• 제목/요약/키워드: myocardial imaging

검색결과 184건 처리시간 0.025초

심근 저산소증 영상 (Imaging Hypoxic Myocardium)

  • 배상균
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.141-145
    • /
    • 2005
  • Hypoxia (decreased tissue oxygen tension) is a component of many diseases such as tumors, cerebrovascular diseases and ischemic heart diseases. Although hypoxia can be secondary to a low inspired $pO_2$ or a variety of lung disorders, the most common cause is ischemia due to an oxygen demand greater than the local oxygen supply. In the heart tissue, hypoxia is often observed in persistent low-flow states, such as hibernating myocardium. Direct "hot spot" imaging of myocardial tissue hypoxia is potentially of great clinical importance because it may provide a means of identifying dysfunctional chronically ischemic but viable hibernating myocardium. A series of radiopharmaceuticals that incorporate nitroimidazole moieties have been synthesized to detect decreased local tissue pO2. In contrast to agents that localize in proportion to perfusion, these agents concentrate in hypoxic tissue. However, the ideal agents are not developed yet and the progress is very slow. Furthermore, the research focus is on tumor hypoxia nowadays. This review introduces the myocardial hypoxia imaging with summarizing the development of radiopharmaceuticals.

급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교 (Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT)

  • 김혜선;박동우;김용수;김영선;최요원;전석철;서흥석;함창곡;김순길;안유헌;최윤영;박충기
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.100-107
    • /
    • 2003
  • 목적 : 급성심근경색을 진단하는데 있어 심장자기공명영상의 유용성을 알아보고, 생존심근을 평가하는데 있어 Tl-201 심근관류 SPECT와 비교하고자 하였다. 대상 및 방법 : 흉통 및 호흡곤란이 있는 환자 중 심장자기공명영상과 Tl-201 SPECT를 시행한 17명을 후향적으로 조사하였다. 심장자기공명영상에서는 T2강조영상에서 심벽의 고신호 강도 유무, 영화영상에서 심벽 운동, Gd-DTPA 조영 증강 후 좌심실 벽의 관류 결손 및 주입 15분 후의 지연조영증강 유무를 평가하였다. T1-201 SPECT에서는 아데노신 부하 영상과 휴식기 영상을 얻어 관류 결손 유무와 관류 결손시 가역성 여부를 평가하였다. 결과 심장자기공명영상과 T1-201 SPECT 모두 급성심근경색을 진단하는데 통계적으로 의미가 있었고, T2강조영상, T1-201 SPECT, 지연조영증강 및 심벽운동 순으로 연관성이 있는 것으로 나타났고, 관류 결손은 통계적 유의성이 없었다. 생존심근 평가에 있어서는 두 검사간 유의한 차이가 없었으며, T2강조영상과 관류영상에서 T1-201 SPECT와 높은 일치율, 지연조영증강 및 심벽운동은 낮은 일치율을 보였다. 결론 : 심장자기공명영상은 급성심근경색을 진단하는데 매우 유의한 진단율을 보였고, 생존 심근여부의 판단에 있어 SPECT와 높은 일치율을 보였다. 그러나 각 검사별 판독 기준과 방법에서 많은 연구가 필요할 것으로 생각된다.

  • PDF

Comparative study of 82Sr separation/purification methods used at Brookhaven National Laboratory and ARRONAX

  • Ha, Yeong Su;Yoon, Sang-Pil;Kim, Han-Sung;Kim, Kye-Ryung
    • 대한방사성의약품학회지
    • /
    • 제5권2호
    • /
    • pp.71-78
    • /
    • 2019
  • Nuclear imaging is one of the most powerful measures for non-invasive diagnosis of myocardial vascular disease. Radionuclide such as 13N, 15O, 201Tl and 82Rb is used for the measurement of cardiac blood flow. 13N, 15O and 201Tl are produced in cyclotrons while 82Rb is obtained from generator. Rubidium (Rb), an alkali ion, behaves biologically like potassium, and accumulates in myocardial tissue. Rb has rapid blood clearance profile which allows the use of 82Rb with a short physical half-life of 75 s for non-invasive evaluation of regional myocardial perfusion. There are several advantages of 82Rb over other radioisotopes. An ultra-short half-life significantly reduces the exposure of patients to radiation and allows to repeat injections for studying the effects of medical intervention. As a positron emitter, 82Rb allows positron emission tomography (PET) imaging which have shown superior diagnostic performances. 82Rb can be produced from generator by decay of its parent 82Sr. However, the preparation of 82Sr is difficult, because appropriate purity is required to meet the specification of the product. Recently reported procedure from ARRONAX research institute showed that a Chelex-100 resin is sufficient for this purpose and additional column is not necessary. Whereas Brookhaven National Laboratory (BNL) procedure contains three ion exchange resin separation, including Chelex-100 resin. Currently, since 82Sr production site is non-existent in Korea, Korea Atomic Energy Research Institute (KAERI) has plan to produce 82Sr within specifications. We compared 82Sr purification procedures reported from ARRONAX and BNL to investigate the most suitable procedure for our conditions.

