• 제목/요약/키워드: natural testing

검색결과 703건 처리시간 0.025초

측면 절개된 판형 스프링으로 지지된 경수로 연료봉 진동의 실험적 고찰 (An Experimental Study on the Vibration of the PWR Fuel Rod Supported by the Side-sloted Plate Springs)

  • 최명환;강흥석;윤경호;송기남
    • 한국소음진동공학회논문집
    • /
    • 제13권10호
    • /
    • pp.798-804
    • /
    • 2003
  • One of the methods that are used to compare and verify the supporting performance of the spacer grids developed is the vibration characteristic test. A modal test in this paper is performed for a dummy rod 3,847 mm tall supported by eight New Doublet (ND) spacer grids. For the vibration test in air, nine accelerometers, one displacement sensor and one shaker are used for acquiring signals, and an I-DEAS TDAS software Is employed for analyzing the signals. Also, a finite element (FE) analysis is performed by a beam-spring simple model and a contact model simulating the contact phenomenon between the rod and the ND spring. And then, the results of the modal testing are compared with those of the FE analysis. The natural frequencies as well as the mode shapes obtained by the experiment have a greater similarity to the results by the contact model than the previous beam-spring model. In audition, for grasping whether or not the modal parameters are influenced by where shaking spot is, two kinds of tests are performed : one is for the shaker attached at the fourth span (center), the other is for the shaker at the fifth span that is one span nearer to the bottom of the rod. The latter shows higher MAC than the former Finally, the vibration displacements are measured in the range of 0.l12∼0.214 mm for the excitation force of 0.25∼0.75 N.

수소동위원소 저장용 ZrCo용기의 급속 냉각 성능 평가 (Rapid Cooling Performance Evaluation of a ZrCo bed for a Hydrogen Isotope Storage)

  • 이정민;박종철;구대서;정동유;윤세훈;백승우;정흥석
    • 한국수소및신에너지학회논문집
    • /
    • 제24권2호
    • /
    • pp.128-135
    • /
    • 2013
  • The nuclear fuel cycle plant is composed of various subsystems such as a fuel storage and delivery system (SDS), a tokamak exhaust processing system, a hydrogen isotope separation system, and a tritium plant analytical system. Korea is sharing in the construction of the International Thermonuclear Experimental Reactor (ITER) fuel cycle plant with the EU, Japan, and the US, and is responsible for the development and supply of the SDS. Hydrogen isotopes are the main fuel for nuclear fusion reactors. Metal hydrides offer a safe and convenient method for hydrogen isotope storage. The storage of hydrogen isotopes is carried out by absorption and desorption in a metal hydride bed. These reactions require heat removal and supply respectively. Accordingly, the rapid storage and delivery of hydrogen isotopes are enabled by a rapid cooling and heating of the metal hydride bed. In this study, we designed and manufactured a vertical-type hydrogen isotope storage bed, which is used to enhance the cooling performance. We present the experimental details of the cooling performances of the bed using various cooling parameters. We also present the modeling results to estimate the heat transport phenomena. We compared the cooling performance of the bed by testing different cooling modes, such as an isolation mode, a natural convection mode, and an outer jacket helium circulation mode. We found that helium circulation mode is the most effective which was confirmed in our model calculations. Thus we can expect a more efficient bed design by employing a forced helium circulation method for new beds.

Molecular Characterization and Expression Analysis of the Peroxisome Proliferator Activated Receptor Delta (PPARδ) Gene before and after Exercise in Horse

