• Title/Summary/Keyword: multiple laser

Search Result 352, Processing Time 0.027 seconds

Characterization of submicron Particles Using a Single Particle Mass Spectrometer(I) - Non - Linear Correlation Between Particle Size and Mass Spectra Signals - (단일입자 질량분석기를 애용한 서브마이크론 입자의 특성화(I) - 입자의 크기와 질량분광신호의 비선형성 -)

  • Zachariah Michael R.;Lee Donggeun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.453-459
    • /
    • 2005
  • In this paper, we are proposing a robust tool which is capable of measuring the size and elemental composition of submicron particles from twenty to several hundreds nanometers at the same time, i.e., named Single Particle Mass Spectrometer (SPMS). The home-made SPMS employs a laser ablation/multi-photon ionization method to tear a nanoparticle into the constituent elemental ions. One thing different from the conventional Aerosol Time-of-Flight Mass Spectrometer (ATOFMS) is the power of the ionization laser. Much strong laser used in this work makes it possible to generate elemental ions rather than molecular ions from a nanoparticle. Also the use of high power laser may guarantee a complete ionization of a particle, which was confirmed by the existence of multiple charged ions. If a particle is evaporated/ionized completely and detected through electric field-free TOF tube without any loss, we can extract the original particle volume from the measured total ion numbers. Collecting a number of particles mass spectra, we get a database of size and elemental composition of nanoparticles, with which we may take a took into any kinds of chemical reaction occurring at nanoscale. Several issues related to size estimation by SPMS will be discussed.

Fatigue Crack Localization Using Laser Nonlinear Wave Modulation Spectroscopy (LNWMS)

  • Liu, Peipei;Sohn, Hoon;Kundu, Tribikram
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.6
    • /
    • pp.419-427
    • /
    • 2014
  • Nonlinear features of ultrasonic waves are more sensitive to the presence of a fatigue crack than their linear counterparts are. For this reason, the use of nonlinear ultrasonic techniques to detect a fatigue crack at its early stage has been widely investigated. Of the different proposed techniques, laser nonlinear wave modulation spectroscopy (LNWMS) is unique because a pulse laser is used to exert a single broadband input and a noncontact measurement can be performed. Broadband excitation causes a nonlinear source to exhibit modulation at multiple spectral peaks owing to interactions among various input frequency components. A feature called maximum sideband peak count difference (MSPCD), which is extracted from the spectral plot, measures the degree of crack-induced material nonlinearity. First, the ratios of spectral peaks whose amplitudes are above a moving threshold to the total number of peaks are computed for spectral signals obtained from the pristine and the current state of a target structure. Then, the difference of these ratios are computed as a function of the moving threshold. Finally, the MSPCD is defined as the maximum difference between these ratios. The basic premise is that the MSPCD will increase as the nonlinearity of the material increases. This technique has been used successfully for localizing fatigue cracks in metallic plates.

A study of multiple-exposure nanosphere lithography for photonic quasi-crystals fabrication (광자 준결정 제작을 위한 다중 노광 나노구 리소그라피 연구)

  • Yeo, Jong-Bin;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.62-62
    • /
    • 2010
  • Photonic quasi-crystals(PQCs) have been fabricated by a multiple-exposure nanosphere lithography (MENSL) method using the self-assembled nanospheres as lens-mask patterns. The multiple-exposing source is collimated laser beam and rotation, tilting system. The arrays of the PQCs exhibited variable lattice structures and shape the control of ratating angle ($\theta$), tilting angle ($\gamma$) and the exposure conditions. The used nanosphere size is upto the $1\;{\mu}m$. Images of prepared 2D PQCs were observed by SEM. We believe that the MENSL method is a suitable useful tool to realize the PQCs arrays of large area.

  • PDF

Ultrasensitive laser interferometer for precision measurement of small vibration displacement (고감도 레이저 간섭계를 이용한 미소 진동 진폭의 정밀측정)

  • 서상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.440-449
    • /
    • 1988
  • Small vibration displacements may be measured by optical interferometers, based on the Michelson method. The standard Michelson interferometer works well when the mirror displacements are relatively large compared to the optical wavelength. But it does not work for displacements less than approximately a quater of optical wavelength. Several multiple reflection laser interferometers, simply modified standard Michelson interferometer, have been developed to decrease the minimum detectable limits. Among these a relatively simple and easy multiple reflection system is used to measure the small vibration displacements. This multiple reflection system is constructed with a right angle prism and a convex lens. Therefore this system makes it possible to measure a vibration displacement of the small area on the vibrating structure. The fringe interpolation method and curve fitting method are used to determine accurately the small vibration displacements from the measured interference fringe patterns. Also computer simulation technique is used to check the accuracies of these method. According to the results of the computer simulation technique, the curve fitting method is more accurate than the fringe interpolation method. The optically measured results are in good agreement with those of the standard accelerometer with high accuracy and it is possible to measure the peak vibration displacement as small as 9.01nm using multiple reflection system and curve fitting method.

