• 제목/요약/키워드: muscular system

검색결과 253건 처리시간 0.022초

노인의 건강 체조 프로그램 적용 후 자세 균형과 근력 개선 효과분석 (Analysis of the Effect of Improving Posture Balance and Muscular Strength after Applying the Health Gymnastics Program for the Elderly)

  • 손병국;남영희
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제21권2호
    • /
    • pp.59-71
    • /
    • 2020
  • Objectives : The purpose of this study was to investigate the change of posture balance and muscular strength before and after exercise by conducting a health gymnastics program for the elderly with chronic diseases of musculoskeletal system. Methods : The subjects of this study were 32 elderly people who had no experience participating in the musculoskeletal system linkage gymnastics program over 65 years old in a rural area in H city, Gyeonggi-do. The data were analyzed by computerized processing with SPSS 23.0. Results : The results of the study were as follows: First, the average of muscular strength before and after gymnastics according to general characteristics was significant in average according to age, presence of spouse, education level, and cohabitation type. Second, the subjects exercised for 2 days a week, and 25.59(±0.51) minutes on average. Third, the change of balance of the face (t=2.993, p=.011), shoulder (t=3.811, p=.002) and pelvic left and right (t=3.584, p=.004) was statistically significant in the posture balance. Fourth, muscular strength was statistically significant in motor function of AMS, SMS, and FMS (p<0.001). Conclusion : Therefore, after applying the health gymnastics program, the improvement of posture balance and muscular strength of the elderly became apparent, so it is necessary to disseminate this gymnastics program. The health gymnastics program is expected to positively improve the quality of life for the elderly.

Evaluation of isokinetic muscular strength of elbow flexors and extensors for Korean adults

  • Lee, Sang-Do;Park, Jae-Min;Yoo, Byung-Chul
    • 대한인간공학회지
    • /
    • 제13권2호
    • /
    • pp.49-55
    • /
    • 1994
  • It is not difficult to find risky manual material handling which requires various arm exertion for moving and assembling irregular stuffs in industries. Many of workers have been hurt on their muscular and skeletal system due to the manual material handling. This study is to provide data for isokinetic muscular strength elbow flexors and extensors of Korean male and female adults. Provided standard data for isokinetic muscular strength of elbow flexous and extensors can be used for scientific and systematic analysis of arm exertionl.

  • PDF

근육 강성도 힘 피드백을 이용한 하지 보조기의 무릎 신전 운동 보조 특성 분석 (Analysis on the Assist Characteristics for the Knee Extension Motion of Lower Limb Orthosis Using Muscular Stiffness Force Feedback)

  • 김경;강승록;정구영;주수종;김남균;권대규
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.217-226
    • /
    • 2010
  • The lower limb orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of muscular activities of lower limbs was developed in this study. Compared to other knee extension assistive devices being developed by other researchers, our device is designed especially for the elderly people and intended only for slight assistance so that the subjects can keep their muscular strength. For the effectiveness of system, muscular activities of major muscles in lower limbs during sit-to-stand (STS) and squat motion were measured and analyzed. Subjects were performed the STS and squat motion with and without lower limb orthosis. We made comparison muscular activities between with and without lower limb orthosis. Lower limb orthosis was controlled using muscular stiffness force feedback that is controlled by muscular activities of the measured muscle from force sensor. For analysis of muscular activities, electromyography of the subjects was measured during STS and squat motion, and these were measured using MP 150(BIOPAC Systems, Inc.). Muscles of interest were rectus femoris(RF), vastus lateralis(VL), vastus medialis(VM) and vastus intermedius(VI) muscles in lower limbs of the right side. A biodex dynamometer was used to measure the maximal concentric isokinetic strength of the knee extensors of wearing and not wearing orthosis on right side. The test were performed using the concentric isokinetic mode of test with the velocity set at 60°/s for muscles around the knee joints. The experimental result showed that muscular activities in lower limbs wearing orthosis using muscular stiffness force of a vastus medialis muscle was reduced and knee extension torque of an knee joint wearing lower limb orthosis was increased. With this, we confirmed the effectiveness of the developed lower limb orthosis.