  • Cho, Hyun-Woo;Shin, Sangsu;Park, Jeong-Woong;Choi, Jae-Young;Kim, Nam-Young;Lee, Woon-Kyu;Lee, Hak-Kyo;Song, Ki-Duk;Cho, Byung-Wook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제28권5호
    • /
    • pp.697-702
    • /
    • 2015
  • While athletic abilities such as speed, endurance and recovery are important in the horse, genes related to these abilities have not been extensively investigated. Here, we characterized the horse peroxisome proliferator-activated receptor delta ($PPAR{\delta}$) gene and analyzed the expression of $PPAR{\delta}$ during exercise. $PPAR{\delta}$ is a known regulator of ${\beta}$-oxidation, muscle fiber transformation, and running endurance. Through evolutionary analysis using the synonymous and non-synonymous mutation ratio, it was revealed that positive selection occurred in the horse $PPAR{\delta}$ gene. Two important domains related to nuclear hormone receptors, C4 zinc finger and ligand binding domain, were also found to be conserved well in horse $PPAR{\delta}$. Horse $PPAR{\delta}$ was expressed ubiquitously in many tissues, but the expression level was various depending on the tissues. In the skeletal muscle, $PPAR{\delta}$ increased about 2.5 folds after 30 min of exercise. Unlike in muscle, the increase of $PPAR{\delta}$ expression was observed at 60 min but not 30 min of exercise in leukocytes. This finding might be useful for testing the endurance of horse using blood samples. Conclusively, the horse $PPAR{\delta}$ gene is evolutionarily conserved well and can be used as a biomarker of endurance in horse.

Development of HPTLC Fingerprinting and Phytochemical Study of a Polyherbal Unani Formulation

  • Alam, Abrar;Siddiqui, Javed Inam;Naikodi, Mohammed Abdul Rasheed;Kazmi, Munawwar Husain
    • 셀메드
    • /
    • 제10권1호
    • /
    • pp.7.1-7.6
    • /
    • 2020
  • Plants produce a wide range of active principles, making them a rich source of different types of medicines. Without any knowledge of the phytoconstituents or active principles the medicinal plants itself or in the form of polyherbal formulations, were used by all society of human being from ancient times for prevention and cure of disease, but most of the traditional formulations including the formulation of Ayurveda and Unani have not been scientifically validated in order to establish the pharmacopoeial standards to improve the efficacy. Globally, the people become conscious that uses of synthetic drugs for a long period is not safe; the trend of medical society at large is looking at alternatives from natural, safe sources to combat diseases. Due to this comprehension, it has been increased the demand for plant-derived medicine, and on the other side, it is extremely important to standardize the polyherbal formulations and validate them scientifically to improve their safety and efficacy. The polyherbal Unani formulation Safuf-e-Muallif is widely used and recommended in Unani system of medicine (USM) as a spermatogenic agent, semen thickening agent, etc. to treat sexual disorders viz. premature ejaculation, nocturnal emission, etc. The study mainly deals with phytochemical screening for the detection of nature of phytoconstituents and analytical technique like High-performance thin-layer chromatography (HPTLC) for developing fingerprint of Safuf-e-Muallif revealing specific identities of the drug. The phytochemical screening and HPTLC fingerprint profile for SM reported here may be used as a reference standard for quality control purpose in future.

Performance of Air Fresher System for the Removal of Various Odorants Released from Foodstuffs

  • Kim, Ki-Hyun;Adelodun, Adedeji A.;Deep, Akash;Kwon, Eilhann E.;Jeon, Eui-Chan;Kim, Yong-Hyun;Jo, Sang-Hee;Lee, Min-Hee;Cho, Sung-Back;Hwang, Ok-Hwa
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권1호
    • /
    • pp.37-53
    • /
    • 2017
  • The effectiveness of four air fresher (AF) systems was evaluated with respect to their removal efficiencies against offensive odorants. For this purpose, malodorous species were generated by exposing freshly cooked foods emitting odorants with levels moderately above their respective threshold values in a confined room. The deodorization efficiency of the four AF systems was then tested for a period of 30 min by estimating the extent of reduction in odorant levels after the operation of each AF. The removal efficiency of the four AF units against each odorant was evaluated as follows: (1) between AF products from different manufacturers, (2) between odorants and ultrafine particulate matter ($PM_{2.5}$), and (3) between operation and natural degassing. The average sorptive removal of odorants was generally <80% and considered less effective or non-effective relative to $PM_{2.5}$. Further examination of odor reduction, if evaluated in terms of odor indices like odor intensity (OI) and odor activity value (OAV), recorded a mean of 33% and 87%, respectively. The overall results of this study confirmed that all tested AF units were not effective to resolve odor problems created under our testing conditions.

