• Title/Summary/Keyword: multiple laser

Search Result 352, Processing Time 0.026 seconds

Tempo of Diversification of Global Amphibians: One-Constant Rate, One-Continuous Shift or Multiple-Discrete Shifts?

  • Chen, Youhua
    • Animal Systematics, Evolution and Diversity
    • /
    • v.30 no.1
    • /
    • pp.39-43
    • /
    • 2014
  • In this brief report, alternative time-varying diversification rate models were fitted onto the phylogeny of global amphibians by considering one-constant-rate (OCR), one-continuous-shift (OCS) and multiple-discrete- shifts (MDS) situations. The OCS diversification model was rejected by ${\gamma}$ statistic (${\gamma}=-5.556$, p<0.001), implying the existence of shifting diversification rates for global amphibian phylogeny. Through model selection, MDS diversification model outperformed OCS and OCR models using "laser" package under R environment. Moreover, MDS models, implemented using another R package "MEDUSA", indicated that there were sixteen shifts over the internal nodes for amphibian phylogeny. Conclusively, both OCS and MDS models are recommended to compare so as to better quantify rate-shifting trends of species diversification. MDS diversification models should be preferential for large phylogenies using "MEDUSA" package in which any arbitrary numbers of shifts are allowed to model.

Scanning System and Reproduction of Adjustable Lower Dental Impression Tray (스캐닝 시스템과 하악용 가변형 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.3
    • /
    • pp.254-257
    • /
    • 2011
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable lower dental impression trays. Multiple impressions of a resin master model were made with custom, stock and new adjustable trays and vinyl polysiloxane impression material. The lower master model and resulting cast were compared using an dental scanning system. Each 3D image was superimposed onto the lower master model image and analyzed with custom software. Multiple measurements of the lower master model and casts were analyzed to determine the accuracy of tray types.

The effect of multiple application on microtensile bond strength of all-in-one dentin adhesive systems

  • Son, Sung-ae;Hur, Bock
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.567-567
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. The dentin surface of human molars, sectioned to remove the enamel from the occlusal surface were prepared. In group I, Scotchbond Multipurpose(SM, 3M ESPE) was applied by manufature's recommended. In group II, after the all-in-one adhesive, Adper Prompt L-Pop was applied for 15s, and light cured for 10s, the second coat was re-applied and light-cured.(omitted)

  • PDF

The Design of Controller for Unlimited Track Mobile Robot

  • Park, Han-Soo;Heon Jeong;Park, Sei-Seung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.41.6-41
    • /
    • 2001
  • As autonomous mobile robot become more widely used in industry, the importance of navigation system is rising, But eh primary method of locomotion is with wheels, which cause man problems in controlling tracked mobile robots. In this paper, we discuss the used navigation control of tracked mobile robots with multiple sensors. The multiple sensors are composed of ultrasonic wave sensors and vision sensors. Vision sensors gauge distance using a laser and create visual images, to estimate robot position. The 80196 is used at close range and the vision board is used at long range. Data is managed in the main PC and management is distributed to ever sensor. The controller employs fuzzy logic.

  • PDF

Enhancing the Performance of Coherent Sources SAC OCDMA Networks via Spatial Multiplexing

  • Alhassan, Ahmed M.;Badruddin, Nasreen;Saad, Naufal M.;Aljunid, Syed A.
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.471-480
    • /
    • 2013
  • The beating of two or more lasers that have the same or a finite difference in the central frequencies, is the main source of noise in spectral amplitude coding optical code division multiple access (SAC OCDMA) systems. In this paper we adopt a spatial multiplexing (SM) scheme for SAC OCDMA systems to mitigate this beat noise. The results show that for different code weights and different data rates SM SAC can support a larger number of users than the conventional SAC for all different laser source configurations. However, SM SAC requires a more complex system than the conventional SAC, and almost twice as much optical component.

Usage of Multiple Regression Analysis in Prediction System of Process Parameters for Arc Robot Welding (아크로봇 용접 공정변수 예측시스템에 다중회귀 분석법의 사용)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.871-877
    • /
    • 2008
  • It is important to investigate the relationship between weld process parameters and weld bead geometry for adaptive arc robot welding. Howeve, it is difficult to predict an exact back-bead owing to gap in process of butt welding. In this paper, the quantitative prediction system to specify the relationship external weld conditions and weld bead geometry was developed to get suitable back-bead in butt welding which is widely applied on industrial field. Multiple regression analysis for the prediction of process parameters was used as the research method. And, the results of the prediction method were compared and analyzed.

