• Title/Summary/Keyword: multiple laser

Search Result 352, Processing Time 0.026 seconds

Measurement of Geometric Errors in a Miniaturized Machine Tool Using Capacitance Sensors (정전용량센서를 이용한 소형공작기계의 기하학적 오차측정)

  • Kweon S.H.;Lee J.H.;Liu Y.;Lim C.B.;Yang S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1733-1736
    • /
    • 2005
  • Many studies have been carried out to produce 3D features in the size range between $10{\mu}m\~10,000{\mu}m$, called Meso-scale. If these miniaturized systems have high relative accuracy and good volumetric utilization, it is possible to manufacture more complex and accurate shapes with various materials as well as there are advantages of reducing energy, space and resources. Due to imperfect components and misalignment in assembly, it is necessary to assess the accuracy of the miniaturized system itself to obtain high relative accuracy. Laser interferometers are widely used to measure geometric errors called as quasi-static errors. For miniaturized system, however, it is difficult to install the required accessories such as optics and the measuring range is limited because of the size of the system and also this method is very expensive. Moreover, it is impossible to measure each error component simultaneously. A new system to measure simultaneously multiple geometric errors is proposed using capacitance sensors. Each error was measured using capacitance sensors and a measurement algorithm was mathematically derived. The experiments show that the proposed measurement system can be used effectively to assess the accuracy of miniaturized system at a low cost.

  • PDF

Historical Review on the Parabolic Reflector Moxa and Clinical Applications of Light Moxibustion in Korean Medicine (양수구(陽燧灸)(오목거울뜸)에 대한 역사적 고찰 및 한의임상(韓醫臨床)에서 광선구(光線灸)의 활용 전망)

  • Jang, In-Soo;Sun, Seung-Ho;Seo, Hyung-Sik
    • Korean Journal of Acupuncture
    • /
    • v.27 no.4
    • /
    • pp.1-4
    • /
    • 2010
  • Objectives : The purpose of this study is to summarize the historical aspects of parabolic reflector moxa and to suggest the applications of light moxibustion in Korean medicine. Results : Getting a fire by parabolic reflector(concave mirror) is well known because of the Olympic torch lighted with a solar reflector in Greece. From anecdotes or myths for Diocles and Archimedes(third century B.C.) a long history has been chronicled in books and films in western culture. However, it has another history in Asian countries since 2,000 years ago. Some reflectors had a tiny size with 6.5 to 10 cm in diameter, 4 mm to 1 cm thickness, and these mobile handheld devices could make us guess that they have been used for multiple purposes. Bronze reflectors were described in Dongeui-bogam, and excavated from the ancient remains of the Shilla and Koryo dynasties. This common firing device was used as a moxibustion device, one of the acupuncture and moxibustion modalities in traditional Korean medicine. Conclusions : Reflector moxa has been used as a light moxibustion to deliver heat energy to acupuncture points, muscles, and skin along meridians. We present a plausible proposal to improve other phototherapy modalities including reflector moxa in Korean medicine practice.

Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF)- Based Cloning of Enolase, ENO1, from Cryphonectria parasitica

  • Kim, Myoung-Ju;Chung, Hea-Jong;Park, Seung-Moon;Park, Sung-Goo;Chung, Dae-Kyun;Yang, Moon-Sik;Kim, Dae-Hyuk
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.3
    • /
    • pp.620-627
    • /
    • 2004
  • On the foundation of a database of genome sequences and protein analyses, the ability to clone a gene based on a peptide analysis is becoming more feasible and effective for identifying a specific gene and its protein product of interest. As such, the current study conducted a protein analysis using 2-D PAGE followed by MALDI- TOF and ESI-MS to identify a highly expressed gene product of C. parasitica. A distinctive and highly expressed protein spot with a molecular size of 47.2 kDa was randomly selected and MALDI-TOF MS analysis was conducted. A homology search indicated that the protein appeared to be a fungal enolase (enol). Meanwhile, multiple alignments of fungal enolases revealed a conserved amino acid sequence, from which degenerated primers were designed. A screening of the genomic $\lambda$ library of C. parasitica, using the PCR amplicon as a probe, was conducted to obtain the full-length gene, while RT-PCR was performed for the cDNA. The E. coli-expressed eno 1 exhibited enolase enzymatic activity, indicating that the cloned gene encoded the C. parasitica enolase. Moreover, ESI-MS of two of the separated peptides resolved from the protein spot on 2-D PAGE revealed sequences identical to the deduced sequences, suggesting that the cloned gene indeed encoded the resolved protein spot. Northern blot analysis indicated a consistent accumulation of an eno1 transcript during the cultivation.