안태음의 변이원성 및 간독성에 관한 연구 (Studies on the Mutagenicity and Hepatotoxicity of Antaeum)

  • 이동녕;문진영;오규석;이태균;최미정;이동목;남경수
    • 생약학회지
    • /
    • 제28권3호
    • /
    • pp.149-155
    • /
    • 1997
  • Antaeum(ATE) has been used as a prescription for threatened abortion, associated with pregnancy in traditional medicine. Because gravida could be administered ATE for a long period, its administration might cause a harmful effect on fetus and gravida during the pregnancy. This study aimed to determine whether exposure to ATE caused mutagenicity or hepatotoxicity during the pregnant period. For mutagenicity test of ATE, Salmonella typhimurium and Bacillus subtilis were used as indications for DNA damage. In the Ames test, Samonella typhimurium TA98 and TA100 were used for mutagenicity testing, and the number of histidine revertants was measured. In Rec-assay, Bacillus subtilis H $17(Rec^+)$ and $M-45(Rec^-)$ strains were used to clarify the DNA damage property. In the SOS umu test, Salmonella typhimurium TA15335 containing plasmid pSK1002 was used as a tester strain, and we monitored the levels of umu operon expression by measuring the ${\beta}-galactosidase$ activity. From the tested results, ATE did not show DNA damage and mutagenicity. On the other hand, hepatotoxicity of ATE to female ICR mice was monitored by the measurements of s-GOT, s-GPT and LDH activities after oral feeding for 15 days. ATE did not show significant change of s-GOT, s-GPT and LDH activities in mice sera.

  • PDF

Simultaneous Determination of Six Components in the Traditional Herbal Medicine 'Oryeongsan' by HPLC-DAD and LC-MS/MS

  • Lee, Jiwoo;Weon, Jin Bae;Lee, Bohyoung;Yun, Bo-Ra;Eom, Min Rye;Ma, Choong Je
    • Natural Product Sciences
    • /
    • 제19권1호
    • /
    • pp.20-27
    • /
    • 2013
  • A simple high performance liquid chromatography - diode array detector (HPLC-DAD) method has been developed and validated for simultaneous determination of the six components (cinnamic acid, cinnamaldehyde, eugenol, atractylenolide I, atractylenolide III, and ergosterol) in Oryeongsan. In addition, identification of six marker compounds was conducted by a LC-MS/MS analysis. The six compounds in Oryeongsan were separated on Shishedo $C_{18}$ column (5 ${\mu}m$, $4.6{\times}250$ mm) at a column temperature of $30^{\circ}C$. The mobile phase was a mixture of 0.1% trifluoroacetic acid (TFA) water and acetonitrile employing gradient elution at a flow rate of 1.0 mL/min. The detection wavelength was set at 205, 250, 280, and 330 nm. The developed method had good linearity ($R^2$ > 0.9997) and the limit of detection (LOD) and limit of quantification (LOQ) were observed within the ranges 0.01~0.15 and 0.05~0.45 ${\mu}g/mL$, respectively. The relative standard deviation (RSD) values of intra- and inter-day testing were indicated that less than 3% and 90.31~103.31% of accuracy. The results of recovery test were 90.56~106.72% and RSD range was measured from 0.84 to 2.95%. In conclusion, this HPLC-DAD method has been successfully applied to the simultaneous determination of six compounds in Oryeongsan samples.

Statistical implications of extrapolating the overall result to the target region in multi-regional clinical trials

