• Title/Summary/Keyword: multiport

Search Result 53, Processing Time 0.024 seconds

A Study on the Performance Characteristics of PE-$N_2O$ Hybrid Rocket Motor with the Variation of Fuel Grain Configuration (PE-$N_2O$ 하이브리드 로켓 모터의 연료 그레인 형상 변화에 따른 성능 특성에 관한 연구)

  • Jo, Seung-Hyun;Kim, Sang-Kyum;Kim, Seong-Jin;Kim, Jong-Chan;Yoon, Chang-Jin;Sung, Hong-Gye;Kim, Jin-Kon;Moon, Hee-Jang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.398-401
    • /
    • 2007
  • The performance characteristics of Polyethylene-Nitrous oxide (PE-N2O) hybrid rocket motor with the variation of the grain geometry was investigated. To compare the performance parameters under the different port number, single and four port grains were used in this study. In order to improve the performance by enhancing mixing between fuel and oxidizer, the fuel grain having the mixing chamber was additionally studied. From the motor firing tests, it is found that the motor having 4-port fuel grain with the mixing chamber showed the highest performance among all cases. Therefore we have confirmed that with only the geometrical change of the fuel grain, it was possible to give quite influential improvement on the motor performance

  • PDF

Design of Multilevel Variable Output Voltage AC-DC Converter for Power Amplifier of Underwater Acoustic Sensor (수중 음향센서용 전력증폭기를 위한 멀티레벨 가변전압출력 AC-DC 전원회로 설계)

  • Lee, Chang-Yeol;Kim, In-Dong;Nho, Eui-Cheol;Moon, Won-Kyu;Kim, Won-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.72-83
    • /
    • 2013
  • The paper proposes a new multilevel variable output voltage AC/DC Converter for power supply of power amplifiers used in underwater acoustic sensors. The proposed multilevel variable output voltage AC/DC Converter is composed of two parts. One as the input section is the high efficiency phase-shifted PWM full bridge DC-DC converter to get multiport power sources. The other as the output section is composed of two flying-capacitor 3-level DC-DC converters and a diode bridge circuit to get fast-response and multilevel variable output voltage for an envelope amplifier. Also the paper suggests the detailed circuit topology and design guideline of multilevel variable output voltage AC/DC converter. It also proposes the power balanced control method between 3-level converters and the voltage balanced algorithm for flying capacitors. Its characteristics should be verified by the detailed simulation results. It is anticipated that the proposed converter will be used very well for power amplifiers used in underwater acoustic sensors.

A Novel Implementation of Fault-Tolerant Ethernet NIC (Network Interface Card) Using Single MAC (단일 MAC을 이용한 자동 고장 극복 Ethernet NIC (Network Interface Card) 장치 구현)

  • Kim, Se-Mog;Pham, Hoang-Anh;Lee, Dong-Ho;Rhee, Jong Myung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.11
    • /
    • pp.1162-1169
    • /
    • 2012
  • One of the important operational requirements for mission critical Ethernet networked system is having the fault tolerant capability. Such capability can be obtained by equipping multiport Network Interface Card (NIC) in each node in the system. Conventional NIC uses two or more Media Access Controls (MACs) and a co-processor for the MAC switching whenever an active port fails. Since firmware is needed for the co-processor, longer fail-over switching and degraded throughput can be generally expected. Furthermore the system upgrading requiring the firmware revision in each tactical node demands high cost. In this paper we propose a novel single MAC based NIC that does not use a co-processor, but just use general discrete building blocks such as MAC chip and switching chip, which results in better performances than conventional method. Experimental results validate our scheme.

On a Modified Structure of Taper Type Planar Power Divider/Combiner at 2 GHz (2 GHz 평면 테이퍼형 전력 분배/결합회로의 수정된 구조 연구)

  • 한용인;김인석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1005-1016
    • /
    • 2002
  • In this paper, a 2 GHz tapered shape of multiport power divider/combiner modified from the model published by [10] and adopted PBG(Photonic Band Gap) structure is proposed. Parameters determining electrical property of the circuit structure have been analyzed by HFSS simulation. For input matching, balance of output signals and phase linearity at each output port, one circular hole has been etched out on the circuit surface. 1:2 and 1:3 power dividers/combiners designed by this study have been compared with the same circuits designed by the method of [10] in terms of S-parameters. As a result, it has been found that tile modified structure and PBG of power divider/combiner have improved return loss more than 20 dB and another 18 dB. respectively, at 2 GHz.