Nuclear and Microtubule Reorganization in Cattle Nuclear Transfered Embryos

  • Shin, Mi-Ra;Park, Sang-Wook;Cui, Xiang-Shun;Shim, Ho-Sup;Kim, Nam-Hyung
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.18-18
    • /
    • 2001
  • Despite of importance of integrated events of nucleus and microtubule remodeling in nuclear transferred embryos with somatic cells, little information is available on this subject. In this study we configured chromatin and microtubule organization following somatic cell nuclear transfer in pre- and non-activated bovine oocytes in order to clearify nuclear remodeling process and to demonstrate centrosome inheritance during nuclear transfer. The cumulus-oocyte complexes were collected from slaughterhouse and were matured in vitro for 20 h in TCM 199 supplemented hormone. Matured bovine oocytes were enucleated by aspirating the frist polar body and metaphase chromatin using a beveled pipette. Bovine fibroblast cells were fused into enucleated oocyte by electrical stimulation. Reconstructed oocytes were activated with ionomycine and 6-dimethylaminopurin, and then cultured in CRlaa medium. The organization of nuclear and microtubules were observed using laser-scanning confocal microscopy. At 1 hour after fusion, microtubule aster was seen near the transferred nucleus in most oocytes regardless activation condition. While most of fibroblast nuclei remodeled to premature chromosome condensation (PCC) and to the two masses of chromosome in non-activated oocytes, a few number of fibloblasts went to PCC and multiple pronuclear like structures in activated oocytes. Microtubular spindle was seen around condensed chromosome. Gamma-tubulin was detected in the vicinity of condensed chromosome, suggesting this is a transient spindle. The spindle seperated nucleus into two masses of chromatin which developed to the pronuclear like structures. Two pronuclear like structures were than apposed by microtubular aster and formed one syngamy like nuclear structure at 15 h following nuclear transfer. At 17 to 18 h after fusion, two centrosomes were seen near the nucleus, which nucleates micrtubules for two cell cleavage. While 31% of reconstructed oocytes in non-activated condition developed to morulae and blastocysts, a few reconstructed oocytes in pre-activated condition developed to the blastocyst. These results suggested introduction of foreign centrosome during nuclear transfer, which appeared to give an important role for somatic cell nuclear reprogramming.

  • PDF

The Effect of Extracellular Glutamate Release on Repetitive Transient Ischemic Injury in Global Ischemia Model

  • Lee, Gi-Ja;Choi, Seok-Keun;Eo, Yun-Hye;Kang, Sung-Wook;Choi, Sam-Jin;Park, Jeong-Hoon;Lim, Ji-Eun;Hong, Kyung-Won;Jin, Hyun-Seok;Oh, Berm-Seok;Park, Hun-Kuk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.1
    • /
    • pp.23-26
    • /
    • 2009
  • During operations, neurosurgeons usually perform multiple temporary occlusions of parental artery, possibly resulting in the neuronal damage. It is generally thought that neuronal damage by cerebral ischemia is associated with extracellular concentrations of the excitatory amino acids. In this study, we measured the dynamics of extracellular glutamate release in 11 vessel occlusion(VO) model to compare between single occlusion and repeated transient occlusions within short interval. Changes in cerebral blood flow were monitored by laser-Doppler flowmetry simultaneously with cortical glutamate level measured by amperometric biosensor. From real time monitoring of glutamate release in 11 VO model, the change of extracellular glutamate level in repeated transient occlusion group was smaller than that of single occlusion group, and the onset time of glutamate release in the second ischemic episode of repeated occlusion group was delayed compared to the first ischemic episode which was similar to that of single 10 min ischemic episode. These results suggested that repeated transient occlusion induces less glutamate release from neuronal cell than single occlusion, and the delayed onset time of glutamate release is attributed to endogeneous protective mechanism of ischemic tolerance.

Determination of Lipid A Profile of Gram-Negative Bacteria from Arctic Soils Using Mass Spectrometric Approaches (질량분석 시스템을 이용한 극지 토양 유래 신규 미생물의 지질 A 화학적 구조 분석)

  • Hwang, Cheol-hwan;Park, Han-Gyu;Kim, Yun-Gon
    • KSBB Journal
    • /
    • v.31 no.4
    • /
    • pp.263-269
    • /
    • 2016
  • For decades, the microorganisms in arctic soils have been newly discovered according to the climate change and global warming. In this study, the chemical structure of a lipid A molecule from Pseudomonas sp. strain PAMC 28615 which was newly discovered from arctic soils was characterized by mass spectrometric approaches such as matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and MALDI multi-stage tandem mass spectrometry (MS). First, lipopolysaccharide (LPS) from Pseudomonas sp. strain PAMC 28615 was extracted and subsequently hydrolyzed to obtain the lipid A. The parent ion peak at m/z 1632 was determined by MALDI-TOF MS, which also can validate our lipid A purification method. For detailed structural determination, we performed the multiple-stage tandem mass analysis ($MS^4$) of the parent ion, and subsequently the abundant fragment ions in each MS stage are tested. The fragment ions in each MS stage were produced from the loss of phosphate groups and fatty acyl groups, which could be used to confirm the composition or the position of the lipid A components. Consequently, the mass spectrometry-based lipid A profiling method could provide the detail chemical structure of lipid A from the Pseudomonas sp. strain PAMC 28615 as an arctic bacterium from the frozen arctic soil.

