
  • In this study, we tried to examine the possibility of developing a dental product such as tooth decay prevention and oral hygiene by manufacturing a natural polymer film for oral use. Natural polymer films were prepared from shark byproduct extract (SBE) and gellan gum (GG). As an antibacterial substance, the antibacterial activity of green tea extract against tooth decay-causing bacteria was measured. An film was prepared by adding green tea extract to the composition of SBE and GG. The mechanical, solubility, moisture content and antibacterial function of the prepared film were investigated in detail. Also, the incorporation of GTE into the SBE/GG film improved the physical performance of the film. Increasing the content of GTE improved the antioxidant and antibacterial properties of the film. Formulation of antimicrobial SBE/GG film containing green tea extract was established and these results evidently showed potential for cavity prevention products application.