  • Kang, Seung-Ho;Kim, Saemina
    • Communications for Statistical Applications and Methods
    • /
    • 제25권4호
    • /
    • pp.341-354
    • /
    • 2018
  • The one of the principles described in ICH E9 is that only results obtained from pre-specified statistical methods in a protocol are regarded as confirmatory evidence. However, in multi-regional clinical trials, even when results obtained from pre-specified statistical methods in protocol are significant, it does not guarantee that the test treatment is approved by regional regulatory agencies. In other words, there is no so-called global approval, and each regional regulatory agency makes its own decision in the face of the same set of data from a multi-regional clinical trial. Under this situation, there are two natural methods a regional regulatory agency can use to estimate the treatment effect in a particular region. The first method is to use the overall treatment estimate, which is to extrapolate the overall result to the region of interest. The second method is to use regional treatment estimate. If the treatment effect is completely identical across all regions, it is obvious that the overall treatment estimator is more efficient than the regional treatment estimator. However, it is not possible to confirm statistically that the treatment effect is completely identical in all regions. Furthermore, some magnitude of regional differences within the range of clinical relevance may naturally exist for various reasons due to, for instance, intrinsic and extrinsic factors. Nevertheless, if the magnitude of regional differences is relatively small, a conventional method to estimate the treatment effect in the region of interest is to extrapolate the overall result to that region. The purpose of this paper is to investigate the effects produced by this type of extrapolation via estimations, followed by hypothesis testing of the treatment effect in the region of interest. This paper is written from the viewpoint of regional regulatory agencies.

회전구동 정전형 마이크로 액추에이터를 이용한 고트랙밀도 HDD용 이단 구동 시스템 (Dual Stage Actuator System for High Density Magnetic Disk Drives Using a Rotary-type Electrostatic Microatuator)

  • 정성환;최재준;박지황;이창호;김철순;민동기;김영훈;이승희;전종업
    • 한국정밀공학회지
    • /
    • 제22권10호
    • /
    • pp.174-185
    • /
    • 2005
  • This paper presents the design, fabrication, and testing results of a dual stage actuator system for a fine positioning of magnetic heads in magnetic disk drives. A novel rotary microactuator which is electrostatically driven and utilized as a secondary actuator was designed. The stator and rotor electrodes in the microactuator was revised to have the optimal shapes and hence produces much higher rotational torque compared with the conventional comb-shape electrodes. The microactuators were successfully fabricated using SoG(silicon on glass) processing technology, which is known as being cost-effective. The fabricated microactuator has the structural thickness of $45{\mu}m$ with the gap width of approximately $3{\mu}m$. The dynamic characteristic of microactuator/slider assembly was investigated, and its natural frequency and DC gain were measured to be 3.4kHz and 32nm/V, respectively. The microactuator/slider assembly was integrated into a HDD model V10 of Samsung Electronics Co. and a dual servo algorithm was tested to explore the tracking performance of dual stage actuator system where the LDV signals instead of magnetic head signals were used. Experimental results indicate that this system achieves the tracking accuracy of 30nm. This value corresponds to a track density of 85,000 track per inch(TPI), which is about 3 times greater than that of current hard disk drives.

회전 디스크-스핀들, 액츄에이터와 지지구조의 유연성을 고려한 하드 디스크 드라이브의 고유 및 강제 진동 해석 (Free and Forced Vibration Analysis of a Hard Disk Drive Considering the Flexibility of Spinning Disk-Spindle, Actuator and Supporting Structure)

  • 서찬희;장건희;이호성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.660-665
    • /
    • 2006
  • This paper presents a finite element method to analyze the free and forced vibration of a hard disk drive (HDD) considering the flexibility of a spinning disk-spindle with fluid dynamic bearings (FDBs), an actuator with pivot bearings, an air bearing between head-disk interface and the base with complicated geometry. Finite element equation of each component is consistently derived with the satisfaction of the geometric compatibility of the internal boundary between each component. The spinning disk, hub and FDBs are modeled by annular sector elements, beam elements and stiffness and damping elements, respectively. The actuator am, E-block, suspension and base plate are modeled by tetrahedral elements. The pivot bearing in the actuator and the air bearing between head-disk interfaces are modeled by the stiffness element with five degrees of freedom and the axial stiffness, respectively. A global matrix equation obtained by assembling the finite element equations of each substructure is transformed to a state-space matrix-vector equation, and both damped natural frequencies and modal damping ratios are calculated by solving the associated eigenvalue problem with the restarted Arnoldi iteration method. Modal and shock testing are performed to show that the proposed method well predicts the vibration characteristics of a HDD.

  • PDF