인공공압근육 엑츄에이터를 이용한 족관절 보조기의 족저굴곡 토크 평가 (Evaluation of Plantarflexion Torque of the Ankle-Foot Orthosis Using the Artificial Pneumatic Muscle)

  • 김경;권대규;강승록;박용군;정구영
    • 한국정밀공학회지
    • /
    • 제27권6호
    • /
    • pp.82-89
    • /
    • 2010
  • Ankle-foot orthosis with an artificial pneumatic muscle which is intended for the assistance of plantarfelxion torque was developed. In this study, power pattern of the device in the various pneumatics and the effectiveness of the system were investigated. The pneumatic power was provided by ankle-foot orthosis controlled by user‘s physiological signal, that is, muscular stiffness in soleus muscle. This pneumatic power can assist plantarflexion torque of ankle joint. The subjects performed maximal voluntary isokinetic plantarflexion motion on a biodexdynamometer in different pneumatics, and they completed three conditions: 1) without wearing the orthosis, 2) wearing the orthosis with artificial muscles turned off, 3) wearing the orthosis activated under muscular stiffness control. Through these experiments, we confirmed the effectiveness of the orthosis and muscular stiffness control using the analyzing isokinetic plantarflexion torque. The experimental results showed that isokinetic torques of plantarflexion motion of the ankle joints gradually increased in incremental pneumatic. The effectiveness of the orthosis was -7.26% and the effectiveness of the muscular stiffness control was 17.83% in normalized isokinetic plantarflexion torque. Subjects generated the less isokinetic torques of the ankle joints in wearing the orthosis with artificial muscles turned off, but isokinetic torques were appropriately reinforced in condition of wearing the orthosis activated under muscular stiffness control(17.83%) compared to wearing the orthosis(-7.26%). Therefore, we respect that developed powered orthosis is applied in the elderly that has weak muscular power as the rehabilitation equipment.

족소양담경근(足少陽膽經筋)에 대한 근육학적 고찰 (Study on Muscular System about Gall Bladder Channel of Foot Soyang Muscle)

  • 류형선;강정수
    • Journal of Acupuncture Research
    • /
    • 제22권5호
    • /
    • pp.29-36
    • /
    • 2005
  • Objectives : This study is performed to understand the interrelation between 'Foot soyang muscle of the Gall bladder channel' and 'muscular system' on the basis of the link between meridian muscle theory and myofascial pain syndrome. Methods : We have researched some of oriental medical books about meridian muscle theory and western medical books about anatomical muscular system. Results & Conclusion : 1. Myofascial pain syndrome is the medical treatment which finds the start point of the pain in fascia and then treats it on the basis of object and concrete anatomical theory, so its application is needed for objectification of the oriental medicine. 2. There is a wide difference between myofascial pain syndrome and meridian muscle theory in that the former explains each muscle individually, while the latter classifies muscles systematically in the view of organism. 3. Foot soyang muscle contains Dorsal interosseous m, Extensor digitorum longus m, Musculus peroneus brevis, longus and, tertius, lliotibial tract, Vastus lateralis m, Gluteus m, Aximus m, Piriformis m, Tensor fasciae latae m, Gluteus minimus m, Obliquus internus & externus abdominis m, External & Internal intercostal m, Serratus anterior m, Pectoralis major m, Sternocleidomastoid m, Auricularis posterior m, Temporalis m, Masseter m, Orbicularis oculi m etc. on the basis of function and the nature of a disease reflected in muscle. 4. Foot soyang muscle keeps the balance of left md right of the body on the outside, while the Gall bladder keeps the balance of the JangBuKiHyeul(臟腑氣血) on the inside.