Evaluation by Contrast-Enhanced MR Imaging of the Lateral Border Zone in Reperfused Myocardial Infarction in a Cat Model

  • Ae Kyung Jeong;Sang Il Choi;Dong Hun Kim;Sung Bin Park;Seoung Soo Lee;Seong Hoon Choi;Tae-Hwan Lim
    • Korean Journal of Radiology
    • /
    • 제2권1호
    • /
    • pp.21-27
    • /
    • 2001
  • Objective: To identify and evaluate the lateral border zone by comparing the size and distribution of the abnormal signal area demonstrated by MR imaging with the infarct area revealed by pathological examination in a reperfused myocardial infarction cat model. Materials and Methods: In eight cats, the left anterior descending coronary artery was occluded for 90 minutes, and this was followed by 90 minutes of reperfusion. ECG-triggered breath-hold turbo spin-echo T2-weighted MR images were initially obtained along the short axis of the heart before the administration of contrast media. After the injection of Gadomer-17 and Gadophrin-2, contrast-enhanced T1-weighted MR images were obtained for three hours. The size of the abnormal signal area seen on each image was compared with that of the infarct area after TTC staining. To assess ultrastructural changes in the myocardium at the infarct area, lateral border zone and normal myocardium, electron microscopic examination was performed. Results: The high signal area seen on T2-weighted images and the enhanced area seen on Gadomer-17-enhanced T1WI were larger than the enhanced area on Gadophrin-2-enhanced T1WI and the infarct area revealed by TTC staining; the difference was expressed as a percentage of the size of the total left ventricle mass (T2= 39.2 %; Gadomer-17 =37.25 % vs Gadophrin-2 = 29.6 %; TTC staining = 28.2 %; p < 0.05). The ultrastructural changes seen at the lateral border zone were compatible with reversible myocardial damage. Conclusion: In a reperfused myocardial infarction cat model, the presence and size of the lateral border zone can be determined by means of Gadomer-17- and Gadophrin-2-enhanced MR imaging.

  • PDF

핵의학 영상을 이용한 생존심근 평가 (Assessment of Viable Myocardium with Nuclear Imaging)

  • 강원준
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권3호
    • /
    • pp.203-206
    • /
    • 2009
  • Nuclear cardiac imaging has been widely used to assess viable myocardium in patients with ischemic heart disease, The assessment of viable myocardium is important in selecting patients who will be benefit from revascularization. Although revascularization is indicated in patients with sufficient myocardium, patients with scar tissue should be treated medically. Nuclear imaging methods including myocardial perfusion SPECT and FDG PET have been shown to be effective modalities for identifying viable myocardium.

Evaluation of Non-infarct-Related Arteries Using C-11 Acetate PET in STEMI With Multivessel Disease

  • Sang-Geon Cho;Minchul Kim;Seung Hun Lee;Ki Seong Park;Jahae Kim;Jang Bae Moon;Ho-Chun Song
    • Journal of Cardiovascular Imaging
    • /
    • 제30권3호
    • /
    • pp.169-180
    • /
    • 2022
  • BACKGROUND: We analyzed whether C-11 acetate positron emission tomography (PET) can be used for the evaluation of non-infarct-related artery (NIRA) in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease. METHODS: We prospectively enrolled 31 patients with STEMI and at least one NIRA stenosis (diameter stenosis [DS] ≥ 50%). C-11 acetate PET was performed after successful revascularization for the infarct-related artery (IRA). Myocardial blood flow (MBF) and oxidative metabolism (kmono) were measured and compared between NIRA vs. IRA, stenotic (DS ≥ 50%) vs. non-stenotic (DS < 50%) NIRAs, and NIRAs with significant stenosis (DS ≥ 70% or fractional flow reserve [FFR] ≤ 0.80) vs. those without (neither DS ≥ 70% nor FFR ≤ 0.80). The correlations between PET and angiographic parameters were also analyzed. RESULTS: MBF and kmono were significantly higher in NIRAs than those in IRAs. Stenotic NIRAs showed significantly reduced stress MBF, myocardial flow reserve (MFR), relative flow reserve (RFR) (0.72 ± 0.12 vs. 0.82 ± 0.14; p = 0.001), and stress kmono, as compared to those in non-stenotic NIRAs. NIRAs with significant stenosis had significantly lower stress MBF, MFR, and RFR (0.70 ± 0.10 vs. 0.80 ± 0.14; p = 0.001). RFR showed the best, but modest linear correlation with DS of NIRA stenosis (r = -0.429, p = 0.001). RFR > 0.81 could effectively exclude the presence of significant NIRA stenosis. CONCLUSIONS: C-11 acetate PET could be a feasible alternative noninvasive modality in patients with STEMI and multivessel disease, by excluding the presence of significant NIRA stenosis.

Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT

  • Masafumi Takafuji;Kakuya Kitagawa;Masaki Ishida;Yoshitaka Goto;Satoshi Nakamura;Naoki Nagasawa;Hajime Sakuma
    • Korean Journal of Radiology
    • /
    • 제21권1호
    • /
    • pp.58-67
    • /
    • 2020
  • Objective: Third-generation dual-source computed tomography (3rd-DSCT) allows dynamic myocardial CT perfusion imaging (dynamic CTP) with a 10.5-cm z-axis coverage. Although the increased radiation exposure associated with the 50% wider scan range compared to second-generation DSCT (2nd-DSCT) may be suppressed by using a tube voltage of 70 kV, it remains unclear whether image quality and the ability to quantify myocardial blood flow (MBF) can be maintained under these conditions. This study aimed to compare the image quality, estimated MBF, and radiation dose of dynamic CTP between 2ndDSCT and 3rd-DSCT and to evaluate whether a 10.5-cm coverage is suitable for dynamic CTP. Materials and Methods: We retrospectively analyzed 107 patients who underwent dynamic CTP using 2nd-DSCT at 80 kV (n = 54) or 3rd-DSCT at 70 kV (n = 53). Image quality, estimated MBF, radiation dose, and coverage of left ventricular (LV) myocardium were compared. Results: No significant differences were observed between 3rd-DSCT and 2nd-DSCT in contrast-to-noise ratio (37.4 ± 11.4 vs. 35.5 ± 11.2, p = 0.396). Effective radiation dose was lower with 3rd-DSCT (3.97 ± 0.92 mSv with a conversion factor of 0.017 mSv/mGy∙cm) compared to 2nd-DSCT (5.49 ± 1.36 mSv, p < 0.001). Incomplete coverage was more frequent with 2nd-DSCT than with 3rd-DSCT (1.9% [1/53] vs. 56% [30/54], p < 0.001). In propensity score-matched cohorts, MBF was comparable between 3rd-DSCT and 2nd-DSCT in non-ischemic (146.2 ± 26.5 vs. 157.5 ± 34.9 mL/min/100 g, p = 0.137) as well as ischemic myocardium (92.7 ± 21.1 vs. 90.9 ± 29.7 mL/min/100 g, p = 0.876). Conclusion: The radiation increase inherent to the widened z-axis coverage in 3rd-DSCT can be balanced by using a tube voltage of 70 kV without compromising image quality or MBF quantification. In dynamic CTP, a z-axis coverage of 10.5 cm is sufficient to achieve complete coverage of the LV myocardium in most patients.

게이트 심근 SPECT : 도약을 위한 준비 (Pulling Bowstring of Gated Myocardial SPECT)

  • 범희승
    • 대한핵의학회지
    • /
    • 제32권5호
    • /
    • pp.433-435
    • /
    • 1998
  • Recent progress of technology permits us to assess ventricular function and wall motion as well as myocardial perfusion using electrocardiographic gated myocardial perfusion single photon emission computed tomography (GM-SPECT). It is interesting that echocardiography and magnetic resonance imaging are moving in the same direction with the use of contrast medium to assess myocardial perfusion. A valid fundamental basis for a new technology is essential for a successful competition. Lee et al. report in this issue the reproducibility of serial measurement of left ventricular function including systolic wall thickening using a novel statistical method. It has important implications such as nitroglycerin or dobutamine application during GM-SPECT. The field of nuclear cardiology must continue to strive toward more sophisticated but straightforward evaluation of cardiac diseases.

  • PDF

Post-Coronary Artery Bypass Grafting Myocardial Ischemia Caused by an Overgrown Left Internal Thoracic Artery Side Branch

  • Kim, Eung Re;Oh, Se Jin;Kang, Hyun-Jae;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • 제47권5호
    • /
    • pp.465-467
    • /
    • 2014
  • We present a patient who developed recurrent angina after coronary artery bypass grafting (CABG). Myocardial single-photon emission computed tomography (SPECT) demonstrated deterioration in the myocardial perfusion, and coronary angiography revealed an overgrown side branch of the grafted left internal thoracic artery (ITA); otherwise, there were no significant changes compared with previous imaging studies obtained after the CABG. After percutaneous embolization of the grafted left ITA side branch, the angina was resolved and myocardial SPECT showed improved perfusion.