Design of pixelated phase gratings for optical image generation (광영상 발생을 위한 화소형 위상격자의 설계 및 제작)

  • Lee, Deug-Ju;Kim, Nam;Lee, Kwon-Yeon;Eun, Jae-Jeong
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.5
    • /
    • pp.132-141
    • /
    • 1996
  • The pixelated phase grating has been studied as a kind of diffraction gratings splitting and input beam into multiple spots. It consists of regular size cells which produce phase delays, and each cell provokes the phase delay up to sixteen levels. We have compared and analyzed the characteristics of multi-level phase gratings, laying streess on efficiency and resulted pattern. Experimental resutls obtained form fabricated grating have been presented, and the real-time method using a liquid-crystal spatial light modulator has been demonstrated through experiments. Gratings making meams with specific intensities have been designed and optical images have been generated by them. In order to specific intensities have been designed and optical images have been genrated by them. In order to decide the phase delay of each cell, optimization conditon consists of diffraction efficiency and target values. One period of phase gratings fabricated with surface relief was less than 256${\mu}m{\times}256{\mu}m$ and size of each cell was 1${\mu}m{\times}1{\mu}m$ surface relief grating has been made by coating photoresist on the glass plate, writing information pattern by Ar laser and developing it. in the experiment for real-tiem processing liquid-crystal display of epson video projector has been used.

  • PDF

A Study for Vision-based Estimation Algorithm of Moving Target Using Aiming Unit of Unguided Rocket (무유도 로켓의 조준 장치를 이용한 영상 기반 이동 표적 정보 추정 기법 연구)

  • Song, Jin-Mo;Lee, Sang-Hoon;Do, Joo-Cheol;Park, Tai-Sun;Bae, Jong-Sue
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.315-327
    • /
    • 2017
  • In this paper, we present a method for estimating of position and velocity of a moving target by using the range and the bearing measurements from multiple sensors of aiming unit. In many cases, conventional low cost gyro sensor and a portable laser range finder(LRF) degrade the accuracy of estimation. To enhance these problems, we propose two methods. The first is background image tracking and the other is principal component analysis (PCA). The background tracking is used to assist the low cost gyro censor. And the PCA is used to cope with the problems of a portable LRF. In this paper, we prove that our method is robust with respect to low-frequency, biased and noisy inputs. We also present a comparison between our method and the extended Kalman filter(EKF).

Automatic Extraction of Individual Tree Height in Mountainous Forest Using Airborne Lidar Data (항공 Lidar 데이터를 이용한 산림지역의 개체목 자동 인식 및 수고 추출)

  • Woo, Choong-Shik;Yoon, Jong-Suk;Shin, Jung-Il;Lee, Kyu-Sung
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.3
    • /
    • pp.251-258
    • /
    • 2007
  • Airborne Lidar (light detection and ranging) can be an effective alternative in forest inventory to overcome the limitations of conventional field survey and aerial photo interpretation. In this study, we attempt to develop methodologies to identify individual trees and to estimate tree height from airborne Lidar data. Initially, digital elevation model (DEM) data representing the exact ground surface were generated by removing non-ground returns from the multiple-return laser point clouds, obtained over the coniferous forest site of rugged terrain. Based on the canopy height model (CHM) data representing non-ground layer, individual tree heights are extracted through pseudo-grid method and moving window filtering algorithm. Comparing with field survey data and aerial photo interpretation on sample plots, the number of trees extracted from Lidar data show over 90% accuracy and tree heights were underestimated within 1.1m in average at two plantation stands of pine (Pinus koraiensis) and larch (Larix leptolepis).

Rock Fragmentation Assessment of a Drill Bit by Hopkinson Bar Percussion Test (홉킨스바 타격시험을 통한 드릴비트의 암반파쇄 분석)

  • Kwon, Ki-Beom;Song, Chang-Heon;Park, Jin-Young;Shin, Dae-Young;Cho, Jung-Woo;Cho, Sang-Ho
    • Tunnel and Underground Space
    • /
    • v.23 no.1
    • /
    • pp.42-53
    • /
    • 2013
  • The percussion rate and spacing of the button of drill bit are very important in maximizing the drilling efficiency. Therefore, a series of percussion tests using Hopkinson bar system was carried out to assess the fragmentation performance against the beat rate and spacing of a drill bit. First, single percussion test complemented with numerical simulation was performed to analyze rock fragmentation phenomenon and to describe the fragmentation process. Next, multiple percussion test that repetitively strike the rock sample moving at predetermined rate was carried out to predict drilling efficiency against the button spacing. After the tests, the fragmented volume of the rock was measured by laser scanner and the drilling performance was analyzed using the calculated percussive energy and measured negative volume. Based on the results, the single impact performance of drill bit with 102 mm diameter was predicted.