  • PDF

수태양소장경근(手太陽小腸經筋)에 대한 근육학적(筋肉學的) 고찰(考察) (The study of muscular system about small intestine channel of hand taiyang muscle)

  • 김지남;김영일;홍권의;임윤경;이현
    • 혜화의학회지
    • /
    • 제14권1호
    • /
    • pp.67-81
    • /
    • 2005
  • We have conclusions after the study of muscular system about small intestine channel of hand taiyang muscle. Judging from many studies of interrelation between Meridian muscle and muscle, it is considered that Meridian muscle theory has some similarities with modern anatomical muscular system. It is considered that Small intestine channel of hand taiyang muscle contains Flexor digitorum profundus muscle, Extensor digiti minimi muscle, Abductor digiti minimi muscle, Extensor carpi ulnaris muscle, Flexor carpi ulnaris muscle, Triceps brachii muscle, Infraspinatus muscle, Levator scapulae muscle, Sternocleidomastoid muscle, Masseter muscle, Temporalis muscle. The symptoms of small intestine channel of hand taiyang muscle is similar to referred pain of modern Myofascial Pain Syndrome, and the medical treatment of "I Tong Wi Su(以痛爲輸)" is also similar to that of Myofascial Pain Syndrome. Small intestine channel of hand taiyang muscle is one of the three yang channels of hand muscle, and it has unity in extension of upper limb and trunk in the movement. And it is thought that weakness of small intestine channel of hand taiyang muscle is related with muscular system causing Round Shoulder and Head Forward Position.

  • PDF

수양명대장경근(手陽明大腸經筋)에 대(對)한 근육학적(筋肉學的) 고찰(考察) (The study of muscular system about Large Intestine Channel of Hand Yangmyung Muscle.)

  • 김태영;오민석
    • 혜화의학회지
    • /
    • 제17권1호
    • /
    • pp.137-143
    • /
    • 2008
  • We have conclusions after the study of muscular system about large intestine channel of hand yangmyung muscle. 1. Judging from many studies of interrelation between Meridian muscle and muscle. it is considered that Meridian muscle theory has some similarities with modern anatomical muscular system. 2. There is a wide defference betwean myofacial pain syndrome and meridian muscle theory in that the former explains each muscle individually, while the latter classifies muscles systematically in the view of organism. 3. It is considered that large intestine channel of hand yangmyung muscle contains extensor digitorum muscle, extensor muscle of index finger, brachioradialis muscle, triceps brachii muscle, Rhomboid major muscle, trapezius muscle, sternocleidomastoid muscle and muscle levator labii. 4. The symptoms of large intestine channel of hand yangmyung muscle is similar to referred pain of modern Myofacial pain syndrome, and the medical treatment of "I-Tong-Wi-Su" is similar to that of Myofacial pain syndrome.

  • PDF

측두하악장애환자에 있어서 수의적 악물기시의 치아접촉점 및 저작근 활성에 관한 연구 (A Study on the Effects of Maximum Voluntary Clenching on the Tooth Contact Points and Masticatory Muscle Activities in Patients with Temporomandibular Disorders)

  • Jae-Kap Choi;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제15권1호
    • /
    • pp.105-115
    • /
    • 1991
  • The purpose of the study was to evaluate the occlusal stability at the moment of dynamic occlusal tooth contact and to investigate the correlation between the occlusal stability and the masticatory muscle activities. It also evaluated the effect of short-term use of occlusal splints on the occlusal stability and the masticatory muscle activities in patients with temporomandibular disorders during maximum voluntary clenching by synchondronized with temporomandibular disorders during maximum voluntary clenching by synchronized use of the T-Scan system(Tekscan, Inc, USA) and K6-Diagnostic system(Myo-tronics Research, Inc, USA) The author measured its distance from retruded contact position(RCP) to intercuspal position(IP), average of contact intervals(ACI), total left-right statistics(TLR), average muscle activities of masseter and anterior temporal muscles during maximum voluntary clenching in 20 patients with temporomandibular disorders and 22 dental students as a control group. The data were compared between two groups and investigated for any correlations between the parameters. The results were as follows : 1. Both of the mean average of contact intervals and the mean absolute value of total left-right statistics during maximum voluntary clenching were increased in the patient group when compared with the control group. 2. Muscular disharmony of anterior temporal muscles of patient group is significantly greater than that of control group. However, muscular disharmony of masseter muscles of patient group is not significantly greater than that of control group. 3. There were significant correlations between muscular disharmony of anterior temporal muscles and average of contact intervals as well as total left-right statistics, and also between muscular disharmony of masseter muscles and total left-right statistics. 4. There were not any significant correlations between distance from RCP to IP and any other parameters. 5. There were a significant decrease in total left-right statistics and muscular disharmony of anterior temporal muscles during maximum voluntary clenching after a 1week use of occlusal splint in the patient group.