Design and Implementation of Real-Time Monitoring System for PLGR Work (PLGR 작업을 위한 실시간 모니터링 시스템의 설계 및 구현)

  • Lee, Tae-Oh;Jeong, Seong-Hoon;Yim, Jae-Hong
    • Journal of Navigation and Port Research
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2003
  • Submarine optical fiber cable construction consists of marine survey, PLGR(Pre Lay Grapnel Run), shore-end-work, laying the submarine optical cable. This PLGR is work to ease the cable lay safely in seabed, improve the performance of Plough and ROV (Remotely-Operated Vehicle) laying work, and protect laying equipment. This paper presents the design and implementation of real-time monitoring system for PLGR work in submarine optical fiber cable construction enterprise. In this paper, we designe overall real-time monitoring system. For this purpose, the modules such as serial multiport communication module, real-time processing module, environment configuration module, real-time graph and a printout modules are designed and implemented. For the validity evaluation of this paper, serial multi port communication module, data parsing, realtime graph output are implemented and tested.

Seasonal Variations of Near-Field Dilutions of Submerged Multiport-Diffuser Discharges in Masan Bay (마산만 수중 방류수의 계절별 근역희석률 변화)

  • 강시환;박광순
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.2
    • /
    • pp.116-126
    • /
    • 1999
  • In this paper, we have studied the seasonal vanatIons of near-field dilutions of wastewater discharged from the submerged mutiport-diffuser in Masan Bay. Seasonal changes of temperature and salinity, and tidal currents were measured at 16 stations in Masan Bay. Based on the observed ambient field data, the seasonal changes of near-field dilutions due to ambient current and density fields were calculated by CORMIX model. Because of the shallow ambient water depth of 15 m, the density profiles are isopycnal in autumn and winter seasons, in which the dilution factors were the highest, 168 with the strong spring-tidal current and 110-120 with the weak neap-tidal current. As the season changes from spring to summer, the dilution factors are considerably reduced by the factor of 2 as the thermocline is getting deepened up to Sm in depth in summer. In the case of a weak ambient current, the dilution factor in summer was reduced to 1/4 of the dilution in winter. However, with strong ambient current the difference between summer and winter dilutions becomes relatively small by 30%. The results indicate that the seasonal variation of near-field dilution is very large up to 4 times with a weak neap-tidal current, but its variations become small under a strong ambient current of spring tide in MasanBay.

  • PDF

Prediction of Near-Field Dilution Changes Due to Treatment Capacity Expansion of Masan-Changwon Municipal Wastewater Treatment Plant (마산.창원 하수종말처리장 증설에 따른 근역희석률변화 예측)

  • 유승협
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.2
    • /
    • pp.53-69
    • /
    • 2000
  • For the case of the capacity increase of Masan-Changwon wastewater treatment plant, the changes of near-field dilution rates due to the increased discharges into Masan Bay from the submerged multipart-diffuser were predicted by using CORMIX model. As the increase of wastewater discharges from currently 280,000 m3f day to 720,000 m3fday by 2011, the dilution rates become much lower than the present rates. To enhance the reduced dilution rates, the engineering design changes of diffuser length and alignment were considered as an optimal engineering option. According to the results of the model simulations for these changes, the dilution rates were increased in the strong ambient current of spring tide, but they were not affected by these changes in the weak current of neap tide in Masan Bay. From the analysis of oceanographic survey data, new outfalls sites have been searched. A promising outfalls site is selected and proposed on the basis of maximum obtainable dilution rates predicted by the model simulations.

  • PDF

Single Incision Laparoscopic Appendectomy for Management of Complicated Appendicitis: Comparison between Single-Incision and Conventional

  • Oh, Yoon Jung;Sung, Nak Song;Choi, Won Jun;Yoon, Dae Sung;Choi, In Seok;Lee, Sang Eok;Moon, Ju Ik;Kwon, Seong Uk;Park, Si Min;Bae, In Eui
    • Journal of Minimally Invasive Surgery
    • /
    • v.21 no.4
    • /
    • pp.148-153
    • /
    • 2018
  • Purpose: Single incision laparoscopic appendectomy (SILA) is a widely used surgical procedure for treatment of appendicitis with better cosmesis. However, many surgeons generally tend to choose conventional multiport laparoscopic appendectomy regarding with complicated appendicitis. The aim of this study is to demonstrate the safety and feasibility of SILA for treatment of complicated appendicitis by comparison with 3-ports conventional laparoscopic appendectomy (CLA). Methods: Retrospective chart review of patients diagnosed appendicitis at single hospital during January 2015 to May 2017 collected 500 patients. Among 134 patients with complicated appendicitis, we compared outcomes for 29 patients who got SILA and 105 patients who got CLA. Results: 179 and 321 patients were treated by SILA and CLA, respectively. 134 (26.8%) patients were treated for complicated appendicitis, 29 patients by SILA and 105 patients by CLA, respectively. There was no case converted to open or added additional trocar in both groups. There were no differences in demographics with regard to age, sex, body mass index (BMI), and American society of anesthesiologists (ASA) scores. There was no difference in mean operating time ($58.97{\pm}18.53$ (SILA) vs. $57.57{\pm}21.48$ (CLA), p=0.751). The drain insertion rate (6.9% vs 37.1%, p=0.001) and the length of hospital stay ($2.76{\pm}1.41$ vs. $3.97{\pm}2.97$, p=0.035) were lower in SILA group with significance. There was no significant difference in the rate of surgical site infection (6.9% vs. 6.7%, p=1.000). Conclusion: This study demonstrates that SILA is a feasible and safe procedure for treatment of complicated appendicitis.