Measurement of optical coefficients of multiple scattering media by using frequency domain spectroscopy (주파수 영역 분광법을 이용한 다중산란 매질의 광학계수 측정)

  • 전계진;윤길원;김건식;전성만;박승한
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.357-363
    • /
    • 1999
  • A frequency domain spectroscopic system was constructed to investigate the optical properties of multiple scattering media. The alternating current (AC) and phase lag components of backscattered light were measured by using the heterodyne detection method. Absorption and transport scattering coefficients were computed from the values based on diffusion theory. Predictions showed excellent matches in comparison with actual values of absorption and scattering. Predictable ranges of the optical coefficients were analyzed in terms of the distance between light source and detector, and modulation frequencies. A proposed compact experimental set-up using laser diodes can be utilized to estimate non-invasively the optical properties of multiple scattering media such as biological tissues.

  • PDF

Radiofrequency Ablation and Excision of Multiple Cutaneous Lesions in Neurofibromatosis Type 1

  • Kim, Seong-Hun;Roh, Si-Gyun;Lee, Nae-Ho;Yang, Kyung-Moo
    • Archives of Plastic Surgery
    • /
    • v.40 no.1
    • /
    • pp.57-61
    • /
    • 2013
  • Background Von Recklinghausen disease or neurofibromatosis type 1 is an autosomal dominant genetic disorder of chromosome 17q11.2. The most common characteristic findings of NF 1 include multiple and recurrent cutaneous neurofibromas associated with psychosocial distress. Methods Sixteen patients (9 female, 7 male; average age, 31 years; range, 16 to 67 years) with multiple cutaneous neurofibromas between March 2010 and February 2012 were included in the study. All patients were treated with radiosurgical ablation and excision under general anesthesia. Results All 16 patients were satisfied with the results, when questioned directly during the outpatient department follow-up. The only complaint from a few patients was minimal scarring, but acceptable results were obtained in the end. Conclusions The radiofrequency procedure is almost bloodless and quick, creating a smaller necrotizing zone. Therefore, instead of employing the time consuming traditional surgery, such as laser therapy and electrosurgical excision, that produces uncertain results and can affect normal adjacent tissue, treatment of neurofibromas with radiofrequency ablation and excision can be an alternative choice of treatment for patients with a large number of neurofibromas.

Application of Multiple Linear Regression to Predict Mechanical Properties of 316L Stainless Steel with Unspecified Pit Corrosion (불특정 공식손상을 가진 316L 스테인리스강의 기계적 물성치 예측을 위한 다중선형회귀 적용)

  • Kwang-Hu Jung;Seong-Jong Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2023
  • The aim of this study was to propose a multiple linear regression (MLR) equation to predict ultimate tensile strength (UTS) of 316L stainless steel with unspecified pit corrosion. Tensile specimens with pit corrosion were prepared using a potentiostatic acceleration test method. Pit corrosion was characterized by measuring ten factors using a confocal laser microscope. Data were collected from 22 tensile tests. At 85% confidence level, total pit volume, maximum pit depth, mean ratio of surface area, and mean area were significant factors showing linear relationships with UTS. The MLR equation using these three significant factors at a 85% confidence level showed considerable prediction performance for UTS. Determination coefficient (R2) was 0.903 with training and test data sets. The yield strength ratio of 316L stainless steel was found to be around 0.85. All specimens with a pit corrosion presented a yield ratio of approximately 0.85 with R2 of 0.998. Therefore, pit corrosion did not affect the yield ratio.

A Study on Minimum Transmit Power and Interference in ZigBee Transceivers at 2.4GHz in Multiple Integrated Laser Engagement System (2.4GHz대역 ZigBee 송수신기를 사용한 과학화 전투훈련 시스템에서 최소송신전력과 간섭에 관한 연구)

  • Kwak, Hyun-Sang;Yoo, Ho-Joon;Kim, Young-Ho;Chun, Sang-Hyun;Kim, Jong-Heon;Lee, Chan-Joo;Lim, Seung-Chan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.47-54
    • /
    • 2008
  • In this paper, interference analysis has been performed between RF receiver and transmitters on each soldier for Multiple Integrated Laser Engagement System(MILES) which are following ZigBee standard. In order to obtain minimum transmit power without interference, 1% Packet Error Rates(PER) from 14 transmitters attached on a soldier to a receiver are measured with the scenarios for simple transmitting and receiving network configuration and for repeating network configuration. Based on this transmit power, the available distance for interference free among soldiers is simulated using Spectrum Engineering Advanced Monte Carlo Analysis Tool(SEAMCAT). Later scenario gives the benefit of 10dB lower transmit power, smaller and lighter power source, and better activity of trainee.