  • PDF

족관절 보조기를 착용한 고령자의 족관절 족저굴곡 토크 보조특성 분석 (Analysis of the Assist Characteristics for Torque of the Ankle Plantarflexion in Elderly Adults Wearing the Ankle-Foot Orthosis)

  • 김경;강승록;박용군;정구영;권대규
    • 로봇학회논문지
    • /
    • 제5권1호
    • /
    • pp.48-54
    • /
    • 2010
  • Ankle-foot orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of ankle muscular activities was developed. In this study, the effectiveness of the system was investigated during plantarflexion motion of ankle joint. To find a effectiveness of the system, the subjects performed maximal voluntary isokinetic plantarflexion contraction on a Biodex-dynamometer. Plantarfexion torque of the ankle joint is assisted by subject's soleus muscle that is generated when ankle joint do plantarflexion motion. We used the muscular stiffness signal of a soleus muscle for feedback control of ankle-foot orthosis as physiological signal. For measurement of this signal, we made the muscular stiffness force sensor. We compared a muscular stiffness force of a soleus muscle between with feedback control and without it and a maximal plantarflexion torque between not wearing a ankle-foot orthosis, without feedback control wearing it and with feedback control wearing it in each ten elderly adults. The experimental result showed that a muscular stiffness force of a soleus muscle with feedback control was reduced and plantarflexion torque of an ankle joint only wearing ankle-foot orthosis was reduced but a plantarflexion torque with feedback control was increased. The amount of a increasing with feedback control is more higher than the amount of a decreasing only wearing it. Therefore, we confirmed the effectiveness of the developed ankle-foot orthosis with feedback control.

MR 댐퍼를 적용한 불안정판에서 하지 근력 훈련이 근 활성도에 미치는 영향 분석 (Analysis on the Effects of the Lower Extremities Muscle Activation during Muscular Strength Training on an Unstable Platform with Magneto-Rheological Dampers)

  • 최윤정;박용군;권대규;김동욱;김정자;김남균
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권5호
    • /
    • pp.636-646
    • /
    • 2007
  • Adequate postural control depends on the spatial and temporal integration of vestibular, visual, and somatosensory information. Especially, the musculoskeletal function is essential to maintain the postural control. The experimental studies was performed on the muscular activities in the lower extremities during maintaining and moving exercises on an unstable platform with Magneto Rheological(MR) dampers. The unstable platform of the developed system was controlled by electric currents to the MR dampers. A subject executed the maintaining and moving exercises which are presented through the display monitor. The electromyographies of the eight muscles in lower extremities were recorded and analyzed in the time and the frequency domain: the muscles of interest were rectus femoris(RF), biceps femoris(BF), tensor fasciae latae(TFL), vastus lateralis(VL), vastus medialis(VM), gastrocnemius(Ga), tibialis anterior(TA), Soleus(So). The experimental results showed that the muscular activities differed in the four moving exercises and the nine maintaining exercises. For the anterior-posterior pattern, the TA showed highest activities; for the left-right pattern, the TFL; for the 45, $-45^{\circ}$ pattern, the TFL and TA. Also, the rate of the increase in the muscular activities were affected by the condition of the unstable platform with MR dampers for the maintaining and moving exercises. The experimental results suggest that the choice of different maintaining and moving exercises could selectively train different muscles in various intensity. Futhermore, the findings suggested that the training using this system can improve the ability of postural control.