Plume Rise and Initial Dilution Determination Reflecting the Density Profile over Entire Water Column (해수 전체 컬럼에서 밀도 분포를 반영한 플룸 상승과 초기 희석도 결정)

    • Journal of Korean Port Research
    • /
    • v.11 no.2
    • /
    • pp.215-230
    • /
    • 1997
  • A number of ocean outfalls are located around coastal area over the United States and discharge primary treated effluent into deep water for efficient wastewater treatment. Two of them, the Sand Island and Honouliuli municipal wastewater outfalls, are located on the south coast of Oahu. There have been growing interests about the plume dynamics around the ocean outfalls since plume discharged from the multiport diffuser may have significant impacts on coastal communities and immediate consequence on public health. Among the studies of plume dynamics performed in the vicinity of both outfalls, Project MB-4 in the Mamala Bay Study recently made with the funding in the $ 9 million amount statistically dealt with the near-field behavior of the plumes at the Sand Island and Honouliuli outfalls. However, Project MB-4 predicted much higher surfacing frequency than the realistic value obtained by model studies by Oceanit Laboratories, Inc.. It is suggested that improvements should be made in the application of the plume model to more simulate the actual discharge characteristics and ocean conditions. In this study, it has been recommended that input parameters in plume models reflect realistic density profile over the entire water column since. in the previous Mamala Bay Study, the density profiles were measured at 5m depth increments extending from 13 to 63 m depth (the density profile on the upper portion of water column was not included, Roberts 1995). It is proved that the density stratification is the important parameter for the submergence of the plume. In this study, as one of the important parameters, plume rise and initial dilution reflecting the density profile over the entire water column have been taken into account for more reliable plume behavior description.

  • PDF

Unaided Stapling Technique for Pure Single-Incision Distal Gastrectomy in Early Gastric Cancer: Unaided Delta-Shaped Anastomosis and Uncut Roux-en-Y Anastomosis

  • Suh, Yun-Suhk;Park, Ji-Ho;Kim, Tae Han;Huh, Yeon-Ju;Son, Young Gil;Yang, Jun-Young;Kong, Seong-Ho;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.15 no.2
    • /
    • pp.105-112
    • /
    • 2015
  • Purpose: Intracorporeal anastomosis is the most difficult procedure during pure single-incision distal gastrectomy (SIDG) that affects its generalization. We introduced unaided delta-shaped anastomosis (uDelta), a novel anastomosis technique, for gastroduodenostomy after pure SIDG, and compared the results with those of previously reported Roux-en-Y anastomosis (RY). Materials and Methods: Between March 2014 and March 2015, SIDG with D1+ lymph node dissection was performed for early gastric cancer through a 2.5-cm transumbilical incision without any additional port. uDelta was performed by the operator alone, without any intracorporeal assistance. Results: uDelta was performed on 11 patents, and uncut RY was performed on 5-patients without open or multiport conversion. R0 resection was performed in all cases. No significant differences were observed in mean age and body mass index between patients who underwent uDelta or RY. Mean operation times were $214.5{\pm}36.2$ minutes for uDelta and $240.8{\pm}65.9$ minutes for RY, which was not significantly different. Reconstruction time for uDelta was shorter than that for RY, with marginal statistical significance ($26.1{\pm}8.3$ minutes vs. $38.0{\pm}9.1$ minutes, P=0.05). There were no intraoperative transfusions, 30-day mortality, or anastomosis-related complications in either group. Average length of hospital stay was $8.2{\pm}1.9$ days in the uDelta group and $7.2{\pm}0.8$ days in the RY group (P=0.320). Conclusions: After carefully considering indications, uDelta can be a feasible and can be a reproducible reconstruction method after SIDG in early gastric cancer.