Fabrication and characterization of InGaAsP/InP multi-quantum well buried-ridge waveguide laser diodes (Buried-Ridge Waveguide Laser Diode 제작 및 특성평가)

  • 오수환;이지면;김기수;이철욱;고현성;박상기
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.669-673
    • /
    • 2003
  • We fabricated a buried-ridge waveguide laser diode (B-RWG LD) which has more advantages for obtaining lateral single mode operation on the same ridge width and for the planarization of the device surface, compared to the conventional RWG LD. In this LD, the difference of the lateral effective refractive index can be controlled by the thickness of the InGaAsP layer which is grown on the active and the p-InP layers. The InGaAsP multiple quantum well was grown on a n-InP substrate by the CBE. The buried ridge structure was formed by selective wet etchings, followed by liquid phase epitaxy methods. The fabricated LD with the ridge width of 7 ${\mu}{\textrm}{m}$ showed a linear increase of the optical power up to 20 ㎽ without any kinks and a saturated output power of more than 80 ㎽. By measuring the far field pattern, we demonstrate that LDs with the ridge widths of 5 ${\mu}{\textrm}{m}$ and 7 ${\mu}{\textrm}{m}$ were operated in a lateral single mode up to 2.7I$_{th}$ and 2.4I$_{th}$, respectively.ely.

Low-Complexity Handheld 3-D Scanner Using a Laser Pointer (단일 레이저 포인터를 이용한 저복잡도 휴대형 3D 스캐너)

  • Lee, Kyungme;Lee, Yeonkyung;Park, Doyoung;Yoo, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.458-464
    • /
    • 2015
  • This paper proposes a portable 3-D scanning technique using a laser pointer. 3-D scanning is a process that acquires surface information from an 3-D object. There have been many studies on 3-D scanning. The methods of 3-D scanning are summarized into some methods based on multiple cameras, line lasers, and light pattern recognition. However, those methods has major disadvantages of their high cost and big size for portable appliances such as smartphones and digital cameras. In this paper, a 3-D scanning system using a low-cost and small-sized laser pointer are introduced to solve the problems. To do so, we propose a 3-D localization technique for a laser point. The proposed method consists of two main parts; one is a fast recognition of input images to obtain 2-D information of a point laser and the other is calibration based on the least-squares technique to calculate the 3-D information overall. To verified our method, we carry out experiments. It is proved that the proposed method provides 3-D surface information although the system is constructed by extremely low-cost parts such a chip laser pointer, compared to existing methods. Also, the method can be implemented in small-size; thus, it is enough to use in mobile devices such as smartphones.

Influence of Surface Roughness on Morphology of Aluminum Alloy After Pulsed-Laser Irradiation (펄스 레이저 조사 후 알루미늄 합금의 표면상태에 대한 표면 거칠기의 영향)

  • Choi, Sung-Ho;Kim, Chung-Seok;Jhang, Kyung-Young;Shin, Wan-Soon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1105-1111
    • /
    • 2011
  • The objective of this study is to investigate the influence of surface roughness on the morphology of aluminum 6061-T6 alloy after irradiation with a Nd:YAG pulsed laser. The test specimen was prepared by a polishing process using a diamond paste ($1{\mu}m$) and emery polishing papers (#100, #220, #600, #2400) to obtain different initial surface roughness. After irradiation with ten pulsed-laser shots, the surface morphology was examined by using scanning electron microscopy (SEM), optical microscopy (OM), and atomic force microscopy (AFM). The diameter of the melted zone increased with the surface roughness because the multiple reflections and absorption of the laser beam occurred on the surface because of the surface roughness, so that the absorptance of the laser beam changed. This result was verified using the relative absorptance calculated from the diameter of the melted zone with the surface roughness and the diameter increased with the average surface roughness.